Indoor Air Quality Management Plan

Similar documents
New Montgomery County Elementary School. Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction

Draft Indoor Air Quality Regulations

INDOOR AIR QUALITY PLAN

Model Written Indoor Air Quality Program. The Summit Board of Education Administrative Offices 14 Beekman Terrace Summit, NJ

Construction Indoor Air Quality (IAQ) Management Plan

Indoor Air Quality Plan

General Specifications for HVAC System Cleaning

Indoor Air Quality Program

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

Indoor Air Quality Tools for Schools

DESIGN & CONSTRUCTION PHASE COMMISSIONING PLAN TEMPLATE

What Contractors Need to Know about LEED Commissioning & IAQ Management

MOLD REMEDIATION PROCEDURES

LEED And Your Indoor Environment

Table of Contents. C. Recommended Remediation Firms: upon request

Before You Start Renovating Your Bathroom

Safety & Risk Management Policies and Procedures Mold Policy and Procedure Safety & Risk Management Policies and Procedures

SECTION SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES

Indoor Air Quality (IAQ) Tailoring Lease Specifications S-852

Fixed Facility Owners & Managers

ASHRAE and Indoor Air Quality

In the school year, U.S. K-12 public schools provided instruction to over 46 million

Proactive Moisture Management Plan

Standard Operating Procedures for Servicing Laboratory Exhaust Systems

Indoor Air Quality Improvement in a School Building in Delhi

SECTION AIR DUCT CLEANING

INDOOR AIR QUALITY. Ir Al-Khairi Mohd Daud. Pakar Keselamatan dan Persekitaran

CLASS I AND II ABATEMENT PROJECT SUBMITTALS

Flood / Mold Remediation (FMR) 29 CFR

LEED v4 Building Design and Construction Quiz #8 EQ

INFECTION CONTROL ISSUES IN CONSTRUCTION AND RENOVATION

IAQ Walkthrough. Jordan Elementary. J o r d a n P u b l i c S c h o o l s IEA, INC. Contact Us: Inspection Date:

Indoor Building Survey and Product Inventory

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

Brown University Updated March 11, 2013 Facilities Design & Construction Standards

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

PI s Name Date Bldg./Rm#

Improving Indoor Air Quality. Presented by Theo Cole, EIT

Protecting the HVAC System During Construction: An Industry Standard of Care for Contractors

CASE STUDY. Two Dogs and Two Cats Insufficient Air Exchange with High CO2

Environmental Conditions Laboratories (for commercial use) Group

Infection Control Risk Assessment Matrix of Precautions for Construction & Renovation

Pesticide Safety Program

STEP UP TO THE ENERGY STAR INDOOR AIR PACKAGE. A new opportunity for leading builders to create better environments inside and out

SEED WAREHOUSE & DISTRIBUTION CENTER AUDIT

Technical Guide Towards Energy Smart HOTEL. Energy Sustainability Unit. Department of Building National University of Singapore.

Background. AEM Tier 2 Worksheet Greenhouse Maintenance

FACILITIES MAINTENANCE WORKER

Illinois Department of Public Health Guidelines for Indoor Air Quality

breathe easier FILTRATION

UI Procedures for Asbestos Management

Retail Food Establishment. Self-Assessment Checklist. for. Food Defense

GUIDELINES FOR LABORATORY USE OF CHEMICAL CARCINOGENS

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction

CALGREEN NON-RESIDENTIAL BUILDING Checklist

MOLD INSPECTION REPORT Block Home Inspections LLC

Risk Assessment and Preventive Measures Checklist for Construction and Renovation. Location of Construction: Project Start Date: Estimated Duration:

Fresh Air Ideas SUPPORTING GREEN INITIATIVES WITH INNOVATION

DUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM

A Building Commissioning Overview. Presented by: Goetting & Associates Commissioning

Environmental Leadership Program Inspection Form Portable Asphalt Facility

Water Intrusion Management Plan for Construction Firms. XL Group Insurance. Risk Control Guidance. Environmental

1.1 SUMMARY.1 Comply with requirements of this Section when performing the following work:

ATTACHMENT N LEED PROJECT PROCEDURES

Best Management Practices

LEAD-BASED PAINT PRESENT

Mold Report Writing

THE REVISION OF STANDARD 62: WHAT A DIFFERENCE A DECADE MAKES

Lead Based Paint Policy

InterNACHI. Advanced Inspection of Crawlspaces for home inspectors

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system.

HOW DO YOU TALK ABOUT MOLD WITHOUT SAYING THE M WORD IMG = A NEW NAME FOR AN OLD PROBLEM. Mold Growth!

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies.

EPA s Lead Program Rule At-A-Glance

SECTION CLOSEOUT PROCEDURES

HOW TO BUILD AN ENVIRONMENTALLY RESPONSIBLE HOME

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

To establish criteria for construction, renovation and maintenance regarding infection prevention and control measures.

Escondido Best Management Practices (BMP s)

Microbial Contamination

Minimum Standards for Building Occupancy. Safety Resources

Safety and Environmental Orientation and Practices for Contractors

VERMONT MAPLE SUGAR MAKERS ASSOCIATION 491 East Barnard Road South Royalton, VT SUGARING OPERATIONS CERTIFICATION SCORE SHEET

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

DEMAND CONTROLLED VENTILATION (DCV) SYSTEMS

START WORK NOTIFICATION

HFM Asset Management Contractor Induction Queens Riverside Apartments

SUMMARY OF OUR FINDINGS

Hazard Recognition and Assessment

How Do You Spell IAQ? BY HOME ENERGY MAGAZINE

Appendix II FSEP Prerequisite Program Checklist

Industrial Ventilation System Monitoring & Maintenance

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE

ASBESTOS AWARENESS. Supplement to Standard Training Module

Of Building Science: From Control Layers to High Performance Enclosures

OPERATIONS AND MAINTENANCE ESSENTIALS

Local Exhaust Ventilation Improvement Efforts at a Global Specialty Chemical Manufacturer

TN Tatem Middle School Indoor Air Quality Assessment September 2016

AUBURN UNIVERSITY RISK MANAGEMENT & SAFETY

Transcription:

Indoor Air Quality Management Plan Environmental Health, Safety, and Risk Management Department Box 6113, SFA Station Nacogdoches, Texas 75962-6113 Established: May, 26, 2010 Revised: January 2011

Introduction Concerns with Indoor Air Quality (IAQ) have increased since energy conservation measures were instituted in office buildings during the 1970s, minimizing the infiltration of outside air and contributing to the buildup of contaminants in the indoor air. Complaints about IAQ range from simple complaints from comfort issues (too hot/cold/drafty, etc.) and odd smells, to more complex problems, where the air quality may be suspected of causing illness and lost work time. It may not be easy to identify a single reason for IAQ complaints because of the number and variety of possible sources, causes, and varying individual sensitivities. Nevertheless, Stephen F. Austin State University is committed to providing its students, employees, and visitors an indoor environment free of contaminants and airborne disease agents. IAQ Coordinator The IAQ Coordinator at Stephen F. Austin State University is Ray Robberson. The IAQ Coordinator is responsible for managing the Indoor Air Quality Management Program at Stephen F. Austin State University. IAQ Coordinator responsibilities include: Training employees in the recognition, prevention, and resolution of IAQ problems. Communicating with building occupants concerning IAQ issues or problems. Developing a procedure for documenting and responding to IAQ complaints and problems. Maintaining IAQ records. IAQ records include: IAQ complaints and resolutions; and documentation of any maintenance, repair, or remodeling activity that could adversely impact indoor air quality. Conducting an annual, at the minimum, documented inspection of the premises. Conducting periodic walkthroughs to assess the current IAQ situation The IAQ coordinator or designate conducts periodic walkthrough inspections which involves both occupied areas and mechanical rooms. During the walkthrough, IAQ problem indicators are checked and noted on a floor plan or comparable drawing, including: Odors Dirty or unsanitary conditions Visible fungal growth or moldy odors Evident moisture in inappropriate locations (e.g., moisture on walls, floors, or carpets) Staining or discoloration of building material(s) Smoke damage Presence of hazardous substances Unusual odors from equipment Poorly-maintained filters Uneven temperatures

Personal air cleaners (e.g., ozone generators, portable filtration units) or fans Inadequate ventilation Inadequate exhaust air flow Blocked vents Other conditions that could impact IAQ, especially risk factors that need regular inspection to prevent IAQ problems from occurring (e.g., drain pans that do not fully drain). The condition and operations of the HVAC system are inspected, including: Components that need to be repaired, adjusted, cleaned, or replaced have been, and work orders prepared. Actual control settings and operating schedules for each air handling unit have been recorded and filed, and checked against the design intent. Areas with significant sources of contaminants (e.g., copy rooms, food service areas, printing/photographic areas) are provided with adequate exhaust. Other sources are moved as close to exhaust as possible. Existing and Potential IAQ Problems The IAQ Coordinator conducts an ongoing assessment of agency buildings for existing problems. Identified IAQ problems are corrected and steps are taken to control them, including both sourcerelated IAQ problems and ventilation-related IAQ problems. Training The IAO corridinator provides IAQ training and information to agency personnel and contractors - especially regarding use of hazardous chemicals. Plan for Facility Operations and Maintenance HVAC Operations Operating schedules for HVAC equipment have been written and are updated as needed. Preventive Maintenance Stephen F. Austin State University preventive maintenance plan has been written and is followed on a regular schedule; this schedule is updated as needed. The preventive maintenance plan or contract includes the following maintenance items: Outside air intakes are inspected for nearby sources of contaminants Air distribution dampers are maintained clear of obstructions and operating properly Air filters have the pressure drops monitored, and replacement or cleaning is performed regularly Drain pans are inspected and cleaned to ensure proper drainage

Heating and cooling coils are inspected and cleaned Interior of air handling units are inspected and cleaned, as warranted Fan motor and belts are inspected and replaced as warranted Air humidification and controls are inspected and regularly cleaned Cooling towers are inspected, cleaned, and water treated according to schedule Air distribution pathways and VAV boxes are inspected and cleaned as needed. The preventative maintenance plan and operation manuals are updated when equipment is added, removed, or replaced. Unscheduled Maintenance Procedures for unscheduled maintenance events (e.g., equipment failure) have been written and communicated to building staff. They include: Agency personnel immediately contact the IAQ Coordinator that a maintenance event has occurred. The IAQ Coordinator ensures that notification to occupants is provided in a timely manner, addressing how IAQ is being protected. Any necessary remedial action is then taken. The IAQ Coordinator then informs occupants that corrective actions have been completed. Housekeeping All housekeeping equipment and products used in the building are communicated to the IAQ Coordinator. Additionally, housekeeping maintains an inventory of all chemicals used, and keeps the IAQ Coordinator updated on the inventory. The products used at Stephen F. Austin State University that may produce strong odors, are potential irritants, or may have other IAQ impacts have been determined, and, where possible, have been replaced by products without such impacts. The Stephen F. Austin State University Housekeeping Director has written procedures that detail proper use, storage, and purchase of cleaning materials; these are updated as needed. The housekeeping staff or contractors are educated about the IAQ implications, appropriate use, and application of the following to improve IAQ: Proper cleaning methods Cleaning schedules Proper materials storage and use Proper trash disposal Management of Processes with Potentially Significant Pollutant Sources Purchasing Practices When new products are purchased, information on potential indoor air contaminant emissions is requested from product suppliers. [Note: Emission information may not be readily available for

many products; however information that is available is collected.] When the services of architects, engineers, contractors, or other professionals are used, IAQ concerns, such as special exhaust needs, are discussed. Remodeling and Renovation Procedures to minimize the generation and migration of contaminants or odors to occupied areas of the building are used and required of contractors. The procedures used at Stephen F. Austin State University are: The IAQ Coordinator and Risk Manager review designs and construction activities for all proposed remodeling and renovation activities prior to their initiation Work is scheduled during periods of minimum occupancy Ventilation is provided in order to isolate work areas Lower-emitting work processes are used (e.g., wet-sanding dry wall) Specialized cleaning procedures are used (e.g., use of HEPA vacuums) Filters are changed more frequently, especially after work is completed Emissions from new furnishings are minimized (e.g., buying lower-emitting airing out furnishings before installation, increased amount and duration of after installation) Ventilation and distribution equipment are protected from contamination during construction. Painting Exposure to paint vapors is minimized by using low-emitting products, scheduling work during periods of minimum occupancy, and increasing ventilation. Pest Control Integrated Pest Management procedures are used to the extent possible: The pest control products being used in the building are communicated to the IAQ Coordinator. Written procedures and contract language ensure that all people who use pest control products read and follow all label directions for proper use, mixing, storage and disposal. Non-chemical pest control strategies are used where possible. The safest available pest control products that meet the building s needs are used or reviewed with pest control contractor. Shipping or Receiving Activities Vehicle exhaust will be handled on a case by case incident and all precautions will be made to keep all fumes from entering a building. Some areas to be checked are including through air intakes and building openings and some of the correct measures can be by installing barriers to airflow from loading dock areas (e.g., doors, curtains, etc.) and using pressurization to prevent mixing of vehicle exhaust with building air.

Smoking Smoking is prohibited in all Stephen F. Austin State University buildings, subject to the University Smoking Policy. Maintaining Cooperative Relations with Occupants The IAQ Coordinator keep occupants routinely informed about building conditions and policies that may impact IAQ (e.g., practices that attract insects or smoking policy clarifications). Additionally, occupants are notified about planned major renovation, remodeling, maintenance or pest control activities. Procedures for Responding to IAQ Complaints Procedures for responding to IAQ complaints have been written and are followed, including: IAQ problems are logged into the existing work-order system. Information is collected from complainants. Information and records obtained from complainants are kept confidential. The capability of in-house staff to respond to complaints is assessed. Appropriate outside sources of assistance are identified. Feedback is provided in a timely manner to the complainant. Remedial actions are taken. Remedial actions are followed-up to determine if the action has been effective. Building staff have been informed of these procedures. Building occupants have been informed of these procedures and are periodically reminded of how to locate responsible staff and how to submit a complaint. Note: The State Office of Risk Management and Stephen F. Austin State University thanks Clemson University Environmental Health and Safety for their assistance in the preparation of the Indoor Air Quality Management Plan.