Waterproofing and Types of Drains

Similar documents
A Design Review of Waterproofing Codes

LOT GRADING GUIDELINES

DESIGN OF SEWER SYSTEMS

LOT GRADING GUIDELINES

Section X - Miscellaneous

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

PLATON FOUNDATION WRAP

SECTION FOUNTAINS

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

Guidance Document Podium Decks & Buried Roofs

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Foundation/Site Work Code Requirements

Below Ground Waterproofing

STRUCTURAL ASSESSMENT OBSERVATION REPORT

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

STRUCTURAL CONDITION ASSESSMENT

Background Basement Thermal Behavior

Industrial Sealers & Coatings

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

FLOOR AND AREA DRAINS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

PART 5 WATER SYSTEMS

FLUID APPLIED WATERPROOFING

Floor Care Solutions. Cost Effective, High Performance and Easy to Use Concrete Treatments

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

BTM BT2K 600. Areas of Use

Appendix J: Storm Conveyance Design Parameters

In much of America, soils don t act in

BUILDING CODES Presented by CORUM ENGINEERING

Multiline. ACO SYSTEMS and SOLUTIONS Pvt. Ltd. Polymer Concrete Drain System. Your Partner in Water Management Solutions

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Tile on Existing. Viewpoint

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

4 EXTREME FOUNDATION PANELS

1.02 RELATED WORK: Refer to the following sections for related work:

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

DESIGN STANDARDS. Division 02 Existing Conditions- Site Work. General

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

10 EXTREME BASEMENT PANELS

SAMPLE. Slab On Ground Construction. Carpentry - Residential Construction. Product Code: 5597

Architectural Guidelines

Drainage with system SELF structural elements

AVM System 500. Aussie Membrane 500

by Jason P. Wilen, AIA, CDT, RRO testing the integrity of a roof or waterproofing membrane. But since

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

Waterproofing Products for UNDERGROUND STRUCTURES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

4 EXTREME FOUNDATION PANELS

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

OREGON ROOF CONSULTING - ROOF INSPECTION FORM

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

Sealing a Crawlspace. Close the vents and let a heavy-duty vapor barrier keep moisture, mold and radon out of the living space BY LARRY JANESKY

HydraPressed Slabs. Yorkstone Tan. Wherefunctionmeetsstyle

SECTION FACILITY SANITARY SEWERS

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

SPECIAL SPECIFICATION 3504 Septic Tank System

Pocono Builders Association 2014 Building Awards Environmental/Energy Efficiency

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

PECORA-DECK TRAFFIC COATING SYSTEMS

PRODUCT CATALOG INNOVATION, TECHNOLOGY, CONSTRUCTION CHEMISTRY.

Integral Waterproofing

SECTION CROSS CONNECTION CONTROL AND BACKFLOW PREVENTION

Master Specification SECTION 02621

Encapsulated, Sealed & Closed Crawlspace Installation Manual

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

Mr. Eric Ryffel, Manager October 5, 2015 Sanibel Beach Club 626 Nerita Street Sanibel Island, Florida 33957

METHOD STATEMENT 001 CONCRETE BALCONY WATERPROOFING FOR DIRECT FIXED TILES

WATERPROOFING Flexible Waterproofing with Sika Membrane Technologies

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Property Condition Assessment

BUILDING ENVELOPE PRODUCTS PROVIDING A FULL BUILDING ENVELOPE SYSTEM. Control Moisture Movement with Our Patented Technology

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

Cures, Sealers Densifiers & Crystal Technology Ultimate / Proven Concrete Protection

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

LEVEL TWO NUMBERS AND TITLES. Introductory Information. Bidding Requirements. Contracting Requirements. Facilities and Spaces. Systems and Assemblies

Differences between EnCon Insulated Precast and EIFS

CHECKLIST Inspecting a Garage

Siphonic. Drain System. Engineered Water Solutions for Today s Building Design Needs

PermaroofUK. Frequently asked questions

Construction Inspection Checklists

SPECIFICATION GUIDELINE

Inspection of New One- and Two- Family Dwellings

prospec.com Concrete Repair & Restoration

VILLAGE OF ORLAND PARK, ILLINOIS ADDENDUM NO. 1 REBID # STELLWAGEN FARMHOUSE RESTORATION: PHASE 1 EXTERIOR FOUNDATION

Evaluation, Restoration and Protection of Sandstone Façade on a Historic Building The Boston Building Denver, CO Presenter: Leo Whiteley

CHAPTER VI. -- FOUNDATION REPAIR & DAMP PROOFING TABLE OF CONTENTS

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

StormwaterWise Landscapes: Pervious Surfaces Specifications

PRODUCT GUIDE SPECIFICATION

Drainage and Erosion Control

Schluter -KERDI-DRAIN

ROOF DRAINS TABLE OF CONTENTS

Transcription:

Waterproofing and Types of Drains 4 PVC Downspout Burial w/ Y Fitting for Future Clean-out Yard Drain Box 12 Drain Box 12885 Old Frederick Road Sykesville, MD 21784 Office 410-442-2445 Fax 410-489-4312 www.rhinelandscaping.com - MHIC # 121739

Channel Drains Removed & Replaced Small Basement Drain w/ 4 Wide Channel Drain Tied into Existing Basement Sump Pump Dura-Slope Channel Drain Set in Concrete in Front of Garage Doors 4 Channel Drain Set in Concrete in Driveway Pictured to the right and below is a channel drain installed between existing concrete and new paver pool deck. This drain has decorative top grate

Drain Boxes 18 Drain Box w/ Green Atrium Grate 18 Drain Box w/ Atrium Grate Commercial 30 Drain with cast iron Atrium grate 12 PVC Drain Box Built into Asphalt Driveway 12 PVC Box Drain w/ Easy Clean Containment Off of Driveway 6 Brass Top Drain Set in Natural Stone 6 Brass Top Drain Set in Pavers

Exterior waterproofing with downspouts piped underground and run away from the home. Multiple drain boxes installed to collect water in low lying yard. Rubber liner was placed against the foundation and under the decorative river rock. Rip Rap Drainage Swale Pop-Up Emitter

Flo-Well System Being Installed Sometimes windows are not a good idea. We can close them in, waterproof them, and re-grade away from the home Complex drainage system to alleviate drainage problems between two homes. Notice the 4 pipe grading into the larger 6 main for maximum flow. Existing French Drain Around Foundation Waterproofing Basement Walls

Waterproofing Membranes Information Waterproofing is the combination of materials used to prevent water intrusion into the structural elements of a building or its finished spaces. Its main purpose is to resist hydrostatic pressure exerted by moisture in the liquid state. Waterproofing membranes consist of waterproof plastic, rubber, or coated-fabric materials. The materials are used in a system to prevent the ingress of water into foundations, roofs, walls, basements, buildings, and structures when properly installed. The term dampproofing is often confused with waterproofing, however, dampproofing is a system designed to resist the flow of moisture in a gaseous state i.e. water vapor. Location of Waterproof Membrane Depending on the structure and need, the waterproofing membrane can either be applied to the interior (negative), such as the case with repairs, the exterior (positive), or in places inaccessible by people (blindside). Positive Side Positive waterproofing membranes are applied to the exterior face of a structure. It can be applied above, below, or at grade to surfaces that will get wet due to exposure to weather conditions and the surrounding soil. Positive waterproofing is a critical step in construction because it prevents moisture infiltration and protects structural components, including the concrete and steel. It can also protect the surface from freeze-thaw cycles and corrosive chemicals. When used for below grade surfaces (such as sealing a foundation) it is available as a fluid applied membrane, sheet-membrane, or as hydros clay and vapor barriers. The disadvantage of positive side waterproofing is that it is inaccessible after construction except with costly removal of the topping landscape. Positive side waterproofing should be used alone when the surface will be exposed to corrosive soil, freeze-thaw cycles, and if there will be limitation to the interior humidity. Image Credit: Basement Systems

Negative Side Negative side waterproofing is applied to the interior face of a structure. It keeps water from entering an occupied space and is applied to what is known as the dry face. Negative side waterproofing is primarily used for water holding purposes (prevent water from entering space), but it does not prevent the water from entering the substrate (wall). The materials used for negative waterproofing must be able to withstand hydrostatic pressure. The most commonly used materials are epoxy injections and cementitious coatings. The advantage of negative side waterproofing is that it is accessible after installation for repairs or updates. Negative side waterproofing allows moisture into the substrate which can be seen as an advantage and disadvantage. Moisture promotes active curing of the concrete substrate, but it contributes to the corrosion of the concrete and steel reinforcements from the groundwater and chemicals. This type of membrane does not protect against the effects of the freeze-thaw cycle and can only be used on cemenitious systems. Image Credit: Building Care Solutions

Rhine provides a way to keep water OUT of your home unlike most basement waterproofing companies which invite the water in, collect it and then pump it out. We excavated to the footer Found the crack along the foundation Grinding out the crack and filling with hydraulic cement Pressure washing foundation to find any additional cracks and prepare for waterproofing tar

Covering the foundation in waterproofing tar Installing heavy-duty rubber liner against foundation Installing new foundation French drain Then we fill with clean gravel and cover with fabric Lastly regrade with topsoil to prevent future issues

Interior Basement Waterproofing & New Sump Pump This is what it looks like after cutting and removing concrete and installing the new French drainage system in basement. Close up photo of dimpled drain board. This creates a 1 air space next to the foundation to allow the water into the new French drain. New sump pump and discharge pipe installed in corner of basement. The finished product after the concrete was re-installed.