ITEM 460 REINFORCED CONCRETE PIPE Description. This Item shall govern for the furnishing of reinforced concrete pipe.

Similar documents
ITEM 464 REINFORCED CONCRETE PIPE

INDEX FOR SPECIFICATIONS FOR JACKING CULVERTS THROUGH EMBANKMENTS SCOPE... 2

***************************************************************************************************************

REINFORCED CONCRETE CULVERT STORM DRAIN AND SEWER PIPE FIELD SECTION 1026

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

G. Shop drawing of wall with all dimensions, details, and finishes. Drawings must include post foundations.

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

SECTION UTILITY MANHOLES AND STRUCTURES

SECTION STORM DRAIN

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

INDUSTRIAL PIPE FITTINGS, LLC

SECTION PIPE & PIPE FITTINGS PART 1 GENERAL

DIVISION 31 EARTHWORK 2006 Edition, Published January 1, 2006; Division Revision Date: January 31, 2012

SECTION STORM DRAINAGE AND STORMWATER MANAGEMENT

***************************************************************************************************************

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation

CONSTRUCTION STANDARDS SECTION CS 3 TRENCH FOUNDATION, BEDDING AND BACKFILL

SECTION FACILITY SANITARY SEWERS

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section DUCTILE IRON PIPE AND FITTINGS

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

SECTION GRAVITY IRRIGATION PIPELINES RUBBER GASKETED REINFORCED CONCRETE PIPE (RGRCP)

SECTION A1 EXCAVATION AND BACKFILL GENERAL

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

of GENERAL. A. Description

SECTION REINFORCING STEEL

SECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS

SECTION FLEXIBLE PAVING

SECTION CAST-IN-PLACE CONCRETE

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

STANDARD SPECIFICATIONS SECTION BORING AND JACKING. A. Section includes requirements for boring and jacking casing pipe.

June 2007

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

PIPE BURSTING GRAVITY SEWER MAINS WITH HDPE PIPE

DUCTILE IRON PIPE AND FITTINGS

SDR26 material is to be used as a minimum on all U-M projects.

BAYFILTER SPECIFICATIONS

This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems.

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

SECTION 2200 PAVING CITY OF BLUE SPRINGS, MISSOURI CONSTRUCTION SPECIFICATIONS

Description. This work shall consist of furnishing materials and placement of modular block wall constructed in accordance with

SEWER FORCE MAIN HDPE PIPE

SECTION 501 GRAVITY SEWERS. U. No pipe length used shall be less than 5 feet.

SECTION CONCRETE. B. ACI 318 Building Code Requirements for Structural Concrete and Commentary

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

UNI-BELL PVC PIPE ASSOCIATION UNI-B-15-10

ULTRA-HIGH STRENGTH SHEAR KEY GROUT

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

DIVISION 33 - UTILITIES SECTION UTILITY PIPE BORING AND JACKING DIVISION 33 UTILITIES SECTION UTILITY PIPE BORING AND JACKING

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

Daytona Beach Pier Building Renovation Jun 2010

FOR PROJECTS INITIATED Page -1- AFTER FEBRUARY 1, 2010 REVISION 13 ITEM 360 CONCRETE PAVEMENT

Section 401. PIPE CULVERTS

SECTION STRUCTURAL PRECAST CONCRETE

CHAPTER 6. Sanitary Sewer

INDEX FOR SPECIFICATIONS FOR REMOVING CULVERTS AND PLACING CULVERTS SCOPE... 1

SUGGESTED MANHOLE FRAME SEALING SPECIFICATION (Rehabilitation)

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

ITEM 6 CONCRETE CURBS, GUTTERS, AND SIDEWALKS

PERMEABLE INTERLOCKING PAVERS

SECTION FOUNDATION DRAINAGE

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

Bi-Directional Static Load Testing of Drilled Shafts

B. Subsurface data is available from the Owner. Contractor is urged to carefully analyze the site conditions.

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

1. B16.1 Cast Iron Pipe Flanges and Flanged Fittings, Class C 111 Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings

CW 3615 RIPRAP TABLE OF CONTENTS

Design Data 4. Jacking Concrete Pipe

SECTION DUCTILE IRON FITTINGS. A. This section includes materials, installation, and testing of ductile iron fittings 48 inches and smaller.

A. Submittal Procedures: See Article 13 of the General Conditions.

STANDARD SPECIFICATIONS SECTION JACKED CASING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION TRENCHING & BACKFILLING

STANDARD CONSTRUCTION SPECIFICATIONS

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

SECTION 803 SEWER MANHOLES

SITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

Drainage structure refers to manholes, catch basins, leaching basins, inlets and drop inlets. Drainage structures are designated as follows.

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

SPECIAL SPECIFICATION 3504 Septic Tank System

1. Cast-in-place concrete is specified in Section

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course.

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

Construction Specification for Utility Adjustments

San Antonio Water System Standard Specifications for Construction ITEM NO. 850 SANITARY SEWER STRUCTURES

SEGMENTAL BLOCK RETAINING WALLS. Comply with Division 1 - General Provisions and Covenants, as well as the following:

San Antonio Water System Standard Specifications for Construction ITEM NO. 852 SANITARY SEWER MANHOLES

SECTION LAYING AND JOINTING BURIED PIPELINES

WHAT IS PRECAST/PRESTRESSED CONCRETE?

CITY OF LETHBRIDGE SECTION Construction Specifications SIDEWALK CONSTRUCTION PAGE 1 of 5

Transcription:

AFTER MARCH 1, 2012 ITEM 460 REINFORCED CONCRETE PIPE 460.1 Description. This Item shall govern for the furnishing of reinforced concrete pipe. 460.2 Materials. A. Except as modified herein, materials, manufacture and design of pipe shall conform to ASTM C76, Class III, for circular pipe, ASTM C506 for arch pipe or ASTM C507 for elliptical pipe. All pipe shall be machine made or cast by a process which will provide for uniform placement of the concrete in the form and compaction by mechanical devices which will assure a dense concrete. Concrete shall be mixed in a central batch plant or other approved batching facility from which the quality and uniformity of the concrete can be assured. Transit mixed concrete will not be acceptable for use in precast concrete pipe. In the manufacture of concrete pipe, the supplier has the option of using Portland cement or Portland cement plus fly ash, as defined herein. Cement plus fly ash shall be composed of Portland cement and 20-30 percent fly ash, by absolute volume. Fly ash shall be Class C, conforming to the requirements of ASTM C618 "Fly Ash and Raw or Calcined Natural Pozzolan for Use as a Mineral Admixture in Portland Cement Concrete". Fly ash shall have a minimum CaO content of 20 percent. Pipe Wye and Tee fittings shall be of the same class as the adjacent joint of pipe. Use the bell end of branch openings on Wye and Tee fittings. Unless otherwise shown on the plans, not more than two holes may be placed in the top section of the pipe for lifting and placing. The holes may be cast, cut, or drilled in the wall of the pipe. The holes shall not exceed 3 inches in diameter at the inside surface of the pipe wall. Not more than one longitudinal wire or two circumferential wires may be cut per layer of reinforcing steel when locating lift holes in the pipe wall. All lifting holes shall be sealed to the satisfaction of the Engineer. Tapered lifting plugs shall be used, and sealed externally and internally with an acceptable cement grout. Additionally, lifting plugs shall not protrude from the pipe greater than one-half of an inch. Variations in diameter, size, shape, wall thickness, reinforcement placing, laying length, and permissible underrun of length shall be

Page -2- AFTER MARCH 1, 2012 in accordance with the applicable ASTM Standard for each type of pipe as referred to previously. Pipe shall be free from fractures, all cracks and surface roughness. The ends of the pipe shall be normal to the walls and centerline of the pipe. Pipe shall be cured in accordance with the applicable ASTM Standard for each type of pipe as referred to herein. The following information shall be clearly marked on each section of pipe: 1. The class and ASTM or D-Load of Pipe. 2. The date of manufacture. 3. The name or trademark of the manufacturer and plant location. 4. Designated Manufacturer s Certifying Stamp. 5. One end of each elliptical section of pipe shall be clearly marked on the inside and outside to show the location of the top and bottom of pipe. 5. Clearly mark Pipe to be used for jacking and boring (when applicable). 6. Pipe meeting sulfate-resistant concrete plan requirements (when applicable). Marking shall be indented on the pipe section or painted thereon with waterproof paint. Pipe shall be subject to rejection for failure to conform to any of the specification requirements. Individual sections of the pipe may be rejected because of any of the following: 1. Fractures or cracks passing through the shell/wall of pipe with exception of a single crack that does not exceed the depth of the joint. 2. Defects that indicate imperfect proportioning, mixing and molding. 3. Surface defects indicating honeycombed or open texture. 4. Damaged ends, when such damage would prevent making a satisfactory joint. 5. Any continuous crack having a surface width of 0.01 inch or more and extending for a length of 12 inches or more.

Page -3- AFTER MARCH 1, 2012 6. The painting of pipe shall not be allowed prior to delivery on the project. 460.3 Submittals. Submit certification from the manufacturer that the pipe has been tested and meets the requirements of this Item. The joint material data sheets shall be submitted for approval, by the Design Engineer. 460.4 Joint Material. Unless otherwise specified, the Contractor shall supply the joints using the Rubber Gaskets. Joints using Rubber Gaskets shall conform to ASTM C443. This type of joint shall be applied using lubricants of flax soap or equal. Mineral lubricants are not permitted. The design engineer shall approve a substitution or equal for the rubber gasket joint. 460.5 Construction Methods Unless otherwise specified, the following method shall govern: Jointing Rubber Gasket Pipe: Lay pipe section in trench to true alignment and grade. Exceptional care shall be taken in placing pipe and making field joints. Avoid bumping the pipe in the trench. Place rubber gasket on dry spigot end of pipe. Properly lubricate spigot, with rubber gasket in place, with specified lubricants. Do not twist, roll, cut, crimp or otherwise injure gaskets or force them out of position during closure of joints. Pull or push the pipe home for closure of the joint. Correct joint rebound before backfilling the pipe. Remove foreign matter or dirt from pipe and keep clean during and after laying. Install R.C.P. in accordance with Item 430 Construction of Underground Utilities, and all related drawings/plans. 460.6 Quality Assurance. Concrete pipe 54 inches and smaller in diameter shall be tested in accordance with ASTM C497 using the method outlined by part 4. "External Load Crushing Strength Test by the Three-Edge Bearing Method". The pipe shall be tested at a frequency of three pipe joints for each 100 joints cast, for each pipe size. Concrete pipe 60 inches and larger shall also be tested in accordance with ASTM C497 using the method outlined by Part 6. "Core Strength Test". However, where the manufacture of the pipe is witnessed by the Engineer, tests using concrete cylinders in accordance with ASTM C39 "Test Method for Compressive Strength of Cylindrical Concrete Specimens", shall be acceptable. All test specimens and testing shall be done by the producer of the concrete pipe.

Page -4- AFTER MARCH 1, 2012 Pipe previously approved and stamped by the Texas Department of Transportation (TxDOT) or by the designated fabricator/manufacturer certifying stamp of the reinforced concrete pipe fabrication plant that has been approved by TxDOT in accordance with DMS-7310 Reinforced Concrete Pipe Fabrication and Plant Qualification stating: Certifies Specification Compliance will be accepted by all laboratories and by Harris County. For pipes that are stamped by the manufacturer as stated above, copies of test results (D-loads and compressive strengths) shall be submitted to the Engineer. 1. Random Inspection and Testing. Harris County reserves the right to inspect, sample, and test reinforced concrete pipe at any time to ensure compliance with this Item. The pipe manufacturing plant shall provide facilities, equipment, and access to allow for inspection regarding: the quality of materials, the process for manufacturing, and the finished pipe at the plant; in addition to the inspection that is done of the finished pipe at the site before and during the installation. 460.7 Measurement & Payment. Gravity pipelines (R.C.P.) shall be measured by the linear foot of pipe actually laid, at finished grade, along pipe of size and at depth installed, in accordance with Item 430 Construction of Underground Utilities. Measure depth at manholes, at intervals not to exceed 50 feet between manholes, and at breaks in profile of natural ground from flow line of pipe to natural ground surface over center of pipe. Payment for gravity pipeline, furnished, installed and measured as stated shall be at the contract unit price bid for the size, type, (and depth, if shown on the proposal) measured under their respective bid line codes. If the depth of cut is not shown on the proposal, no consideration shall be made for depth at which the pipe is installed. Pipe installed by tunneling shall be paid for in accordance with Item 431 Jacking, Boring and Tunneling Pipe or Item 432 Tunnel Construction. No separate payment shall be made for ordinary bedding and select backfill, unless so indicated on the bid form. No separate payment shall be made for hauling and storing suitable excavated trench material for other uses or for disposal of excess or unsuitable materials. No separate payment shall be made for any bedding and backfill installed in accordance with these Standard Specifications and the drawings. Well Pointing shall be measured and paid for in accordance with the Item 436 Well Pointing. There are line code(s), description(s), and unit(s) for this Item.

Page -5- AFTER MARCH 1, 2012 NOTE: This Item requires other Standard Specifications Item 430 Construction of Underground Utilities Item 431 Jacking, Boring or Tunneling Pipe Item 432 Tunnel Construction Item 436 Well Pointing END OF ITEM 460