ThermalShell Modular Insulated Pre-Cast Panels

Similar documents
SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

PRODUCT GUIDE SPECIFICATION

Guideline Specifications

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SPECIFICATION GUIDELINE

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

SPECIFICATION GUIDELINE

CS-100 Guide Specifications

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

The following specification refers to the Stepstone, Inc. product known as: Steptreads

***************************************************************************************************************

PRODUCT SPECIFICATIONS

SECTION PRECAST STRUCTURAL PRETENSIONED CONCRETE

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

Corium Brick Rainscreen System Specifications

G. Shop drawing of wall with all dimensions, details, and finishes. Drawings must include post foundations.

Product Guide Specification

ENKASONIC FLOOR UNDERLAYMENT 9110

SECTION GLASS-FIBER-REINFORCED PRECAST CONCRETE

Proudly Made in the U.S.A.

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

SECTION EXTERIOR GRILLS AND SCREENS

RAY-CORE Structural Insulated Roof and Wall Panels

Narrow Modular Pavers (NMP) for Mortar-Set Concrete Tiling Installations

Ultra-High Performance Wall System Glass Fiber Reinforced Concrete

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

by Rollfab Metal Products

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

Floor Insulation Underlayment Section Sound Control Matting

MANUFACTURER S SPECIFICATION

Narrow Modular Pavers (NMP) for Sand-Set Installations

SECTION STEEL DECKING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

for Mortar-Set Concrete Tiling Installations

Learning Objectives. A Brief History

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.


MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

SECTION ARCHITECTURAL CAST STONE

BEARING METAL STUD FRAMING

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

SECTION MANUFACTURED STONE VENEER. A. Section Includes: 1. Manufactured stone veneer masonry, accessories, and related materials.

SECTION BRICK MASONRY ASSEMBLIES

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION DECORATIVE METAL FENCES AND GATES

SECTION EPOXY FLOORING SYSTEMS

Gold Bond BRAND Gypsum Sheathing

SECTION CHAIN LINK FENCES AND GATES

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SL150 Guide Specification

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

CAST IN PLACE TACTILE / DETECTABLE WARNING SURFACE TILES

SECTION EXPANSION CONTROL

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Design Reference Sample: Sample of approved precast structural concrete color, finish, and texture, preapproved by Architect.

Attachment A-Flagpole(s) Specifications

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) REV: 4/11

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Stonecraft Industies 8300 County Road Holmesville, OH

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

FRP Floor Panels Standard Specification

Thermal Systems KWC Ltd. Telephone: (403) Avenue N.E. Facsimile: (403)

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

SECTION EPOXY TERRAZZO

SECTION MANUFACTURED MASONRY VENEER


SPECIFICATION GUIDE. thin glazed brick

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

INSULATED CONCRETE MASONRY UNITS Section 04220

SECTION METAL BUILDING SYSTEMS

SECTION SITE CONCRETE

SECTION TURBINE VENTILATORS

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

SECTION PRECAST STRUCTURAL PRETENSIONED CONCRETE

A-Series Aluminum Gantry Crane

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

SECTION RESILIENT SHEET FLOORING

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Magnum Board Section Digicon Information Inc. Page 1

Product Guide Specification

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

SECTION GUTTERS AND DOWNSPOUTS

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

A. Drawings and general provisions of the Contract, including General Conditions Specification Sections, apply to this section.

SIERRA MODEL 12 X 24 SPECIFICATIONS

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

Transcription:

412 N. California St. Building #2 Sycamore IL, 60178 Phone: 815.899.0224 Fax: 815.899.0226 E-mail: info@thermalshell.com Web: www.thermalshell.com ThermalShell Modular Insulated Pre-Cast Panels Construction Specification Institute Section 034500 3 Part Guide for Specification PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the performance criteria, materials, production, and erection of insulated architectural precast concrete for the entire project. The work performed under this section includes all labor, material, equipment, related services, and supervision required for the manufacture and erection of the insulated architectural precast concrete work shown on the contract documents. B. This Section includes the following: 1. Insulated, architectural precast concrete cladding units C. Related Sections include the following: 1. Division 5, Section Structural Steel 2. Division 7, Section Sheet Metal Flashing and Trim 3. Division 7, Section Joint Sealants 1.3 DEFINITIONS A. Design Reference Sample: Sample of approved architectural precast concrete color, finish and texture, pre-approved by Architect. 034500-1

1.4 PERFORMANCE REQUIREMENTS A. Provide architectural precast concrete units and connections capable of withstanding the following design loads within limits and under conditions indicated: 1.5 SUBMITTALS 1. Dead Loads: 35 lbs/square foot 2. Live Loads: 15 lbs/square foot 3. Uplift: 5 lbs/square foot 4. Wind Loads: 80 Mph 5. Seismic Loads: <Insert Applicable Loads> 6. Project Specific Loads: <Insert Applicable Loads> 7. Design framing system and connections to maintain clearances at openings, to allow for fabrication and construction tolerances, to accommodate live load deflection, shrinkage and creep of primary building structure, and other building movements as follows for upward and downward movement of one half (½) inch. B. Product Data: Submit producer s or manufacturers specifications and installation instructions for following products. C. Shop Drawings: Detail fabrication of architectural insulated precast concrete units. Indicate member locations, plans, elevations, dimensions, shapes and cross sections. Indicate aesthetic intent including joints, reveals, and extent and location of each surface finish. Indicate details at building corners. 1. Design Modifications: If design modifications are necessary to meet the performance requirements and field conditions, submit design calculations and drawings. Do not adversely affect the appearance, durability or strength of units when modifying details or materials and maintain the general design concept. D. Samples: Design reference materials for initial verification of design intent, approximately 12 by 12 by 2 inches (300 by 300 by 50 mm), representative of finishes, color, and textures of exposed surfaces of architectural precast concrete units. E. Qualification Data: For firms and persons specified in Quality Assurance article to demonstrate their capabilities and experience. Include list of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified. 034500-2

F. Material Test Reports: From a qualified testing agency indicating and interpreting test results of the following for compliance with requirements indicated: 1. Concrete materials 2. Reinforcing materials 3. Admixtures 4. Insulation 5. Light gauge steel 1.6 QUALITY ASSURANCE A. Erector Qualification: An Erector with a minimum of 2 years of experience who has completed architectural precast concrete work similar in material, design, and extent to that indicated for this project and whose work has resulted in construction with record of successful in-service performance and approval by ThermalShell manufacturer. 1.7 PRODUCT DELIVERY, STORAGE AND HANDLING A. Store units with adequate support, bracing, and protection units to prevent contact with soil, staining, and to prevent cracks, distortion, warping or other physical damage. B. Handle and transport units in a position consistent with their shape and design in order to avoid excessive stresses with would cause cracking or damage. Lift and support units only at designated points shown on the Shop Drawings. C. Deliver all insulated precast units to the project site in such quantities and at such times to assure compliance with the agreed project schedule and proper setting sequence so as to limit unloading units temporarily on the ground. D. Store packaging materials for reuse on the project site in a manner that will prevent damage, staining, and dispersion by wind. Packaging materials not for reuse should be disposed of in an appropriate waste or recycling container. 1.8 PRODUCT WARRENTY A. Manufacturer s warranty: Submit, for Owner s acceptance, ThermalShell s standard warranty document executed by authorized company official. ThermalShell s warranty is in addition to and not intended to limit other rights Owner many have under the Contract Conditions. 034500-3

PART 2 PRODUCTS 2.1 MANUFACTURERS A. Subject to compliance with requirements indicated herein, provide products of the following manufacturers: 1. ThermalShell Technologies, Inc. 421 N. California St., Building #2 Sycamore, IL Phone: (815) 899 0224 Fax: (815) 899 0226 E-mail: info@thermalshell.com URL: www.thermalshell.com 2.2 MODULAR SIZES AND WEIGHTS A. Concrete Wall Panels: 1. Width: 6-0 2. Height: [Spec to Requirements, Maximum 48-0 ] 3. Thickness: 8 (R-30) 4. Weight: 22.5 lbs. per square foot B. Steel Wall and Roof Panels 2.3 MATERIALS 1. Width: 6-0 2. Height: [Spec to Requirements, Maximum 48-0 ] 3. Thickness: 6 (R-26) 4. Weight: 2.5 lbs. per square foot A. Concrete: 1. Refractory Calcium Aluminite Cement 2. 6% Air Entrainment 3. Maximum Water-Cementitious Materials Ratio: 0.4 4. Proprietary Setting Accelerant Admixture 5. Additional Nitrates to Protect Reinforcement from corrosion 6. ASTM C1116 multifilament nylon reinforcement fibers 7. Release Strength (minimum): 3000 psi 8. Final Compressive Strength (28 day): 5500 psi 9. Use of calcium chloride of chloride ions is not permitted. 034500-4

B. Concrete Reinforcement: 1. ASTM A 497 10 gauge wire mesh in flat sheets, placed no closer than ¾ from surface of concrete 2. ASTM A 615/A 615M #5 rebar fabricated and place as dictated by shop drawings C. Polyurethane: Insulation value 6.5 R per inch, Minimum 92% closed cell count, Maximum 0.03 lb/sq.ft. Water Absorption. 1. Use UL-94 rated HF-1 Polyurethane products 2. [ Use ASTM E-84, Flame Spread: 50, Smoke Developed 350 rated Polyurethane products ] D. Steel: 26 gauge thick, Grade E Full Hard 100,000 psi tensile strength, Form rolled to R panel configuration with 1 ¼ standing ribs at 12 on center. 2.4 FINISHES 1. Steel Paint: Siliconized Polyester (1 mil) with the following properties: ASTM 3363 rated F-2H hardness; ASTM 523 60 degree gloss; ASTM 2794 impact resistance; ASTM B117 rate 2000 hours of salt spary; ASTM D4585 rate 2200 hours of condensing; ASTM D2247 rated 2000 hours humidity; ASTM D870 rated 1000 hours water immersion; ASTM G87 passed 33 cycles acid rain; ASTM D968 rate 40 liters/mil abrasion resistance. A. Standard interior surface: 26 gauge steel paneling, roll formed to R panel configuration and tolerances. Smooth Texture. Painted glossy white. [Additional colors available upon request and subject to availability] [For Steel Wall Panels, Remove Following Paragraph If Unnecessary] B. Standard exterior steel surface: 26 gauge steel paneling, roll formed to R panel configuration and tolerances. Smooth Texture. Painted glossy white. [Additional colors available upon request and subject to availability] C. Available exterior concrete surfaces: [Choose Finishes appropriate for Project] 1. Smooth Finish: Provide surfaces free of excessive air voids, sand streaks, and honeycombs. 2. Standard Pattern Cast: Use standard plastic concrete molds available from Fitzgerald Formliners or similar manufacturers. [Provide pattern number from manufacturer s catalogue.] 3. Custom Pattern Cast: Subject to availability of suitable mold, use provided artwork to create a non-standard pattern mold to cast into the concrete surface. 034500-5

4. Brick Tile: Use Thin or Half Brick units with appropriate forms and accessories available from Fitzgerald Formlines or similar manufacturer. [Provide brick sizes and colors from manufacturer s catalogue.] 5. Acid Washed/Exposed Aggregate: Use chemical retarding agents applied to concrete forms and washing/brushing procedures to expose aggregate and surrounding matrix surfaces. 6. No concrete color: Provide surfaces free of pigmentation, debris or excessive mixture color variation. 7. Single concrete color: Use appropriate coloring and admixtures to permanently pigment the concrete without excessive color variantion. 8. Single color concrete painting: Finish panels with decorative exterior concrete paint available from Tamms or similar manufacturer. [Provide paint product number and color from manufacturer s catalogue]. Manufacturer is not responsible to any touch up painting. 9. Multiple color concrete painting: Finish panels with decorative exterior concrete paints available from Tamms or similar manufacturer. [Provide paint product numbers and colors from manufacturer s catalogue]. Manufacturer is not responsible to any touch up painting. PART 3 EXECUTION END OF SECTION 034500-6