VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

Similar documents
VELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL VCE/VCM/VCS VENTING CURB MOUNT SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL VS and VSE NO LEAK VENTILATING SKYLIGHT SECTION UNIT SKYLIGHTS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

Fixed Curb Mount (FCM) Unit Skylight - Guide Specification

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)

WESTECK WINDOWS and DOORS

Alply CLASSIC WALL Architectural Insulated Panel Wall System

CS-100 Guide Specifications

SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations

TMS 114 XT TECHNICAL MANUAL

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

TMS 152 / 152T / 152XT TECHNICAL MANUAL

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

Corium Brick Rainscreen System Specifications

DIVISION 8 OPENINGS SECTION ALUMINUM WINDOWS

SECTION SPECIAL FUNCTION GLAZING

Commercial Dynamic Dome Unit Skylight - Guide Specification

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS

S Page 2 of 14 E0A0 2

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

SECTION METAL ROOF PANELS

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SECTION EXTERIOR GRILLS AND SCREENS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION ALUMINUM STORM WINDOWS

AUGUST, 2017 IR 500/501 Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

Repair Maintenance Hangar Phase II August 2010

Why test a system that has already been tested? Typical Manufacturers information for window to wall interface and basis for reported test results.

NOTE TO SPECIFIER: This section is based on the products of Solar Innovations, Inc., which is located at:

SECTION SECTIONAL OVERHEAD DOORS

Model 4000-IM Single Hung H-C x 2300 (56 x 91 )

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

ATI Evaluation Service A Division of Architectural Testing Certification Services

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

NOTE TO SPECIFIER: This section is based on the products of Solar Innovations, Inc., which is located at:

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

CENTRIA FORMABOND II Metal Composite Wall System

MARCH, 2017 Trifab 451UT Framing 1 EC ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Guide Specs

Veka Evolutions Commercial Window Program

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

Model 8000 Double Hung H-C x 2311 (56 x 91 )

Series Heavy Commercial Projected Window

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SL150 Guide Specification

A. Section includes sliding aluminum-framed glass doors for exterior locations.

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

American Architectural Manufacturers Association VOLUME 1 - WINDOWS AND DOORS

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

SECTION TURBINE VENTILATORS

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

E-Wall System 5800, 5800-I

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

NanaWall Matching Windows and Doors Table of Contents

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

Structural Performance Tests of VHB Structural Glazing Tapes

SunWave Prismatic Skylights

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

Series 510-I Thermal Heavy Commercial Projected Window

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Guide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL

Guideline Specifications

VINYL SINGLE HUNG WINDOW

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

SECTION HVAC GRAVITY VENTILATORS

A. Access doors and frames are part of an access door and frame allowance.

SL70 The Monumental Thermally Broken Aluminum Framed Folding System

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

by Rollfab Metal Products

Transcription:

SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX QPF selfflashed fixed skylight. B. Unit skylight mounted directly to roof decking. C. Skylight and flashing provided as one complete assembly. 1.02 REFERENCE STANDARDS A. ASTM E 283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specific Pressure Differences Across the Specimen. B. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference. C. ASTM E 331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference. D. ASTM E 1886 Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials. E. ASTM E 1996 Standard Specifications for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes. F. National Fenestration Rating Council, NFRC 100, Procedure for Determining Fenestration Product U-factors. G. National Fenestration Rating Council, NFRC 200, Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence. H. National Fenestration Rating Council, NFRC 300, Test Method for Determining the Solar Optical Properties of Glazing Materials and Systems.

2 I. Occupational Safety & Health Administration, OSHA Standards 29 CFR 1910.23, Guarding Floor Openings and Holes. 1.03 SYSTEM DESCRIPTION A. Skylight: Fixed self-flashed skylight consisting of the following main integrated components - an interior condensation drainage gasket, an insulating glass unit, exterior structural sealant, roll-formed aluminum frame counter flashing, ASA corner keys, welded aluminum base flashing, and wood frame. B. Configuration: Fixed unit, deck mounted C. Condensation Control: Integral internal condensation collection system and drainage slots. D. Accessories available but sold separately: a. Manual blackout blinds, manual venetian blinds, and manual roller blinds. b. Solar powered blackout blinds, solar powered roller blinds. E. Manual controls are available but sold separately. a. Six ten feet manual telescopic rod. b. Six ten feet motorized telescopic rod. 1.04 PERFORMANCE REQUIREMENTS A. The QPF self flashed fixed skylight is independently tested in accordance with listed standards for compliance with the unit skylight provisions of the 2003, 2006 and 2009 IBC, IECC, and IRC as follows: a. AAMA/WDMA/CSA 101/I.S.2/A440-05 NAFS-05 and AAMA/WDMA/CSA 101/I.S.2/A440-08 NAFS-08. Performance Grades must be greater than or equal to: i. Downward design pressure = 210 psf ii. Uplift design pressure = 55 psf

b. AAMA/WDMA/CSA 101/I.S.2/A440-02 (NAFS 02) Rated pressures must be greater than or equal to: i. Downward design pressure = 150 psf ii. Uplift Design Pressure = 70 psf VELUX America Inc. 3 B. Air leakage: Maximum of 0.9 l/s/m² (0.17 CFM/ft²) of total unit area, measured at a differential pressure of 75 Pa (1.57 psf) in accordance with ASTM E 283, per the NAFS standards in (A). C. Water infiltration: No water penetration noted as measured in accordance with ASTM E 331 with a test pressure differential of 720 Pa (15.0 psf). Exceeds requirements of NAFS standards in (A). D. Thermal Performance: U-factor = 0.44 Btu/hr*ft 2 *F or less, SHGC = 0.24 or less and [VT = 0.52 or greater (clear)] [or VT = 0.39 (white)]. Tested and certified in accordance with NFRC 100 and 200 procedures. 2010 ENERGY STAR qualified all U.S. zones. E. QPF skylights with impact glazing (06): Tested and certified in accordance with ASTM E 1886 and ASTM E 1996, Cycle Pressure +50/-50, Missile Level C, Wind Zone 3. F. Limit member deflection to flexure limit of glass with full recovery of glazing materials. G. System accommodates, without damage to components or deterioration of seals, movement between flashing and frame. 1.05 SUBMITTALS A. Product Data: Manufacturer s installation details and product data sheets include: a. Preparation details and installation instructions b. Product Data sheets with storage and handling information c. Architectural roof sectional drawings can be found at www.veluxusa.com. d. Code compliance information can be found within these specifications, or by contacting VELUX at 800-888-3589, or by visiting www.veluxusa.com.

4 B. Architectural/Cross Sectional Drawings a. Mounting details b. Frame sizes c. Flashing details C. Shop Drawings a. Indicate material types, gauge, finishes, and installation details D. Maintenance Data: For unit skylights (sunscreening accessories) to be included in maintenance manuals. E. Warranty: Sample of warranty or special warranty 1.06 QUALITY ASSURANCE A. Manufacturer Qualifications: a. Skylight manufacturer shall have a minimum of ten years experience in design and fabrication of deck mount glass skylights. b. Skylights shall be manufactured to the highest standards of quality and craftsmanship in ISO 9001 and ISO 14001-certified facilities. B. Source Limitations: Obtain unit skylights and accessories from a single source and from a single manufacturer. a. Electrical Components, Devices, and Accessories: Listed and labeled by a qualified testing agency as defined in NFPA 70, and marked for intended location and application. b. Unit Skylight Standard: Comply with AAMA/WDMA 101/I.S.2./NAFS, North American Fenestration Standard Voluntary Performance specifications for Windows, Skylights and Glass Doors, and all later editions, for minimum standards of performance, materials, components, accessories, and fabrication. Comply with more stringent requirements if indicated. c. Provide third-party certified unit skylights with attached labels. d. Thermal Performance rated per applicable NFRC procedures. i. Provide NFRC-certified unit skylight ratings on an attached label. ii. Qualify under ENERGY STAR criteria in all 50 states carry a verifying label.

1.07 COORDINATION VELUX America Inc. 5 e. Manufactured to the highest standards of quality and craftsmanship in accordance with VELUX Manufacturing Standards. A. Coordinate unit skylight installation requirements with roofing system. B. Pre-installation conference: conduct conference at (project site). 1.08 WARRANTY A. Standard VELUX product warranty, as specified in VELUX Warranty, publication XUS 20194. 1.09 DELIVERY, HANDLING, STORAGE A. Deliver products in manufacturer's original containers dry and undamaged, with seals and labels intact. B. Store and protect products in accordance with manufacturer's recommendations. PART 2 PRODUCTS 2.01 MANUFACTURER A. Acceptable Manufacturer: VELUX America Inc., P.O. Box 5001, Greenwood, SC 29648; Toll Free Tel: 800-888-3589; Fax: 800-388-1329; Web: www.veluxusa.com B. Substitutions: Not permitted 2.02 MATERIALS A. Maintenance-free Exterior Aluminum Frame and Covers: Roll-formed 15 gauge, 1.5-mm (0.06 ) thick, prefinished neutral gray, production engineered and fabricated to fit. B. Field Fasteners: (flashing to roof decking) 2 and 1-1/4 ring shank nails coated with double hot-dipped zinc provided with skylight.

6 C. Dual sealed Glazing a. Dual sealed thermal pane with warm edge technology, 95% argon gas fill, and with three layers of LoE³ silver that increases visible light over standard low-e coatings while lowering the solar heat gain. The following glazing options are available: i. 04 Tempered LoE³ pane over a laminated heat strengthened interior pane with 0.030 interlayer. ii. iii. 05 Tempered LoE³ pane over tempered interior pane. 06 Tempered LoE³ pane over a laminated heat strengthened interior pane with 0.090 interlayer. D. Manual Operator Accessories a. Manual control rods and extension poles available for manual operated sunscreening accessories. E. Weather stripping: Factory applied neoprene and thermoplastic elastomeric weather stripping around entire frame, profiled to effect weather seal. 2.03 Flashing options A. Base flashing and skylight assembled as one complete unit. 2.04 FABRICATION A. Provide internal drainage of glazing spaces with exterior through gasketing to remove condensation. B. All units are factory glazed with structural silicone-based primary seal. 2.05 FINISHES A. Maintenance-free roll-formed aluminum outer frame cover with neutral gray Kynar 500 polyvinylidene fluoride resin finish. B. Maintenance-free flashing: Extruded aluminum with welded corners, neutral gray, baked on polyester polyamide primer and finish coats. C. Factory applied white pre-finish interior wood frame.

7 PART 3 EXECUTION 3.01 EXAMINATION A. Verify rough opening dimensions, squareness, roof pitch, and proper orientation of skylight. 3.02 INSTALLATION A. Install skylight in accordance with manufacturer s installation instructions and local code requirements. B. Align skylight so it is free of warp or twist, maintaining dimensional tolerances. C. Anchor skylight to decking with ring shank nails furnished by manufacturer. D. Provide thermal isolation when components penetrate or disrupt building insulation. Pack fibrous insulation in rough opening to maintain continuity of thermal barriers. E. Coordinate attachment and seal of perimeter air and vapor barrier material. F. Install sunscreening products and electrical or manual controls. 3.03 Cleaning A. Clean exposed skylight according to manufacturer s written instructions. Touch up damage to coatings and finishes. B. Remove excess sealants, dirt, and other substances. C. During the construction process, protect the skylight surfaces from contact with contaminates. 3.04 Field Quality Control A. Install skylight and accessories in accordance with manufacturer s installation instructions.