BUILDING CODE COMMISSION

Similar documents
BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

BUILDING CODE COMMISSION

BUILDING CODE VARIANCE

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL

PRESCRIPTIVE COMPLIANCE METHOD

Module 8: Ontario Building Code Fire and Spatial Separations

Building Codes and Ordinances ARC 227

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

Work Group Item Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches (914 mm).

2009 IBC Section 1024 Approved Luminous Egress Path Markings

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

2015 IBC Accessible Means of Egress

Reference Guide: Mid-Rise Wood Construction in the Ontario Building Code Report by Morrison Hershfield (January 2015)

BUILDING PERMIT GUIDELINES - RESIDENTIAL

FBC 5 th Edition. General. Update to the Florida Building and Residential Codes Updates to the Florida Building and Residential Codes

BUILDING CODE COMMISSION

Basement Renovation Guide For Residential Dwellings

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

E2-09/ (IFC [B] )

Building Permits A Guide for Homeowners

CITY OF TORONTO. BY-LAW No (OMB)

2015 IBC Exit Systems

COMMUNITY RISK REDUCTION BUREAU MANUAL CODE REQUREMENTS TEMPORARY TENTS AND MEMBRANE STRUCTURES EFFECTIVE: APRIL 1, 2016 AUTHORIZED: R.

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Condominium Project Profile and General Review Form

Chicken Farmers of Ontario Modular Loading Regulation No

City of Tacoma Planning and Development Services

Table of Contents. List of Drawings

IWF Safety Guidelines

2012 IBC Exit Systems

Building Permit Application Instructions INFORMATION REQUIRED FOR ISSUANCE OF A BUILDING PERMIT

ICC CODE CORNER 2012 IFC Code & Commentary

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

CITY OF TORONTO. BY-LAW No

PRESCRIPTIVE COMPLIANCE METHOD

WHO IS THIS COURSE FOR?

Important Notice To Building Permit Applicants and Designers

Applying the Building Code During Design

TORONTO MUNICIPAL CODE CHAPTER 492, GREEN ROOFS. Chapter 492 GREEN ROOFS. ARTICLE I General. ARTICLE II Requirement for Green Roofs

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

Building Code 8 th Edition

QUEEN ALEXANDRA COMMUNITY CENTRE

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

Industrial Establishments Regulation Amendment Proposal

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Village of Glencoe 675 Village Court, Glencoe, Illinois

Comparison of the life safety elements of the 1997 UBC and the IBC 2000.

62 POTOMAC STREET WEST ROXBURY, MA 02132

SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

780 CMR CHAPTER 34 EXISTING BUILDINGS STRUCTURES

EGRESS CHAPTER ,500 3 Over 2,500 4 OCCUPANT LOAD REQUIRED MEANS OF EGRESS

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

FOR SALE STATE-OF-THE-ART MANUFACTURING/WAREHOUSE STATE-OF-THE-ART MANUFACTURING/WAREHOUSE. 950 South Service Rd. Stoney Creek, ON

EXIT ACCESS RAMP. An interior ramp that is not a required interior exit ramp.

2006 NC Rehabilitation Code

HOT SPRINGS FIRE DEPARTMENT EVALUATION OF DOWNTOWN LEGACY STRUCTURES Savoy Hotel Thompson Building Dugan Stewart Building May 16, 2012

FS , 712, 713, 714

October 31, Attn: Architects, professional engineers. Design of hazardous areas

ORDINANCE NO.. ARTICLE 1. BUILDING CODE AND RESIDENTIAL CODE International Building Code adopted by reference; amended

CITY OF CRANSTON RESIDENTIAL PERMIT PROCEDURE BASEMENT RENOVATION

2010 National Building Code Adoption and Associated Process Changes

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004

Date of Authorization June 29, 2006 BMEC Authorization Authorization Report - Camino Modular Floor System: SC Series

WON-DOOR CORPORATION Won-Door FireGuard Applications

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

DECK INFORMATION SHEET

HOW TO OBTAIN A BUILDING PERMIT

June 18, 2008 TO: BUILDING CODE USERS

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

USAF Built Infrastructure Inventory and Assessments Manual

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

CITY OF CHICAGO DEPARTMENT OF BUILDINGS

Alternative Solution Approach to Fire Design

HOT SPRINGS FIRE DEPARTMENT EVALUATION REPORT HOWE HOTEL. 201 Central Avenue November 1, 2012

PROPOSED PLAN DEVELOPMENT 2501 WEST HOMER STREET. Guardian Properties, LLC. September 9, 2015

City of La Palma Agenda Item No. 2

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Safety barrier to a deck located adjacent to a retaining wall at Oraka Beach Road, Mahia

Zoning- check the zoning on the property you are planning to build on, this can be done at the municipal office.

Executive Summary. ABSA Building October Project Brief. Introduction

ADMINISTRATION CHAPTER 1

2003 International Residential Building Code

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

STATE UNIVERSITY CONSTRUCTION FUND

CITY OF ST. PETERSBURG PLANNING & ECONOMIC DEVELOPMENT DEPT

Design Manual for M.C.M.E.L Railing System

PART R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT

BUILDING CODES & DESIGN CRITERIA

2015 International Fire Code

Residential Building Permit Application

Transcription:

Ruling No. 01-38-831 Application # 2001-47 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24 (1) of the Building Code Act, 1992. AND IN THE MATTER OF Sentence 3.3.1.17.(1) of Regulation 403, as amended by O. Reg. 22/98, 102/98, 122/98, 152/99, 278/99, 593/99, 597/99 and 205/00 (the Ontario Building Code ). AND IN THE MATTER OF an application by Mr. Joe DiCosimo, owner, 876891 Ontario Limited, Niagara Falls, Ontario, for the resolution of a dispute with Mr. Mel Brown, Chief Building Official, City of Niagara Falls, Ontario, to determine whether the as-installed guard, surrounding a 3 rd floor opening, and being 15 to 30 mm lower in height than the required 1,070 mm, provides sufficiency of compliance with Sentence 3.3.1.17.(1) of the Ontario Building Code at the Hilton Niagara, 6361 Buchanan Avenue, Niagara Falls, Ontario. APPLICANT Mr. Joe DiCosimo, owner 876891 Ontario Limited Niagara Falls, Ontario RESPONDENT PANEL PLACE Mr. Mel Brown Chief Building Official City of Niagara Falls Mr. Len King, Chair (Designate) Mr. John Guthrie Mr. Donald Pratt Toronto, Ontario DATE OF HEARING August 30, 2001 DATE OF RULING August 30, 2001 APPEARANCES Mr. Chris Hawkswell Niacon Ltd. Niagara Falls, Ontario Agent for the Applicant Mr. Robert Romanuk Building & Inspections Coordinator City of Niagara Falls Designate for the Respondent

-2- RULING 1. The Applicant Joe DiCosimo, owner, 876891 Ontario Ltd., Niagara Falls, Ontario, has received a building permit under the Building Code Act, 1992 and has undertaken renovations at the Hilton Niagara, 6361 Buchanan Avenue, Niagara Falls, Ontario. 2. Description of Construction The Hilton Niagara is a 33 storey hotel having a building area of 5,172 m 2. The use is classified as a Group C major occupancy and the building is equipped with fire alarm, sprinkler and standpipe and hose systems. The Applicant has recently undertaken renovations to the structure which includes the construction of an interconnected floor area. The construction in dispute involves the height of the guard that has been installed in this area. The guard has been installed on the third floor of the building and the distance between floor levels is 6.5 m. The third floor primarily houses meeting room facilities and there are no guest suites on this level. The disputed guard that has been constructed is comprised of a handmade glass rail atop a tempered glass balustrade. The handrail is secured to the balustrade with an epoxy. The guard runs around the third floor mezzanine area and proceeds down a grand stair to the first floor lobby. The height of the subject guard ranges between 1,040 mm and 1,055 mm above the finished floor. 3. Dispute The issue at dispute between the Applicant and Respondent is whether the subject guard, constructed approximately 15 mm to 30 mm less than the required 1,070 mm height, provides sufficiency of compliance with Sentence 3.3.1.17.(1) of the Ontario Building Code. The Code requirements in Sentence 3.3.1.17.(1) provide that, with the exception of certain circumstances not applicable here, a guard of not less than 1,070 mm will be provided at each raised floor, mezzanine balcony, etc., where the difference in floor level is more than 600 mm. In this instance, the third floor opening requires that a guard be provided as the difference in floor levels is 6.5 m. The height of the guard is mandated by the Code at 1,070 mm. However, a guard ranging from 1,040 mm to 1,055 mm has been provided at this level. 4. Provisions of the Ontario Building Code 3.3.1.17. Guards (1) Except for the front edges of stages, floor pits in repair garages and loading docks, a guard not less than 1 070 mm (3 ft 6 in) high shall be provided (a) around each roof to which access is provided for other than maintenance, (b) at openings into smoke shafts referred to in Subsection 3.2.6. that are

-3- (c) less than 1 070 mm (3 ft 6 in) above the floor, and at each raised floor, mezzanine, balcony, gallery, interior or exterior vehicular ramp, and at other locations where the difference in level is more than 600 mm (23e in). 5. Applicant s Position The Agent for the Applicant submitted that the handrail and associated glass balustrade are considered a major architectural feature of the mezzanine at the third level of the hotel. The architectural drawings submitted in connection with this application specified a guard that would have met the Building Code height requirement. Unfortunately, the guard was installed at a height less than what was intended. This discrepancy was not identified until the guard was almost completed. The Agent advised that, because of the material used in the installation of the guard, it would be virtually impossible to remove the handrail from the glass guard. The rail itself is a handmade, blown glass feature that has been secured to the glass guard with a potent epoxy. The guard assembly was an expensive item to install and would be equally expensive to redo at this point. The Agent advised that he had considered options that would achieve compliance but, to change the handrail, or add height to it in some way, would take away from the clean line of the feature. Alternatives that had been explored were not aesthetically pleasing. The Agent suggested that the existing guard height represents only a slight variation from the Code requirement. He requested that the Commission consider making a ruling of sufficiency of compliance in this regard in light of this marginal difference. The Agent and the Applicants architect were of the opinion that the discrepancy in guard height would pose no added danger to any person using the third floor area. They submitted that the height requirement in the Code was calculated to approximate the waist height of an average adult with the intent of this provision being to prevent a fall. The existing guard, varying only slightly from the requirement, meets the intent of the OBC in this regard. Safety, it was argued, would not be compromised with a shortfall of approximately one inch. 6. Respondent s Position The Respondent submitted that, upon inspection of the floor area, it was discovered that the height of the guard did not meet the Code requirement of 1,070 mm. He is not especially concerned by the difference in height but his hands are tied by the Code provisions. He recognized that it was the Applicant s intent to have a Code compliant guard and that an error occurred in the execution of the architectural drawings. He reiterated, however, that anything less than 1,070 mm did not comply with the strict wording of the Building Code and, therefore, could not be approved by the municipality.

-4-7. Commission Ruling It is the decision of the Building Code Commission that the as-installed guard, surrounding a 3 rd floor opening, and being 15 to 30 mm lower in height than the required 1,070 mm, provides sufficiency of compliance with Sentence 3.3.1.17.(1) of the Ontario Building Code at the Hilton Niagara, 6361 Buchanan Avenue, Niagara Falls, Ontario. 8. Reasons i) The height of the existing railing is only slightly lower than the required guard height. ii) This is an as built condition that occurred as a result of an execution error by the installer. iii) It would be difficult to remedy the situation at this stage of construction. The guard is not easily disassembled and replaced.

Dated at Toronto this 30th day in the month of August in the year 2001 for application number 2001-47. -5- Mr. Len King, Vice-Chair Mr. John Guthrie Mr. Donald Pratt