Passion for timber FORMWORK. pfeifergroup.com

Similar documents
HT 20plus. Formwork timber beams. Facts on formwork timber beams: Contents. Product standard. Wood types. Beam height. Weight.

G.B.M. building equipments PONTEGGI. Parapetti Certifi cati SHUTTERING PANELS AND FORMWORK H20 BEAMS

GLT GIRDER LONGITUDINALLY TENSILETESTED

Formwork panels HT 12/16/24/30plus

PERI PD 8 The cost-effective shoring for slab tables and high loads

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

Technical Guideline for AVI NIRO THERMOKORB

1.1 Dimensions Timber of up to mm thick (KD) can be heat-treated. The maximum thickness varies depending on the type of timber.

Design Methods of Elements from Cross-Laminated Timber Subjected to Flexure

Renovation of Buildings using Steel Technologies (ROBUST)

FINNFOREST GLULAM INDIVIDUALLY DESIGNED WOOD SOLUTIONS

Styrodur C, Environmentally friendly extruded polystyrene free of CFC, HCFC, and HFC filled with air.

MULTIFLEX Girder slab formwork. Assembly Instructions for Standard Application

FLOOR STRUCTURES. Floor structures Building Construction I.

KLH Massivholz GmbH. Publisher and responsible for content: KLH Massivholz GmbH Version: Timber Concrete Composites, Version 01/2017

Sika Tricomer Compression Seals

THE GLULAM Specialists

LVL Product Guide 2.0E LVL 1.5E LVL

ENGINEERED FORMWORK AND SCAFFOLDING SOLUTIONS

UGRA LVL Laminated Veneer Lumber

WoodWisdom-Net Seminar Edinburgh 4-5 April 2017 HCLTP Hybrid Cross Laminated Timber Plates

Evaluation Listing CCMC L Nordic X-Lam

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

AraucoPly panels offer. Versatility Strength with Lighter Weight High Quality Panel Construction. Light Uniform Color and Easy Workability

Precast concrete structures

CH. 9 WOOD CONSTRUCTION

All- Glass Staircase, Notting Hill, London

built build to slabs SLABFORM

Behavior of a multiple spans cable-stayed bridge

Kerto ENGINEERED TO PERFORM

Technical Data for. Headers. and Beams

DICTATOR Lift Shaft System

Product overview:

BILL OF QUANTITIES. Construction and Rehabilitation of wadi Gaza Bridges PAL Funded by Government of Brazil

ACTION OF GLUED STEEL PLATES IN STRENGTHENING OF STRUCTURES

Ask for FSC certified products. Ask for PEFC certified products.

Advance Design of RC Structure Retaining Wall

Lecture Retaining Wall Week 12

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

Seismic Analysis And Design of a Commercial Buildings (G+5)

DESIGN OF WALLS FOR SHEAR

SHOT FIRED DOWEL FLITCH BEAMS

Timber-steel-hybrid beams for multi-storey buildings

Technical Data Sheet. Mass 10 Mass 25 Mass 50 M AT 125. Eurocode Compliant. T E C H N I C A L D A T A S H E E T Mass 10. MU Bridging Compact Bridging

Cross Laminated Timber (CLT)

European Technical Assessment ETA-10/0422 of 08/01/2016

Chapter 3: Torsion. Chapter 4: Shear and Moment Diagram. Chapter 5: Stresses In beams

Very Tall Wooden Buildings with Cross Laminated Timber

EXPERIMENTAL STUDY REGARDING THE BEHAVIOR OF GLUE LAMINATED BEAMS DOUBLE REINFORCED WITH RECTANGULAR METAL PIPES (RMP)

Thermal insulation elements DIN

Demountable Shear Connectors for Sustainable Composite Construction

IZODOM 2000 POLSKA Zduńska Wola, ul. Ceramiczna 2. tel , , tel./fax

Sika KAB combination joint waterbars waterstopping systems

CROS S - L A MINATED TIMBER

Comparative Study of R.C.C and Steel Concrete Composite Structures

GLULAM TIMBER ELEMENTS

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

December 1, 2014 PARTIES INTERESTED IN STRUCTURAL WOOD-BASED PRODUCTS

fischer fixing compass Solid and hollow brick masonry.

NEW HYBRID GLULAM BEAM REINFORCED WITH CFRP AND ULTRA-HIGH-PERFORMANCE CONCRETE

Instructions for installation and use PFEIFER LSV Lifting Loop

* technical applications of rubbers and platics

Bulletins Glulam-Bulletin April 2013

Carbon fibre shear links for structural strengthening

EN DK NA:2007

Cement grouted steel bars in glulam

Construction. Carbon fiber shear links for structural strengthening. System Description. (Template for local translation, only for internal use)

European Technical ETA 06/0238 Assessment of 31/08/2017

Flat Slabs. d 2. A typical flat slab (without drop and column head)

Sabah Shawkat Cabinet of Structural Engineering 2017

Sustainable Lightweight Wood-Strand Panels for Building Construction

HIGH PERFORMANCE REINFORCEMENT PRODUCTS. Product Catalogue.

EVERLAST KWILA/MERBAU GL17S ENGINEERED MAGNA BEAMS & KWILA/MERBAU GL13 ENGINEERED MAGNA POSTS

Reticulated Timber Dome Structural System Using Glulam with a Low Specific Gravity and its Scalability

RB WEIR GATES MODEL GENERAL DESCRIPTION DESIGN CONSTRUCTION

B. Modular House. Feature: Installation Procedure:

Aluminum Beam Gang System

Repairing of timber and fire-damaged structures

SPC recently concluded a partnership with a leading Italian company providing innovative and complete polyethylene pipe systems in 30 countries.

Allround Scaffolding. Propping Technical Brochure. The universal system for everyday and engineered scaffolding solutions

FOLLOW US ON PLEXIGLAS UNDERWATER WINDOWS UNDERWATER WINDOWS. Experience and Enjoy Quality

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

four design methods & beams Allowable Stress Design Limit State Design Allowable Stress Design

Heavy Rib. Page 1 of 6. Expanded Mesh & Metal Products. Key Product Features:

STRUCTURLAM CROSS LAMINATED TIMBER DESIGN GUIDE

MOISTURE CONTENT - STRENGTH RELATIONSHIP FOR LUMBER SUBJECTED TO BENDING *

Hollow Core Slabs in Construction Industry

Analysis and design of cantilever falsework for high rise building. Kartikkumar Prajapati1, Roshni John2

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

Fundamentals for Steel Constructions

Chapter 5: Introduction To Prestressed Concrete Design

Acoustic-Lightboard. Meets highest demands in sound and fire protection. when it matters!

A division of Canam Group

Layher Aluminium Lattice Beams. Information and User Guide. Aluminium Lattice Beam 750 (Product Code 4903XXX)

The Transport Component EUROBLOCK PALLET BLOCK. euroblock.com

MULTIFLEX The flexible girder slab formwork for all ground plans and slab thicknesses up to 1.00 m. Product Brochure

Initial Tests of Kevlar Prestressed Timber Beams

h Installation Manual

Study of Fracture Properties of Cement Stabilized Macadam

LPI 56 Technical Guide

Transcription:

Passion for timber FORMWORK BEAMS pfeifergroup.com

PHILOSOPHY The Pfeifer-Group is developing a new generation of timber formwork beams. After intensive development and test phase we are launching one of the bester timer formwork beams on the market: the PF20plus. Lighter, stronger, safer and more durable! The applications range from the ceiling on wall formwork, bridge and tunnel formwork to work platforms.

FORMWORK BEAMS Features beam ends and protective cap are rounded the entire face side is protected by the cap shock proof high dimensional stability low shrinkage no risk of injury no sticking and no steel brackets necessary to secure the protective cap Features beam ends are rounded the entire face side is protected against climatic influence by a special face side stain compact, light weight shock proof high dimensional stability low shrinkage no risk of injury good mechanical properties of the protective cap at high and low temperatures UV stabilizer to weather fixing of the cap carried out with plugs, therefore the face side is not being weakened

Assembly 200 mm 40 mm 120 mm 40 mm Product range Formwork Beams PF20plus PF20 Length: 190, 245, 250, 265, 275, 290, 300, 330, 360, 390, 450, 490, 590 cm, Special lengths possible up to 11.90 m PF20plus: protection cap possible up to 9 m over 9 m only cut straight PF20: rounding with sealing possible up to 9 m over 9 m only cut straight Black thickness: 27 mm Weight: 4.5 kg/running meters Wood moisture: 12 % +/- 4 % at delivery Package units: 50 or 100 pieces 27 mm Measurement table Example: Given: Ceiling thickness (18 cm) + crossbeam spacing (75 cm) Sought: Yoke beam spacing + support spacing 1 Ceiling thickness: 18 cm 2 Crossbeam spacing: 75 cm 3 Permissible yoke-beam spacing according to table 1 = 2,65 m 4 Select same or next smaller yoke-beam spacing in table 2 = 2,5 m 5 Choose value 2,50 in table 2, choose the value for ceiling thickness (18 cm) and read the permissible support spacing value : 1,36 m 6 Attention: The corresponding bearing capacity of the supports must be verified. Floor thickness (cm) Total load kn/m 2 Table 1 Table 2 Cross-beam spacing (m) Yoke-beam spacing (m) 0,50 0,63 0,67 0,75 1,00 1,25 1,50 1,75 2,00 2,25 2,50 3,00 3,50 Max. distance between cross beams (m) The deflection of the beams is limited to L/500. Live load 1,5 kn/m 2 or 20 % of concrete weight. Max. distance between yoke-beams (m) = max. distance between ceiling support beams 10 4,40 3,63 3,37 3,29 3,17 2,88 2,67 2,46 2,28 2,13 2,01 1,91 1,67 1,43 12 4,92 3,43 3,19 3,12 3,00 2,72 2,53 2,33 2,16 2,02 1,90 1,79 1,49 1,28 14 5,44 3,27 3,04 2,97 2,86 2,60 2,41 2,41 2,05 1,92 1,80 1,62 1,35 1,16 16 5,96 3,14 2,92 2,85 2,74 2,49 2,31 2,12 1,90 1,83 1,64 1,48 1,23 1,05 18 6,48 3,03 2,81 2,75 2,65 2,40 2,22 2,03 1,88 1,70 1,51 1,36 1,13 0,97 20 7,00 2,93 2,72 2,66 2,56 2,32 2,14 1,95 1,80 1,57 1,40 1,2 1,05 0,90 22 7,52 2,84 2,64 2,58 2,48 2,26 2,06 1,88 1,67 1,46 1,30 1,17 0,98 0,84 24 8,04 2,76 2,57 2,51 2,42 2,19 2,00 1,82 1,56 1,37 1,22 1,09 0,91 0,78 26 8,56 2,70 2,50 2,45 2,35 2,14 1,93 1,71 1,47 1,29 1,14 1,03 0,86 0,73 28 9,08 2,63 2,44 2,39 2,30 2,09 1,88 1,62 1,38 1,21 1,08 0,97 0,81 0,69 30 9,66 2,57 2,39 2,34 2,25 2,03 1,82 1,52 1,30 1,14 1,01 0,91 0,76 0,65 35 11,22 2,45 2,27 2,23 2,14 1,89 1,57 1,31 1,12 0,98 0,87 0,78 0,65 0,56 40 12,78 2,35 2,18 2,13 2,04 1,72 1,38 1,15 0,98 0,86 0,77 0,69 0,57 0,49 45 14,34 2,26 2,10 2,04 1,53 1,23 1,02 0,88 0,77 0,68 0,61 0,51 0,44 50 15,90 2,18 2,01 1,94 1,38 1,11 0,92 0,79 0,69 0,61 0,55 0,46 0,40 80 mm Formwork Beams PF20plus PF20 Allowable Values Shear force A support reaction Bending moment Characteristic limit Q = 11 kn A = 22 kn M = 5 knm Lateral force Vk = 23,9 kn Contact resistance Rb,k = 47,8 kn Bending moment Mk = 10,9 knm Rigidity I E I = 450 knm² Crossbeam spacing Monitoring as per M lt. EN13377 DIN V 20000-2 External monitoring by MPA Stuttgart Nr. ÜZ-BWU03-I 14.24.40 Spacing of supports Spacing of yoke beams

facts Capacity & capability The Pfeifer formwork beams are being produced according to the highest quality standard at two European locations. With a production capacity of 9 million running meter, we are one of Europe s leading manufacturers. All formwork beam sizes are continuously in stock for optimized and short notice service for our customers. Quality Our internal quality control system ensures compliance with our high standards of quality. Furthermore, the quality of our production is also continuously monitored by two external organizations: Institute MPA Stuttgart and the Holzforschung Austria Wien. Environment We harvest our timber from sustainable managed forests. The use of wood binds the harmful greenhouse-gas CO₂ long term and thus has a strong emission-reducing effect. Logistics Our products are available in more than 75 countries around the world, and we therefore have a well-established logistical network.

Pfeifer HolDING GmbH Fabrikstraße 54 A-6460 Imst Tel.: +43 5412 6960 0 Fax: +43 5412 6960 200 info@pfeifergroup.com From the heart of Europe into THE whole WORLD Uelzen Sawn timber Single & three-ply panels Lauterbach Schlitz Glued-laminated timber beams Formwork beams HöcHstädt Imst Trhanov Unterbernbach Kundl Shuttering panels Pellets Briquettes Bio power Pallet blocks Sawn & planed timber Single & three-ply panels Glued-laminated timber beams Pellets & briquettes Pallet blocks pfeifergroup.com