COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

Similar documents
COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Online Gas Analyzer / Monitor

UniGas Hand-held combustion gas analyzer with 4 sensors

testo 340 Speed, power & precision in industrial combustion analysis.

testo 330 Flue gas analysis with increased convenience and safety

Highly efficient flue gas analyzer

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Compact flue gas analyser: testo 300 M-I

Just a few clicks away from a heating system

GreenLine 6000 GreenLine 8000

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

Using the PPM2 Portable Trace Moisture Transmitter

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

Fine particle measuring system

REFERENCE MEASURING INSTRUMENT

New Measurement Engineering For Monitoring Emissions In Industry

testo 350. For emission testing and combustion analysis. Portable Emission Analyzer

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

PORTABLE FLUE GAS ANALYZER

testo 350 M testo 350 XL

GAS 3050P NDIR FLUE GAS

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

Instruction Manual Dräger MSI EM200-s

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Combustion Laboratory Unit C492

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

EUROλYZER STx. Flue Gas Analyzer. BlueLine

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

CH88 In Situ Flue Gas Oxygen Transmitter

ICAC MARAMA Portable Emission Analyzers

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

testo 175-T1 testo 175-T2 1 channel temperature logger with internal sensor 2 channel temperature logger with internal sensor/external probe socket

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

HOBO Plug Load Logger (UX ) Manual

TVOC Heated FID VE 7

The new 4-sensor flue gas analyzer for emission measurement in industry

Flue gas analyzer. We measure it. testo 310 Flue gas analysis the easy way. Robust design for daily use. Battery lifetime up to 10 hours

The Leader in Performance Indoor Air Quality Measurements

Data Logging Solutions from Lascar Electronics

MRU Instruments, Inc. Houston, Texas Tel.: (844) (Toll Free)

8 stream capability with dual mode (H 2 S & total Sulphur)

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

The new testo 330 LL visualizes measurement data graphically

Humidity/temperature measuring instrument

testo 350-S/-XL testo 350 S/XL, flexible flue gas measuring system Additional information at Control unit Analysis box

Multifunction HVAC and IAQ Meter

Controls and Software CHORE-TRONICS 2 Controls

Flue gas analysis brilliantly easy: testo 350

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

Controls and Software CHORE-TRONICS 2 Controls

Dräger MSI Variox-2 Combustion Gas Analysis

TWIN LASER PARTICLE COUNTER

EuroFID Total Hydrocarbon Analyzer

Gas concentrations in the air

Flue gas analyser. We measure it. testo 327 The special class entry instrument. Simple menu structure

Macro 900 WQS. Macro 900 Meter completely waterproof, simple to use, rugged for field use

Control Solutions for Farm Dairies

PORTABLE HARDNESS TESTING

Fpollutant-free zero air for analytical

Fast-action and userfriendly. exchange by the user on site

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

The new flue gas analyzer testo 330 LL visualizes measurement data graphically

Ultrasonic Load Monitoring

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

Flue gas analyzer for industry

S700 Modular Gas Analyzer. Measures more than 60 different gases

Explore the future of osmometry. Multi-Sample Micro-Osmometer

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

The. universal 3D Inspection reference. advanced 3D measurement software & solutions

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

ZK830 COUNTING SCALE. Precision counting scale for industrial use ZK830 COUNTING SCALE

Multi-function VAC measuring instrument

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

FLUXUS F/G601 and F/G608

GRAVIMAX Blenders & DOSIMAX Feeders

PORTABLE ULTRASONIC HARDNESS TESTER

NovaWAVE. A new category of Automated Microwave Digestion

Instruction Manual. for. gskin U-Value Kit


Carbon / Sulfur Analyzers

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Blenders Precision Blending. world of innovation

Hydrant Pressure Monitoring Five of the most popular uses of Telog s HPR-31, hydrant pressure recorder, are:

Gas sensors can be changed quickly and easily by the user on site

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Transcription:

High /H comp NO NOx Portable Flue Gas Monitoring LANM 4 NO H S SO C X H Y www.lancom4.com

LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In excess of two thousand Lancom analysers are in use today, in a wide range of applications - all subjected to very different measurement conditions. Features Monitoring of up 17 measurement parameters Up to 9 gas measurements in a single instrument High quality colour display Multiple Language support USB Communications Support Weighs only 6 kg (13 lbs) Robust, industrial design Wake and Sleep, semi-continuous operation mode Selectable log file names Data acquisition & analysis software Simple field upgrade Meets ASTM D-65 with Dry Sampler probe Benefits One instrument to meet all requirements User selectable Visualise your data with new widescreen display Navigate the menu in English, French, German, Italian, Spanish, Portuguese and Chinese (other languages available on request) Simple interface to PC and data transfer - supports USB memory sticks Easily carried around plant For daily use in the harshest plant environments For periodic unattended operation Keep track of data records Capture, manipulate, and report data on your PC Add features and options as and when required Report generation to recognised standards SO C X H Y H Comp O O NO High NO X The world s most versatile portable flue gas analyser H S

Convenient catchpot - visible and accessible The side-mounted catchpot is both fully protected and highly visible for rapid checking, removal and emptying. Clip-in filters - visible and quick to change The chemical and particulate filters are mounted on the side of the instrument. Visible inspection and replacement is straightforward. The rugged case design protects all components from damage. High Colour Display New high resolution colour display supports a multilingual, simple user interface. Flue gas & ambient temperature The analyser takes a direct thermocouple temperature measurement of the flue gas, and has an ambient temperature sensor fitted. These are required for making accurate combustion efficiency calculations. Straightforward servicing Service is simple via the menu driven software. Self diagnostic checks are run continuously on calibration status and battery life. Setup and measure within minutes Simply switch on, an automatic zero calibration is performed by the analyser. Plug in the sample probe and take real-time gas readings in a matter of minutes. Easy access sensors Each sensor is installed in its own unique position. Replacing a sensor is a simple process and takes only a few minutes. Unclip the side panel for access, swap the sensor and re-calibrate. Direct Measurement capability The infrared sensor used in the Lancom 4 enables direct measurement of in flue gas. The combination of this sensor with the measurement capability offered by the flow probe, can give quantitative information on greenhouse gas emission. Long life rechargeable battery Rechargeable batteries give up to 8 hours continuous operation. A power supply cable is is supplied for battery recharging. Data Logging Internal data logging makes it easy to record measured gas concentration. After a measurement run, simply download the data to a USB memory stick to transfer to PC. The 64MB of available memory means an almost unlimited number of log records can be stored. Selectable data log files allow measurements to be identified by their location. Automatic Sensor Protection Auto Purge of sensors on system shutdown clears system of corrosive flue gases. overrange protection Automatically purges low sensor and switches to high range measuring mode, if high levels of are encountered.

How the analyser works 1 6 3 4 5 7 11 8 H C X H Y H S NO 10 L O NO SO 9 Key 1. Sample Gas Inlet. Catchpot for condensate 3. Particulate Filter 4. Pressure Sensor 5. Air Input 6. Sample Pump 7. Expansion Chamber 8. Chemical Filter 9. Purge Pump 10. Exhaust 11. Flow Probe Inlet Integral sample conditioning The gas sample is drawn into the analyser via a sample probe and hose connected to the input connection on the side panel of the analyser. The sample enters the water catchpot where residual water is removed. The sample gas is then passed through a 0.1 micron particulate filter. Filtering out damaging chemicals - prolonging sensor life The sample gas is routed to the sensor manifolds, after removing flow and pressure variations. To ensure that the and C X H Y sensors are not poisoned by other gases the sample gas is fed through a chemical filter prior to being routed to these sensors. This action ensures prolongs sensor life and improves measurement accuracy. Automatic Sensor protection To protect the sensor from excessive levels of (normally levels >000ppm), the system automatically switches to the high range sensor (up to 4000ppm). The low sensor is then automatically purged using a dedicated pump which blows ambient air to protect the sensor, ensuring rapid recovery time and maximum sensor life. View showing measurement sensors Sensor accuracy and longevity The Lancom 4 performs a zero calibration every time it is switched on, and purges the sensors with ambient air before switching off. This ensures maximum accuracy and sensor longevity.

Selecting the analyser The following features are standard on all instruments: Standard Sample Probe USB Interface Data Logging RS 3 or RS 4 Serial Communications Interface The user selects which gases (between 3 and 9) and then the options that are required for their application. (See list below) Options Draft Measurement Flow Measurement Smoke Measurement Range of Sample Probes Insight Data Acquisition Software system Analogue outputs Wake and Sleep facility (Semi-continuous monitoring) Language display options Carry case External Printer Description Internal stack pressure in hpa or inches water gauge Flue gas velocity, flow rate and mass emissions rate Readings of Smoke spot number (Bacharach Smoke scale) Smoke, Flow, DrySampler* and High Temperature Simple-to-use Windows reporting software Eight 4-0 ma current loops, independently configurable Takes gas measurement at user defined intervals (see below) English, French, German, Italian, Spanish, Portuguese & Chinese Holds Analyser, Battery charger, Sample probe plus accessories Hard copy of measurements *US Patent No. 678767 Sample Probes A wide range of sample probes suitable for specific application and measurement requirements are available. Request Information ref. PDS 198 DrySampler Probe High Temperature Probe Standard Probe SO C X H Semi-continuous Monitoring Y Wake and Sleep monitoring takes gas measurements O O at user defined intervals. This is achieved by cyclically sampling and logging gas concentrations over a period of time. (alternate wake and sleep phases). User settings include wakeup interval, number of samples between wakeup, sample interval and first wakeup. NO High Smoke Probe NO X Flow Probe H Comp leading the way in portable flue gas monitoring H S

Measurement Specifications Sensor Minimum Range Maximum Range # Accuracy % of range Resolution O 0 to 5% v/v 0 to 30% v/v ±1% 0.1% v/v (low) 0 to 100 ppm 0 to 6000 ppm ±%* 0.1 ppm (H compensated) 0 to 100 ppm 0 to 4000 ppm ±%* 0.1 ppm (high) 0 to 4000 ppm 0 to 10 % ±%* 0.1 ppm SO 0 to 100 ppm 0 to 4000 ppm ±%* 0.1 ppm NO 0 to 100 ppm 0 to 5000 ppm ±%* 0.1 ppm NO 0 to 100 ppm 0 to 1000 ppm ±%* 0.1 ppm H S 0 to 00 ppm 0 to 1000 ppm ±%* 0.1 ppm ** 0-5% v/v ±%* 0.1% v/v Hydrocarbons (C x H y ) 0 to 4% v/v (Calibrated as methane) 0.1% v/v Flue Gas/Ambient Temperature Measured Draft ± 50 hpa / 0 Water Gauge *** Flow (velocity) 1 to 50 m/s *Calibration per ASTM D-65 or LAND factory procedure **True measurement if sensor fitted (calculated if not) ***Reduced to ± 5 hpa / 10 Water Gauge when used with flow probe # Operating at maximum possible range may affect sensor life and accuracy Combustion & Environmental calculations Combustion efficiency Loss Excess Air (where no sensor fitted) Oxygen normalisation Total NO X Wet or dry basis Automatic conversions - ppm, mg/m 3, lb/mmbtu, ng/j Sensor Types Lancom analysers use the following sensors in order to measure gas concentration levels. Sensor Type Gas Electrochemical,, High, H compensated, O, NO, NO, SO and H S Infrared Pellistor/Catalytic C X H Y C X H Y O O NO SO capable of monitoring up to 9 different gases High NO X H, Comp H S

Combustion & Environmental Monitoring Suitable for most applications where the flue gas temperature is below 600 C / 111 F. Suitable for applications where the sample gas temperature is between 600 C and 1400 C / 111 F and 55 F. For measuring smoke density simultaneously with flue gas analysis. For measuring the sample gas flow rate, and calculating mass emissions levels. Proven revolutionary design to dry the flue gas at the sample point. Independently verified by the UK National Physical Laboratory, Report No. QE1/0/104. Selection of probe length options Range of flexible hose lengths Integral flue gas temperature thermocouple (except HT probe) Standard replaceable particulate filter (Standard and DrySampler probes only) Probe Length Options (m) Length Options (ft) Max. Flue Gas Temp. Options/Accessories Standard Probe 0.3, 1.0, 1.5,.0, 3.00 0.9, 3.3, 5, 6.6, 9.8 600 C / 111 F 3 m or 10 m / 10 ft or 33 ft hose available High Temp. Probe 0.5, 1.0, 1.5.0 1.6, 3.3, 4.9, 6.6 1400 C / 55 F 3 m / 10 ft hose available Smoke Probe 0.3, 0.75, 1.0 1,.4, 3. 600 C / 111 F 3 m / 10 ft hose, Filter Papers, Bacharach Chart and In-line Flowmeter Flow Probe 0.7, 1.,., 3.0.3, 3.9, 7., 9.8 600 C / 111 F 3 m or 10 m / 10 ft or 33 ft hose DrySampler 0.3, 1.0, 1.5,.0, 3.0 0.9, 3.3, 5, 6.6, 9.8 600 C / 111 F 3 m or 10 m / 10 Probe ft or 33 ft hose available Insight is a Windows based data acquisition software program, used for logging measurement data directly from a LANM portable gas analyzer. Data can be analyzed either as it is collected in real time, or during review of logged data. A range of statistical and graphical tools allow the user to perform measurements, manipulate, report, present and print data. Trace Graph Frequency Distribution Specifications - LANM 4 Display: Keypad: Indicators: Power Supply Ambient Temperature: Flue Gas Temperature: Case: Dimensions: Weight: Standard Accessories: Options: Full function colour LCD with backlight, wide QVGA display Tactile membrane (integral with display) function keys and cursors LED type for ON (Power), Stand-by, Charge, Battery, Fault 95-65 V a.c. ±10%, 50-60 Hz, 30 Watts. Battery, rechargeable lead-acid (internal). Typical 8 hour operation, dependent on options fitted -5 C to 45 C (+3 F to 113 F) Max. 600 C (111 F) standard, Max. 1400 C (55 F) with high temperature probe Medium density blended polyethylene 453 x 10 x 45 mm (17.8 x 4.7 x 9.6 inches) 6 kg (13 lb) Integral water catchpot and filters,battery Charger supply, Probe handle, Hose and Probe pipe (Lengths listed below under options), Data logging Min of 3 to max 9 gases in total, from a selection of 9 gases Probe length options - 0.3, 1.0, 1.5,.0, 3.0m/1, 3.3, 5, 6.5, 10ft Alternative probes available - Refer to Data Sheet Reference PDS198 for details Hose length options - 3 m/10 ft or 10 m/33 ft Draft Measurement Flow Measurement, probe length options - 0.7, 1.,., 3.0 m/.3, 3.9, 7., 9.8 ft Smoke Measurement, probe length options - 0.3, 0.75, 1.0 m/1,.4, 3.3 ft Insight Data Acquisition Software system - Refer to Data Sheet Reference PDS05 for details Analogue outputs (Eight 4-0 ma current loops, independently configurable) Wake and Sleep facility (Semi-continuous monitoring) Carry case External Printer Language display options - English, French, German, Italian, Spanish, Portuguese & Chinese, others available Other related data sheets LANM Portable Flue Gas Analyzers Insight Data Acquisition & Analysis Software SAMPLE PROBES The LANM range of portable flue gas analyzers feature a full choice of sample probes suitable for a wide range of applications. Standard Sample Probe High Temperature Sample Probe Smoke Probe Flow Probe DrySampler Probe All LANM sample probes feature: Features Real-time data display, capture and storage Range of display formats Integrated statistical analysis functions Range of calculations User definable alarms with event monitoring User-programmable averaging algorithms Export data to Microsoft Excel or text file Simple to use Windows-based software Range of user-configurable sample triggers Local or remote operation Ideal for USEPA CTM-034 reporting A simple tool for on-site record keeping, analysis and reporting Lancom Sample Probes - further information Insight Data Acquisition System - further information Land Instruments International Ltd Dronfield S18 1DJ England Email: land.combustion@ametek.co.uk www.landinst.com Tel: +44 (0) 146 417691 Fax: +44 (0) 146 410585 Combustion and Environmental Monitoring AMETEK Land, Inc. 150 Freeport Rd Pittsburgh, PA 1538 U.S.A. Email: combsales@ametek.com www.ametek-land.com Tel: +1 (41) 86 4444 Fax: +1 (41) 86 4460 For a full list of international offices, please visit www.landinst.com or www.ametek-land.com www.lancom4.com PROCESS & ANALYTICAL INSTRUMENTS Applies in the UK Applies in the USA Copyright 011-013 Land Instruments International Continuous product development may make it necessary to change details without notice. PDS4/0413