PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Similar documents
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Addendum No. 1. ITB for Emergency Management/Utilities Administration Building Renovation Addendum Release Date April 06, 2017

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION

DRAFT NOTICE OF ACCEPTANCE (NOA)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

CBUCK Engineering. Product: Zee-Lock Roof Panel Material: Steel Panel Thickness: 24 gauge Panel Width: 16 Support: Wood Deck

PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

CBUCK Engineering. Evaluation Report Cee Lock Panel Metal Roof Assembly

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

Miami Dade Building Code Compliance Office Notice of Acceptance

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

CBUCK Engineering. Evaluation Report Englert Series 500 Metal Roof Assembly Manufacturer: Englert, Inc Amboy Avenue Perth Amboy, NJ

Residential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

Evaluation Report. Die Formed Skirt Ridge Ventilator. "12 Inch Throat" Manufacturer. Metallic Products Corporation Hollister Road

CBUCK Engineering. Florida Product Approval # FL R2

MILLENNIUM METALS, INC TEST REPORT

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

technical bulletin ROOFING CORPORATION

Code Compliance Research Report CCRR-0228

EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

technical bulletin ROOFING CORPORATION

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

TECHNICAL INFORMATION

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

Scope. Definitions. For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building.

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER:

INSTALLATION GUIDE.

Pacific Tile Counter Batten and Batten

EVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR DESCRIPTION: Tarco Roof Underlayments

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

Western States 7/8 Corrugated

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

Re-Roof Permit Checklist

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

ALLMET CONTINENTAL INSTALLATION GUIDE

SL175 Panel Technical Data Guide

TRIAD CORRUGATED METAL, INC.

CS-100 Guide Specifications

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: BRICK-IT. SERIES/MODEL: Brick Veneer Panel Systems PRODUCT TYPE: Wall Panel Systems

Evaluation Report SkylightTube Tubular Daylight Device

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

ROOFING APPLICATION STANDARD (RAS) No. 120 MORTAR AND ADHESIVE SET TILE APPLICATION

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

ATI Evaluation Service A Division of Architectural Testing Certification Services

Originally Issued: 09/19/2014 Revised: 10/17/2017 Valid Through: 11/15/2017

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

DESCRIPTION: Eagle Roof Tiles

DAN S CUSTOM SHEETMETAL Manufacturer and Distributor

SHEET METAL ROOF TEST REPORT

EVALUATION REPORT GAF 1361 Alps Road, Building 7-3 Wayne, NJ 07470

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

Originally Issued: 03/27/2015 Revised: 10/17/2017 Valid Through: 03/31/2018

RESIDENTIAL ROOFING PRODUCT GUIDE

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708

Force Engineering & Testing Inc Ramblewood Drive. Humble,TX Product Evaluation Report SENTRIGARD METAL ROOFING SYSTEMS

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

TEST PROCEDURE FOR AIR PERMEABILITY TESTING OF RIGID, DISCONTINUOUS ROOF SYSTEMS

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

PROJECT STATEMENT OF WORK ROOFING PHASE AREA CAMP BLANDING JOINT TRAINING SITE STARKE, FL 32091

SECTION METAL ROOF PANELS

PBR & PBU PANELS. Technical/Installation Information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

SNAP-CLAD. Technical Information and Flashing Details. /

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

ROOFING PERMIT APPLICATION PACKAGE

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Transcription:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/pera NOTICE OF ACCEPTANCE (NOA) Berridge Manufacturing Company 1720 Maury Street Houston, TX. 77026 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: S-Tile 24 Gauge Steel Roof Panel LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 11-0818.06 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. Page 1 of 7

ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub-Category: Non-Structural Metal Panels Material: Steel Deck Type: Wood Maximum Design Pressure -206 psf. (See System Limitation #2) TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: S-Tile Product Dimensions Test Specifications l = various w = 32-11/16 Thickness 0.024 (24 ga.) Strength: 64.2 ksi TAS 110 TAS 125 Product Description G-90 galvanized or AZ-55 galvalume panels with various approved coatings Fluropon, Kynar, or Hylar Trim Pieces l = varies w = varies Thickness 0.024 (24 ga.) N/A Standard flashing and trim pieces. Manufactured for each panel width. MANUFACTURING LOCATION: 1. Houston, TX. 2. San Antonio, TX. 3. Seguin, TX. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PPG Industrial Coatings Test Lab Certification ASTM B117 Test Lab Certification ASTM G152 ASTM G153 Force Engineering & Testing, Inc. 49-0297T-10A-C TAS 125 09/30/10 PRI Construction Materials Technologies BMC-010-02-01 TAS 100 04/11/11 Page 2 of 7

APPROVED ASSEMBLY: SYSTEM A: Deck Type: Deck Description: Slope Range: Maximum Uplift Pressure: Deck Attachment: S-Tile Metal Panels Wood, Non-insulated 19 / 32" or greater plywood or wood plank. 2": 12" or greater See Table A below In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced as listed below in Table A. In reroofing, where the deck is less than 19 / 32 thick (Minimum 15 / 32 ). The above attachment method must be in addition to existing attachment. TABLE A Roof Areas Field Perimeter and Corner Maximum Plywood Deck Fastener Spacing 6 o.c. 3 o.c. Underlayment: Minimum underlayment shall be a ASTM D 226 Type II installed with a minimum 4 side-laps and 6 end-laps. Underlayment shall be fastened with corrosion resistant tincaps and 1¼ annular ring-shank nails, spaced 6 o.c. at all laps and two staggered rows 12 o.c. in the field of the roll. Or, any Miami-Dade County Product Control Approved underlayment having a current NOA. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Berridge Manufacturing Company s current published installation instructions. Fire Barrier Board: Metal Shingles and Accessories: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Install the "S-Tile Panel" and accessories in compliance with the current published installation instructions and details in Berridge Manufacturing Company s Installation Manual. Flashings, penetrations, valley construction and other details shall be constructed in compliance with Roofing Application Standard RAS 133. Fasteners shall be installed in the valleys of the panel corrugations with corrosion resistant #14-10 self-drilling HWH screws with self-sealing washers of sufficient length to penetrate through the sheathing a minimum of 3 / 16". Fastening shall be in accordance with Table B herein. Sidelaps shall be attached with ¼ 14 x 7/8 HWH screws with self-sealing washers 14 o.c. (at every tile step). Page 3 of 7

TABLE B MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner 1 Maximum Design Pressures 134.75 psf 206 psf Maximum Fastener Spacing Refer to Drawing Detail A Refer to Drawing Detail B Maximum Row Spacing 14 o.c. (every tile step) 14 o.c. (every tile step) 1. Extrapolation shall not be allowed Page 4 of 7

SYSTEM LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer s name and/or logo, and the following statement: Miami-Dade County Product Control Approved or with the Miami-Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer s name and/or logo, and/or model. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. GENERAL LIMITATION 1. An original signed and sealed company letter from Berridge Manufacturing Co. is required, proving that the S-Tile Roof Panel System was purchased from Berridge Manufacturing Co. in order for this NOA to be valid on any job. PROFILE DRAWINGS 32-11/16" Coverage 1-1/2" S-TILE PANEL Page 5 of 7

DETAIL A TYPICAL FASTENING PATTERN ACROSS PANEL PROFILE - FIELD CONDITION 13" (every other valley) Panel to Deck Screw: #14 Hex-Head Screw with WSW 19/32" Plywood Deck Side-Lap Screw: 1/4" Hex-Head Screw with WSW Side-Lap: 1/4"Hex-head with WSW Panel to Deck: #14 Hex-Head with WSW 13" Underlayment 14" Plywood Deck "S-Tile" Page 6 of 7

DETAIL B TYPICAL FASTENING PATTERN ACROSS PANEL PROFILE - PERIMETER AND CORNER CONDITION 6-1/2" (Every Valley) Panel to Deck Screw: #14 Hex-Head Screw with WSW 19/32" Plywood Deck Side-Lap Screw: 1/4" Hex-Head Screw with WSW Panel to Deck: #14 Hex-Head with WSW 13" Side-Lap: 1/4" Hex-head with WSW Underlayment 14" Plywood Deck "S-Tile" END OF THIS ACCEPTANCE Page 7 of 7