Zinc Silicate (Inorganic)

Similar documents
PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

Measured in accordance with ASTM D 2697.

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Aliphatic Acrylic-Polyester Polyurethane

Refer to Substrates & Surface Preparation.

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Matte Volume Solids 80 ± 2% (ISO 3233:1998) VOC. Overcoating Data 10ºC 25ºC 35ºC Min. 10 hours 4 hours 3 hours Max. 6 months 6 months 6 months

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Refer to Substrates & Surface Preparation.

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Property Test/Standard Description

Ganicin 2.8 ZR-E Zinc-Rich Epoxy Primer

TECHNICAL DATA SHEET

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Ganicin 2.8 ZR- U Zinc-Rich Polyurethane Primer

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

two component high build amine adduct cured phenolic epoxy primer

Property Test/Standard Description

05030 METAL FINISHES/09800 SPECIAL COATINGS COLD GALVANIZING COMPOUND

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

Property Test/Standard Description

TT-P-1757B Type I, Class C, Aerosol Zinc Chromate Primer. A one component, alkyd base, corrosion inhibiting zinc chromate primer.

TECHNICAL DATA SHEET

Property Test/Standard Description

One-component, heat-resistant silicone acrylic topcoat primarily for the PPG HI-TEMP 1027 primer or the PPG HI-TEMP 222 G primer

Coating Types. Coating Systems. Coating Basics. Why coatings are used Component of coatings Methods of protection Service environment

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical)

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

Property Test/Standard Description

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

COATING SPECIFICATION INORGANIC ZINC SILICATE, EPOXY PRIMER MIST-COAT, TWO PACK ACRYLIC TOP COAT ON STEEL OR CAST IRON

Property Test/Standard Description

HEAT-FLEX HI-TEMP 1200 Coating Under Insulation

Technical Data Sheet EPOXY PRIMER 3:1 Anti-corrosion epoxy primer RELATED PRODUCTS. Epoxy primer hardener EPOXY PRIMER HARDENER PROPERTIES

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

PPG HI-TEMP 1000 V (AMERCOAT 873) PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

PRODUCT DATA SHEET Sika Unitherm Platinum

Technical Data Jotamastic 80 MIO

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

NC Sanding Sealer Clear Clear Nitrocellulose Sanding Sealer

Date of issue: 5 October 2017 Page: 1/6

Pre-qualification testing in accordance with NORSOK M-501, Rev. 3/4, System 7, suitable for splash zone. Property Test/Standard Description

SECTION 1045 PAINT FOR STRUCTURAL STEEL

SURFACE PREPARATION FOR SYNTHETIC ROPES

Corlar LV PR 178 Series Epoxy Primer

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

CORLAR 2.1 ST SATIN HIGH SOLIDS EPOXY MASTIC (formerly Corlar 25P )

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

PRIMERS & SURFACE PREPARATION GUIDE

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Technical Data Sheet

CIM IG 13 11/06. Instruction Guide

Waterproofing and Damp-proofing Cementitious Slurry

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

DMS STRUCTURAL STEEL PAINTS PERFORMANCE

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Maximum Rust Protection!

Aviox CF Primer 37124

Instruction Guide APPLICATION OF CIM TO CONCRETE

Property Test/Standard Description

Aerodur CF Primer 37047

White, a range of ready-mixed colours, and colours from the Dulux Colour System

Technical Information Sheet

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

Normadur 65 HS. Technical Data PROPERTIES AND RECOMMENDED USAGE TECHNICAL DATA

Intertherm 751CSA Application Guidelines

PRODUCT DATA SHEET SP-3888

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

Section COATING RESTORATION

PROTECTO-CRETE 800/800SF

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

BTM BT2K 600. Areas of Use

Data Sheet 1806 Englisch

HYDROJETTING INFORMATION. a six page issue October 1999

The Application Guide offers product details and recommended practices for the use of the product.

Two component solvent-free epoxy system for creation of self-levelling floors. Gloss <4% <70% IR4

SP-100 Equipment Wash SP-110 Tool Cleaner

TECHNICAL DATA SHEET

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

Coronado Industrial Coatings Old County Road Edgewater, Florida FAX Line. Min Recoat:

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

Make your floor a unique artwork!

DULUX WEATHERGUARD FINE TEXTURED

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction

Troubleshooting Guide

Ballast Water Tanks Repair Guide for Crew

Rust Bullet Home and Farm FAQ s

There are many surface contaminants that can interfere with coating adhesion. The following are the most common:

Application Guide AC- 130 Metal Alloy Surface Preparation For Bonding

4970 PRIME COAT FZ Two components zinc phosphate epoxy product

Transcription:

Product code: 477-041: part A 477-042: part B General description: Two-component, zinc-ethyl silicate-. Forms a continuous coat of metallic zinc that provides cathodic protection to metal (as in hot galvanization). Complies with the composition and performance requirements of SSPC paint 20. Product Features: Superior anti-corrosive primer for protection of steel. Fast drying. Resistant to dry heat at temperatures up to 450ºC. Recommended Uses: Suitable as an excellent anti-corrosive coat for steel, ventilation pipes, sub-insulation and oils and fuel storage. In clean or mildly corrosive environments, may be applied in a single coat of 75 microns. In acidic or alkaline environments, must be coated with a top-coat such as chlorinated rubber, vinyl, epoxy or Polyurethane. Technical Data: Shade: Grey Gloss at 60 0 : Matt Volume Solids: 69% Dry film thickness per coat: 50-75 micron (Caution: Capillary cracking may occur in layers thicker than 120 microns). Calculated coverage per coat* (sqm./liter): 9.2-13.5 in the above thicknesses Recommended thinner: Thinner 280 Mixing ratio by weight: part A:part B = 100:266 Shelf life**: 6 months Drying times (hours): Drying method 5 0 C 0 C 15 25 0 C 40 0 C Touch dry 30 min 20 min 10 min 5 min

Hard Dry 3 3.5 1 0.5 Minimum interval between coats Maximum interval between coats 18 9 4.5 1.5 Extended Extended Extended Extended Pot life (hours): 0 5 C 0 C 15 25 0 C 40 0 C time 12 8 4 2 Surface preparation and system recommendation: All surfaces to be coated should be clean, dry and free from contamination. Prior to paint application all surfaces should be assessed and treated in accordance with ISO 8504-2000. Blast area to Sa-2.5 (per Swedish Standard) and profile of 50-75 microns. If oxidation has occurred between blasting and application of Zinc Silicate the surface should be re-blasted. Apply one coat of Zinc Silicate to 75-80 microns. Dry film thickness of this product shall not exceed 120 microns, to avoid possible formation of mud cracking. Application: Painting method Inlet pressure atmospheres Spraying pressure PSI Nozzle diameter Recommended percentage thinning with Thinner 280 Brush/roller - 5% Spraying with air gun up to 60 microns per layer 3-4 15-20% Airless spraying with a compression rate of at least 45:1 5-6 2000-3000 0.021"- 0.023" 10-15% Thinner 280 may be added as recommended in the table above.

Zinc Silicate is applied in 2 parts, a liquid binder (Part A) and a powder component (Part B). The powder (Part B) should be slowly added to the liquid binder (Part A) whilst stirring with a mechanical mixer. Do not add liquid to powder. Material should be filtered prior to application, and should be constantly mixed in the pot during spraying. After mixing product should be used within the working pot life specified. Thinner for Cleanup: Thinner 280. Recoating aged zinc silicate: At relative humidity below 50%, curing will severely decrease and may damage the coat, humidity may be increased by water spraying. Before over-coating with recommended topcoats ensure the Zinc Silicate is fully cured. A solvent rub test conforming to ASTM D4752 should be undertaken. A value of 4 indicates a satisfactory degree of cure for over-coating purpose. If weathering has occurred all zinc salts should be removed from the surface by fresh water washing, and if necessary scrubbing with bristle brushes. Typical intermediates and topcoats: Epogal, Epoxy EA9, Ecopoxy 60, Ecopoxy 80, Multipoxy, Epitamarin Solekote. In some cases it may be necessary to apply a mist coat of suitable viscosity to minimize bubbling. This depends on the age of the Zinc Silicate, surface roughness and other conditions during application and curing. An epoxy sealer coat such as Epogal or Epoxy EA9 can be used to reduce bubbling problems. Notes regarding painting: Top coating: The dried film of Zinc Silicate is very porous, containing a large amount of air in the pores. If it is top-coated, air may be entrapped or thinner may be released into the film, which may lead to blisters formation (boiling). To avoid this, spray a diluted coat of the desired paint, diluted up to 30%, in the form of thin mist, to ensure maximum penetration into the pores of the Zinc Silicate film and expulsion of the entrapped air. Then a full top-coat, in the desired thickness may be applied. INSTRUCTIONS FOR PROPER USE AND SOME REMARKS REGARDING APPLICATION: Product Description Two-component primer, designed for anti-corrosive priming of steel. The protection is provided by a continuous metallic film, which upon contact with ferrous substrate provides cathodic protection to the metal. The continuity of the zinc film is achieved through the extremely high content of metallic zinc particles and consequent low content of binder, thus creating the essential contact between the zinc particles. Special properties and application a) In clean or mildly corrosive environments, Zinc Silicate can serve as a single-coat protective primer, provided that the film thickness is 60 microns at least. Zinc metal is quickly attacked by highly acidic or alkaline environments or by immersion in sea-water. If the paint is intended for use in such environmental conditions, it is essential to top-coat it with a suitable chemical resisting top-coat (such as chlorinated rubber, vinyl, or epoxy). b) Heat resistance: The binder of this primer is inorganic silicate. In contrast to organic binders in normal paints, this composition provides dry heat resistance up to 400-450ºC.

Drying mechanism The ethyl silicate based binder reacts after application with atmospheric moisture. This reaction increases the specific weight of the polymer while releasing organic fractions. After a few hours, depending on the relative humidity, an inorganic polymeric silica matrix is formed Surface preparation Since this cathodic protection is based on an electro-chemical mechanism, it is essential to provide direct contact between the coat and the metal. Even in the presence of a sound primer, other than Zinc Silicate (such as shop primer, it is essential to remove it completely. Prepare surface by blasting to near white metal (Sa-2.5 per Swedish Standard) for normal exterior resistance and to white metal (Sa 3) where the object is intended for immersion resistance. The desirable metal profile after sandblasting is 25-50 microns. Remove dust and other contaminants before application. Apply Zinc Silicate as soon as possible after cleaning to avoid rust onset and contamination. Never leave cleaned surface exposed overnight. Paint preparation To achieve high zinc particles content, work with a very low viscosity binder. Yet, as specific weight of zinc is very high, it tends to settle rapidly in thin medium. Therefore, the product is supplied in two parts. Ascertain that the packaging is tightly closed to prevent moisture penetration. Part A is the binder and part B is the zinc powder (discard the small bag of desiccant inside the zinc powder before mixing part A with part B). Mixing procedure Start stirring part A in a mechanical mixer. Add the zinc powder (part B) slowly into part A, while mixing. Rapid addition may cause lumps formation due to insufficient wetting of the pigment. Continue stirring until a completely homogeneous and smooth mixture is obtained. Strain through a 30-60 mesh sieve before application, to remove any lumps and granules. Thin, as needed, using only thinner 280 (about 10-30%, according to volume) and no other thinner. Painting equipment You can apply this paint using airless sprayers, designed to spray this product. Due to high wear rate, use sprayers with high wear resistance and a pressure pot with a mixer. Small areas may be painted by brush. Application This paint is very sensitive to application conditions and any deviation may cause surface defects described below. Film thickness Recommended dry film thickness is 75 microns in one coat. Do not apply dry thickness coats exceeding 120 microns to avoid spontaneous mud cracking. Control applied wet thickness constantly, because it is very difficult to correct any deviation in film thickness, due to poor adhesion of the coats after the primer dries. Where dry thickness is lower than the recommended thickness, compensate during application of following coats. In case of mud cracking, remove loose coats and repair by applying a Zinc Rich Epoxy coat. It is best to perform this repair using a brush or by spraying a thinned coat, while avoiding unnecessary overlaps. In case of Over Spray, the painted surface is very rough and covered by a film; the paint is uneven and lacks mechanical properties. Remove the powdery spray with emery cloth and smooth the surface evenly. We then recommend rinsing with water. Over spray May occur due to several causes: a) Insufficient thinning. b) Excessive distance between the spray nozzles to the surface.

c) Application during hot and dry weather or when the metal plate is very hot. Drying conditions As stated above, the drying mechanism is based on chemical reaction with water vapors in the air. Therefore, it is not recommended to apply this paint in relative humidity below 50% and at environmental temperatures over 40ºC. When application must be performed at relative humidity below 50%, spray water mist on the surface after the paint is dry to touch (about 4 hours), to speed the paint s hardening. This paint requires 7 days of drying to develop maximum resistance to solvents. Do not apply when rain, heavy dew or frost are expected during or within two hours after application. Under correct conditions, the paint dries to touch after a few minutes and to treatment after 24 hours. Drying time for top-coating is 24 hours minimum. Cautions Application and use of the product should be done in accordance with the Israeli Safety, Health and Environmental regulations. Read the safety instructions and warnings on the safety data sheet which may be obtained from the Tambour Safety Department Phone: 04-9877483 and on the product label. Keep away from fire and sparks. Non-edible. Allow adequate ventilation of the workplace. When spraying do not inhale fumes. Use appropriate protective measures, refer to the Safety Data Sheet. Never mix this material with others when not specifically recommended by us. General notes: The data presented are based on experience and knowledge accumulated over the years. We reserve the right to update and/or change it without notice. Obtaining the desired results is contingent upon correct product application while adhering to instructions of use. Please ensure you check before applying the product that it is indeed designed for the intended usage and that the surfaces to be painted are properly prepared to apply the product. For additional information call Tambour's professional hotline: *6477 * Actual coverage depends on several factors: the surface, the application method, paint's shades, the painter's skill and weather conditions at the site. It is customary to assume that it accounts for about 75% of the calculated coverage. ** At 25ºC and 65% relative humidity.