a. Each land-based portable or mobile element of a marine vapor control system that connects to or from a vessel.

Similar documents
MSC Guidelines for the Review of Inland Tank Barge Cargo Authority

Safety Standards for LNG Fueled Vessels

CHEMICAL TANK VESSEL INFORMATION SHEET (CTVIS)

Detachment Chief United States Coast Guard Liquefied Gas Carrier National Center of Expertise

United States of America Department of Homeland Security United States Coast Guard Certificate of Inspection

MSC Guidelines for Review of Ventilation System Plans

Maritime Energy Transport Regulatory Overview and Status

16715 CG-OES Policy Letter No

Marine Vapor Emission Control Systems

DECLARATION OF INSPECTION

U. S. Coast Guard Sector

Crane Certification FAQs

NAVIGATION AND VESSEL INSPECTION CIRCULAR NO BACKGROUND.

FACILITY RESPONSE PLAN REVIEW CHECKLIST

Dry Cargo Residue (DCR) April 2016

A.6 Boilers. A.6.1 New and Existing Boilers located within AQCR 131

MSC Guidelines for Review of IMO High-Speed Craft Code General Arrangements, Structural Fire Protection, and Means of Escape

Subpart G Emergency Response Information

e-cfr Data is current as of October 16, 2017

Cranes and Derricks Standard Summary. April, 2010

GUIDELINES FOR INSTALLATION OF ABOVEGROUND DIESEL FUEL TANKS

This electronic edition is licensed to for 1 copy. International Maritime Organization

Resolution MEPC.11(18) adopted on 25 March 1983 GUIDELINES FOR SURVEYS UNDER ANNEX I OF THE INTERNATIONAL CONVENTION FOR THE PREVENTION OF POLLUTION

JULY 10, 2013 INTRODUCTION

Pipeline Status Document. API Document AUGUST 2017

4.0 PLACARDING STUDENT WORKBOOK

CONTAINER INSPECTION JOB AID

REPUBLIC OF ALL SHIPOWNERS, OPERATORS, MASTERS AND OFFICERS OF MERCHANT SHIPS, AND RECOGNIZED ORGANIZATIONS

FACILITY SECURITY PLAN (FSP) REVIEW CHECKLIST


U. S. Coast Guard Sector

SOLAS VGM FAQs Frequently asked questions about the new verified gross mass requirement from the Safety of Life at Sea convention

Stowage of Explosives on Vessels and issues noted with Small Ships

INDUSTRIALIZED HOUSING AND BUILDINGS Administrative Rules of the Texas Department of Licensing and Regulation 16 Texas Administrative Code, Chapter 70

Addition to Section 4 - Special Use Regulations

The following definitions apply with regard to requirements specified in this document:

Vessel Acceptance Policy

CITGO PETROLEUM CORPORATION CORPUS CHRISTI MARINE FACILITY REGULATIONS FOR VESSELS

CHAPTER 604 INTERMODAL CONTAINER INSPECTION, REINSPECTION, MAINTENANCE, AND REPAIR

MTSA FACILITY COMPLIANCE GUIDE

SAN FRANCISCO PUBLIC UTILITIES COMMISSION INFRASTRUCTURE CONSTRUCTION MANAGEMENT PROCEDURES

Commandant United States Coast Guard

FAIRCHILD APPLICATION FOR EMPLOYMENT

BULK LIQUID FACILITY INSPECTION JOB AID

N.J.A.C. 7:14A-1 POLLUTANT DISCHARGE ELIMINATION SYSTEM SUBCHAPTER 21. REQUIREMENTS FOR INDIRECT USERS

RULE 2250 PERMIT-EXEMPT EQUIPMENT REGISTRATION (Adopted October 19, 2006)

MOL Liner Ltd. Guidelines for Improving Safety and Implementing the SOLAS Container Weight Verification Requirements

POLICY ADVISORY COUNCIL (PAC) DOCUMENT REGISTRY

Fisheries off West Coast States; Highly Migratory Fisheries; California Swordfish Drift Gillnet

MEMORANDUM Via

New Zealand Technical Standard Order NZTSO 2001

DEPARTMENT OF TRANSPORT

(Acts whose publication is obligatory)

Pre-Publication Draft - September 21, 2016 APD MARINE LOADING COLLECTION EFFICIENCY GUIDANCE

Recommendations For Reporting Mobile Refueling Vehicles & Portable Trailer-Mounted Generators At Fixed Facilities

SEVENTEENTH DISTRICT MARINE SAFETY INFORMATION BULLETIN (MSIB) ALTERNATIVE PLANNING CRITERIA GUIDELINES FOR NON-TANK VESSELS IN ALASKA

PART 11. OTHER SOLID WASTE INCINERATION UNITS [NEW]

Retail Food Establishment. Self-Assessment Checklist. for. Food Defense

Hazardous Waste Small Quantity Generator Checklist

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

LARGE QUANTITY GENERATOR (LQG) OF HAZARDOUS WASTE

COMPLIANCE ASSISTANCE VISIT REPORT

SANTA BARBARA COUNTY AIR POLLUTION CONTROL DISTRICT POLICIES AND PROCEDURES. Policy No Draft Div Pol Yr

Sector Houston Galveston Captain Brian Penoyer Sector Commander

THE REPUBLIC OF LIBERIA Bureau Of Maritime Affairs

EMPLOYEE R-T-K, EMPLOYEE TRAINING, AND TRAINING RECORDS

Advisory Circular. Date: DRAFT Initiated by: AIR-110

C-TPAT Security Criteria. Sea Carriers

House Bill 4086 Ordered by the House February 21 Including House Amendments dated February 21

DEPARTMENT OF THE AIR FORCE HEADQUARTERS AIR FORCE CIVIL ENGINEER SUPPORT AGENCY

Cargo Handling Sheet. Non-Shell Product. KLK Oleo PALMERA G997U (Glycerin USP 99.7%) Document Date: 22 December 2017 Revision 1

Apache / Contractor X. Contractor/Vendor Bridging Document

Texas Commission on Environmental Quality Page 1 Chapter Industrial Solid Waste and Municipal Hazardous Waste

Applicant s Name: Visit to get a check done electronically.

TONNAGE MEASUREMENT RECORDS

) ) ) ) ) ) ) ) ) ) ) ) PCAOB Release No June 9, 2004

Prepared for Unmanned Surface Vessel Regulation Conference. Southampton October 2016

Formal Interpretation NFPA 30. Flammable and Combustible Liquids Code Edition

SECTION 4 MANAGEMENT OF CHANGE OCS Production Operations

TITLE 35 LEGISLATIVE RULES BUREAU OF ENVIRONMENT DIVISION OF ENVIRONMENTAL PROTECTION OFFICE OF OIL AND GAS

California TRU Guidance

Precision Automatic Vacuum Control (PAVC+)

VALLEY LATERAL PROJECT. RESOURCE REPORT 11 Reliability and Safety. FERC Docket No. CP

AMERICAN WOOD PROTECTION ASSOCIATION STANDARD 2010 All Rights Reserved

Clarifications and Directives from the RCP Standards Board Meeting, November 29-30, 2016

LNG Operations: safety issues and procedures. Styliadis, Theodore Koliousis, Ioannis Deparment of Maritime Studies University of Piraeus

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

2012 VIRGINIA INDUSTRIALIZED BUILDING SAFETY REGULATIONS

STANDING ADVISORY GROUP MEETING

Transportation and Transfer of Ethanol-Blended Fuels

502(b)(10) Permit for Part 70 Source

Commonwealth of Massachusetts DEPARTMENT OF HOUSING & COMMUNITY DEVELOPMENT Deval L. Patrick, Governor Aaron Gornstein, Undersecretary FOR

DGI Training Center HAZARDOUS MATERIALS TRANSPORTATION COMPLIANCE AUDIT CHECKLIST. Company: Contact: Contact Phone: Contact Audit Address:

ASB Meeting January 12-15, 2015

A Technical Publication from the Co-ordination and Information Centre. Transportation of Propane Cylinders and Bulk Tanks by Road

ORGANIZATIONAL CHANGES

Toxic Flammable Gas Release From Rail Car Results in 3 Fatalities

June 20, Transportation Worker Identification Credential Reader; Notice of Proposed Rulemaking RIN 1625-AB21

SIMPLIFYING THE VGP AND EALS

FREQUENTLY ASKED QUESTIONS Instruments of International Traffic Imported into the United States with Residue February 3, 2012

Transcription:

Commandant United States Coast Guard 2703 Martin Luther King Jr. Ave,S.E. STOP 7509 Washington, DC 20593-7509 Staff Symbol: CG-ENG Phone: (202) 372-1412 Fax: (202) 372-8380 From: To: J. W. Mauger, CAPT COMDT (CG-ENG) Distribution Subj: Ref: INTERIM GUIDANCE FOR REGULATED FACILITIES FOR THE REVIEW AND APPROVAL (a) Title 33 of the Code of Federal Regulations (33 CFR) Part 154 Facilities Transferring Oil or Hazardous Materials in Bulk (b) Final Rule: Marine Vapor Control Systems, published in the Federal Register, 16JUL2013 (c) Certifying Entity Guidelines for Conducting a Review, Certification and Initial Inspection of Waterside Facility Vapor Control Systems, Change (1), dated 4 October 1991 Purpose. This policy letter provides interim guidance to Coast Guard Captains of the Port (COTPs) to assist in the assessment of equivalency requests from regulated facilities to use mobile or portable vapor control systems (VCSs) in lieu of fixed VCSs. All requirements as set forth in Title 33 of the Code of Federal Regulations (33 CFR) Part 154 Facilities Transferring Oil or Hazardous Materials in Bulk (reference (a)) and the updated regulations published in the Federal Register (reference (b)) apply to mobile VCSs and portable elements of a VCS. For the purposes of this letter, the term mobile generally refers to a marine vapor control system being mounted on a truck or trailer chassis while in use and portable generally refers to a marine vapor control system being mounted on skids while in use. Mobile or portable facility VCSs can include, but are not limited to: a skid mounted dock safety unit (DSU), a truck mounted vapor combustion unit, also referred to as a vapor destruction unit (VDU) or vapor collection unit (VCU), vapor recovery unit, or vapor balancing system. 1. Directives Affected. None. 2. Applicability. This policy letter applies to: a. Each land-based portable or mobile element of a marine vapor control system that connects to or from a vessel.

b. Each land-based portable or mobile element of a marine vapor control system that connects to a facility used or capable of being used to conduct cleaning operations on a tank barge. c. Each land-based portable or mobile element of a marine vapor control system that is used in salvage or emergency operations. d. This policy letter does not apply to multi-breasted barge tandem loading operations under vapor control. 3. Action. a. COTPs should use this guidance when evaluating requests to operate mobile or portable vapor control systems and associated equipment at a facility. All vapor control systems and associated equipment, portable or fixed, must be designed, installed, and operated in accordance with 33 CFR 154 subpart P. Alternative compliance requests must demonstrate that the alternative provides an equivalent level of safety and protection per 33 CFR part 154.107(a)(1-3). b. Commandant (CG-ENG-5) will continue to consider exemption requests on a case-bycase basis. 4. Background. a. In accordance with 33 CFR 154.107, COTPs have received requests from industry for approval of alternative procedures, methods, and equipment standards on mobile and portable VCS systems. Common issues and interpretations include the following: i. Portions of industry have interpreted the omission of the terms mobile and portable from 33 CFR 154 as meaning that mobile VCSs do not have to comply with the regulations in 33 CFR 154. However, all regulations within 33 CFR part 154 apply to mobile or portable VCSs, and any elements of a mobile or portable VCS. Any mobile VCS that cannot meet all of the requirements in 33 CFR part 154 must apply for an alternative compliance request from their COTP or an exemption waiver from the Commandant. ii. Requests have been submitted to use the vessel s VCS equipment and piping during transfer operations instead of the regulated facility s VCS setup. The intent is to connect their portable vapor destruction unit to the vessel s VCS to collect vapors and to use their personnel to monitor the equipment and operations. This does not offer the same fire, explosion, and detonation protection installed at the facility and required by 33 CFR 154 subpart P. Arrangements which use vessel equipment to meet facility requirements are not permitted. 2

iii. Requests have been submitted to replace required equipment or design installation with personnel monitoring radio communications. Please refer to Paragraph 5.c.iv. iv. Companies state that a Certifying Entity (CE) certification is not necessary because mobile VCSs are not specifically named in references (a)-(c). Please refer to Paragraph 5.c.i. b. Increased used of mobile and portable VCS resulted in numerous clarification requests from industry representatives. This motivated the Coast Guard to seek assistance from the advisory committees TSAC and CTAC. The finalized recommendations from industry, completed in April 2014, clarified standards for the safe design, installation, and operation of mobile and portable vapor control systems. This policy letter aims to incorporate these changes and guide COTPs in analyzing industry alternative requests. 5. Discussion. a. Definition: 33 CFR part 154.2001 defines a VCS as an arrangement of piping and equipment used to control vapor emissions collected from a vessel and includes the vapor collection system and vapor processing unit. See 33 CFR part 154.2001 for additional VCS definitions. Mobile and portable VCS refers to any land-based marine vapor control system (VCS) designed to be deployed to a facility. This includes: i. mobile vapor destruction units, ii. portable dock safety skids, iii. vapor recovery units, and iv. vapor balancing systems b. VCS - installed vs. temporary: 33 CFR part 154.2000(a)(1) specifies that 33 CFR part 154 subpart P applies to each facility which controls vapors emitted to or from vessel cargo tanks regardless of transportable status. The regulation does not distinguish a mobile or portable system or element from a permanently installed and fixed VCS. Therefore, 33 CFR part 154 applies to all VCSs, including all elements of a VCS, mobile or fixed. c. Alternatives: In accordance with, 33 CFR part 154.107 a COTP can approve alternative compliance requests that provide an equivalent level of safety and protection. The following conditions apply to proposed alternatives. 3

i. Certification by a Certifying Entity (CE): Any alternative, where equipment required by the regulations is replaced by equipment that differs from the regulations but has the same purpose, must be recertified by a Coast Guard approved CE (reference (c)). In the case where portable equipment is attached to an existing fixed VCS, a CE must certify that the portable equipment and its installation comply with the requirements of 33 CFR part 154 subpart P. ii. The Coast Guard recognizes that portable equipment (namely Vapor Destruction Units, or VDUs) may not meet all regulatory requirements within subpart P. Therefore, a CE certification is not possible for those systems. CG-ENG-5 strongly recommends that COTPs require the owner/operator to complete a failure analysis or comprehensive safety assessment of the portable equipment including: VDUs, mobile or portable VCS, and/or a combination of fixed and mobile and portable components. The system-specific qualitative failure analysis should be completed in accordance with the American Institute of Chemical Engineers publication, Guidance for Hazard Evaluation Procedures. The results must be submitted to the COTP for review and discussion. iii. Site certification and equipment certification: The Coast Guard recognizes that mobile and portable VCSs can be moved from site to site and from facility to facility. Rather than requiring a CE to certify each mobile or portable unit at each site, a twostep solution may be implemented: (i) The total VCS unit can be viewed as two pieces: a. Mobile unit. The mobile unit is certified to operate within a specified range of tested and verified operating conditions. These conditions must be met for any site where a unit will operate. Only one unit would have to be certified for any series of identical units. Additionally, each unit would have to be tested to verify that it can meet the entire range of operating conditions while units constructed as the same model can all operate under the same certification. As part of the certification procedure, the CE should document and provide the testing procedures for subsequent identical units. b. Site. Each site should be certified for a certain range of operating conditions. Each site needs an initial certification, with recertification necessary if significant changes are made. (ii) When a site requires a mobile VCS unit, any mobile unit certified for the site s operating conditions can be used. Conversely, a mobile unit can deploy to any site whose operating conditions match its certification. 4

(iii) It is imperative that the range of certified operating conditions from the site fall within the certified operating conditions of the mobile unit. (iv) The pre-startup checklist must be completed and reviewed by the facility, equipment and vessel operators before transfer operations can take place. (v) The mobile and portable VCSs may have equipment that requires repeated, routine assembly and disassembly. At the certification of the mobile unit, the CE should determine the level of oversight that the assembly process will require depending upon the degree of assembly needed. Similar to 33 CFR 154.2023, the CE should determine if the assembly would qualify as a design or configuration alteration. This assessment will establish the degree of oversight required. For mobile or portable units with limited assembly, a checklist or verification by a qualified individual may be acceptable. For example, mobile unit/site combinations that merely require the same connections as fixed VCS sites would not need any extra oversight beyond that for a fixed VCS. A higher level of oversight would be required for a mobile unit/site combination that requires additional connections beyond what is typical of a standard fixed VCS site. The approved alternative connections of the mobile or portable unit to the site must be as safe as the fixed VCS facility connections. iv. Design installation and operations: Under 33 CFR 154.2100(a), every VCS is required to have three levels of protection: design and installation, protection system designs, and operational requirements. A mobile or portable system or element submitted for approval must have an equivalent level of safety and protection. An operational measure cannot replace a protection system design, i.e. remote indicators, overfill protection panels and alarms, and/or pressure sensing devices, cannot be replaced with personnel monitoring radio communications. Requests for alternative compliance approvals must be submitted to the local COTP. d. Exemptions: Any exemptions to 33 CFR part 154 must be forwarded to CG-ENG-5, in accordance with 33 CFR part 154.108. i. Vessel VCS vs. Facility VCS: As required by 33 U.S.C 1231, Coast Guard VCS regulations place the responsibility of protecting tank vessels from overfill hazards, overpressure and over vacuum hazards, and fire, explosion, and detonation hazards on the facility instead of on the vessel. As stated in 5.c.iv a substitution of operational methods for required equipment to affect the control of vapors is not authorized. Automatic alarms and shutdowns, pressure sensing devices, inerting, enriching, and diluting systems provide operators real-time indications to ensure that the tank vessel is protected from any issues on the facility side. Any alterations to design, construction or equipment on the facility side should be replaced with an equivalent method or measure. 5

ii. The piping and fitting requirements in 33 CFR 154.2100(b) may be difficult to meet for the interconnection between each portable or mobile component of the VCS. If vapor piping is used, it must comply with the regulations within 33 CFR 154.2100(b). Nonmetallic/metallic hose may be used for the connections between each component provided each section of nonmetallic/metallic hose meets the requirements in 33 CFR 154.500. When nonmetallic/metallic hoses are used in a mobile or portable VCS, the following safety guidelines must be followed: (i) Vehicular traffic may not be allowed within 25 feet of any hose section. (ii) Hoses must be properly supported and without damage. (iii) All hoses must be color coded to identify them as vapor recovery components with proper red and yellow markings, in accordance with 33 CFR 156.170. (iv) Traffic cones or other high visibility markers shall be used to identify the location of the hoses. e. Training: Training to set up, operate, and dissemble the mobile or portable VCSs must be in accordance with 33 CFR 154.2030 and 33 CFR 154.710. i. Equipment owners who provide and keep trained operators with the portable units at facilities must ensure that all operators have completed company and equipment specific training, as well as the training requirements in 33 CFR 154.710 and.2030. ii. Companies that have portable systems that they lease to a facility must provide a trainer versed in the regulations and the equipment to train and qualify the facility user. The training must cover all elements within 33 CFR 154.710 and.2030 for the equipment and must include three movements 1 /transfers between a vessel and the portable or mobile units. A certifying entity must observe the first loading movement. Once the user has been qualified and completed three successful movements, he/she can then train additional facility employees. The qualified users should be requalified once every three years by the equipment owner, with the scope of re-testing to encompass 33 CFR 154.710(c)-(d). f. Allotted period of use: There is no restriction on the duration of use of mobile VCSs provided the mobile VCS has undergone review and approval by a CE. The local COTP can inspect the mobile VCS at a frequency they deem adequate. 1 A movement consists of the initial setup of equipment, communication between vessel and facility parties to complete the Declaration of Inspection, all requirements listed in 33 CFR 156.120, transfer of cargo, shutdown procedures, and disassembling of equipment. 6

g. Emergency situations: In the event of an emergency situation requiring the use of mobile or portable VCSs, owners/operators must contact the local COTP to address additional safety concerns. Because the units are pre-certified for use, the only requirements would be CE certification of the site (if it has not been previously conducted) and the completed pre-startup checklist. Special consideration needs to be given for emergency operating conditions (i.e. distance of hoses, seal pots operating on unstable surface, etc.) by the CE. In the event that ICP has been established, the operations section chief needs to approve the operational procedures and set-up. h. Security Requirements: Facility operators adding a mobile VCS or a portable element to an existing fixed VCS system should review their Facility Security Assessment and propose any appropriate amendments to their Facility Security Plan to the COTP. i. Enforcement: If a VCS is discovered to be in use with a mobile component that has not been reviewed by a CE, the COTP can exercise authority under 33 CFR part 154.700 to suspend or otherwise control facility operations until satisfied that the configuration does not compromise the facility or port s safety. j. Policy promulgation: This policy letter is intended for interim guidance only. The Coast Guard fully recognizes the need to facilitate commerce, as well as the final authority of COTPs for approving alternative requests. 6. Disclaimer. While the guidance contained in this document may assist the industry, public, Coast Guard, and other Federal and State regulators in applying statutory and regulatory requirements, the guidance is not a substitute for applicable legal requirements nor is it a regulation itself. Thus, it is not intended to, nor does it impose legally binding requirements on, any party outside the Coast Guard. 7. Changes. This policy letter will be posted on the web at http://www.uscg.mil/hq/cg5/cg521/. Changes to this policy will be issued as necessary. Suggestions for improvements of this policy should be submitted in writing to this office. Enclosure: (1) Mobile or Portable VCS Pre-Startup Checklist Dist: COMDT (CG-FAC) COMDT (CG-OES) CG MSC, Tank Vessel and Offshore Division All Sectors/MSUs/MSDs (p) (r) (cc) # 7

Company Name Enclosure (1) to 01-15 Mobile or Portable VCS Pre-Startup Checklist System/Location: Procedure No. PENDING Revision No: Revision Date: Page: 1 of 2 Mobile or Portable Vapor Control System (VCS) Pre-Startup Checklist Purpose: For the purpose of this checklist, the term mobile generally refers to a marine vapor control system being mounted on a truck or trailer chassis while in use and portable generally refers to being mounted on skids while in use. All requirements in 33 CFR, Part 154 apply to mobile and portable VCS. For more information, see USCG Interim guidance for the safe operation of mobile vapor control systems. Applicability: This checklist applies and must be completed by owner/operator of: i. Each land-based portable or mobile element of a marine vapor control system that connects to or from a vessel. ii. Each portable or mobile element of a marine vapor control system that connects to a facility used or capable of being used to conduct cleaning operations on a tank barge. iii. Each portable or mobile element of a marine vapor control system that is used in salvage or emergency operations. Note: This does not apply to multi-breasted barge tandem loading operations under vapor control. Additional requirements may also apply for salvage or emergency situations as directed by local Captain of the Port (COTP) and Certifying Entity (CE). 8

Mobile or Portable VCS Pre-Startup Checklist TIME: VESSEL NAME / NUMBER: TANK NUMBER: DATE: LOCATION: Description 1. Verify that location of Mobile or Portable Vapor Control System (PVCS) has been approved by USCG and Certifying Entity (CE). 2. Verify the PVCS has been approved by USCG and CE for the site conditions. 3. Verify that site and/or mobile (e.g. barge deck) conditions and location approval have been adhered to. 4. Verify enrichment gas composition to ensure it is compatible with system components. 5. Review VCS chemical approved lists (PVCS unit, vessel and fixed site, if applicable), certificate of inspection (COI), and last product transferred to ensure chemical compatibility. 6. Verify that all equipment has been tested and inspected in accordance with 33 CFR, Part 154. This includes testing required by 33 CFR, Part 154.2150 for pressure sensors, alarms, automatic shutdown systems, analyzers, etc., required not more than 24 hours before each transfer. 7. Verify that adequate containment is available (if necessary). 8. Are insulating flanges being used? Yes No Note: Verify that hoses/piping is electrically discontinuous. 9. Verify that transfer is electrically continuous by conducting continuity test and ensure all equipment/components are adequately grounded and bonded. 10. Verify that interface connection to liquid cargo valve has been tested (if present and being used). 11. Verify that declaration of inspection (DOI) has been executed between facility and vessel personnel. INITIAL 9