City of Margate, Florida Building Department MINIMUM PERMIT REQUIREMENTS FOR FENCES

Similar documents
Fence - Residential Permit Guidelines

BERKELEY COUNTY ENGINEERING AND

FENCE PERMIT APPLICATION

City of Combine CONTRACTOR REGISTRATION FORM TYPE OF CONTRACTOR LICENSE CONTRACTOR INFORMATION

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

City of Margate, Florida Building Department. Minimum Permit Requirements For Roofing

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES (PARK)

REQUEST FOR BIDS METROPOLITAN PARK DISTRICT OF TACOMA Northwest Trek Core Area Fence Upgrade SWR BID NO. T Request for Bids

FENCES. This hand out is for REFERENCE ONLY. For more details see specific code sections.

RESIDENTIAL FENCE STANDARDS

POST FRAME BUILDING STANDARDS

A. Product Data shall be provided for each type of product indicated.

CHAPTER 4 FENCE REGULATIONS

FENCE & RETAINING WALL PERMIT CHECKLIST

SWIMMING POOL PERMIT AND INSPECTION REQUIREMENTS

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

ROOFING PERMIT APPLICATION PACKAGE

City of Bullhead City Development Services/Public Works. Permit Submittal Requirements FENCES

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

CHAIN LINK FENCES AND GATES

Section , Article 4 of the Zoning Ordinance December 14, 2012 Page 1 of 8

CITY OF HOMESTEAD Utility Rights-of-Way Use Permit Application

Reliant Holdings Ltd Safety Management System

SECTION 1043 FENCE MATERIAL

REQUEST FOR ARCHITECTURAL REVIEW AND HOA APPROVAL - PHEASANT WALK HOMEOWNERS ASSOCIATION, INC.

City of New Haven. 101 FRONT STREET PO BOX 236 NEW HAVEN, MO Phone * * Fax

Fence and Wall Requirements

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708

Definitions. The following words and phrases, when used in this article, shall have the following meanings respectively ascribed to them:

SECTION TRENCHING & BACKFILLING

RESIDENTIAL BUILDING PERMIT PROCEDURES

SECTION CHAIN LINK FENCES AND GATES

CITY OF GLASGOW BUILDING PERMIT APPLICATION 126 E. Public Square Glasgow, KY Phone: (270) Fax: (270)

Fences. Facts to Know

Re-Roof Permit Checklist

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

REQUEST FOR ARC APPROVAL

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

Special Provision No. 540S01 March OPSS 540, Construction Specification for Highway Fence, is deleted and replaced with the following:

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

Why Do I Need a Permit? D ID Y OU K N OW? Protects property values. Makes Selling Property Easier. Site Plan Page 2. Plan Requirements Page 2

CBUCK Engineering. Evaluation Report Englert Series 500 Metal Roof Assembly Manufacturer: Englert, Inc Amboy Avenue Perth Amboy, NJ

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

A. Coordinate chain link fence & gate work with work before and after. See especially: 1. Bollards on worksite that are more than 10 ft from fence.

PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

One and Two Family Additions

Basic Service. This Section provides information regarding a. Introduction

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

CBUCK Engineering. Florida Product Approval # FL R2

02800 SHADE STRUCTURES

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

CITY OF ST. PETERSBURG PLANNING & ECONOMIC DEVELOPMENT DEPT

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Administrative Changes

CBUCK Engineering. Evaluation Report Cee Lock Panel Metal Roof Assembly

CBUCK Engineering. Product: Zee-Lock Roof Panel Material: Steel Panel Thickness: 24 gauge Panel Width: 16 Support: Wood Deck

Gainesville Technical Center 5399 Wellington Branch Drive Gainesville VA Phone (703)

DEPAUL UNIVERSITY. Scaffolding Program. Environmental Health & Safety. April 2017

Electric Service Standards

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

City of Augusta SIDEWALK REPLACEMENT PROGRAM

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

Residential Building Inspections

CHAPTER 62B-34 GENERAL PERMITS FOR ACTIVITIES SEAWARD OF THE COASTAL CONSTRUCTION CONTROL LINE

TOWN OF DEWITT PLANNING AND ZONING PERMIT REQUIREMENTS FOR DECKS

COMMUNITY DEVELOPMENT

MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Marbella Isles Homeowners Association, Inc.

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)

Request for a Fence Exemption - 10 Charnwood Road. Pat Burke, District Manager Municipal Licensing & Standards, North District

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

NASSAU COUNTY ELECTRICAL PERMIT APPLICATION FOR CONTRACTORS

Last Updated March 15, 2016

BYRON TOWNSHIP BUILDING PERMIT APPLICATION 8085 Byron Center Ave SW., Byron Center, MI /Fax

Penn State Forestland Management Office Multi-Strand High-Tensile Wire Fence Specifications

Miami Dade Building Code Compliance Office Notice of Acceptance

Evaluation Report. Die Formed Skirt Ridge Ventilator. "12 Inch Throat" Manufacturer. Metallic Products Corporation Hollister Road

SECTION STAINLESS STEEL FLEXIBLE CABLE MESH. Show hidden Specifier Notes for best results

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

2003 International Residential Building Code

Whispering Woods Community Association Architectural Rules and Regulations

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

RESIDENTIAL BLOCK WALL/ FENCE APPLICATION

Management Plan for Walking/Working Surfaces & Fall Protection (29 CFR , 23, 66 App.C; 29 CFR ) ISD #535

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

MONROE COUNTY ZONING OFFICE

INC. VILLAGE OF COVE NECK OFFICE: (516) FAX: (516)

Installation Guide and Safety Manual

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

TREE PRESERVATION & PROTECTION PERMIT APPLICATION INSTRUCTIONS

Transcription:

MNMUM PERMT REQUREMENTS FOR FENCES PERMT APPLCATON COMPLETELY FLLED OUT SGNED AND NOTARZED HOMEOWNER S AFFDAVT (when obtaining a Owner/Builder Permit) EASEMENT AGREEMENTS, APPROVED BY THE FVE UTLTY COMPANES THAT SERVCE MARGATE (when structure is to be constructed in a utility easement) THE FOLLOWNG DOCUMENTS MUST BE SUBMTTED N DUPLCATE NOTCE OF COMMENCEMENT F OVER $ 2,500.00 N VALUE STE SURVEY SHOWNG LOCATON & HEGHT OF FENCE, AND LOCATON OF GATES FENCES FOR NEW OR EXSTNG POOLS FLORDA BULDNG CODE SECTON R 4101.17 (Signed by owner and contractor, f applicable) CTY OF MARGATE WOOD & CHAN LNK FENCE REQUREMENT FORM (f applicable) NOTCE OF ACCEPTANCE (NOC) OR SGNED AND SEALED ENGNEERS DRAWNGS FOR PVC AND ALUMNUM FENCES. (f applicable) THE PERMT APPLCATON WLL NOT BE ACCEPTED WTHOUT THE ABOVE MNMUM DOCUMENTATON OTHER DOCUMENTS MAY BE REQURED DEPENDNG UPON THE JOB CONDTONS Zoning Requirements Contact the City of Margate Zoning Department For Current Set Back & Height Restrictions 954-972-0828

FENCES FOR NEW OR EXSTNG POOLS FLORDA BULDNG CODE SECTON R 4101.17 R4101.17.1.4 Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches, the horizontal members shall be located on the swimming pool side of the fence. Spacing between the vertical members shall not exceed 1-3/4 in width. Where there are decorative cutouts within the vertical members, spacing within the cutouts shall not exceed 1-3/4 inches in width. R4101.17.1.5 where the barrier is composed of horizontal members and the distance between the tops of the horizontal members is 45 inches or more, spacing between vertical members shall not exceed 4 inches. Where there are decorative cutouts within vertical members, spacing in the cutouts shall not exceed 1-3/4 inches. R4101.17.1.6 Maximum mesh size for chain link fences shall be 2-1/4 inches square unless the fence is provided with slats fastened at the top or bottom which reduce the openings to no more than 1-3/4 inches. R4101.17.1.7 Where the barrier is composed of diagonal members, the maximum opening formed by the diagonal members shall not be more than 1-3/4 inches. R4101.17.1.8 Access gates when provided, shall be self closing and shall comply with the requirements of Sections R4101.17.1.1 through R 4101.17.1.7 and shall be equipped with a self latching locking device located on the pool side of the gate. Where the device release is located no less than 54 inches from the bottom of the gate, the release mechanism may be located on either side of the gate and so placed that it cannot be reached by a young child over the top or through any opening or gap from the outside. Gates that provide access to the swimming pool must open outward away from the pool. The gates and barrier shall have no opening greater than ½ inch within 18 inches of the release mechanism. /WE THE UNDERSGNED HAVE READ AND UNDERSTAND THE REQUREMENTS OF THE FLORDA BULDNG CODE FOR FENCE NSTALLATONS Owner s Signature Contractor s Signature

WOOD & CHAN LNK FENCE REQUREMENT FORM CHAN LNK FENCES FLORDA BULDNG CODE- R 4408.11 TABLE R4408.11 CHAN LNK FENCE MNMUM REQUREMENTS CHAN LNK FENCES OVER 12 FEET HGH SHALL BE DESGNED ACCORDNG TO SECTON R 4403 CHAN LNK FENCES LESS THAN 12 FEET HGH MAY BE CONSTRUCTED N ACCORD WTH TABLE R 4408.11 Terminal Post Concrete Line Post Concrete Terminal Post Dimensions Line Post Dimensions Foundation Size Foundation Size (Diameter X Depth) (Diameter X Depth) (O.D. x Wall Thickness) (O.D. x Wall Thickness) Up to 4 2-3/8 x 0.0042 1-5/8 x 0.047 10 x 24 8 x 24 Over 4 to 5 2-3/8 x 0.0042 1-7/8 x 0.055 10 x 24 8 x 24 Over 5 to 6 2-3/8 x 0.0042 1-7/8 x 0.065 10 x 24 8 x 24 Over 6 to 8 2-3/8 x 0.110 2-3/8 x 0.095 10 x 36 10 x 36 Over 8 to 10 2-7/8 x 0.110 2-3/8 x 0.130 12 x 40 10 x 40 Over 10 to 12 2-7/8 x 0.160 2-7/8 x 0.120 12 x 42 12 x 42 For S: 1 nch=25.4 mm. Notes: 1. This table is applicable only to fences with unrestricted airflow. 2. Fabric: 12 ½ gauge minimum. 3. Tension Bands: Use 1 less than the height of the fence in feet evenly spaced. 4. Fabric Ties: Must be Minimum the same gauge of the fabric. 5. Fabric Tie Spacing on the Top Rail: Five ties between the posts evenly spaced. 6. Fabric Tie Spacing on Line Posts: One less than the height of the fence in feet evenly spaced. 7. Either Top Rail or Top Tension wire shall be used. 8. Braces must be used at Terminal Posts if top tension wire is used instead of Top Rail. 9. Post Spacing: 10 (3m) on center maximum. 10. Posts shall be embedded to within 6 (152m) from the bottom of the foundation. 11. n order to follow the contour of the land, the bottom of the fence may clear the contour of the ground by up to 5 inches (127mm) without increasing table values to the nest higher limit. 12. Structural side of fence must face owner s property. WOOD FENCE TYPES WOOD FENCES FLORDA BULDNG CODE SECTON- R 4409.15 6 FOOT HGH MAXMUM 4 X 4 X 8 PRESSURE TREATED POST SET N CONCRETE FOOTNG 10 N DAMETER BY 2 DEEP SPACED 4 ON CENTER. FENCES 5 HGH POSTS MAY BE SPACED 5 ON CENTER FENCES 4 HGH POSTS MAY BE SPACED 6 ON CENTER Board on Board Stockade Shadow Box Basket Weave

WOOD FENCE Section 2328 FBC 6'0" Maximum 6'0" Maximum i 'O" -..---- --- - 2'0" i! 2.x4 No. 3, So. Pine PT Wood Rails Attached to Post ---- -- With four 10d Nails (m!n.). 4 No. 2, So. Pine T "l pac ed as follows nee hei ght Post 6-0'' 4'-0" o.c. Ji 5'-0" 5'-0" O.C. 1. ḷ. bove grade Spacing -,4 --- i 2'0"!1-4'-0 " 6'-0" 0.! -- -- Wood Pickets 5/8" minimum thickness \ _Ṭ.i....- attached to each rail with 2 nails that penetrate at least Yi the thickness of the rail. 1 1'0" 2'0" 10' Diameter Concr ete filled hole 901 NW 66 th Avenue, Margate, Florida 33063-3699 Telephone 954-970-3004 Facsimile 954-970-34

EASEMENT AGREEMENT City of Margate, Florida Date: Attn: Notice: This is not a Building Permit., propose to apply for a building permit to construct a in the Utility Easement, Drainage Easement, Canal Maintenance Easement, at my property located at Legal Description: Lot Block Subdivision in the City of Margate, Florida. (*See attached survey) A brief description of the type of construction and location of the proposed construction is as follows: understand that your company will not be responsible in any way for repairs to, or replacement of, any portion of this and that any removal and replacement of this construction necessary for the use of this easement will be done at my expense. further understand that will assume full responsibility for any damage incurred to the utility facilities during the construction. This is to certify that am the lawful owner(s) of the subject property and agree to the proposed construction as described above. Signature of Owner Date Contact Phone Number Address Return Fax Number City State Zip Note: This agreement must be attached to a building permit when completed. We agree disagree with comments noted with the proposed construction based upon the circumstances stated herein: --------------------------------------------------------------------------------------------------------- Name of Utility Company: Representative: Title and Date: Utility Companies: AT&T Southeast (Bell South) 8601 W. Sunrise Blvd. Plantation, Florida 33324 (Fax: Attn: Lisa Golitz. Engineering 954-423-6108) Comcast Cable 2601 SW 145 1 h Ave., Suite 100 Miramar, Florida 33027 (Fax Attn: Leonard Maxwell-Newbold@ cable.comcast.com City of Margate, Florida (DEES) 901 NW 66 1 h Ave., Suite A, Margate, Florida 33063 (Fax: Attn: Abe Stubbins. 954-978-7349) FPL Customer Service Department 330 S.W. 12'h Ave., Pompano Beach, Florida (Fax: Attn: Shavonti Archer. Engineering 954-956-2020) TECO (People's Gas) Engineering Department 16101 W. Dixie Highway North Miami Beach, Florida 33162 (Fax: Attn: Gloria Garard. Engineering 1-305-945-0171) *Additional information needed: Survey. 5/20/15 revised

DURNG A HURRCANE WATCH & BEFORE THE ONSET OF HURRCANE VELOCTY WNDS YOU ARE REQURED TO SECURE THS JOB N ACCORDANCE WTH THE BROWARD COUNTY ADMNSTRATVE PROVSONS OF THE FLORDA BULDNG CODE SECTON 109.12 All loose objects n exposed outdoor locations shall be lashed to rigid construction or shall be stored in buildings. Florida Building Code Broward County Administrative Provisions Section 109.12.2.4 NOTCES SSUED BY THE NATONAL WEATHER SERVCE OF A HURRCANE WATCH ARE DEEMED SUFFCENT NOTCE TO THE OWNER OF REAL PROPERTY UPON WHCH CONSTRUCTON S OCCURRNG, OR ANY CONTRACTOR RESPONSBLE FOR SAD CONSTRUCTON, TO SECURE LOOSE CONSTRUCTON DEBRS AND LOOSE CONSTRUCTON MATERALS AGANST EFFECTS OF HURRCANE FORCE WNDS This includes but not limited to: 109.12.2.1 Road Right-of-Way shall remain clear of construction waste and trash 109.12.2.2 Waste and Trash Enclosures Temporary Toilets 109.12.2.3 Loose Construction Debris Forms and Construction Materials 109.12.2.5 Roofing Tile and Materials Construction Shacks Temporary Electric Service Poles AND PROTECT ALL GLASS AREAS