Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN

Similar documents
PinAAcle 900 Series. Atomic Absorption Spectrometers

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

PinAAcle 500. Flame Atomic Absorption Spectrometer

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Atomic Absorption Spectrometry. Quality is the Difference novaa

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Firma: Perkin Elmer Modell: SimAA 6000 Kommentar: Dokumente engl.

Common Challenges facing Laboratories doing Elemental Analysis Today

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA (Zhenghua Renmin Gongheguo Guojia Biaozhun)

National Food Safety Standard

Analysis of 14 Trace Elements in Stainless Steel

Accuracy and Precision. Dilution Error in Error in Factor Accuracy Precision 200 <2% <2%

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Runs On Air. AGILENT 4100 MICROWAVE PLASMA ATOMIC EMISSION SPECTROMETER

Review on Agriculture and Rural Development vol. 2. (1) ISSN

Method Development for Direct Analysis of Mercury by Thermal Decomposition. David L. Pfeil

Skoog, Holler and Nieman, Principles of Instrumental Analysis, 5th edition, Saunders College Publishing, Fort Worth, TX 1998, Ch 33.

Methods for determination of mercury in LP gas

DETERMINATION OF MERCURY IN THE RANGE OF ng/l USING CV-AAS

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Aluminium Determinations in Parenteral Solutions

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Composition Analysis of Animal Feed by HR ICP-OES

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

High-Purity Acids & Reagents

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

Optimizing Purified Sample Recovery on Reverse-Phase HPLC Systems

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

Asian Journal of Food and Agro-Industry ISSN Available online at

By Sandra R. Jones and Betty J. McLain U.S. GEOLOGICAL SURVEY. Open-File Report

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

Supporting Information

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Part 1. Effect of Magnesium Chloride Matrix and Ascorbic Acid Chemical Modifier on Manganese* t To whom correspondence should be addressed.

Fuel Leak Simulation

// XPLORER-NS. Total Nitrogen and Sulfur Analyzer

Cyanide Analysis: Cyanide Chemistry, Methodology, Interferences, Sample Handling and Regulatory Updates

Evaluation of Energy-Dispersive X-Ray Fluorescence for Mobile Analysis of Hazardous Metals in Transuranic Waste

Elemental Analysis (EA)

The Japanese Specifications of Sanitary Napkin. Materials

The image part with relationship ID rid4 was not found in the file. Welcome

Polyvidone Polyvinylpyrrolidone H 2 C H C N

Photolithography I ( Part 2 )

Process Total Organic Carbon Analyzer

C146-E096 TD-20. Shimadzu Thermal Desorption System

IC-D3160 Ion Chromatograph

METALS AND THEIR COMPOUNDS

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

An Innovative Approach for Mercury Capture

Avio 200 ICP-OES Flat Plate

Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY-- DETERMINATION OF CHROMIUM IN WATER BY GRAPHITE

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

WM2008 Conference, February 24-28, 2008, Phoenix, AZ Abstract #8216. Thermal Pretreatment For TRU Waste Sorting

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

Sum Parameter Analysis AOX/TOX. AOX Analyzer multi X 2500

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

The Determination of Trace Elements in Waters using the US EPA Method and the Thermo Scientific icap 6500 ICP-OES (Duo)

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

This method is applicable to the following parameters: Nitric Hydrochloric acid digestion, Instrumental analysis.

US EPA Method using the XSERIES 2 ICP-MS

Fusion UV/Persulfate TOC Analyzer

Basic design of laboratory bioreactor

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

REPORT NUMBER REPORT DATE SEND TO ISSUE DATE Apr 18, Apr 18, 2017 RECEIVED DATE Apr 05, 2017

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

Chem 1120 Pretest 3 Fall 2015

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Greenhouse Gas Measurement Technology

ICP Expert software. Technical Overview. Introduction

TVOC Heated FID VE 7

SSI Atomic Absorption Spectrophotometers AA-6300 Series Consumables

Thermo Scientific icap 7000 Series ICP-OES Accessories Guide

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Fpollutant-free zero air for analytical

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

GENARAL INTRODUCTION TO METALLURGY :Std: XI-CHEMISTRY

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

C196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph

Surface Plasmon Resonance Systems

Lateral epitaxial growth of two-dimensional layered semiconductor heterojunctions

Your partner for the right solution

Analysis of an OTC Multivitamin Tablet Using X-ray Fluorescence Spectroscopy and Atomic Absorption Spectroscopy

Alloys and Solid Solutions

Material Evaporation Application Comment MP P / Optical films, Oxide films, Electrical contacts. Doping, Electrical contacts.

Transcription:

Flame Atomic Absorption Spectrometer (FAAS) Brand : PERKINALMER Model : PinAAcle 900T Custodian : PRADUP MESAWAT SOOKRUTHAI WONGSUBIN Description and Specification FAAS: System Design: Double-beam flame spectrometer and graphite furnace atomizer on a single instrument. Deuterium background correction ensures maximum sensitivity. Monochromator: Wavelength range: 184 900 nm. Diffraction grating: 1800 lines/mm blazed at 236 nm and 597 nm. Focal length: 267 nm Spectra Bandwidths: Automatic slit widths of 0.2, 0.7 and 2.0 nm at their optimized slit height. Detector: Wide-range segmented solid-state detector, built-in low-noise CMOS charge amplifier array. Automatic Lamp 8-lamp mount with built-in power supplies cableless Lumina hollow Selection: cathode and patented EDLs improved sensitivity and extended lamp lifetime. Lamps: Lumina Hollow Cathode Lamps - Unique 2-inch cableless coded lamps automatic setup and provide long lamp lifetime. EDLs designed to deliver the best linearity, sensitivity and precision. Cutting-edge fiber: Burner Heads: Maximize light throughput for improved detection limits. A variety of solid titanium burner heads (5-cm, 10-cm as well as 3-slot) for different flame and sample types. The align burner automatically adjusts the burner head position vertically and horizontally.

Description and Specification FAAS: Nebulizers: Stainless steel or high-sensitivity, corrosion resistant options are available to suit virtually any application. Innovative new Requires no gas line connections. mixing chamber: Flame Atomizer: Gas Controls: Oxidant and fuel monitoring. Keyboard-activated ignition system with airacetylene. Acetylene flow is automatically adjusted prior to the oxidant change when switching to or from nitrous oxide-acetylene operation. Safety Functions: Interlocks ignition if the burner head, the nebulizer/end cap, or the burner drain system is not correctly installed; the liquid level in the drain vessel is incorrect; or gas pressures are too low. Interlocks also will automatically shut down burner gases if a flame is not detected. Sample Introduction System: System consisting of the quick-change spray chamber, burner head and nebulizer units. Alignment of the flame is automatic, using a motorized burner mount for vertical and horizontal burner adjustment. The standard is all-titanium, 10 cm, single-shot burner head for airacetylene operation.

Graphite Furnace Atomic Absorption Spectrometer (GFAAS) Description and Specification GFAAS: System Design: Transversely Heated Graphite Atomizer (THGA)-the graphite tube is transversely heated, providing a uniform temperature profile over the entire tube. Furnace system: An internal purge gas goes though the graphite tube to remove the volatilized matrix vapors during drying and thermal pretreatment. Common Furnace Analytical programs with up to 12 steps can be set up. Each step can be Features: programmed with the following parameters. Temperature: Ambient up to 2600 C in steps of 10 C Ramp Time: 0 to 99 sec in steps of 1 sec Hold Time: 0 to 99 sec in steps of 1 sec Internal Gas Flow: 0 ml/min (gas stop), 50 ml/min (min-flow), 250 ml/min (full flow) Furnace Opening: Pneumatically-operated by software command. Required Inert Gas: Argon-inlet pressure 300 kpa (3 bar) minimum. Furnace Autosampler Graphite Tubes Maximum gas consumption is 700 ml/min. Sample tray with 88 and 148 sampling positions for sample and reference solutions and 1 overflow container for pipette washing. Minimum sample requirement: Ca. 0.1 ml Baseline offset correction, Background correction Using THGA or HGA tubes, both feature integrated platforms for exceptional and are pyrocoated for longer lifetime. Transversely Heated Graphite Atomizer (THGA) and longitudinal Zeeman background correction.

Description and Specification GFAAS: Dispensable Volume: Sample and Reagent: 1-99 μl, selectable in increment of 1 μl. Max. dispensable volume is 99 μl (Sample volume + reagent volume). Flushing volume is fixed at 1.3 ml Electronics: The autosampler is powered from the spectrometer and softwarecontrolled. Background Correction: Zeeman-effect Background Correction-PinAAcle 900T Longitudinal AC Zeeman-effect background correction using a modulated 0.8 Tesla magnetic field. Furnace Camera: View inside the tube for easy autosampler tip alignment and sample dispensing. Monitor drying during analysis for simpler method. Used to monitor drying and pyrolysis during analysis for simpler method development. Data Handing: Readings linear in absorbance (-0.500 A to +2.000A), concentration or emission intensity variable scale from 0.01 to 100 times. Integration times operator-selectable from 0.1 to 120 sec in increments of 0.1 sec. Stabilized Temperature Platform Furnace (STPF): Integrated platform Matrix modifiers Maximum power heating No internal gas flow during atomization

Hydride Generator Model : FIAS100 Description and Specification of Hydride Generator: Flow Injection Mercury System: Quartz FIAS: Mercury/Hydride System: Reductant: The Sample Loop Size: Flow rate (ml/min): The Carrier Solution: FIAS-100 Flow Injection System for cold vapor mercury AA. Single beam low pressure Hg lamp and solar-blind detector with maximum sensitivity at 254 nm. Automatic baseline offset correction (BOC) and control electronics based on SMD (Surface Mounted Device) technology. Peristaltic pump of 8 channels for tubing with 0.13 to 3.18 mm inner diameter. The pump speed is selectable from 30 to 120 rpm. FI switching valve with 5 ports and exchangeable sample loops (500 μl loop supplied as standard). The heated quartz tube atomizer for the determination of As and Se absorption wavelengths below 200 nm. Hg can be easily reduced in solution to generate elemental mercury, known as cold vapor (CV). Speeds up analyses requiring complex sample preparation such as Hg and hydride-forming element. Regulated gas supply used for: As, Se, and Hg. The quartz cell was heated to 900 C for the hydrides and 100 C for mercury vapor condensation in the cell. Delivers improved detection limits (down to the ng range) for mercury and hydride-forming elements. Sodium borohydride for hydrides or stannous chloride for mercury to produce the gaseous vapors. 500 μl for all analytes Flow of 50, 80 and 100 ml/min were used for the arsenic, selenium and mercury determinations. As and Se determination was a 10% (v/v) hydrochloric acid (HCl) solution. For As, the NaBH 4 concentration was increased to 0.5% Mercury was 3% (v/v) HCl. Hg using SnCl 2 as the reducing agent, the reducing solution consisted of 1.1% (w/v) SnCl 2 (from SnCl 2 2H 2 O) in 3.0% (v/v) hydrochloric acid. The selenium hydride generation reducing agent was an aqueous solution of 0.2% (w/v) NaBH 4 in a 0.05% (w/v) NaOH.

Lamp for Flame Atomic Absorption Spectrometry (FAAS) No. EDL Lamp Char. Conc. Conc. Abs. -20% +20% Linear to Zero 1 As 0.59 25 0.186 0.149 0.224 55 2 Cd 0.01 0.5 0.220 0.176 0.264 1 3 Pb 0.18 8 0.196 0.156 0.235 10 4 Se 0.3 15 0.220 0.176 0.264 100 No. HCL Lamp Char. Conc. Conc. Abs. -20% +20% Linear to Zero 1 Ag 0.02 1.1 0.242 0.194 0.290 1 2 Au* 0.18 7 0.171 0.137 0.205 50 3 B* 13 600 0.203 0.162 0.244 400 4 Ca* 0.062 3 0.213 0.170 0.255 5 5 Co 0.053 3 0.249 0.199 0.299 1 6 Cr* 0.078 4 0.226 0.181 0.271 5 7 Cu 0.025 1.3 0.229 0.183 0.275 1.6 8 Fe 0.04 2 0.220 0.176 0.264 3 9 K* 0.02 1 0.220 0.176 0.264 1 10 Mg 0.004 0.18 0.220 0.176 0.264 0.25 11 Mn 0.016 1 0.275 0.220 0.330 0.6 12 P* 290 140000 - - - 10000 13 Zn 0.006 0.3 0.220 0.176 0.264 0.75 *A spacer is required for this element. For analysis of complex samples, the addition of a spacer may be desirable to reduce chemical interferences.

Lamp for Graphite Furnace Atomic Absorption Spectrometry (GFAAS) No. EDL Characteristic Mass ( g/l for A - s) Modifier Lamp (pg/0.0044 A - s) 1 As 40 pg /0.0044 A - s 50 g/l for 0.11 A - s 0.005 mg Pd + 0.003 mg Mg(NO 3 ) 2 2 Cd 1.3 pg /0.0044 A - s 2.0 g/l for 0.13 A - s 0.05 mg NH 4 H 2 PO 4 + 0.003 mg Mg(NO 3 ) 2 3 Hg 220 pg /0.0044 A - s 400 g/l for 0.16 A - s 0.005 mg Pd + 0.003 mg Mg(NO 3 ) 2 4 Pb 30 pg /0.0044 A - s 50 g/l for 0.15 A - s 0.05 mg NH 4 H 2 PO 4 + 0.003 mg Mg(NO 3 ) 2 5 Se 45 pg /0.0044 A - s 100 g/l for 0.20 A - s 0.005 mg Pd + 0.003 mg Mg(NO 3 ) 2 No. HCL Characteristic Mass ( g/l for A - s) Modifier Lamp (pg/0.0044 A - s) 1 Ag 4.5 pg/0.0044 A - s 5.0 g/l for 0.10 A - s 0.005 mg Pd + 0.003 mg Mg(NO 3 ) 2 2 Au 18 pg/0.0044 A - s 40 g/l for 0.20 A - s 0.005 mg Pd + 0.003 mg Mg(NO 3 ) 2 3 B 600 pg/0.0044 A - s 2000 g/l for 0.30 A - s 0.005 mg Ca 4 Ca 1.0 pg/0.0044 A - s 2.0 g/l for 0.18 A - s none 5 Co 17 pg/0.0044 A - s 20 g/l for 0.10 A - s 0.015 mg Mg(NO 3 ) 2 6 Cr 7.0 pg/0.0044 A - s 10.0 g/l for 0.13 A - s 0.015 mg Mg(NO 3 ) 2 7 Cu 17 pg/0.0044 A - s 25 g/l for 0.15 A - s 0.005 mg Pd + 0.003 mg Mg(NO 3 ) 2 8 Fe 12 pg/0.0044 A - s 20 g/l for 0.15 A - s 0.015 mg Mg(NO 3 ) 2 9 K 2.0 pg/0.0044 A - s 5.0 g/l for 0.22 A - s none 10 Mg 0.4 pg/0.0044 A - s 1.0 g/l for 0.22 A - s none 11 Mn 6.3 pg/0.0044 A - s 10 g/l for 0.14 A - s 0.005 mg Pd + 0.003 mg Mg(NO 3 ) 2 12 P 210000 pg/0.0044 A - s 20000 g/l for 0.08 A - s 0.020 mg Pd + 0.005 mg Mg(NO 3 ) 2 13 Zn 1.0 pg/0.0044 A - s 2.0 g/l for 0.18 A - s 0.005 mg Mg(NO 3 ) 2