Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Third Issue September 2017

Similar documents
First Issue March 2013 AN INTRODUCTION. Low Energy Low Carbon Buildings

Insulation. A4/8 KDINT AW2143 Issue 4 Oct An Introduction

Insulation TECHNICAL DATA SHEET. Low Energy Low Carbon Buildings. CI/SfB (57.9) In7 (M2) First Issue April 2016

Insulation. First Issue December Kingspan Insulation TECHNICAL SERVICES. Low Energy Low Carbon Buildings

Duct Insulation. Kingspan. Insulation RIGID INSULATION FOR OUTDOOR RECTANGULAR, CIRCULAR AND FLAT OVAL HVAC DUCTWORK. Low Energy Low Carbon Buildings

Engineered Timber Systems AN INTRODUCTION. Low Energy Low Carbon Buildings. CI/SfB (2-) Rj7 - Thirteenth Issue September 2017

K5 External Wall Board

K5 External Wall Board

TW50. I n s u l a t i o n. Low Energy Low Carbon Buildings

Insulation. A4/6 AW2242 Issue 1 Oct Kingspan Insulation

An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor

TR26 LPC/FM / TR27 LPC/FM

Building Fabric vs Building Contents Smoke Toxicity from Room Fires

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

Acoustics: Rain Impact Noise

K8 Cavity Board. Insulation CAVITY WALL INSULATION

K15 Rainscreen Board. I n s u l a t i o n EP E R F O R M A N C. Low Energy - Low Carbon Buildings

Rigid Polyurethane Insulation

K103 Floorboard. Insulation INSULATION FOR FLOORS. Low Energy Low Carbon Buildings. CI/SfB. (13.9) Rn7 M2 Second Issue August 2016

Flooring System. I n s u l a t i o n NEXT GENERATION INSULATION SOLUTION FOR FLOORS. Low Energy Low Carbon Buildings

Same on the outside, different on the inside ODP. Insulation GLOBAL WARMING POTENTIAL AND OZONE DEPLETION POTENTIAL OF DIFFERENT PIR INSULATION

Balcony & Terrace System

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

Solutions. Main Headings Third Issue July Insulation DON T COMPROMISE ON THERMAL PERFORMANCE, FIRE PERFORMANCE AND ENVIRONMENTAL RESPONSIBILITY

TR26 LPC/FM. Insulation INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING. CI/SfB

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

Double Brick Cavity Walls

Brick Veneer Walls. Insulation

TW55. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS. P E R F O R M A N C E Manufactured to BS EN ISO 9002: 1994 Certificate No.

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

Basements. Insulation INSULATION FOR BASEMENTS. Low Energy Low Carbon Buildings. CI/SfB. (13.9) Rn7 M2 Fourth Issue April 2017

K12 Framing Board. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

External Wall System. Insulation NEXT GENERATION INSULATION SOLUTION FOR EXTERNAL MASONRY WALLS. Low Energy Low Carbon Buildings

Insulation for agricultural and industrial buildings

K2 Roofboard. Insulation INSULATION BENEATH FULLY ADHERED SINGLE PLY WATERPROOFING USING SOLVENT BASED ADHESIVES P E R F O R M A N C E

K8 Cavity Board. Insulation PARTIAL FILL CAVITY WALL INSULATION P E R F O R M A N C E BBA BRITISH

Kingspan Insulation at a Glance

Kooltherm FM. Quick Guide. HVAC & Building Services Insulation System

K10 FM Soffit Board. Insulation

CLIMAVER ductwork system. Saves valuable space, reduces installation time and is more cost-effective

floor TF70 Insulation INSULATION FOR SOLID CONCRETE AND SUSPENDED GROUND FLOORS Low Energy Low Carbon Buildings CI/SfB

Quick Guide. Insulation for Refrigerated Applications

Environmental credentials. Energy efficiency and environmental protection with KIMMCO glass mineral wool

Insulbreak. Insulation. thermal break solution

K12 Framing Board. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

roof TR31 Insulation STRUCTURAL 6 mm PLYWOOD COMPOSITE INSULATION BENEATH PARTIALLY BONDED BUILT UP FELT

HVAC SPECIFICATION DETAIL GUIDE. A guide to specifying ROCKWOOL insulations for HVAC applications

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

Car Park Decks. Insulation INSULATION FOR CAR PARK DECKS. Low Energy Low Carbon Buildings. CI/SfB. (27.9) Rn7 M2 Eighth Issue April 2017

Ductslab and Ductwrap

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

June Non - Residential Refurbishment Internal lining walls

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

UL, KUL, WG-KUL, ARK, ARK-1

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

N 500 R/N 700 R. Insulation PROTECTED MEMBRANE HEAVY DUTY CAR PARK DECKS

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels

KoolthermTM FM. Project Specification. HVAC & Building Services Pipe Insulation

Your reference for Recticel PIR insulation.

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE

Sikatherm PIR GT. PIR Thermal Insulation Board. Product Description. Product Data

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW

Dow Building Solutions. Insulating floors with STYROFOAM Solutions: basic principles

Kingspan Insulation Education Sector

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

TR27 LPC/FM. Insulation INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY AND COLD LIQUID APPLIED WATERPROOFING

The thickness of ROCKWOOL insulation

Product Data Sheet. Product: Benchmark Wall Liner System

Kingspan Insulation. Flat Roofing User Guide. Building for the Future. For more information on Kingspan Insulation visit

HP Partial Fill. Robust, long-lasting protection

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Building Regulations for the Conservation of Fuel & Power

Kingspan Insulation. Flat Roofing User Guide. Building for the Future. Technical Advice

2012 Fiscal Impact International Mechanical Code

SECTION HVAC DUCTS AND CASINGS

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

All panels can be supplied in a range of styles, to suit the applications pictured below.

SECTION AIR DUCT CLEANING

Dyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market

HILTI CP 601S Elastomeric Firestop Sealant

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW

HILTI CP 657 Firestop Brick

1.02 Related Sections A. Section Heating, Ventilation and Air Conditioning (HVAC). C. Section Pneumatic and Electric Control HVAC.

Firestone Polyiso Boards

FireMaster FastWrap XL

Insulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP

PRODUCT SELECTION GUIDE. HVAC Insulation

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457)

ACBC Floor Mounted Active Beam

Phenolic foam thermal insulation products for buildings and building services end use applications

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

June Residential Refurbishment Exposed soffit floors

Inverted Roofs. Insulation INSULATION FOR PROTECTED MEMBRANE FLAT ROOFS AND GREEN ROOFS. Low Energy Low Carbon Buildings. CI/SfB

Transcription:

Insulation Third Issue September 2017 The Kingspan AN INTRODUCTION System Low Energy Low Carbon Buildings

Introduction Overview Traditionally, HVAC ductwork is constructed from galvanised sheet steel, which is installed first and then insulated separately as a second operation. The Kingspan KoolDuct System however, is an advanced and innovative pre insulated rectangular HVAC ductwork system, which is installed in a single fix. The Kingspan KoolDuct System eliminates many of the disadvantages associated with galvanised sheet steel, mineral fibre duct board and pre insulated rigid polyisocyanurate (PIR) ductwork systems whilst, at the same time, offering additional advantages to the specifying engineer, the architect, the M&E contractor, the fabricator, the facilities manager, the property developer and the building owner such as: highest levels of thermal efficiency; clean air distribution; speed of installation; and reduced floor space and headroom. Kingspan KoolDuct System Plenum Box Tiger Clip Coupling System Tiger Support & Wire Hanger Assembly Ductwork fabricated from The Kingspan KoolDuct System can reduce air leakage rates to a fraction of those typical of rectangular sheet metal ductwork. This cutting edge System thus offers the triple benefits of cutting energy use, cutting carbon dioxide (CO 2 ) emissions and cutting costs. As a result, The Kingspan KoolDuct System should be considered the ductwork system of choice, where low embodied environmental and low operational environmental impacts are key requirements. Aluminium Grip Coupling System Volume Control Damper 2

4 bolt Coupling System Steel Channel Support & Threaded Rods Fire Damper Access Panel What is The Kingspan KoolDuct System? The Kingspan KoolDuct System comprises premium performance Kingspan KoolDuct panels, fabrication methods, coupling systems and a complete line of accessories to produce pre insulated rectangular ductwork in sections up to 2.95 m long that satisfy the Building Regulations for fire safety, thermal performance and air leakage. Kingspan KoolDuct panels are available in a standard thickness of 22 mm and 30 mm. They comprise a non fibrous rigid thermoset modified resin insulation core faced with silver aluminium foil on one side and either silver or black coated aluminium foil on the other. In addition, there are several coupling systems available to suit different installation and project specification requirements. They include the 4 bolt, aluminium grip and Tiger Clip systems. The design of ductwork, including fittings, fabricated from The Kingspan KoolDuct System follows the same calculation principles and duct sizing methods as are used for ductwork constructed from galvanised sheet steel. Kingspan Insulation offers a complete product line, providing all materials, tools and accessories necessary for the effective fabrication of ductwork from The Kingspan KoolDuct System. Ductwork fabricated from The Kingspan KoolDuct System weighs up to 75% less than ductwork constructed from galvanised sheet steel and then insulated with mineral fibre. The Kingspan KoolDuct System can, therefore, be easily supported by low gauge metal hangers and supports or lightweight wire rope suspension systems such as those manufactured by Gripple Ltd., and at larger centres than with ductwork constructed from galvanised sheet steel. Ductwork from The Kingspan KoolDuct System is only fabricated by specially trained fabricators who have completed The Kingspan KoolDuct System Training Course, and who are registered with Kingspan Insulation Ltd. The required standards of fabrication are detailed in The Kingspan KoolDuct System Fabrication Manual series of publications (see rear cover). Ductwork is installed according to the principles of B&ES DW/144. Pre insulated Circular Duct Turning Vanes Reinforcement System 3

Benefits What s Different about The Kingspan KoolDuct System? Low weight weighs up to 75% less than mineral fibre insulated galvanised sheet this makes it ideal for refurbishment projects, where existing building structures have insufficient load capacities for new service loads. Faster installation speeds low weight ductwork fabricated in sections up to 2.95 m long, single fix installation and no need to install insulation as a second operation, reduces project scheduling periods for insulated ductwork. Space saving typically saves up to 150 200 mm in a single dimension, since the space required to manually install a separate layer of insulation around the ductwork is eliminated this allows ductwork to be installed flush to ceilings, walls and floors, as well as to surfaces within confined enclosures. Installed cost savings reduced labour and materials, including fixings and first level support members, can provide an ideal value engineered ductwork solution without compromising performance over 15% less expensive. Low air leakage rates can be reduced to a fraction of those typical of rectangular sheet metal ductwork can easily achieve: BS EN 1507: 2006 air leakage Class D; BS EN 13403: 2003 Class C; and B&ES (HVCA) DW/144 Class C. Reduced energy usage & running costs low ductwork air leakage can yield significant electrical consumption savings because of reduced heating and cooling loads, and fan energy usage. Class 0 Kingspan KoolDuct panels faced with silver aluminium foil on one side and either silver or black coated aluminium foil on the other, and their rigid thermoset insulation core, are Class 0, as defined by the Building Regulations in England., Euroclass B s1, d0 Kingspan KoolDuct panels faced with silver aluminium foil on one side and silver aluminium foil on the other, are Euroclass B s1, d0, as defined by the European Fire Classification System. UL Listed the only premium performance pre insulated ductwork in the world to be UL Listed as a Class 1 Air Duct, to Standard for Safety UL 181 (Underwriters Laboratories: Factory Made Air Ducts & Air Connectors), when fabricated to a specification clearly defined by UL. Easily modified ductwork configurations can be easily modified and adapted onsite to deal with unexpected changes to the design, which may be required to circumvent unforeseen obstructions and other building design issues. 4

Whole life cost saving up to 25% over 30 years, compared with mineral fibre insulated galvanised sheet steel. Reduced workshop generated waste computer aided fabrication can greatly reduce the volume of waste, compared with manual fabrication. Thin insulation the low thermal conductivity (k value / λ value) of Kingspan KoolDuct panels makes them the most thermally efficient, and hence the thinnest, insulation product commonly used for pre insulated HVAC ductwork. A non fibrous rigid insulation core minimises the risk of loose fibres entering the airstream through the ductwork, since distributed air does not come into contact with an insulation material that produces loose fibres. BS EN ISO 9001 BS EN ISO 14001 BS OHSAS 18001 Manufactured to the highest standards Kingspan KoolDuct panels are manufactured under a management system certified to BS EN ISO 9001: 2008 (Quality management systems. Requirements), BS EN ISO 14001: 2004 (Environmental Management Systems. Requirements) BS OHSAS 18001: 2007 (Health & Safety Management Systems. Requirements) and BES 6001 (Responsible sourcing). Green Guide Summary Rating of 'A' an Ecoprofile, certified by BRE Certification to the BRE Environmental Profiles methodology, has been created for Kingspan KoolDuct panels produced at Kingspan Insulation's Pembridge, UK, manufacturing facility. BRE has assigned the panels a 2008 Green Guide Summary Rating of A. Low embodied environmental impact up to 65% less than that of rock mineral fibre insulated galvanised sheet steel ductwork. Reduced operational CO 2 emissions as a result of low ductwork air leakage, and the subsequent reduction in operational energy usage. Zero ODP & Low GWP the insulation core of Kingspan KoolDuct panels is manufactured with a CFC/HCFC free blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP). BREEAM ductwork fabricated from The Kingspan KoolDuct System can contribute directly, and indirectly, toward the achievement of credits in the building rating system, BREEAM. The relevant credits are Ene1 Reduction of energy use and carbon emissions Mat 1 Life Cycle Impact Mat 3 Responsible sourcing of materials. 5

Applications Application Suitability The Kingspan KoolDuct System is designed for use in building services / HVAC applications. It is suitable for both new build and retrofit projects in the residential, commercial, institutional, light industrial and leisure sectors. Moreover, it is especially suitable for use in non ferrous applications and on high specification projects where non fibrous insulants may be preferred, for instance: the food, beverage and pharmaceutical industries; clean air and hygiene controlled environments; high relative humidity environments; swimming pools; and sterile areas of hospitals and communication / server rooms in data centres. For non standard applications and project specific advice, please contact the Kingspan Insulation HVAC Technical Service Department (see rear cover). Operating Recommendations & Limitations It is recommended that ductwork fabricated from The Kingspan KoolDuct System is used for operation as supply, return, fresh and exhaust air ductwork for heating, ventilation and air conditioning systems within the following limits: Mean Air Velocity (Max.) Design Pressure (Max.)* Temperature Size 25.4 m/s Positive: 1000 Pa Negative: 750 Pa Internal air temperature of 20 C to +80 C during continuous operation. Unlimited (provided that Kingspan KoolDuct System fabrication techniques and procedures are strictly observed). Table 1: Operating Limits for Ductwork Fabricated from The Kingspan KoolDuct System *These are maximum values and vary depending upon both the coupling system and the size of the ductwork. Refer to The Kingspan KoolDuct System Fabrication Manual series of publications for details (see rear cover). NB Mean Air Velocity refers to the design airflow rate related to the cross sectional area of the ductwork. Design Pressure relates to the actual total pressure of the relevant section of ductwork and not the fan static pressure. Total Pressure is a combination of both static and dynamic pressures. Ductwork fabricated from The Kingspan KoolDuct System should not be used in the following applications: conveyance of solids; fire resistant ductwork; kitchen / grease hood exhaust systems; chemical, fume or smoke exhaust systems (please check compatibility with Kingspan); where combustible matter readily collects inside the ductwork; adjacent to any mechanical / electrical sources of extreme heat; outdoor / underground use without mechanical and / or weather protection; where the failure of automatic control equipment may give rise to extreme temperatures; and with equipment of any type that does not include automatic maximum temperature controls. 6

Prestige Projects State of the Art Manufacturing Facility, Ireland Brynmor Jones Library, Hull 7

Contact Details Customer Service For quotations, order placement and details of despatches, please contact the Kingspan Insulation Customer Service Department: UK Tel: +44 (0) 1544 388 601 Fax: +44 (0) 1544 388 888 email: customerservice@kingspaninsulation.co.uk Ireland Tel: +353 (0) 42 979 5000 Fax: +353 (0) 42 975 4299 email: info@kingspaninsulation.ie Literature & Samples Kingspan Insulation produces a comprehensive range of technical literature for designers, specifiers, fabricators, installers, building services managers and facilities managers The literature contains clear user friendly advice on design, design considerations, specification, fabrication, installation, maintenance and product data. Available as individual brochures, Kingspan Insulation technical literature is an essential specification tool. For copies please contact the Kingspan Insulation Marketing Department, or visit the Kingspan Insulation website: UK Tel: +44 (0) 1544 387 384 Fax: +44 (0) 1544 387 484 email: info@kingspaninsulation.co.uk Ireland Tel: +353 (0) 42 979 5000 Fax: +353 (0) 42 975 4299 email: info@kingspaninsulation.ie Technical Advisory Service The Kingspan KoolDuct System is supported by a complementary and comprehensive technical advisory service for designers, specifiers, fabricators, installers, building services managers and facilities managers. Expert guidance is provided to make specification and installation, operation and maintenance of ductwork fabricated from The Kingspan KoolDuct System, as straightforward as possible. Project specific advice and solutions for non standard applications and complex technical issues are also offered. Amongst other services, heat loss / gain, condensation / dew point risk and required insulation thickness can be calculated. Kingspan Insulation also provides a series of technical presentations specifically tailored for designers, specifiers, local authorities and developers. Additionally, site surveys and visits can also be undertaken, if required. UK Tel: +44 (0) 1544 387 382 Fax: +44 (0) 1544 387 482 email: hvactechnical@kingspaninsulation.co.uk Ireland Tel: +353 (0) 42 979 4297 Fax: +353 (0) 42 975 4296 email: technical@kingspaninsulation.ie General Enquiries For all other enquiries: UK Tel: +44 (0) 1544 388 601 Fax: +44 (0) 1544 388 888 email: info@kingspaninsulation.co.uk Ireland Tel: +353 (0) 42 979 5000 Fax: +353 (0) 42 975 4299 email: info@kingspaninsulation.ie Kingspan Insulation Ltd reserves the right to amend product specifications without prior notice. Product thicknesses shown in this document should not be taken as being available ex stock and reference should be made to the current Kingspan Insulation Ltd price list or advice sought directly from Kingspan Insulation Ltd. The information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described herein. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable codes, laws and regulations. For other applications or conditions of use, Kingspan Insulation Ltd offers a Technical Advisory Service, the advice of which should be sought for uses of Kingspan Insulation Ltd products that are not specifically described herein. The fire tests referenced in this literature and the assigned results are not intended to reflect hazards presented by the materials and products described herein under actual fire conditions. Please check that your copy of the literature is current by visiting www.kingspaninsulation.co.uk or www.kingspaninsulation.ie Kingspan Insulation Ltd Pembridge, Leominster, Herefordshire HR6 9LA, UK Castleblayney, County Monaghan, Ireland www.kingspaninsulation.co.uk www.kingspaninsulation.ie Kingspan, KoolDuct and the Lion Device are Registered Trademarks of the Kingspan Group plc in the UK, Ireland and other countries. All rights reserved. Registered in England & Wales, No. 01882722. Registered Office: Pembridge, Leominster, Herefordshire HR6 9LA, UK. VAT GB428602456. Registered in Ireland, No. 152775. Registered Office: Bree Industrial Estate, Castleblayney, Co. Monaghan, Ireland. VAT IE6550175J.