CH88 In Situ Flue Gas Oxygen Transmitter

Similar documents
FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

Vortex EX DELTA lowmeter Technical Specifications

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Compact flue gas analyser: testo 300 M-I

Using the PPM2 Portable Trace Moisture Transmitter

VERIS Accelabar. Superior Flow Measurement Accuracy

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Industrial Flowmeters

Agilent 4339B/4349B High Resistance Meters Technical Overview

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

Online Gas Analyzer / Monitor

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Rosemount 405 Compact Orifice Primary Element

Target Inline Flowmeter

Thermocouple for Flue Gas Temperature Measurements,

Gilflo flowmeters. for steam, liquids and gases

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

Flanged Water Meters (non-continuous flow)

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

S700 Modular Gas Analyzer. Measures more than 60 different gases

BURNERS EXCESS AIR SINGLE TUNNEL COOL FLAME

COMBIMASS Thermal Gas Flow

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Flow Through Toroidal Conductivity Sensor

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

8 stream capability with dual mode (H 2 S & total Sulphur)

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

GAS 3050P NDIR FLUE GAS

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

DIVA flowmeter. for saturated steam flow measurement

Pressure & Vacuum Measurement. Solutions. Series 274

Chloride/Sulfate Analyzer

CYTOPERM 2 CO 2 - AND CO 2

STANDARD TECHNICAL SPECIFICATION FOR ELECTROMAGNETIC FLOW METER with ACCESSORIES

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

Reference thermometer Model CTP5000

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

EuroFID Total Hydrocarbon Analyzer

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

Battery-Powered Magnetic Flow Meter

Liquid level switch BW 17

Oxygen Sensor QGO20...

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Dorot Irrigation Meter

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Particle Monitoring

MP-400. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

Improving Steel Reheat Furnace Performance with the ZoloSCAN-RHT Combustion Monitoring System

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

Process Total Organic Carbon Analyzer

Float Flow Meters series NF

Fine particle measuring system

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Accutube Averaging Pitot Tubes

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

MP-300. The most thermally efficient, robust and reliable medical incinerators on the market. Simply Built Better!

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

CHAPTER 1 INTRODUCTION

Control Solutions for Farm Dairies

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Sensor unit MC2 for toxic gases and oxygen with analog output

EC medium pressure axial fans.

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Platinum Resistance Thermometer (PRT) Selection Guide

Analytical Instruments

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

NRF CAPACITANCE LEVEL TRANSMITTER

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

PORTABLE FLUE GAS ANALYZER

RPM Rotary Gas Meters

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

COMBUSTION OPTIMIZATION OF A 150 MW (NET) BOILER UTILIZING AIR AND FUEL FLOW MEASUREMENT AND CONTROL

Analysis O2, CO, CO2. Applications. Characteristics. System. Air monitoring. Measurands O 2, CO, CO 2. Measurement in liquids

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Standard Continuous Emissions Monitoring System (CEMS)

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Handheld Transit-Time Ultrasonic Flowmeter

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

Just a few clicks away from a heating system

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

Moisture analyzers (moisture meters) FIZEPR-SW100

Transcription:

CH88 Combustion Flue Gas Oxygen Analyzer System CMB-PDS-CH88 Product Data Sheet September 2017 CH88 In Situ Flue Gas Oxygen Transmitter World-Class TM performance Outstanding accuracy ±1% full scale 1056 Combustion local operator interface, with large backlit LCD display Adaptable to any existing O 2 probe installation Westinghouse World Class Rosemount Oxymitter Most competitive O 2 Probe installations Accurate, reliable combustion measurement of combustion flue gas excess oxygen The CH88 in situ O 2 transmitter provides accurate measurement of the oxygen remaining in the flue gases coming from any combustion process. Optimal combustion efficiency can be obtained by controlling fuel/air ratios to maintain the ideal level of oxygen in the flue gases coming from these processes. Additionally, the lowest levels of NOx, CO, and CO 2 are produced. Easy to use and easy to integrate. This in situ analyzer was designed with customer ease-of-use in mind. There are no moving parts or sampling apparatus, resulting in an extremely reliable probe that requires very little maintenance.

CH88 Combustion Flue Gas Oxygen Analyzer System September 2017 The latest breakthrough for combustion flue gas analysis The CH88 in situ O 2 analyzer provides accurate measurement of the oxygen remaining in the flue gases coming from any combustion process, including: Boilers Kilns Incinerators Process heaters Industrial heating furnaces By maintaining the ideal level of oxygen in the flue gases coming from these processes, optimal efficiency is gained, and the lowest levels of NOx, CO, and CO 2 are produced. Power This in situ design places a zirconium oxide sensing element at the end of a probe, which inserts directly into a flue gas stream. There are no moving parts or sampling apparatus, resulting in an extremely reliable analyzer that requires very little maintenance. Probe lengths are available from.5 m to 2 m. Accessories are available for process temperatures between 700 C and 1050 C (1292 F and 1922 F). Calibrations may be performed on-line, while the furnace is in operation. The 1056 Combustion electronics provides a convenient method for setting up and operating the CH88 analyzer. A bright back-lit display and keypad make calibrations easy. Industrial Steam Lime/Cement Steel 2 www.emerson.com/rosemountliquidanalysis

September 2017 CH88 Combustion Flue Gas Oxygen Analyzer System 1056 combustion electronics The 1056 combustion electronics provide a bright back-lit display and an easy-to-use keypad. These electronics make setup, calibration, and operation of this O 2 system easy and also provide extensive diagnostics of any problem with the probe or electronics. www.emerson.com/rosemountliquidanalysis 3

CH88 Combustion Flue Gas Oxygen Analyzer System September 2017 Specifications System measurement specifications Net O 2 range Variable 0-10% to 0-50% Accuracy in oxidizing conditions ±1% full scale for 0-10% range and above Lowest detectable limit 0.05% Process temperature effect less than 0.05% O 2 from 100 to 700 C (212 to 1292 F) System speed of response to calibration gas Initial response in less than 3 seconds, T90 in less than 8 seconds. Response to process gas changes will vary depending on process gas velocity and particulate loading of the diffuser Calibration validity Presentation of calibration gases matches the bottle value to within ±0.1% O 2 Environmental specifications Probe Probe Process-wetted materials are 304 stainless steel Process temperature limits -40 to 705 C (-40 to 1300 F) optional bypass and jacket accessories permit operation to 1050 C (1922 F) Probe terminations CH88 probe ambient temperature limits -4 to 90 C (-40 to 194 F) 1056 combustion electronics Polycarbonate material 1056 combustion ambient temperature limits -20 to 50 C (-4 to 122 F) Installation Specifications Probe Probe mounting flange Vertical or horizontal 2" 150# (4.75" (121mm) bolt circle) and DIN145 Note: Flanges are flat-faced, and for mounting only. Flanges are not pressure-rated. A 2.5" diameter hole in the process is required. Spool piece P/N 3D39761G02 is available, to offset probe housing from hot ductwork. Many adapter flanges are available to mate to existing flanges. Probe lengths and approximate shipping weights.5 m (19.68 in.) package: 7.3 kg (16 lb) 1 m (39.37 in.) package: 9.5 kg (21 lb) 2 m (78.74 in.) package: 12.2 kg (27 lb) Reference air No instrument air required. Ambient air diffuses into the probe passively. Ensure that ambient air is fresh (20.95% O 2 ) Calibration Semi-automatic manual gas switching. New calibration values are calculated in the 1056 Combustion electronics. Cal gases.4% and 8% O 2, balance N 2 recommended. Instrument air may be used as a high cal gas, but is not recommended. 100% nitrogen cannot be used as the low cal gas. Calibration gas flow 5scfh (2.5l/min) Heater electrical power 220V ±10%, 50 Hz Traditional architecture cable Customer supplied Power consumption of probe heater 150 watts max. during initial warm-up 4 www.emerson.com/rosemountliquidanalysis

September 2017 CH88 Combustion Flue Gas Oxygen Analyzer System Specifications Installation specifications 1056 combustion electronics Electrical power of 1056 combustion electronics 220V ±10%, 50 Hz Power consumption of 1056 combustion electronics 150 Watts during initial warm-up Analog output 4-20 ma. max load 550 ohms 1056 combustion alarms relays 2 provided 5 A, 30 Vdc, 120 Vac, or 230 Vac 1056 combustion alarms relays Customer supplied cable recommended Probe sensing cable 3 twisted pair; 16 to 24 ga., shield connected to ground at 1056 combustion electronics. Heater cable 12-18 ga. power cable For lengths 200 and 500 feet use 16 to 22 ga. signal wires and 12 to 14 ga. heater wires www.emerson.com/rosemountliquidanalysis 5

CH88 Combustion Flue Gas Oxygen Analyzer System September 2017 Dimensional drawings Probe installation dimensions Note: All dimensions are in meters with inches in parentheses. Removal/installation Probe length Removal envelope.5 m (19.68 in.) 750 mm (30 in.) 1 m (39.37 in.) 1250 mm (49 in.) 2 m (78.74 in.) 2250 mm (89 in.) 6 www.emerson.com/rosemountliquidanalysis

September 2017 CH88 Combustion Flue Gas Oxygen Analyzer System Dimensional drawings CH88 probe installation dimensions Note: All dimensions are in meters with inches in parentheses Mounting flange Flange dia Hold dia (4) Holes Eq Sp on BC ANSI 120.7 mm (4.75 in.) 185 mm (7.28 19.1 mm ) (.75 in.) DIN 145 mm (5.71 in.) Square weld plate, ANSI pattern, Part 4512C34G01 Square weld plate, DIN pattern, Part 4512C36G01 www.emerson.com/rosemountliquidanalysis 7

CH88 Combustion Flue Gas Oxygen Analyzer System September 2017 Dimensional drawings Xi Enhanced Interface - Panel Mounting Details Xi Enhanced Interface - Wall/Surface and Pipe Mounting Details