Impacts of Indoor Temperature and Velocity on Human Physiology in Hot Summer and Cold Winter Climate in China

Similar documents
A Field Study of the Thermal Environment in Residential Buildings in Harbin

Designing Air-Distribution Systems To Maximize Comfort

Thermal Comfort Evaluation of HDB flats

Bio Climatic Analysis of Bhubaneswar-An Investigation to Arrive Human Comfort through Natural Ventilation

The Response of Human Thermal Perception and Skin Temperature to Step-Changed Activity Level

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

A Solar Wall System Utilized in Rural Houses of Northeast China

Adaptive Thermal Comfort in Warm Dry Climate: Economical dwellings in Mexico

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

Indoor climate The adaptive approach to thermal comfort

Thermal Comfort in Architecture

Work environment. Microclimate - definition. Main microclimate elements. Core temperature. Microclimate

Energy and Thermal Comfort Management in a Kindergarten School Building in the South of Portugal in Winter Conditions

IMPLICATIONS OF CLIMATE CHANGE AND OCCUPANT BEHAVIOUR ON FUTURE ENERGY DEMAND IN A ZERO CARBON HOUSE

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

Assessment of Indoor Climate: Learning from Buildings

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

Retrofitting Adaptive Comfort Strategies into Conventionally Air Conditioned Commercial Buildings

Thermal comfort conditions in outdoor spaces

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Lesson 29 Inside And Outside Design Conditions. Version 1 ME, IIT Kharagpur 1

Personalized conditioning with human-in-the-loop control approach

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Micheal Okpara University of Agriculture Umudike. Abstract

Verification of Chiller Performance Promotion and Energy Saving

Cool spots in hot climates: a means to achieve pedestrian comfort in hot climates

Practical Guide Comfort level measurement in the workplace :32. PMV PPD measurement protocol Default Point Graphic Date/Time

681: Environmentally Responsive Architecture; Passive Design for School in Southern India

EMBEDED SYSTEM FOR MONITORING THE TEMPERATURE INSIDE A VEHICLE

Bio-climatic Chart for Different Climatic Zones of Northeast India

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

NUMERICAL SIMULATION OF CAR COCKPIT HEATING DURING WINTER 1

A Thermal Comfort Investigation of a Facility Department of a Hospital in Hot-Humid Climate: Correlation between Objective and Subjective Measurements

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Procedia Engineering 145 (2016 ) 18 25

Outdoor Thermal Comfort in the Hot Arid Climate The effect of socio-economic background and cultural differences

Integrated BIPV performance assessment for tropical regions: a case study for Bangalore

Busting the Myth: Passive Houses Only Work in Cold Climates. (The Comfort Proposition)

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

Sensing Occupant Comfort using Wearable Technologies

ENERGY AND THERMAL COMFORT EVALUATION FOR DIFFERENT PASSIVE SOLUTIONS IN A KINDERGARTEN IN SUMMER CONDITIONS.

Assessments of indoor environmental quality on occupant satisfaction and physical parameters in office buildings

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Natural Ventilation Approached on Circular Courtyard Building in Hot Humid Climate

DISPLACEMENT VENTILATION

Performance-Risk Methodology for the Design of High-Performance Affordable Homes

Thermal effect of temperature gradient in a field environment chamber served by displacement ventilation system in the tropics

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Thermal Delight in Architecture

Thermal Delight in Architecture

LOCAL VENTILATION SYSTEMS: SOME INVESTIGATIONS ABOUT COMFORT LEVELS AND ENERGY DEMANDS

SICK BUILDING SYNDROME SYMPTOMS AND PERFORMANCE IN A FIELD LABORATORY STUDY AT DIFFERENT LEVELS OF TEMPERATURE AND HUMIDITY

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

Evaluating Thermal Comfort in a Naturally Conditioned Office in a Temperate Climate Zone

Perceived Thermal Discomfort and Stress Behaviours Affecting Students Learning in Lecture Theatres in the Humid Tropics

Experimental investigation of zero energy office under natural and forced ventilation

Assessing the ability of PMV model in predicting thermal sensation in naturally ventilated buildings in UK

UC Berkeley Indoor Environmental Quality (IEQ)

125BEPM - Building energy performance modeling. Lecture handouts

Work Package 2: Performance of naturally ventilated buildings

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Comparison of the Intensity of Ventilation at Windows Exchange in the Room - Case Study

A field study of the performance of the Dutch Adaptive Temperature Limits guideline

Facilities Management System That Reduces Environmental Burden of Buildings

TABS, THERMAL ACTIVATED BUILDING SYSTEM, TO IMPROVE COMFORT IN SCHOOLS

Cellulose. The Convenience of Insulation

THE EFFECTS OF URBAN HEAT ISLAND MITIGATION STRATEGIES ON THE OUTDOOR THERMAL ENVIRONMENT IN CENTRAL TOKYO A NUMERICAL SIMULATION

ENERGY EFFICIENCY IN BUILDINGS AND COMMUNITIES

Heat Rejection using Cooling Towers

Adaptive buildings' facades for thermal comfort in hot-humid climates

Investigation and Analysis of the Indoor Air Environment of a Large-scale Art. Exhibition Hall in Beijing

Casa Ecologica: Warmer at low cost in winter, colder at no cost in summer

Introduction to basics of energy efficient building design

University of Wisconsin La Crosse Centennial Hall LEED Credit 7.2 Thermal Comfort Plan

Influence of Retro-reflective Material on Public Buildings Energy Consumption in Different Climate Regions

Thermal Comfort Survey in Office Buildings in Bandung, Indonesia

SUSTAINABLE BY PASSIVE ARCHITECTURE, USING COURTYARDS IN NON-DOMESTIC BUILDINGS IN SOUTHEAST QUEENSLAND

Canada Published online: 28 Feb 2011.

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

Evaluation of natural ventilation systems in a landscaped office.

Assoc. Professor of Architecture and Env. Health, Enugu State University of Science and Tech.,Enugu. And

HEATING LOAD PREDICTIONS USING THE STATIC NEURAL NETWORKS METHOD. S.Sholahudin 1, Hwataik Han 2*

EVALUATION OF THE THERMAL PERFORMANCE OF FIVE REFRIGERATED VANS

Performance evaluation of an actual building airconditioning

Energy Consumption Measurement of Energy-saving Buildings and Analysis of Simulation Example

Thermal comfort study of residents in Mlaten housing Semarang, Indonesia

Energy-saving Potential Study on Telecommunication Base Station Free Cooling With a Thermosyphon Heat Exchanger in China

Validating Fanger's PMV model in a real field study.

Learning Individual Thermal Comfort using Robust Locally Weighted Regression with Adaptive Bandwidth

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

Facade Design for Super High- Rise Building in Subtropic Region in China

Thermal Comfort & Green Buildings. Dr. Ommid Saberi. "Green Retrofit Conference. WSP Environment & Energy (Middle East)

Energy Performance And Long-Term Evaluation Of Internal Thermal Comfort Of An Office Building With Different Kinds Of Glazing Systems And Window Sizes

Postprint.

A Case Study of the Climate Factor on Thermal Comfort for Hostel Occupants in Universiti Sains Malaysia (USM), Penang, Malaysia

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

INDOOR CLIMATE IN AIR- SUPPORTED STRUCTURE

Transcription:

Impacts of Indoor Temperature and Velocity on Human Physiology in Hot Summer and Cold Winter Climate in China Hong Liu 1, Baizhan Li 1, Liang Chen 1, Lu Chen 1, Jing Wu 1, Jie Zheng 1, Wenjie Li 1, Runming Yao 2 ¹key laboratory of the three gorges reservoir region s eco-environment, ministry of education, China The Faculty of Urban Construction and Environmental Engineering, Chongqing University, China ²Department of Construction Management and Engineering, University of Reading, UK Corresponding email: baizhanli@cqu.edu.cn ABSTRACT The impacts of indoor thermal environment on body physiology have been carried on for four years (2003-2007) in laboratory in Chongqing, a typical city located in hot-summer and cold-winter region in China. Experimental objectives used are healthy university students. The range of indoor air temperature in summer is 25 C - 37.5 C.The objectives physiological changes (Motor nerve Conduction Velocity, Sensory nerve Conduction Velocity, Skin Temperature etc.) under different temperatures and ventilations have been tested. The results show that the effect of air temperature on skin temperature is significant; Skin temperature has a linear and positive correlation with MCV and SCV; Air temperature has a significant effect and a positive correlation with MCV and SCV when indoor air temperature are not too high (25 C - 32 C); In this temperature range, mechanical ventilation can significantly improve the thermal comfort sensation. However, increasing indoor air movement has a little effect on MCV and SCV when indoor air temperature is above skin temperature (34 C - 37.5 C). Such experiments can provide basic data to establish the standard of acceptable indoor thermal environment for hot-summer and cold-winter region in China. Keywords: thermal comfort, indoor thermal environment, human body physiology, Motor nerve Conduction Velocity, Sensory nerve Conduction Velocity INTRODUCTION Buildings are designed to suit the climate in which they are located and the functions for which they are intended. There is a unique relationship between an individual, the

environment and the building he or she inhabits. Everyday experiences tell us that there are a host of factors which are relevant to this concept. Air and surface temperatures, humidity, air movement have an important role. A deficiency in one of the physical factors can spoil the balance of the environment. The physical environment can enhance one s work but an unsatisfactory environment can hinder work output. As building service engineering and building environmental control systems become more complex and expensive, cost justification becomes a greater issue for decision makers. Factors such as poor lighting, both natural and artificial, poorly maintained or designed air conditioning, and poor spatial layouts are all likely to affect performance at work. The variations in thermal comfort and well being were influenced by temperature changes. The indoor thermal environment will directly influence human physical and psychological health, sense of comfort, as well as human s well being [ 1, 2]. Professor Fanger published the famous thermal equations based on experimental data [ 3]. He created the currently widely-used indexes: Predicted Mean Vote (PMV) and the Predicted Percentage of Dissatisfaction (PPD) to assess thermal comfort, based on the human body thermal equivalence equation [4]. The thermal comfort standard recommended by ASHRAE55-2004 [ 5] and ISO7730 [ 6 ] are widely used in the world to measure thermal comfort based on Fanger equations. However, more and more researches show that the PMV-PPD index obtained through experiment in Laboratory in the 1970s can not be suitably applied to all the countries and regions, especially for the free running buildings [ 7, 8,9,10,11 ]. The indoor environment of the hot-summer and cold-winter region is very much different from those experimental conditions in Professor Fanger s air-conditioned Laboratory. The suitability of applying Fanger s result as an international design standard into different local building conditions is now argued by experts. The impact of indoor thermal environment on human physiology has been carried on for four years (2003-2007) in Laboratory in Chongqing, a typical city located in hot-summer region in China. Experimental objectives used are healthy university students. The range of indoor air temperature in summer is 25 C - 37.5 C.The objectives physiological changes (Motor nerve Conduction Velocity, Sensory nerve Conduction Velocity, Skin Temperature etc.) under different temperatures and ventilations have been tested [12,13,14,15 ]. The results show that the effect of air temperature on skin temperature is significant; Skin temperature has a linear and positive correlation with MCV and SCV; Air temperature has a significant effect and a positive correlation with MCV and SCV when indoor air temperature are not too high (25 C - 32 C); In this temperature range, mechanical ventilation can significantly improve the thermal comfort sensation. However, increasing indoor air movement has a little effect on MCV and SCV when indoor air temperature is above skin temperature (34 C - 37.5 C).

METHODOLOGY The impacts of indoor thermal environment on body physiology have been carried on in Laboratory in the region of the hot-summer and cold-winter in China. The parameters of physiology including Motor nerve Conduction Velocity, Sensory nerve Conduction Velocity, Skin Temperature etc, have been selected. The impacts of indoor temperature and velocity on human physiology have been measured and analyzed. The human nerve system consists of trillions of neurons, which have converted to functions to recognize, conduct and analyze information of other cells and environmental information. Nerve system is the quickest responding to heat among all parts of human body. For example, sensory cells receive the stimulus from the climate in a hot environment, and then conduct it to the human brain to cause a feeling of hot or cold. Consequently, nerve system is a main physiological system which has a directly [ 16 ]. influence on the reception and process of information of heat in the environment As far as the human nerve system is concerned, the most frequent and direct parameter is nerve conduction velocity, which is calculated along certain nerve phase, meaning the fastest (both sensory and motion) velocity of neuraxis [ 16 ]. When the electricity stimulates nerve, the impulse is conducted by motor, sensor or mixed nerve. In consideration to convenience and feasibility, the experiment chooses the right-hand median nerve as the stimulated nerve, as Fig.1 shows. The median nerve sensing fiber is mainly distributed in the hand palm side and hand outside skin. The experiment applies the surface stimulation by electrode to test. The stimulated parts and electrodes are located, as Fig.2 shows. Fig.1 Test of median nerve motor conduction. Fig.2 Stimulation of median nerve sensory conduction. Skin temperature is an important physical indicator that reflects the effect on human body by surrounding climate condition and outside body condition (subjects activities and clothes). In normal case, the skin temperature of human body varies between 15 42 C. The skin temperature on any point of body surface depends on local balance between the heat streams that flowing from central to this point of skin and the

heat radiation from there to outside surroundings. Since skin temperature is physical indicator that reflects the compact on human body by surrounding climate condition, it is easy to be affected by the surrounding conditions, which is a sensitive indicator. Hanada s research found that different part on human body has different feeling on warmness [ 13 ]. The body parts as hest, the upper arm and curs are easy to feel cold, while the cold stimulation is most sensitive when the upper arm, forearm, curs and thigh are feeling together. Considering the practical condition, a normal experiment can measure skin temperature of 3 to 10 points to reflect the average skin temperature of the whole body. In the experiments, 6-point method has been used. Skin temperature also affects nerve conduction velocity, which is the most important physical factor that affects conduction velocity. When skin temperature varies between 25 35 C, the decrease of nerve conduction velocity displays the linear relation, namely each 1 C raise of skin temperature results in 2 3m/s increase of conduction velocity. Generally, when skin temperature is higher than 30 C, temperature effect will be little. Therefore, the experiments focused on analysis of nerve conduction velocity, skin temperature and relationship between skin temperature and nerve conduction velocity in the different thermal environmental conditions. Because the experiments relate to measurement of thermal environment physics parameters and the human physiological parameters, the measuring instruments are grouped into two terms: Environmental parameters and Physical parameters measuring instruments. There are Copper-Constantan Thermocouple to measure outdoor and indoor air temperatures, Multifunctional Intelligent Data Acquisition Instrument for checking and measurement, Indoor Air Quality Tester to measure indoor air relative humidity, Portable Hot Wire Anemometer to measure indoor air velocity; Twelve-Channel Electrocardiograph ECG-9103P and Multifunctional Intelligent Environmental Data Acquisition Instrument, MEB-9104 to measure nerve conduction velocity MCV and SCV, Digital Electroencephalogram System EEG-8200 Human Skin Impedance Tester is used to measure skin impedance, Infrared Thermometer to measure skin temperature. All the testing apparatus have been debugged and adjusted. The testing apparatus and instruments have very high precision. Experts have invited to adjust instruments after installation. Inside the room, 30 thermocouples have been averagely distributed and settled at the height of 1.7m from the floor to monitor the distribution of the air temperature in the whole laboratory. The temperature of ceiling, floor, window, wall etc is measured directly by infrared temperature measuring instruments. The causal measuring points are located at 4 places, which are when the subject is away from the floor at 4 heights: 0.1m, 0.6m and 1.1m, which refer to the three body parts when the subject is sitting: feet, belly and head, and 0.5m, which refers to the lying gesture of the subject.

The experiments measure the subjects physical parameters include EEG, MCV, SCV, ECG, skin temperature, skin resistance, heart beat rate, blood pressure, body temperature. These experiments include two extreme environments in winter and summer from July 2003 to Feb. 2007. Time Winter Summer Summer (High-temperature indoor environment) Table 1 Experiment parameters Experiment parameters Indoor air temperature: Indoor air temperature: (13.2±1.5) C (13.2±1.5) C Wind speed near human body: Wind speed near human body: (0.17±0.2)m/s (0.35±0.2)m/s Comparative indoor air Comparative indoor air humidity: humidity: (80.9±4.2)% (80.9±4.2)% Indoor air temperature: Indoor air temperature: (32.4±0.7) C (24.2±0.7) C Wind speed near human body: Wind speed near human body: (0.10±0.02)m/s (0.35±0.2)m/s Comparative indoor air Comparative indoor air humidity: humidity: (73.6±7.4)% (44.2±5.3)% Indoor air temperature: Indoor air temperature: (37.3±0.6) C (37.3±0.8) C Wind speed near human body: Wind speed near human body: (0.10±0.02)m/s (0.47±0.02)m/s Comparative indoor air Comparative indoor air humidity: humidity: (65.4±7.2)% (63.8±6.7)% RESULTS Analysis of the winter measurements results The experiments in the winter mainly measure the influence of air temperature and draught on nerve conduction velocity. From the Fig. 3, it can be observed that the longer the mechanical ventilation is, the more MCV is obviously decreasing. During the whole process, the MCV can be divided into 3 stages. The first stage is from no-draught to 5 mines time of mechanical ventilation, and the MCV has a sudden drop, for the human body is affected suddenly by draught under cold thermal environment, which leads to the bigger heat loss. In the second stage from 5 mines to 20 mines time of mechanical ventilation, the MCV is still decreasing, but with slower speed compared with the first stage. Although the human body heat loss is affected, the human body can automatically moderate its temperature under some environmental parameters. Thus the lowering of MCV caused by draught is controlled. In the third stage after 20 mines time of mechanical ventilation, The MCV change rates are increasing compared with the second stage, The longer the time of draught that subjects suffered, the more MCV decreases rapidly The thermal environments have a bigger influence on MCV.

Fig.3 The impacts of draught on MCV in winter The time of draught blow is negatively correlated to MCV and SCV. The regression equations are y=29.253e -0.062x, y=47.968e-0.0621x respective for MCV and SCV, and correlation coefficients are R2=0.9932 and R2=0.9867 respective. Fig.4 The impact of draught on Skin temperature in winter Fig. 4 shows that there is an obvious decrease trend for skin temperature with the strong draught. And a sudden decline emerges from no-draught to draught. When draught duration is 5min, the decline of skin temperature decreases about 5 C. With the whole testing period, the skin temperature reduces 10 C with the final value of 15 C. There is an obvious effect of draught in winter on skin temperature.

Analysis of the summer measurements results The impacts of air temperature and velocity on the nerve conduction velocity and skin temperature in summer have be measured and assessed similar in summer and in winter. The MCV and SCV have downtrend with the time of ventilation. Fig. 5 shows there is a short suspension of SCV downtrend between 15min and 20min after ventilated. That means the subjects have had a corresponding physiological response to the stimulation made by ventilation during this period. For example vasoconstriction or increase metabolic heat production and reduce heat exchange with the outside to inhibit skin temperature falls, thus inhibiting nerve conduction velocity decline. Subsequently, the cooling capacity of the environment over the body heat production capacity, and the skin temperature further decreases and SCV has further reduced. Comparing to the experiment, the MCV and SCV downtrend in summer with ventilation are far little obvious than that in winter with draught. The subjects skin temperatures with MCV and SCV have linear correlation. Fig.5 The impacts of ventilation on SCV in summer Analysis of extremely high temperature (in summer) measurements results The summer of 2006 in Chongqing has suffered the rare high-temperature and dry conditions for the last 100 years. Outdoor air temperature above 40 C lasts for many ten days. The disastrous weather has provided a valuable opportunity for the experiment for us and gain a number of extremely high-temperature environments indoor physiological data. The nerve conduction velocity has no significant difference for the environment condition. The ventilation could not affect the value of MCV and SCV in extremely high temperature environments. In the extremely high temperature environments, the outside air temperature is higher than the skin temperature; evaporation heat is the only way to dispel heat for the human being, so that the cooling effect of heat dispelled by convection would be ineffective when air flows. Comparing the average value of MCV

and SCV in normal conditions with the average value of MCV and SCV in extremely high temperature in summer, the value of MCV and SCV under the extremely high temperature is higher. That means the higher the air temperature is, the faster the subjects nerve conduction velocities are. The subjects would be prone to fatigue and be adverse to human health. The heat stress will increase the body's physiological load of the organizations and organs. DISCUSSION The impacts of indoor environments on human s physiology and thermal comfort in the regions of hot in summer and cold in winter is very representative and has important practical significance. In this paper, the human physiological parameters, which are affected by environmental factors change obviously (e.g. MCV, SCV, skin temperature,etc.) have been selected and measured in the region of hot-summer and cold-winter in China. The impacts of thermal environments, indoor temperature, draught and ventilation on Human Physiology have been assessed. The results show that MCV and SCV decline obviously with the time of draught in the winter. The skin temperature corresponding to the MCV and SCV show a linear correlation. The higher the indoor temperature is, the higher the value of MCV and SCV are. The MCV and SCV in free-running room with high air temperature are higher than that in air condition environment. The impacts of draught on MCV and SCV in winter are much bigger than the impacts of ventilation in summer. The effect of air temperature on skin temperature is significant; Skin temperature has a linear and positive correlation with MCV and SCV; Air temperature has a significant effect and a positive correlation with MCV and SCV when indoor air temperature are not too high (25 C - 32 C); In this temperature range, mechanical ventilation can significantly improve the thermal comfort sensation. However, increasing indoor air movement has a little effect on MCV and SCV when indoor air temperature is above skin temperature (34 C - 37.5 C). Draught has to be carefully avoided in the winter in order to achieve a comfort thermal environment. Such experiments can provide basic data to establish the standard of acceptable indoor thermal environment for hot-summer and cold-winter region in China. ACKNOWLEDGEMENT The authors would like to give our thanks to Miss. Jiaolin Wang, Mr. Zhenxing Jin, Mr. Lei Chen, Mr. Xinfeng Pan for their vigorous help during the experiment. Also thank all subjects who involved in the laboratory test. The author gratefully acknowledges the support of K.C.Wong education foundation, Hong Kong.

REFERENCES 1. Berglund, L.G., 1979, Thermal Acceptability, ASHRAE Transactions, ASHRAE Atlanta, USA, p825-834 2. Alison G.Kwok. Thermal Comfort in Tropical Classrooms. ASHRAE TRANSACTIONS, 1998,104(part 1B):1031-1047 3. Fanger PO. 1967, Calculation of thermal comfort equation [J]. ASHARE Trans.1967,73(2):5-6 4. Fanger, P.O. 1970, Thermal Comfort, Copenhargen, Danish Technical Press 5. ASHRAE Standard 55-2004, Thermal environment conditions for human occupancy. American Society of Heating, Refrigerating and Air-conditioning Engineers,Ins. Atlanta, GA303 6. ISO. 1984, International Standard 7730, Moderate Environments: Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort. Geneva, International Organization for Standardization, 1984 7. Runming Yao, 1997, Indoor Climate and Thermal Comfort, PhD thesis, Chongqing University, Chongqing, China 8. Michael A. Humphreys. Field Studies of Thermal Comfort Compared and Applied. Building Services Engineer.1976, (44):5-2 9. Michael A.Humphreys, J.Jergus Nicol, Understanding the Adaptive Approach to Thermal Comfort, ASHRAE TRANSACTIONS, 1998,104(part 1B):991-1004 10. M E Fountain. Laboratory studies of the effect of air movement on thermal comfort: A comparison and discussion of methods. ASHRAE Trans, 1991,97(1):22-23 11. B Jones, et al. The effect of air velocity on thermal comfort at moderate activity levels. ASHRAE Trans, 1986,92(2B):24-26 12. Mingzhi Luo, 2004, The research of impact of air flow speed on human body s physiological index and thermal comfort in summer, Thesis of master s degree, Chongqing University, China 13. Jing Wu, 2005 The research of relationship of indoor air flow speed to human body s comfort and physiological stress, Thesis of master s degree, Chongqing University, China 14. Lu Chen, 2006, The research of relationship of indoor thermal environment to human body s thermal comfort and health in hot-summer and cold-winter region, Thesis of master s degree, Chongqing University, China 15. Liang Chen, 2006, Research on the Influence of Indoor Thermal Environment on Body Physiology and Thermal Comfort Thesis of master s degree, Chongqing University, China 16. Lu Zhu Nani etc, 2000, Nerve Sensory Conduction, People s publish houses, 198-243