Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Similar documents
GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Module 4:Preloading and vertical drains Lecture 10:Introduction to preloading and vertical drains. The Lecture Contains:

SUBSOIL IMPROVEMENT WORKS AT DVIZ, HAIPHONG, VIETNAM

SPECIFICATION FOR PREFABRICATED VERTICAL DRAIN

PVD Ground Improvement System

Earthwork and Ground Technology. Site Improvement

Improving Engineering Properties of Soft Soil Using Preloading and Prefabricated Vertical Drains

Chapter 11 Compressibility of Soil

STANDARDIZATION IN GEOTECH SECTOR V.K.PATIL

WORKING OF PREFABRICATED VERTICAL DRAIN- Α CASE STUDY

COMPRESSIBILITY OF PEAT

Prefabricated Vertical Drains

Study of Various Techniques for Improving Weak and Compressible Clay Soil under a High Earth Embankment

AMERDRAIN. Prefabricated Vertical Soil Drainage Systems ICK. Soil drainage method for accelerating settlement through vertical drainage

Importance of tailings properties for closure

Downloaded from Downloaded from /1

Horizontal Coefficient of Consolidation of Soft Bangkok Clay

Performance Analysis of Sand Columns in Recharge Reservoir

PE Exam Review - Geotechnical

POTENTIAL OF BAMBOO PILE AS REINFORCEMENT OF PEAT SOIL UNDER EMBANKMENT

A Vacuum Consolidation Method Application Case for Improving Dredging Slurry

Syed Abdul Mofiz 1, Member ASCE and Fellow IEB, Mohd. Raihan Taha 2, Member IEM, and Md. Mizanur Rahman 3, Member IEB

Module - CE 3132 Geotechnical Engineering Assignment Triaxial Test Marks 10% Learning Outcome

Behavior of Reinforced Embankment on Soft Ground with and without Jet Grouted Soil-Cement Piles

Study of Interlocking Effect by the Push Test

NPTEL Course GROUND IMPROVEMENT USING MICROPILES

Modular Sediment Barriers (Instream)

Seismic Behaviour of RC Shear Walls

CIV E Geotechnical Engineering I Consolidation

A THREE DIMENSIONAL STUDY OF THE EFFECT OF SOIL EROSION ON RIGID PIPES

The Improvement Of Soft Soil Layer For Toll Road Embankment On Java North Shore A Study Case On Jalan Tol Pejagan Pemalang

True Stress and True Strain

A.Zh. Zhussupbekov, R.E.Lukpanov, A.Tulebekova, I.O.Morev,Y.B.Utepov 1 ) 1) Geotechnical Institute of L.N. Gumilyov Eurasian National University,

Soil distrubance associated with mandrel-driven prefabricated vertical drains: field experience

Proceedings Tailings and Mine Waste 2011 Vancouver, BC, November 6 to 9, 2011

Foundation Engineering CE Introduction. Prof. H. Alawaji. Room No. 2A- 47/1, Tel

IMPROVEMENT OF LOAD CARRYING CAPACITY OF BC SOIL USING REINFORCED STONE COLUMN

Grade separated interchange at the intersection of U.S. Hwy 17 Bypass and Farrow Parkway

GEOGRID REINFORCED RAILWAYS EMBANKMENTS: DESIGN CONCEPTS AND EXPERIMENTAL TEST RESULTS

STATIC ALTERNATING CYCLIC HORIZONTAL LOAD TESTS ON DRIVEN

Experiences on embankment fill in land expressway over soft ground

Colbonddrain. Colbonddrain. Next Generation. Installation SOIL CONSOLIDATION. Colbond. Proven Performance. Unique Core Design

Introduction to SoilWorks for Practical Design. MIDAS Information Technology

Reinforced Concrete Column Design

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Special Reinforced Concrete Structural Walls

Application of Vibro Techniques for Infrastructure Projects in India

Analytical and Numerical Solutions of Tunnel Lining Under Seismic Loading and Investigation of Its Affecting Parameters

GEOTECHNICAL & SOILS LABORATORY PERMEABILITY TEST : CONSTANT HEAD & FALLING HEAD

SOIL PRESSURE IN EMBANKMENT STABILIZATIONS

Geotechnical Performance of ATA -Treated Fluid Fine Tailings

CE 6012 Ground Improvement Techniques Question Bank

TUNNEL LINER PLATE INTRODUCTION GENERAL APPLICATIONS CHAPTER 11

Leachate Management Leachate Control and Collection

Performance of Mechanically Stabilized Earth walls over compressible soils

Geoguide 6 The New Guide to Reinforced Fill Structure and Slope Design in Hong Kong

Filter Tube Barriers (Instream)

Rapid Drawdown with Effective Stress

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

SPECIFICATION FOR PREFABRICATED VERTICAL DRAINS

Effectiveness of vertical drains in soft clay with special reference to smear effect

BEHAVIOR IMPROVEMENT OF FOOTINGS ON SOFT CLAY UTILIZING GEOFOAM

GEOTECHNICAL CHARACTERIZATION OF MINE WASTE MATERIALS (ZINC/LEAD MINE) FROM RAJPURA DARIBA MINE, UDAIPUR ABSTRACT

Standards for Soil Erosion and Sediment Control in New Jersey May 2012 STANDARD FOR RIPRAP. Conditions Where Practice Applies

GEOSYTHETIC SLOPE SPEC-V0704rev.doc STANDARD SPECIAL PROVISION FOR GEOSYNTHETIC REINFORCED SLOPE CONSTRUCTION

FE Review Mechanics of Materials

Design Data 6. Loads and Supporting Strengths Elliptical and Arch Pipe. Values of B d

This paper describes the salient features of a

Experience of a Large Scale Unintentionally Long Surcharge on Organic Soils

In-plane testing of precast concrete wall panels with grouted sleeve

Homework # 4 - Solutions Fluid Flow (5 problems)

Geotechnical Properties of FGD Scrubber Material

WEEK 9 ACTIVITY. Lecture (3 hours) Self Assessment. 34 slides

Reproducible evaluation of material properties. Static Testing Material response to constant loading

Offshore Windfarm Design OE Foundations

LATERAL CAPACITY OF SKIRT FOUNDATION ON LOOSE SUBMERGED SAND

IMPROVEMENT OF THE DEFORMATION CAPACITY BY THE USE OF FIBERS

POROSITY, SPECIFIC YIELD & SPECIFIC RETENTION. Physical properties of

Use of Polymer Geogrid Composite to support rail track over weak saturated clay subgrade a case study

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

Shaking table tests in earthquake geotechnical engineering

MECHANICAL PROPERTIES PROPLEM SHEET

Stormwater Retention Pond Recovery Analysis

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

Chapter Five Torsion. Reinforced Concrete Structures 2 (CEng-3122)

BEHAVIOUR OF SPIRAL REINFORCED LIGHTWEIGHT AGGREGATE CONCRETE COLUMNS

A Study of Loading Time Effect in Oedometer Test

Providing proper drainage system

COMPOSITE MATERIALS HANDBOOK. Volume. Structural Sandwich. Composites

Sediment Basin. Fe= (Depends on soil type)

Comparison of Prefabricated Cage System with Existing Reinforcement Methods in Concrete Columns

Licensing International Engineers into the Profession (LIEP)

TEST STUDY ON BASIC STATIC CHARACTERISTICS OF CABLE SUPPORTED BARREL VAULT STRUCTURE

DESIGN OF WALLS FOR SHEAR

Application of Geotextiles in Pavement Drainage Systems

ENVIRONMENTAL ENGINEERING-I

AVM Drain Board 2000/2020

Converting slurry tailings facilities to filtered dry stacks a case history. John Lupo Newmont Mining Corporation Marcelo Mussé - Consultant

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Transcription:

49

Module 3: Lecture - 11 on Compressibility and Consolidation

Contents Stresses in soil from surface loads; Terzaghi s 1-D consolidation theory; Application in different boundary conditions; Ramp loading; Determination of Coefficient of consolidation; Normally and Over-consolidated soils; Compression curves; Secondary consolidation; Radial consolidation; Settlement of compressible soil layers and Methods for accelerating consolidation settlements.

Example problem An oil tank is to be sited on a soft alluvial deposit of clay. Below the soft clay is a thick layer of stiff clay. It was decided that a circular embankment with sand drains inserted into the clay would be constructed to pre-consolidate the soil. The height of the embankment is 6 m and the saturated unit weight of the soil comprising embankment is 18 kn/m 3. The following data are available: Thickness of clay = 7 m; m v = 0.2 m 2 /MN; c v = 3.5 m 2 /year; c h = 6.2 m 2 /year; d w = diameter of sand drain = 0.3 m; The desired degree of consolidation is 90% in 6 months. Determine the spacing of a square grid of the sand drains such that when the tank is constructed the maximum primary consolidation settlement should not exceed 20 mm.

Solution ρ c = m v H ( σ) = 0.2 x10-3 x 7 x (18 x6) = 151.2 x 10-3 m = 151.2 mm By substituting U = U v,r = 90% and U v = 19%; U r can be calculated using: U r = 88% n = d e /(2r w ) = d e /d w = r e /r w

Solution Try n = 5 T r = 34.4/5 2 = 1.376 U r = 100% > 88% Try n = 10 T r = 34.4/10 2 = 0.3444 U r = 85% < 88% Hence OK. S = r e /(0.56) = n r w /(0.56) = 10 (0.3/2)/(0.56) = 2.67 m n = r e /r w Adopt 300 mm dia. Vertical drain at 2.7 m c/c

Example problem A road embankment is constructed on top of a 9.2m thick layer of clay, sandwiched between silty sand at the top, and dense sand at the bottom. The required degree of consolidation before the embankment construction is 90%, within 9 months. For this purpose, sand drains of 450mm diameter, need to be installed in a square arrangement. Estimate the spacing of the drain. From laboratory tests, assume that c h = 0.288 m 2 /month and c v = 0.187 m 2 /month

Application of PVDS for approach road embankment After De (2010)

Application of PVDS in ash pond dam raisings

Typical details of PVD Rectangular c/s consisting of a synthetic geotextile jacket surrounding a plastic core and are made with non-woven PET/PP geotextiles. Functions of drain jacket: Prevents closure of internal drain flow under lateral soil pressure To form a surface which allows natural soil filter to develop to inhibit movement of soil particles into the drain. Functions of drain core: To support the filter fabric To provide longitudinal flow paths along the drain length To provide resistance to longitudinal stretching as well as buckling of drain

PVD installation procedure steps (After Kirsch, 2004)

Typical design of anchors and their installation (After Kirsch, 2004)

Details of splicing Drain type 1 Drain type 2

PV drain properties a) Equivalent diameter of drain The conventional theory of consolidation with vertical drains assumes that the vertical drains are circular in cross-section. Therefore, a band-shaped drain needs to be converted to an equivalent circular diameter, which implies that the equivalent diameter of a circular drain has the same theoretical radial drainage capacity as the band-shaped drain. Hansbo (1981) Rixner et al. 1986

PV drain properties b) Filter and apparent opening size (AOS) The general guideline of the drain permeability is given by: k filter > 2 k soil Where, O 95 indicates the approximate largest particle that would effectively pass through the filter; d 85 indicates the diameter of clay particles corresponding to 85% passing. 3 24

PV drain properties c) Discharge capacity The discharge capacity of the PVD is required to analyze the drain (well) resistance factor. In practice, well resistance can develop due to: a) Deterioration of drain filter may lead to a significant reduction of the cross-section b) Fine soil particles may pass through the filter and decrease the area available for flow c) Folding of drain due to soil settlement may result in a reduced discharge capacity. Discharge capacity = f ( volume of the core, the lateral earth pressure acting on drains, possible folding, bending and twisting of drain due to large settlement, infiltration of fine soil particles through the filter, and the biological and chemical degradation).

PV drain properties c) Discharge capacity The actual discharge capacity q w is given by: Where F t, F c, and F fc are the influence factors due to time, drain deformation and clogging, respectively. The term q req is the theoretical discharge capacity calculated from Barron s theory of consolidation: Where, ε f is the final settlement of the soft soil equivalent to 25% of the length of the drain installed to the soft ground; U 10 is the 10% degree of consolidation; l is the depth of the vertical drain, c h is the horizontal coefficient of consolidation and T h = Time factor for radial consolidation. After considering all the worst conditions that may occur in the field, the discharge capacity qw of the PVD could be 500 800 m 3 /year, but reduced to 100-300 m 3 /year where i =1 under elevated lateral pressure (Rixner et al. 1986)

Summary of discharge capacity specified in different projects (After Bo, 2004) Discharge capacity, q w, is defined as the volume of water per unit time that can conduct along the core of a PVD in the axial direction under a unit hydraulic gradient (q w = Q/i) [To convert into m 3 /year multiply by 31.536]

Required drainage capacity as a function of PVD length and k of the soil (After Bo, 2003)

Reduction of flow area caused by deformation of the filter

Drain with and without smear zone (After Kirsch, 2004)

Time required for radial consolidation for PV drains (Modified by Hansbo, 1981) Hansbo (1981) modified by including disturbance effect and drain resistance factor t = time required to achieve U h F(n) = n 2 /(n 2-1) ln n (3n 2-1)/4n 2 For n >20; 1/n 2 0 and n 2 /(n 2-1) = 1 = ln (n) 3/4 F s = Factor for soil disturbance = [(k h /k s )-1] ln (d s /d w ) F r = Factor for drain resistance = πz (L-z) (k h /q w ) Z = distance below the top surface of the compressible soil layer; L = Effective Drain length (H for 1 way drainage; H/2 for 2 way drainage; H = thickness of clay)

Example problem PVDs were installed in a compressible clay layer of 10 m thickness in a square pattern with a spacing of 2 m. The PVD used is 100 mm wide and 4 mm thick. The coefficients of consolidation clay in the vertical and horizontal directions is 2 m 2 /year and 3 m 2 /year. The boundary below the clay was impervious. Calculate the degree of consolidation achieved in one years time.

Solution d e = 1.128S = 1.128 x 2 = 2.256 m = 2256 mm d w = 2(a+b)/π = 2(100+4)/3.1415 = 66 mm F(n) = ln(n) 0.75 = ln (2256/66) -0.75 = 2.78 T r = Time factor due to radial drainage = tc h /d e2 = 1 x 3/(2.256) 2 = 0.589 Degree of consolidation due to radial drainage: 1 e [-8*0.589/2.78] = 82% Time factor due to vertical drainage T v = 2 x1/10 2 = 0.02 Degree of consolidation due to vertical drainage: U v = 16% Uv,r = 85%

Example problem In the previous problem, assume that smearing ratio is 3 and the coefficient of consolidation of smeared soil is 1.5 m 2 /year. Calculate the degree of consolidation achieved in one years time. Solution: Degree of consolidation due to radial drainage: 1 e [-8*0.589/3.88] = 70% Uv,r = 70% Comparing the answers, it can be seen that the degree of consolidation U v,r has reduced due to smear effect.

Device for measuring discharge capacity of deformed drain (After Kirsch, 2004)

Typical PVD discharge capacities in straight and deformed conditions (After Kirsch, 2004)

Tensile strength test for PVD It should have adequate tensile strength so that it can sustain the tensile load applied during installation. 1 kn @ 10% strain (Min.) Necking reduces discharge capacity (After Kirsch, 2004)

Tensile stress vs strain measured for two typical drains (After Kirsch, 2004)

Typical specifications of PVD (After Kirsch, 2004)

Circular type of drain used for vacuum loading projects (After Kirsch, 2004)

Schematic arrangement of vacuum preloading system After Chu et al. 2000

Direct connection of PVD with vacuum preloading system