Commercial Plans Application Checklist

Similar documents
4. Number of drawings required: ( ) Locations of nearest streets

Pikes Peak REGIONAL Building Department

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

BUILDING CODES & DESIGN CRITERIA

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL

Commercial Remodel Permit

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

2014 Commercial Plan Submittal Checklist

CODE COMPLIANCE PLAN REVIEW PROCEDURES

PLAN SUBMITTAL REQUIREMENTS - ARCHITECTURAL

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

COUNTY OF RIVERSIDE BUILDING AND SAFETY DEPARTMENT PHOTOVOLTAIC PERMITTING GUIDELINES

RESIDENTIAL BUILDING PERMIT PROCEDURES

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main

Permit Requirements: Building Codes: The City of Clanton has adopted the following codes which are enforced by the Building Department:

A/E Design Deliverable Checklist

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

UNIVERSITY OF ARIZONA CONSTRUCTION AND RENOVATION PERMITTING PROCEDURE ADOPTED: JULY 2011

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

COMMERCIAL PLANS SUBMITTAL CHECKLIST For Commercial and Multi-family (3 or more units) Building Permit Applications

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

Building Permit Application Instructions INFORMATION REQUIRED FOR ISSUANCE OF A BUILDING PERMIT

City of Donnelly. Permit Application Information and Instructions

The Building Codes A.R.E. Building Design and Construction Exam Prep

A/E Design Deliverable Checklist

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

City of Jacksonville Development Guide Building Permits

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

Building Codes in Effect: 2010 California Building, Residential, Fire, Energy and Electrical Codes, including Article 690.

RESIDENTIAL BUILDING REQUIREMENTS

Applying the Building Code During Design

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

CITY OF GLASGOW BUILDING PERMIT APPLICATION 126 E. Public Square Glasgow, KY Phone: (270) Fax: (270)

COMMUNITY DEVELOPMENT

Individual Truss Marking Is it a Building Code Requirement?

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

Building Codes and Ordinances ARC 227

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

START RIGHT A G U I D E T O L + I S E R V I C E S

Application for Commercial Plan Review and Building Permit. Address:

PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

CHAPTER 29 PLUMBING SYSTEMS

HOW TO OBTAIN A BUILDING PERMIT

The designer shall also submit additional information required by the University as described and underlined below.

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

NY State Unified Solar Permit

CONTACT INFORMATION. PV System will require a separate Electrical Permit.

Plan Review Instructions

A homeowners/applicants guide to understanding and making application for a building permit.

BUILDING PERMIT APPLICATION

GENERAL PLAN REVIEW REQUIREMENTS

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004

STATE UNIVERSITY CONSTRUCTION FUND

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

PIKES PEAK REGIONAL BUILDING DEPARTMENT

Dave Harper, Building Official (509) Susan Davis, Administrative Secretary (509)

BUILDING PERMIT BASICS

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

Questions and Answers about Madison Crescent and Noise Issues

Minnesota Health Care Engineers Association

RESIDENTIAL BUILDING PLAN REQUIREMENTS

2009 IBC Section 1024 Approved Luminous Egress Path Markings

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

Commercial Permit Process

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Uniform Statewide Building Code Independent Inspections. Guidelines and Procedures

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

Residential Building Permit Application

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Detached Garage Construction Information

FCIA Webinar Gypsum Wall Patching

GENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

Office Hours: 9 a.m. to 5 p.m. Kristal Bachman Community Development Administrator. Jaclynn Workman Inspections Coordinator

BUILDING PERMIT APPLICATION

APPLICATION FOR SOLAR PERMIT

Application Requirements for obtaining a Building Permit

RESPONSIBILITIES IN THE DESIGN PROCESS INVOLVING METAL PLATE CONNECTED WOOD TRUSSES

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

District of Barriere A GUIDE TO BUILDING PERMITS

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

General Residential Code Requirements

PERMIT APPLICATION REQUIREMENTS INTERIOR RENOVATIONS/BUILD OUTS CODES USED: ADOPTED FLORIDA BUILDING CODE & NEC

E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e

Building Guide. Colorado Chapter of the International Code Council

Structural Redesign Gravity System

Chapter 1: Application and Administration

SCHEDULE B RESIDENTIAL BUILDING FEES

Residential Accessory Structure Application Packet (Carport, Shed, Garage, Pool)

The following materials and documents are required in order for you to obtain a Building Permit:

2015 IBC Exit Systems

2012 IBC Exit Systems

DESIGN DEVELOPMENT PHASE

Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc.

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

Transcription:

Botetourt County, Virginia Development Services Construction Compliance 5 West Main Street, Suite 100 Fincastle, Virginia 24090 Phone: (540) 473-8248 Fax: (540) 473-2018 www.botetourtva.gov Commercial Plans Application Checklist This document lists the minimum building code information required for commercial project plan review. While providing all of the information listed below does not guarantee plan approval, it will expedite the review process and increase the likelihood of plan approval on first submission. Please review the list and provide the necessary material with your application. Documents Required... 2 For All Applications... 2 Where applicable... 3 Information Required on Documents... 4 General... 4 Structural... 7 Electrical... 9 Frequently Asked Questions (FAQ)... 12 General Building Code Information... 14 The Botetourt County Development Services Office coordinates commercial permit applications. Its staff is happy to answer questions concerning permit requirements and processing. Call (540) 473-8248 to schedule a pre-permitting meeting, or to request a forms and information packet. The Botetourt County Development Services Office reviews commercial plans for compliance with the VUSBC. For questions regarding the commercial plan review process, the building code, or to arrange a pre-application plans review, call (540) 473-8248. Procedural information and forms may be downloaded from the County website s Commercial Permitting page: http://www.botetourtva.gov/business/permitting.php Revised September 2013 page 1 of 15

Documents Required For All Commercial Permit Applications The following is only a guide and may not be required for all projects. Consult the Construction Compliance Office if you have questions. completed Occupancy, Zoning, Building Permit Application form and applicable fees. for Construction Compliance Dept: 1 set of signed and sealed complete construction plans and 1 digital (CD-rom) copy. Signed and sealed plans will be returned to owner/ contractor/ or design professional (including a site plan) for Planning & Zoning Dept: 2 site plans (if new construction, expansion, or change of use) copy of State contractor s license copy of contractor s Botetourt County business license or Town business license (depending on whether job is located within an incorporated town limit) copy of current deed (if new ownership as of January 1) Revised September 2013 page 2 of 15

Where applicable In certain circumstances, the following will be required: Town permit soils report (see VUSBC 1802) sprinkler and pre-fabricated structures shop drawings, signed and sealed asbestos inspection report for the remodeling or repair of existing building (if built prior to 01/01/85) documentation of VDOT Highway Entrance Permit (if adding or changing a VDOT entrance) documentation of water/sewer construction and/or connection approval: Well and Septic...letter from the Health Department (473-8240) Private/Public...receipt from the County or private company statement of Special Inspections (see VUSBC 1704.1.1) MSDS sheets (if hazardous materials will be stored in the building or space) listing the materials with their hazard classifications (see IBC, Tables 307.7(1) and 307.7(2)) foundation certification Certification from a registered design professional stating that the foundation has been designed according to actual loads supplied by the fabricator for prefabricated structures (wood trusses, metal buildings, etc.). This certification may be on the plans or in a letter sealed by the registered design professional. Water and Sewer plans for approval and associated fees. Erosion and Sediment plans for approval, Land Disturbing permit application, and associated fees. Site plans for approval and associated fees. Revised September 2013 page 3 of 15

Information Required on Documents General The following is only a guide and may not be required for all projects. Consult the Construction Compliance Office if you have questions. a Virginia Professional seal (with signature and date) on the construction documents per The Code of Virginia ( 54.1-402) for the following uses: assembly, educational, institutional, hotel/motel and high hazard; mercantile and business uses when the area of work exceeds 5,000 square feet; storage and factory/industrial uses when the area of work exceeds 15,000 square feet. Provide the name, occupation, address and telephone number of the person who is responsible for the design if a registered design professional s seal is not present on the construction documents per The Code of Virginia ( 54.1-402). a code analysis summary containing the following: governing codes construction type (IBC Chapter 6) allowable area / actual area, including calculations supporting area increases (VUSBC Table 503, Sections 505, 506, 507 and 508) allowable height / actual height, including calculations supporting height increases (IBC Table 503, Sections 504 and 508) use and occupancy group classification (VUSBC Chapter 3) design occupant load per building (VUSBC 1004.1) (VUSBC Chapter 3) the method of treating mixed uses: non-separated mixed use, separated mixed use (provide ratio sum), or separate buildings minimum plumbing fixtures required / provided (IPC 403) fire resistive ratings of each building element and corresponding openings, (IBC Table 715.3) according to: construction type (IBC Tables 601 and 602) distance to property line (IBC Tables 601 and 602) occupancy separations (IBC Tables 302.1.1 and 302.3.2) corridors (IBC Table 1016.1) Revised September 2013 page 4 of 15

Identify the following on scaled, dimensioned floor and ceiling plans or on a scaled dimensioned code analysis diagram: Buildings on the same lot or fire areas (IBC Section 704.3 and Section 503.1) each tenant space if the project is in a shopping center or other use with multiple tenants (VUSBC Chapter 4) the use of each room or space (VUSBC Table 1004.1.1 and IBC Table 302.1.1) square footage and design occupant load per room. Give actual design number and tabular number by VUSBC Table 1004.1.1, if applicable. existing, demolition, and proposed construction areas fire-resistive rated construction including fire walls, fire partitions, fire barriers, smoke barriers, shaft enclosures, horizontal assemblies, fire separation assemblies, incidental use areas and smoke partitions (VUSBC Chapter 7) sprinkler, fire alarm and detection systems, and fire suppression equipment locations (VUSBC Chapter 9) fire extinguishing cabinet locations (VUSBC Chapter 9) egress capacity, proposed egress and egress direction at every exit (VUSBC Chapter 10) exit signage and emergency lighting locations (IBC Section 1011 and Section 1006) a dimensioned site layout plan that includes: established street grades, proposed finished grades, and ground floor elevations the slopes of paving on the accessible route overall dimensions of all buildings on the site footprints of all construction to be demolished, to remain, or to be constructed the distance from the building footprint(s) to property lines and any adjacent buildings drawn in accordance with an accurate boundary line survey accessible parking Revised September 2013 page 5 of 15

a door schedule that includes: door size hardware type (locks, latches, handles, closers, panic and fire exit hardware, operating devices, access control systems) door fire rating expressed in hours, if rated glazing type building sections locating floor/ceiling and roof/ceiling assemblies with details, design numbers and specifications typical wall sections and partition types All fire rated walls must be labeled as to type (fire partition, fire barrier, smoke barrier, shaft enclosure, horizontal assembly, fire separation assembly, fire wall, smoke partition), provided with design numbers and specifications (U.L., Gypsum Association, etc.), drawn full height with cross sections of all fire rated assemblies including all materials used in the assembly, support and termination details. stair and ramp sections through penetration fire stopping systems with details, design numbers and specifications If project is an alteration, identify all walls and other structural framing that will be affected by the alteration. If framing or foundation systems will be altered, provide complete foundation and framing plans with the design loads listed. Framing plans should provide beam, joist, rafter and truss sizes and layouts. Foundation plans should show footing depths, sizes and design bearing capacity. interior wall and finish requirements (IBC Section 803, Table 803.5) Revised September 2013 page 6 of 15

Information Required on Documents Structural 1. Per VUSBC part 1 Construction Code section 109.3 Engineering Details and IBC 1603 Construction Documents, provide on the plans: General floor live load(s) including concentrated load(s) roof live load(s) roof dead load(s) rain load including the ds and dh used for calculation per IBC 1611 when water accumulation is possible Roof Snow Load flat roof snow load, psf or sloped roof snow load, psf for slopes over 5 degrees snow exposure factor, Ce snow load importance factor, Is thermal factor, Ct drift loads per 1608.7 (section 7.7 of ASCE 7) if applicable Wind Load per IBC 1609 provide the basic wind speed use category and Importance factor the exposure group the applicable internal pressure coefficient effective wind loads/pressures for the main wind force resisting system and components and cladding (windward, leeward, uplift, component and cladding pressures) Earthquake Design Data per IBC 1615 use category and Importance factor site class design spectral responses Sds and Sd1 (calculated showing the Ss, S1, Fa and Fv used) the seismic design category the analysis procedure used Revised September 2013 page 7 of 15

any structural irregularities listed calculations for Cs and W including the R and Ie used for calculation the seismic base shear the basic seismic force resisting system used per column 1 of table 1617.6.2 Revised September 2013 page 8 of 15

Information Required on Documents Electrical General Differentiate new work from existing work Drawings need to be at least 1/8 scale or larger Indicate locations of all wet and hazardous locations All drawings need to be neat and legible and all of the same size Make sure all spaces and rooms are labeled as to their use Title Block Project name and address Designer's name and address Designer s telephone number Designer's seal and signature or master card number and signature Show page numbers Service Details Show location of meter and CT cabinet on floor plans Show location of service equipment Size service conductors, raceways; specify raceway type Indicate AIC rating of service equipment and all panelboards Show all fuse and breaker sizes Indicate amperage, voltage and phase of service equipment Grounding details for services Show grounding electrode system and details Size all grounding conductors Revised September 2013 page 9 of 15

Panelboards Provide panelboard schedule with connected loads and breaker sizes Indicate if panelboards are main lug or main breaker type Indicate AIC rating Indicate panelboards, voltage, phase, rating in amps and name of panel Feeders Show wire size and type Show conduit size and type Show feeder loads Indicate size of equipment grounding conductor Branch Circuit Details Designate all branch circuits serving power, lighting and equipment Show all wiring sizes, conduit sizes and number of conductors Transformers Indicate size in KVA Indicate primary and secondary voltages Show over current protection Show location of transformer on drawing Indicate size of grounding electrode conductor Disconnects and starters Show location of all disconnects and starter on plans Show size and type; fused or nonfused Indicate fuse size Show location of all electrical equipment on plans Show loads of equipment on panel schedules Egress and Exit lights Show location of all exit and egress lights on plans Indicate lighting circuit that they are supplied from Show breaker lock on panel schedule if using the exception in Article 700 Revised September 2013 page 10 of 15

Demand load Summary Sheet Show connected loads of new and existing electrical system Indicate NEC demand loads per Article 220 Indicate if demand loads are being calculated from the standard or optional methods Revised September 2013 page 11 of 15

Frequently Asked Questions (FAQ) Submittals: Documents for the commercial building permit application must be submitted to the County Administrator s Office. Thereafter, questions should be addressed to the Office of the Building Official regarding the status of the building permit. Plan review turn around time: Goal: plans review within 14 business days. Once the plan review has been completed, comments will be compiled in a letter and mailed to the permit applicant and architect. For scheduling purposes, allow 4 to 6 weeks from application to permit issuance. Building plan and site plan reviews proceed simultaneously, however, the building permit can not be issued until Planning and Zoning approvals have been received. Structural design criteria specific to Botetourt County: Ground Snow Load: 30 psf Basic Wind Speed: 90 mph 3 second gust Frost Depth: 24 minimum Specifications and calculations: Specifications or calculations are not required to be submitted with the permit application unless they contain building code related information not included on the plans. The Commercial Plans Application Checklist contains a section listing what information is required on the documents. If you are unsure, submit the specifications. If errors or concerns are discovered during the structural review, calculations may be requested at that time. Mechanical, Electrical, Plumbing (MEP) plans: Full Mechanical, Electrical and Plumbing plans must be submitted with the building permit application for review. Fire protection systems: Alarms, sprinklers, hood suppression, standpipes Plans for fire protection systems can be submitted separately from the building permit application. However, please provide enough lead time for review of these drawings prior to construction. Revised September 2013 page 12 of 15

Current code: The 2006 Virginia Uniform Statewide Building Code Buildings not requiring permits: Detached accessory structures used as tool and storage sheds, playhouses or similar uses, provided the floor area does not exceed 150 ft 2 and the structures are not accessory to a Group F or H occupancy. (VUSBC 108.2, #2) Revised September 2013 page 13 of 15

General Building Code Information The Virginia Uniform Statewide Building Code (VUSBC) is enforced in all jurisdictions in The Commonwealth of Virginia. The most recent edition is VUSBC 2006, which became effective May 1, 2008. Parts 1 and 2 of the VUSBC, (Virginia amendments) contain administrative provisions that replace corresponding chapters of the ICC codes. In addition, they contain technical amendments to the ICC codes. Jurisdictions may not make further amendments to the VUSBC. ICC codes adopted by VUSBC : 2006 ICC International Building Code 2006 ICC International Plumbing Code 2006 ICC International Mechanical Code 2006 ICC International Fuel Gas Code 2006 ICC International Energy Conservation Code 2006 ICC International Residential Code 2006 ICC International Existing Buildings Code 2006 ICC International Fire Code 2005 National Electrical Code (NFPA 70) Standards: See Chapter 35 of the ICC International Building Code for various design standards. VUSBC adopted the following standards in lieu those that are referenced in Chapter 35 of the IBC: ASCE 7-05, ASME A17.1-2000, and ASTM E329-02. Accessibility: VUSBC adopted the accessibility provisions in Chapter 11 of the 2006 ICC International Building Code, which further references ICC/ANSI A117.1-03. Energy Code: VUSBC adopted the energy code requirements in Chapter 13 of the 2006 ICC International Building Code, which further references the 2006 ICC International Energy Conservation Code. Revised September 2013 page 14 of 15

Life Safety Code: The NFPA 101 Life Safety Code was not adopted by the VUSBC. The 2006 ICC International Building Code is the Life Safety Code enforced in Virginia. However, hospitals, nursing homes, assisted living facilities, etc. may be subject to NFPA 101 provisions if they are state or federally funded. Current and past editions of the VUSBC (Virginia amendments) can be downloaded from: http://www.vbcoa.org/. 2006 VUSBC, Part 1: The Construction Code can be accessed directly from: http://www.vbcoa.org/2006%20usbc%20codes/virginia%20construction%20code.pdf 2006 VUSBC, Part 2: The Rehabilitation Code can be accessed directly from: http://www.vbcoa.org/2006%20usbc%20codes/virginia%20rehabilitation%20code.pdf The ICC International Codes and their supplements are available on CD in all Botetourt County Libraries or may be purchased directly from the International Code Council (ICC) online store at http://www.iccsafe.org/e/prodcat.html?catid=i-codes. The Botetourt County Municipal Code can be accessed from the County website: http://www.botetourt.org/municipal_code/php Revised September 2013 page 15 of 15