PART 2D. Section 7.2 of SJRWMD Special Publication SJ93-SP10

Similar documents
Estimating the Seasonal High Water Table: A Mix of Art & Science

August 15, 2006 (Revised) July 3, 2006 Project No A

Report of Preliminary Geotechnical Engineering Investigation for Ponds

Continuous Simulation Modeling of Stormwater Ponds, Lakes, & Wetlands: A BUILT-IN APPLICATION OF PONDS 3.2

SUMMARY REPORT OF A GEOTECHNICAL SITE EXPLORATION LACROSSE CITRUS REPOSITORY LACROSSE, ALACHUA COUNTY, FLORIDA. GSE PROJECT No.

Applicant s Handbook, Volume II (including Appendices A through F`) is Incorporated by Reference in Rule , F.A.C.

Stormwater Retention Pond Recovery Analysis

This report presents the findings of the subsurface exploration concerning the design of the taxiway rehabilitation. Description

Subsurface Environmental Investigation

Determination of Design Infiltration Rates for the Sizing of Infiltration based Green Infrastructure Facilities

REPORT OF GEOTECHNICAL EXPLORATION AND ENGINEERING ANALYSIS

November 13, IP3406. Mr. Uriah Sowell Rooney Engineering 115 Inverness Drive East, Suite 300, Englewood, CO 80112

Typical Subsurface Profile. November 28, 2016

Infiltration Testing For Stormwater BMPs: What Would Mickey Mouse Do?

HYDRIC SOILS. By Neal Svendsen Resource Soil Scientist Natural Resources Conservation Service Sept 2006

SECTION 1 BIO-INFILTRATION BUMP OUTS (BIBO)

APPENDIX D EXTINCTION-DEPTH DETERMINATION

APPENDIX A DRAINAGE STUDY PHASE 2 ALTERNATIVE IMPROVEMENTS CRYSTAL LAKE ALTERNATIVE 4C IMPROVEMENTS LAKEWOOD PIRATELAND SWASH HORRY COUNTY, SC

November 13, IP3406. Mr. Uriah Sowell Rooney Engineering 115 Inverness Drive East, Suite 300, Englewood, CO 80112

Background Information on the. Peace River Basin

Jacobi, Toombs, and Lanz, Inc.

Ardaman & Associates, Inc. Geotechnical, Environmental and Materials Consultants

GREEN CITY, CLEAN WATERS

Re: Geotechnical Consultation for Storm Infiltration Robert Louis Stevenson ES Modernization th Avenue San Francisco, California

Septic Tank Soil Treatment Systems

April 7, Webster Street Sub-Surface Stormwater Storage System Bid No Bid Date: 4/13/17 ADDENDUM NO 1

Report of Geotechnical Engineering Investigation OIA SOUTH CELL LOT (W340) AID Project No. GOA16001 Orange County, Florida GEC Project No.

CEEN Geotechnical Engineering

A. Exemptions from the Geotechnical/Geological Engineering Report submittal requirements are:

RI Site Specific Soil Mapping Standards and Procedures

In preparation for constructing buildings on a property, the builder. Site Preparation CHAPTER

Geotechnical Engineering Report

University of Florida Conservation Areas Land Management Plan Trillium Slope (Golf Course Woods)

CITY OF MONTCLAIR Montclair Civic Center 5111 Benito Street Montclair, CA 91763

Earth Mechanics, Inc. Geotechnical & Earthquake Engineering


For. Report of Geotechnical Exploration. University of North Florida Parking Lot 47 Jacksonville, Florida

Water Well Report. Site Name

9. SOIL PERMEABILITY. 9.0 Why is it important to determine soil permeability?

For. Report of Geotechnical Exploration. Beaver St Lane Ave to Carnegie St Trans Water Main Project Jacksonville, FL

GEOTECHNICAL INVESTIGATION I-15 SIGN BRIDGES LAS VEGAS EA JANUARY

For. Report of Geotechnical Exploration. University of North Florida Parking Lot 11 Jacksonville, Florida

Urban Soil Conservation and Management

WETLAND DELINEATION REPORT

STORMWATER MANAGEMENT. 158 Attachment 2. Borough of Perkasie

Section 1I-3 - Bioswales

GEOTECHNICAL REPORT B-1942

Tesoro Anacortes Refinery Clean Products Upgrade Project Draft Environmental Impact Statement APPENDIX 2-D: GEOTECHNICAL DRAWINGS

Treatment Volume: Curve Numbers. Composite CN or Not? Treatment Volume: Curve Numbers. Treatment Volume: Calculation. Treatment Volume: Calculation

Differential Black Walnut Growth on a Recommended Soil Map Unit: Investigation of Related Soil Chemical and Physical Properties

Precipitation Surface Cover Topography Soil Properties

City of Dade City AMEC Project No Dade City Stormwater Master Plan September 2012 Page 11

Effect of Land Surface on Runoff Generation

Measured Water Losses of Lateral A in Hidalgo County Irrigation District No. 2

APPENDIX E. LESA Models

Infiltration Guidelines

Ponding Test Results Seepage and Total Losses, North Alamo Main Canal Hidalgo County Irrigation District No. 2

ATTACHMENT 4 USDA NRCS HYDRIC SOIL UNIT DESCRIPTIONS

Geotechnical Engineering Report

geotechnical and construction materials consultants

PARKING LOTS 4, 7, AND 8 RECONSTRUCTION REPORT

Work Plan EAS Components

GEOTECHNICAL STUDY PROPOSED CONCRETE ROADWAY TIKI ISLAND COMMUNITY GALVESTON COUNTY, TEXAS PROJECT NO E

SOIL MECHANICS Assignment #2: Soil Classification Solution.

TIERRA TIERRA, INC. November 19, TPA Group LLC 3350 Riverwood Parkway, Suite 750 Atlanta, Georgia 30339

FIRM NAME DESIGNER: CHECKER: DATE: FPID #: DESCRIPTION: COUNTY: DRAINAGE DESIGN CHECKLIST. Designers Initials. Checkers Initials.

Applied GeoScience, Inc Hammond Dr., Suite 6 Schaumburg, Illinois

PRELIMINARY ENGINEERING DESIGN MEMORANDUM WATER TREATMENT PLANT FLOOD WALL TO PROTECT BACKWASH SETTLING BASIN CITY OF NEW BUFFALO, MI

The following sections provide the approved standard infiltration testing specifications.

PHYSICAL SOIL PROPERTIES

Site Location. Figure 1: Site Location Map US-24 and I-275 Interchange Ash Township, Monroe County, Michigan

ENGINEERING SERVICES REPORT FOREST LAKES BOULEVARD PAVEMENT EVALUATION TAMPA ROAD TO COUNTY LINE FOR PINELLAS COUNTY, FL. May 21, 2010 URS CORPORATION

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

Earthen Manure Storage Seepage

File No Supplemental November Geotechnical and Environmental Consulting Engineers

GEOTECHNICAL INVESTIGATION For PROPOSED OUTDOOR THEATER 495 Upper Park Road APN Santa Cruz, California

PROJECT NO A. ISSUED: February 29, 2016

Design and Operation of Landfills

REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING SERVICES

PRELIMINARY GEOTECHNICAL INVESTIGATION UCCS PARKING GARAGE STANTON STREET AND AUSTIN BLUFFS PARKWAY COLORADO SPRINGS, COLORADO

An Explanation of the Hydric Soil Technical Standard and Normal Precipitation

Soil Compaction. By: Kelly Patches Soils 401 April 8, 2009

INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT GREENE COUNTY ASH POND ALABMA POWER COMPANY

DUCTILE IRON PILES ARE HIGHLY EFFECTIVE, FAST AND VERSATILE MODULAR DRIVEN MICROPILE SYSTEMS

Sent: Friday, June 24, :17 PM. Subject: RE: Southwood 4 - Monitoring Well update

BCOSSA Technical Review Committee Technical Bulletin

DRIP EMITTER SYSTEM STUDY GUIDE

STORMWATER HYDROLOGY

INFLOW DESIGN FLOOD CONTROL SYSTEM PLAN PLANT BARRY ASH POND ALABAMA POWER COMPANY

Standards for Soil Erosion and Sediment Control in New Jersey May 2012 STANDARD FOR GRASSED WATERWAYS. Definition. Purpose

Bioreactor Landfill Design

Characterizing Engineering Properties of Foundry Sands

4.1 General Methodology and Data Base Development

Appendix A. Infiltration and Soil Texture Testing Methods. Appendix A. A.1 General Description. A.2 Infiltration Testing: A Four-Step Process

SepticDesign.ca Gunnell Engineering Ltd.

B. Install storm drain inlet protection to prevent clogging of the stormsewer and sediment loads to downstream stormwater facilities or waterbodies.

Preliminary Geotechnical Exploration Armstrong Tract Rivers Avenue and Hanahan Road North Charleston, South Carolina S&ME Project No.

Green Station CCR Surface Impoundment Sebree Generating Station Address: 9000 Highway 2096 Robards, Kentucky 42452

U.S. Army Corps of Engineers Jacksonville District Sediment Quality Control/Quality Assurance Plan For Maintenance Dredging with Beach Placement

NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES DIVISION OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ON-SITE WATER PROTECTION BRANCH

Transcription:

PART 2D GEOTECHNICAL INVESTIGATION TO ESTIMATE AQUIFER PARAMETERS Note the word is estimate & not determine. Must appreciate the physical meaning of each aquifer parameter. Aquifer, in this sense, does not refer to the Florida aquifer but usually the uppermost sand aquifer into which the pond is excavated. This task should be conducted by an experienced geotechnical engineer. Two important references: SWFWMD Training Workshop on SHWT (1998 Edition) Section 7.2 of SJRWMD Special Publication SJ93-SP10

VISUALIZATION OF THE AQUIFER PARAMETERS

GEOTECHNICAL INVESTIGATION - STORMWATER PONDS Objective of the soils report is to provide numerical values for the following aquifer parameters: Seasonal high water table (ft NGVD) Seasonal fluctuation of water table (ft) [only for wet pond] Base of effective aquifer (ft NGVD) Weighted horizontal hydraulic conductivity of effective aquifer (ft/day) Fillable porosity Unsaturated vertical infiltration rate (ft/day) [only for dry pond where unsaturated flow is being considered] Parameters should be clearly stated in one section or in a table of the soils report. It should not be buried within the verbiage of the report.

128.0 127.0 126.0 Top of Wall E.L. 128.0 SAMPLE END RESULT OF GEOTECH INVESTIGATION 125.0 124.0 123.0 122.0 121.0 120.0 119.0 PB-1 (+123.06') (Fill) Very dark brown organic Gray Light gray (2.4') Dark reddish brown slightly silty 118.0 (5.1') 8" CMU Wall (Fill all cells with grout) ì 6" to 1' Below Grade 3'-8" 3'-0" 6" Non- Cementous Gravel Top E.L. 122.0 PB-2 (+123.4') (Fill) Dark grayish brown slightly silty with roots. Light gray fine sand (2.9') Dark reddish brown slightly silty k v = 13.4 ft/day (5.7') 117.0 116.0 Brown Brown 115.0

SAMPLE END RESULT OF GEOTECH INVESTIGATION +107' +107' +106' +105' +104' +103' +102' +101' Cross Section Along North Side of Pond Range of predevelopment grade Cross Section Along South Side of Pond West East West East HA-3 (+101.73') HA-8 (+ 101.48') HA-4 (+103.34') HA-7 (+101.73') HA-1 (+102.03') +106' +105' +104' +103' +102' +101' +100' +100' +99' +99' +98' +97' kv =28.9 ft /day HA-2 (+97.33') Ø kv =30.5 ft /day +98' +97' +96' +95' +94' +93' +92' +91' +90' +89' (7.5') HA-5 Light gray clay Light orange Terminated @ 1.0' brown clayey Light orange brown and light gray sandy clay Terminated @ 10.0' Terminated @ 10.0' (8.0') Light orange brown clayey Ø Ù (7.0') Light orange brown sandy clay Terminated @ 8.0' Pond Bottom Elevation (+93.8') Terminated @ 11.0' (5.75') Light orange brown clayey Terminated @ 7.0' (9.5') Light orange brown clayey HA-6 Light gray clay Terminated @ 1.0' Ù (11.5') Light orange brown sandy clay Terminated @ 13.0' +96' +95' +94' +93' +92' +91' +90' +89'

GEOTECHNICAL INVESTIGATION - STORMWATER PONDS Review of published data to include USGS quad map (look at lay of the land and any closed depressions, and contributing drainage basins; good practice to field verify drainage basin divides). NRCS (formerly SCS) soils map. NRCS data is now available on the internet. Aerial photos Sub regional map of potentiometric ti t i surface of Florida aquifer and compare to land surface elevation or water table elevation Map data to include Location of pond within development Location of adjacent water bodies and wetlands and their water ocat o o adjace t ate bod es a d et a ds a d t e ate elevations

REVIEW USGS QUADRANGLE MAP Drainage Basin Divide Tc flow line

REVIEW NRCS SOILS MAP SITE Legend: CaB - Candler sand, 0 to 5 % slopes

Table 3: Key SCS Characterization Data for Arredondo Sand [ArB (0-5% slopes)] This is a nearly level to sloping, well drained soil that occurs as both large and small areas in the upland. The water table is at a depth of more than 72 inches. Hydrologic Soil Group (HSG) A REPRESENTATIVE SOIL PROFILE Depth Soil Color & Texture Permeability 0-7in dark grayish brown sand 7-18 in mixed yellowish brown and dark yellowish brown sand 18-46 in yellowish brown sand 12 to 40 ft/day 46-65 in strong brown sand 65-70 in strong brown loamy sand 70-90 in strong brown y loam 4 to 12 ft/day

Minimum Requirements for Soils Reports Site-specific geotechnical data to include: Location of borings within or adjacent to pond. The geotechnical engineer should select the number of pond borings based on the size of the pond. For guidance on the number of borings, refer to page 162 of SJ93-SP10. Soil profiles with stabilized water table measurements at time of drilling Results of hydraulic conductivity tests (if performed). Report should also state type of hydraulic conductivity test performed and reference the location and depth of the test Explicit recommendations for each aquifer parameter

Estimating Aquifer Parameters Aquifer thickness: Refer to Section 7.2.1 of SJRWMD SJ93-SP10 for the recommended type and number of soil borings. Also refer to this section for how the soil profile should be interpreted. Fillable porosity: Refer to Section 7.2.4 of SJRWMD SJ93-SP10 for recommendations on how to estimate fillable porosity. Rules of thumb: 30% for HSG A, 25% for HSG B & C, and 20% for HSG D. Weighted horizontal hydraulic conductivity: Refer to Section 7.2.3 of SJRWMD SJ93-SP10 for recommended test procedures and how the weighted average should be computed. Unsaturated vertical infiltration rate: use Double Ring Infiltrometer test (described later). Apply minimum safety factor of 2 to measured rate.

Estimating Aquifer Parameters (Continued) Seasonal high water table: Refer to Section 7.2.2 of SJRWMD SJ93- SP10 for the recommended procedure. This technical procedure cross-references a paper I wrote on estimating the seasonal high water table. We will discuss this subject in some more detail in this workshop. Seasonal fluctuation of the water table: typically 3 to 4 ft in the pine flatwood soils and 6 ft or more in the sand ridge soils.

Typical Correlation Between Fines Fraction & Hydraulic Conductivity for Florida Fine Sands 1000.000 Hydraulic Conductivity (ft/day) 100.000 10.000000 1.000 0.100 0.010 Note: hydraulic conductivity also depends on cementation, color, roots, gradation, compaction, density, and other factors From Permeameter Tests on Poorly Graded Fine Sands to Silty Fine Sands in Florida 0.001 0 5 10 15 20 25 30 Percent Passing U.S. No. 200 Sieve