Assessment of solar reflectance of roofing assemblies of dwellings in Guayaquil, Ecuador

Similar documents
Ventilative Cooling potential tool

THERMAL PERFORMANCE USING RADIANT BARRIER AND PHASE CHANGE MATERIAL IN ROOFS

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

ENERGY SELF SUFFICIENCY WITH RENEWABLE SOURCES BIOMASS AND WIND IN THE REHABILITATION PROJECTOF AN OLD RURAL BUILDING COMPLEX IN SICILY (ITALY)

Analysis 2: Alternative Thermal Window Design

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Effects of tall building envelope technologies and design strategies on the urban microclimate in hot arid regions

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

An Assessment in the Heat Gain and Loss Through Opaque Elements in Commercial Buildings in Brazil

PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

The effect of shading design and control on building cooling demand

An Evaluation of the Total Energy Consumption of Educational Buildings: Prototype Case Studies in Saudi Arabia

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

Great Ocean Rd Ice Creamery

Attaining Thermal Comfort in. Buildings with Predominantly. Glazed Facades. presented to: ANSYS Boston Regional Conference

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Solar Energy Technologies

Performance-Risk Methodology for the Design of High-Performance Affordable Homes

Modeling and analyzing solar cooling systems in Polysun

EVALUATION OF THE SOLAR INCOME FOR BRAŞOV URBAN AREA

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

Giuseppe Giordano Founder & CEO

A prototype architecture for passive and plus energy building in Estonia

Thermal Comfort Zone for Thai People

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Available online at ScienceDirect. Energy Procedia 48 (2014 )

Cool Roof Case Studies

A CASE STUDY OF A RESIDENTIAL PHOTOVOLTAIC SYSTEM WITH MICROINVERTERS

PCMs in Building America Projects - Roof Retrofit Technology with Use of the PCM Heat Sink

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of

Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre

Solar heating system sizing Solar storage tank size (volume) Solar collector array size (area)

Reflective Roofs. Sustainable Communities Conference Sustainable Surfaces Track March 10, 2009 Dallas, TX. R. Chappell

Introduction to basics of energy efficient building design

Zero Energy Building Example in Estonia. Tõnu Mauring

AIC TECH 2015 Sustainability in Practice Turning Ideas into Reality Jan 16, 2015 FUTURE & NET ZERO BUILDINGS

METHODOLOGY The process starts with a collection of available information, continued by an audit in loco, it is

The use of Simulation Software to Evaluate the Thermal Performance of Buildings in Brazil

THE USE OF COMPUTER SIMULATION TO ESTABLISH ENERGY EFFICIENCY PARAMETERS FOR A BUILDING CODE OF A CITY IN BRAZIL

Passive Houses in South West Europe

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

Energy Efficiency in Kuwait: Past, Current & Future

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

An entire CO 2 neutral region? Transitioning to decentralized energy systems A step-by-step approach

Methods for Improving Energy Performance of Single-family Buildings in Poland s Climatic Conditions

Indoor Thermal Environment in Residential Buildings at Different Micro-Climates in Malaysia

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

Assignment 3 Integrated Energy Design

Efficient utilization of energy sources

INFLUENCE OF HIGH PERFORMANCE FAÇADE ON HEATING/COOLING LOAD IN OFFICE BUILDINGS IN LONDON AND HONGKONG

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

International Journal of Applied Science and Technology Vol. 2 No. 3; March 2012

Charles D. Corbin & Gregor P. Henze

Hot water persons. Map section

Results and Recommendations from Energy Audit of Shageluk. For VEEP Grants Village of Shageluk, Alaska

Developing Solutions for the Environmental Challenges to Deploying PV Plants in Desert Areas

Passiv Haus Institut Dr. Wolfgang Feist PEP Project Information

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Zero Carbon Building Energy Modelling Guidelines. October 31, 2017

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Work Package 2: Performance of naturally ventilated buildings

Green Building Guideline of Jordan

The Importance of Slab Edge & Balcony Thermal Bridges

Comprehensive Energy Audit For Kongiganak Health Clinic

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

Héctor Rubio Plana Gas Natural, SDG S.A. 18th. June 2009

Modeling Energy Performance of Concrete Buildings for LEED-NC Version 2.2: Energy and Atmosphere Credit 1

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

European Cooperation in the field of Scientific and Technical Research. Building Integration of Solar Thermal Systems TU1205 BISTS

Electric Forward Market Report

Available online at ScienceDirect. Energy Procedia 78 (2015 )

High Performance Buildings for Singapore for Better Energy Management. SERIS Solar Energy Research Institute of Singapore

Reducing Peak Energy Demand: The Hidden Benefit of Cool Roofs

through Early Stage Energy Modeling dl

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

Influence of Retro-reflective Material on Public Buildings Energy Consumption in Different Climate Regions

Following CEN Mandate M/480 [1] a comprehensive

Ground-Coupled Heat Pump And Energy Storage

The Mirenda Center for Sports, Spirituality, and Character Development

Application of a cooling tower model for optimizing energy use

2 kw. ak.com. www. Energy report

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

Envelope Optimization

EFFECTS OF SHADING DESIGN OPTIONS ON THERMAL AND DAYLIGHTING PERFORMANCE OF A MODULAR HOUSE IN MELBOURNE

LEED v4 Credit Guidance for Andersen Products LEED for Building Design and Construction: Homes and Multifamily Midrise

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

Available online at ScienceDirect. Procedia Engineering 145 (2016 ) 18 25

Passive house optimization for Southern Italy based on the New Passivhaus Standard

Airspace R-Values. Educational Overview. Revised 12/6/2016

Transcription:

Energy and Sustainability VI 307 Assessment of solar reflectance of roofing assemblies of dwellings in Guayaquil, Ecuador J. Macias 1,2, G. Soriano 2, H. Sanchez 2 & Y. Canchingre 2 1 Instituto Nacional de Eficiencia Energética y Energías Renovables, INER, Ecuador 2 Centro de Energías Renovables y Alternativas, CERA, Escuela Superior Politécnica del Litoral, ESPOL, Ecuador Abstract A study of the impact of solar reflectance of roofing assemblies on energy behaviour of social interest dwellings located in Guayaquil, Ecuador is presented. Values of solar reflectivity were obtained for a typical sample of local roofing materials using the procedure for measuring the solar reflectance of flat or curved roofing assemblies developed by Akabari, which is suitable for assemblies and surface materials with surface irregularities and non-homogeneous colour. This methodology when compared with the standard methodology ASTM E1918 Standard Test Method for Measuring Solar Reflectance of Horizontal and Low- Sloped Surfaces in the Field produces differences of ±0.02 units of reflectance for sample assemblies of homogenous colour and ±0.03 units in sample assemblies of heterogeneous colour. Values in the range of 0.29 to 0.51 were measured from the sample of local materials. The social interest dwelling model follows the guidelines of the Ecuadorian Secretary of Housing. The energy behaviour of the dwelling was modelled using a simulation software compliant with ANSI/ASHRAE 140. Differences of the annual energy consumption in KW-h of the dwelling when using a standard window air conditioning unit are analysed for the range of measured and ideal solar reflectance values. Thermal comfort is studied by a floating simulation to obtain the effect of solar reflectance on maximum interior temperature and relative humidity. Keywords: solar reflectance, roofing assembly, energy consumption, thermal comfort. doi:10.2495/esus150261

308 Energy and Sustainability VI 1 Introduction Performance of building envelope is a significant issue during a building life cycle. Several researchers and engineering practitioners have suggested that solar absorption of envelope surfaces plays an important role, and recommending high reflectance roofs for warm and hot climates due to its potential of energy savings up to 20% due cooling load decrease [1]. Synnefa et al. [2] provide a review which validates high reflectance surfaces as effective means to improve envelope energy performance, and shows that increasing of roof solar reflectance can reduce 18 93% of cooling loads and peak cooling demand HVAC by 11 27%. Additionally, in locations with high solar irradiance (1000 W/m 2 ) and low wind speed conditions, the temperature of a black opaque surface with a solar reflectance (SR = 0.05) of 0.05 could reach around 50 C higher than ambient air temperature. On the other hand, white low reflectance surface (SR = 0.8) the temperature rises about 10 C at the same conditions [2]. Finally, the application of high reflectance roofing compliance credits for international buildings codes such as ASHRAE 90.1 and 90.2, and it is an inexpensive and effective approach to contribute to buildings energy efficiency [3 5]. At the local level, the Ecuadorian government through the Secretaries of Housing aims to develop guidelines for sustainable social interest dwellings through the program SAV-BID [6]. The guidelines propose the use of native improved materials and friendly environmental designs at low cost. A complete energy assessment of the proposed guidelines have not been performed. Guayaquil is Ecuador s largest city with a population of 2 million people and it is located at 2 16 51 South and 79 54 49 West. Guayaquil s weather is tropical with average temperature of 27 C [7]. In consequence, cooling energy demand is relative high and therefore roof reflectance plays a key role in order to reach comfort temperatures in dwellings. The objective of this work is to measure solar reflectance of typical roof assemblies and evaluate how it affects the cooling energy demand for dwellings in Guayaquil. The material s reflectance were calculated using an experimental method developed by Akbari et al. [3] and the performance of a social dwelling model under different roofing conditions was simulated and compared. 2 Methodology Six different roofing materials samples of typical use in Guayaquil were collected. Their experimental solar reflectance (SR) was quantified by Akbari s experimental procedure. Next, these results supported an energy simulation of a typical social interest dwelling. Finally, variations in annual cooling demands, peak cooling rates and hours of discomfort were analysed. There are some experimental methods to calculate spectral solar reflectance on surfaces. Standard ASTM E903 employs a spectrophotometer with an integrating sphere, a method appropriate for laboratory environment and controlled conditions [8]. This procedure requires flat and smooth samples with dimensions of 100 100 mm, with homogeneous colour and composition.

Energy and Sustainability VI 309 Alternatively, standard test method ASTM C1549 utilizes a portable reflectometer adequate for field and laboratory conditions. The portable reflectometer accuracy is within ±0.003 units of the spectrophotometer technique [9]. Reflectometers as spectrometers need homogeneous and smooth surfaces with a minimal sample area requirement of 5 cm 2. It is possible to measure curved surfaces, with radius larger than 5 cm. For field measurements, standard ASTM E1918 is the most appropriate. A precision pyranometer measures irradiance at different conditions. Solar reflectance is determined using a ratio of irradiances. The method is applicable for heterogeneous and irregular surfaces, such as low and high profile tile assemblies [10]. Nevertheless, it presents some difficulties such as mounting assemblies of 10 m 2 at least, and taking measurements on clear sunny conditions without clouds and haze. In addition, Akbari et al. [3] proposed a modification on the procedure of standard ASTM E1918 with the name of E1918A. The procedure E1918A employs samples of 1 m 2 and two reference surfaces (black and white). Akbari determined solar reflectance of 14 clay and concrete tiles samples via E1918, E1918A and E903. The results from procedure E1918A differ from the other standard methods by values of ±0.02 and ±0.03 units of reflectance for homogenous and heterogeneous colour samples respectively. In order to determine solar reflectance of roofing assemblies, procedure E1918A was selected due to its experimental simplicity and low cost. Four different samples representative of roofing assemblies in Guayaquil were characterized. Figure 1 provides a schematic of the experimental setup where the target solar reflectance is calculated with equation (1), where and are known reflectance values of the white and black reference surfaces respectively., and are the values of the reflected irradiance from the white surface, black surface and roofing assembly acquired from the pyranometer as established by Akbari et al. [3]. (1) Figure 1: Schematic for the experimental Akbari method [3].

310 Energy and Sustainability VI Figure 2 shows the tested set of common roofing assemblies. It comprises of samples of red ceramic tile, steel panel, zinc and fiber cement. The values were obtained between June and August 2014, because it is the period with the most uniform solar irradiance in Guayaquil. The impact of variation of solar reflectance was assessed with an energy simulation of a house under Guayaquil s weather using Energy Plus [11]. Table 1 presents climatic conditions of Guayaquil for a typical meteorological year. The weather in Guayaquil could be classified as hot and humid type 1A according to ASHRAE 90.1 definitions. In a typical year, the global solar insolation of Guayaquil is 1825 kwh/m 2 -year, [7]. Meteorological data were generated from METEONORM database [12]. Figure 2: Samples of typical roofing used on Ecuadorian dwellings. The model simulates a social interest dwelling constructed with a low sloped roof a single story with 42 m 2 of area, height is 2.7 m (as seen in figure 3). Table 2 provides U values ( / ) for envelope surfaces in the model. Its fenestration area is 2 m 2 and the model has a unique exterior door. Heat inputs were set for a low profile occupation, lighting of 11.84 W/m 2 for lighting and 5.81 W/m 2 by miscellaneous equipment. Every external surface has an emittance of 0.9, and the thermostat set point for the cooling system was set to 23 C. Table 1: Climatic conditions of a typical meteorological year in Guayaquil, Ecuador [12]. Dry Bulb %RH Average Month Temperature ( C) Dew Point Max. Min. Aveg. Max. Min. Aveg. ( C) Jan 33.4 21.2 26.3 100 34 69 19.8 Feb 31.9 20.9 26.0 100 45 76 21.2 Mar 32.5 21.6 26.3 98 49 77 21.7 Apr 32.5 21.8 26.2 100 45 74 21.0 May 32.8 21.2 25.7 100 40 72 20.0 Jun 30.2 19.0 23.9 98 45 74 18.6 Jul 30.1 18.2 23.7 99 48 72 18.1 Aug 29.7 18.7 23.5 100 45 71 17.8 Sept 30.0 18.4 23.5 97 42 71 17.7 Oct 31.2 19.3 24.0 96 39 70 17.9 Nov 31.5 19.2 24.2 100 41 69 17.8 Dec 32.3 20.8 26.1 97 38 64 18.5

Energy and Sustainability VI 311 Figure 3: Top view of a social dwelling model. Table 2: U values for envelope conditions applied in the model. Envelope surface U (W/m 2 K) Walls 0.86 Floor 3.15 Roof 7.28 Door 1.18 Window 5.83 Changes on annual cooling energy consumption, peak cooling rates and average zone air temperature serve as the performance metric of the different roofing assemblies. The model was set for every value of solar reflectance measured as well as three reference values: opaque reference SR = 0.15, moderate high reflectance SR = 0.60, and high reflectance reference SR = 0.80. 3 Results Table 3 presents the solar reflectance values obtained with procedure E1918A. Results evidence that largest solar reflectance value is from the steel panel sample, while ceramic tiles sample is the smallest. Next, results from Energy Plus simulations reflect the energy performance from each case (as shown in Figure 4). This figure shows a difference of 15.70% of annual cooling demand between a red ceramic tile and steel panel. Also a maximum decrease of 19.31% in September between the two materials is found. Figure 4 displays results of the annual cooling demand and peak cooling rates at varying solar reflectance value. Annual cooling consumption falls as solar reflectance increases, with a maximum change of -43.88% match to SR = 0.8 surface with respect to SR=0.15. A difference of -15.70% of cooling demand between the red tile and steel panel samples was identified.

312 Energy and Sustainability VI Table 3: Reflectance values of pieces tested. Sample Steel panel 0.51 Zinc panel 0.42 Fiber cement 0.32 Red Ceramic Tile 0.29 Also, a maximum decrease of -40.21% for peak cooling rates was observed between limiting values of solar reflectance. While a difference of -14.19% corresponds to red tile and steel panel samples. Figure 4: Monthly electric consumption for roofing with different reflectance values. Table 4 indicates the total annual hours of uncomfortable air temperatures indoors following guidelines of ASHRAE 55 [13]. Results reveal a minor decrease for solar reflectance values up to 0.51. For larger solar reflectances values of 0.6 and 0.8, the reduction of non-comfortable hours is significant. 4 Discussion Synnefa et al. [2], suggest that employment of high solar reflectance roofing yields positive effects in thermal building performance, especially at hot climates, even cities with moderate cooling loads showed improved performance. The hot and humid climate in Guayaquil makes employment of high reflectance roofs appropriate. This paper illustrates the effects on cooling loads and electricity consumption with different solar reflectance values on roofs. Cooling load reduction of the vicinity of 20% could be achieved by changing red ceramic tiles for steel panels. However, changing reflectance of roofing assembly exhibits

Energy and Sustainability VI 313 Figure 5: Annual cooling demand and peak cooling rates versus solar reflectance of roofing. Table 4: Annual hours of uncomfortable temperature. almost no effect on uncomfortable hours inside the dwelling when not using a mechanical cooling system. It is worth noting that samples used in this project were new and clean. Factors such as aging as well as dust were not considered in the project. Synnefa et al. [2] advise regular cleaning of roofing assemblies to avoid reduction on solar reflectance. Bretz and Akbari [14] provide a study of the effects of aging in solar reflectance of assemblies, with reductions of up to 0.15 mostly within the first year. 5 Conclusions SR Not Comfortable time for air temperature [ASHRAE 55] Reduction (%) (HOURS/YEAR) 0,15 2899 0,29 2871 0,95% 0,32 2862 1,28% 0,42 2825 2,54% 0,51 2765 4,61% 0,60 2689 7,24% 0,80 2313 20,22% Via procedure E1918A, solar reflectance of four typical roof samples in Guayaquil was calculated. This low cost method allows getting reliable experimental data at a lower cost when comparing with traditional procedures such as ASTM E903, ASTM C1549 and ASTM E1918. Solar reflectance varied from 0.29 to 0.51, with the best results from the steel panel assembly.

314 Energy and Sustainability VI Energy simulation shows a significant decrease of cooling loads, peak cooling rate with an increase in solar reflectance. It is possible to decrease 15.70% of annual cooling demand and a maximum reduction monthly of 19.31% by switching red ceramic tile with steel panel while maintaining a constant thermal resistivity on the assembly. Besides, for extreme reference values of solar reflectance in the range 0.15 and 0.80, it would be possible to achieve annual energy savings of 61.98 kwh/m 2 or 43.88%. For peak cooling rates, a maximum reduction of 40.21% with a solar reflectance of 0.8 with a baseline SR of 0.15 is possible. A difference of 14.19% between a red tile and steel panel were found. References [1] American Society of Heating, Refrigerating and Air-Condtioning Engineers, Inc., in ASHRAE GreenGuide, The Design, Construction, and Operation of Sustainable Buildings, 2010, pp. 89-102. [2] A. Synnefa, M. Santamouris and H. Akbari, Estimating the effect of using cool coatings on energy loads and thermal comfort in residential buildings in various climatic conditions, 2007. [3] H. Akbari, R. Levinson and S. Stern, Procedure for measuring the solar reflectance of flat or curved roofing assemblies, ScienceDirect, vol. 82, pp. 648-655, 2008. [4] American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc, ASHRAE 90.1 Energy Standard for Buildings except Low- Rise Residential Buildings, Atlanta, 2010. [5] American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc, ASHRAE 90.2 Energy-Efficient Design of Low-Rise Residential Buildings, Atlanta, 2007. [6] Centro Ecuatoriano de Derecho Ambiental CEDA, Hacia una matriz energética diversificada en Ecuador, Quito, 2011. [7] Consejo Nacional de Electricidad CONELEC, Atlas Solar del Ecuador con Fines de generación eléctrica, 2008. [8] American Society Testing Materials, ASTM E903 Standard Test Method for Solar Absortance, Reflectance, and Transmittance of Materials Using Integrating Spheres, 2012. [9] American Society Testing Materials, ASTM C1549 Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer, 2009. [10] American Society Testing Materials, ASTM E1918 Standard Test Method for Measuring Solar Reflectance of Horizontal and Low-Sloped Surfaces in the Field, 2006. [11] U.S. Department of Energy, www.eere.energy.gov/buildings/energyplus/, 2015. [Online]. Available: http://apps1.eere.energy.gov/buildings /energyplus. [Accessed 2015].

Energy and Sustainability VI 315 [12] Swiss Federal Institute of Technology., METEONORM, Global Meteorological Database for Solar Energy and Applied Climatology, Zurich, Switzerland. [13] ASHRAE, Standard 55-1992, Thermal Environmental Conditions for Human Occupancy. [14] S. Bretz and H. Akbari, Long-term performance of high albedo roof coatings, Energy and Buildings, no. 25, pp. 159-167, 1997.