E xpanding F ireproof Coat ings

Similar documents
Waterbased Range Protective coating solutions that cover your needs

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

Coatings - Linings - Fireproofing. Thermo-Lag E100. Epoxy Intumescent Fireproofing

Coatings - Linings - Fireproofing. Thermo-Lag E100. Epoxy Intumescent Fireproofing

Thermo-Lag E100. Epoxy Intumescent Fireproofing

International Fireproof Technology Inc.

Property Test/Standard Description

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS FOR JOINTS AND PENETRATIONS

Intumescent Fire Protection Solutions for Structural Steel

PRODUCT DATA SHEET Sika Unitherm Platinum

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

DULUX WEATHERGUARD FINE TEXTURED

Property Test/Standard Description

TECHNICAL DATA SHEET

Industrial Coatings. Protect your application by choosing the proper coating.

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

White, a range of ready-mixed colours, and colours from the Dulux Colour System

NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings

THERMO SOLUTION. Ceramic Thermal Insulating Coating

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

Property Test/Standard Description

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Coating Specifications

Permaflex: versatile systems for industrial application.

Official Journal of the European Union DIRECTIVE 2004/42/CE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL. of 21 April 2004

Sectional garage doors. A product of ALPHA Deuren International BV

Two component solvent-free epoxy system for creation of self-levelling floors. Gloss <4% <70% IR4

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS

Maximum Rust Protection!

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Waterborne Epoxy Curatives. High performance. Low emissions. Cost-effective.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Acronal PRO & Joncryl Water based Resins for Metal Protection

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

RECOMMENDED APPLICATION INSTRUCTIONS FIRE RETARDANT COATINGS FOR CABLES AND FIRE RESISTANT BARRIERS FOR SERVICE PENETRATION SEALS

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

Strength in unity. Quelle/Publication: European Coatings Journal. Seite/Page:

Property Test/Standard Description

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

European Coatings Handbook

Date of issue: 5 October 2017 Page: 1/6

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Property Test/Standard Description

Solution Vinyl Resin

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

2013 COMMERCIAL PRODUCTS

Property Test/Standard Description

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

More than just a Zinc Phosphate. Zinc Phosphate ZP 10

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

TempSpray. Outlet Heated material. Inlet Cold material. Function Benefits Product details

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

FIRE-RETARDANT TREATMENTS FOR WOOD 1

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

EZWall TM REAL BRICK CLADDING SYSTEM. E uroform Products Ltd. Solutions for the building industry

Property Test/Standard Description

Magnesium Oxide Wallboard

TT-P-1757B Type I, Class C, Aerosol Zinc Chromate Primer. A one component, alkyd base, corrosion inhibiting zinc chromate primer.

Rust Bullet Home and Farm FAQ s

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems LIMBOROUTE LW48 TECHNICAL INFORMATION

Technical Datasheet E

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: CARBOLINE COMPANY

Property Test/Standard Description

PRIMERS & SURFACE PREPARATION GUIDE

SPECIALIST PRODUCTS. Leading edge solutions for specialist commercial applications. Innovative technology. Ultimate performance

Architectural Coatings & Finishes (ACF) Acrylic Finishes Elastomeric Finishes Acrylic Coatings Elastomeric Coatings ACF Assemblies

FIRE RETARDANT COATING

118 RAKENNUSTEKNIIKKA Olli Ilveskoski rev FIRE SAFETY

Waterborne Wood Furniture Coatings Time is NOW!

Technical Information Sheet

Charring rate of intumescent fire protective coated Norway spruce (Picea abies L.)

METAL & MACHINERY PAINT POLYURETHANE FLOOR PAINT SKIP & CONTAINER PAINT

PRODUCT SELECTION GUIDE

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Product Data Sheet AkzoNobel Powder Coatings Interpon APP 120 (EL140G)

GREENHOUSE ENGINEERING PREFABRICATED HOUSES

SAVIER - 6 (FIRE RETARDENT PAINTS, PRIMERS & FLAME PROOF CLOTHS)

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Ask for FSC certified products. Ask for PEFC certified products.

Highlights of DANA Insulated Sandwich Panels

For purchasing information visit: Sikkens Cetol Novatech

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Property Test/Standard Description

A clear vision of what you imagined

SCHOTT UK Ltd Sales Office Drummond Road Stafford ST16 3EL Phone: Fax:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 09 - FINISHES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

^(ValidationDate) AE - BH - DZ - EG - KW - LY - MA - OM - QA - SA - TR Jotashield Tex Ultra

Transcription:

E xpanding F ireproof Coat ings INTERNACIONAL

FIRESTOP Expanding Fireproof Coatings Superior solution for re protection of building structures FIRESTOP coatings are expanding (intumescent) coatings designed for e ective re protection of steel and wooden building structures. These modern thin- lm coatings are made by innovative technology with function to stop re spreading and they act within system of passive re protection. In case of re, specially formulated FIRESTOP coatings react and form foam insulation that protects steel and wooden structures up to 90 min. In this way they provide necessary time for re ghters and rescue services for evacuation of people and minimize human and material damage. Bene ts of the FIRESTOP coatings: top quality: the uniform expansion of foam; good stability of formed insulator high ecological standards: water-based products, not containing halogens and synthetic solvents materials and faster work fast and easy application: directly from the package without further dilution; the interlayer drying - few hours; easy repairment of possible damage durability: long exploitation life technical support to customers by the engineering team and training possibilities for contractors Exceptional performance of FIRESTOP coatings are tested and certi ed by the highest relevant national and international institutes and prov onditions. FIRESTOP coatings have been applied in more than 300 buildin ch Our company provides training of contractors, consulting of designers and architects, as well as technical support and expertise of our engineering team in solving spe ustomer requirements.

goods. Acting within a passive re protection system, FIRESTOP coatings isolate and reduce the temperature ect their re characteristics - re resistance. FIRESTOP coatings - The mechanism of action Intumescent coatings are combination of di erent compounds, which (as a result of increased temperature in re) act together and form carbon foam. Foam reaches a thickness of 10 to 100 times greater than the initially applied coating and protect and insulate the construction with its low thermal conductivity. Components of the coating react at relatively low temperatures (150-180 C) - e ected by the flame, and release gases (at temperature around 250 C) which cause expansion - swelling. The newly formed foam is a good insulator that provides protection of treated materials for certain period of time. Picture 1 Picture 2 Picture 3 Picture 4 Display of FIRESTOP coatings expansion and formation of carbon foam The advantage of FIRESTOP coating over competing products is reflected in the proper expansion and excellent stability of the foam insulator that provides long lasting and e cient re protection. FIRESTOP Expanding Fireproof Coatings

FIRESTOP steel Fire protection of steel and metal elements Due to its functionality, durability, cost of implementation and an unlimited choice of architectural solutions in building design, steel is one of the most commonly used materials in modern construction. Steel structures are present in all areas of construction, from industrial buildings, factories and halls, to sports and stability and bearing capacity. This can result collapse of buildings and disastrous social and economic consequences. FIRESTOP system for the protection of steel consists of: Base anti-corrosive coating / primer Intumescent coating FIRESTOP steel Decorative top coating. Decorative top coating Intumescent coating FIRESTOP steel Base anti-corrosive coating Blasted steel Sa 2 1/2 This system, based on FIRESTOP steel coating is an ideal solution for the e ective re protection of steel structures. In combination with the appropriate anti-corrosive primer and decorative top coating, system provides protection of steel against corrosion and weathering, as well as the visual appeal of the treated elements. Required thickness or consumption of intumescent coating FIRESTOP steel depends on the size and geometry of protected steel elements (section factor), number of sides exposed to re, desire re protection period and function of the structures.

Characteristics of FIRESTOP steel coating: exceptional performance quick and easy application environmentally-friendly product consumption less than 20% compared to competitive products Thanks to these characteristics FIRESTOP steel won the leading position in the Application of FIRESTOP steel on site FIRESTOP Expanding Fireproof Coatings

Fire protection of wood and wooden structures Wood is natural and traditionally very popular material in construction. Untreated wood is flammable material. However, wood and wooden structures can be successfully protected with FIRESTOP intumescent coatings and thus pass into the category of materials that are not flammable. FIRESTOP wood FIRESTOP white system for wood protection consists of: Base coat - primer Intumescent coating FIRESTOP wood Decorative top coating This system, based on FIRESTOP wood coating provides e ective re protection of wood and wooden structures. Selecting the proper primer and decorative nish paint, this system provides protection of wood from weathering and visual attractiveness of the treated elements. FIRESTOP wood - T FIRESTOP transparent system for re protection of wood in the interior consists of: Base coat - primer Transparent intumescent coating FIRESTOP wood - T Decorative clear coat Using FIRESTOP wood - T coating wood structures remain visible, i.e. coated surfaces remain transparent appearance which has a signi cant aesthetic e ect in interior design.

THE RANGE OF FIRESTOP INTUMESCENT COATINGS FIRESTOP steel FIRESTOP wood of steel of wood Provides protection from cellulosic Provides protection from cellulosic Provides protection from cellulosic White matte coating, water-based Consumption 1.9 kg/m2 DFT Application: compressor gun, airless spray, brush, roller White matte coating, water-based Consumption 0.45-2.34 kg/m2 for 250-1300 µm DFT Application: compressor gun, airless spray, brush, roller Transparent coating, water-based Consumption: 0.875-1.75 kg/m2 Application: compressor gun, airless spray, brush, roller 90 min FIRESTOP wood-t Transparent one-component coating 90 min min Base coatings Top coatings PRIMTEC steel Alkyd quick drying anti-corrosive zinc phosphate primer in FIRESTOP system for steel protection. Produced in gray and red. Depending on the selected FIRESTOP system, as well as the type and function of building construction, top coating is selected. PRIMTEC wood Water based primer in FIRESTOP system for wood protection. It is diluted with water in a ratio of 1:4-1:6. coatings from moisture and weather conditions. ŽIŽOL and ŽIŽOL NEO PROTECT E cient water-soluble solvent for protection of timber and wooden structures from the harmful insects and woodworm. Additional program PRIMTEC thinner Synthetic thinner, intended for dilution of base anticorrosive coating PRIMTEC steel. MOTOFUS Nitro thinner Synthetic thinner, designed for diluting and dissolving nitrocellulose paints and varnishes. PLAY OX Universal concentrated degreaser for cleaning and degreasing metal, plastic, wood and combined surfaces and parts. Paint remover/striper For removal of synthetic paints from wood and metal surfaces, as well as from walls, without surface damaging. Paint remover WB REMOVER Universal solvent for removing acrylic, polyvinyl acetate astic, surrounding areas. ANTIKOROZION Agent for removing and neutralizing corrosion on iron and steel elements. cleaning and degreasing of metal surfaces and parts. coatings application. FIRESTOP TERMABOND Heat resistant adhesive for mineral wool and insulatingfoil. It is used in the construction industry in the production of insulating sheathing.

INTERNACIONAL