WTP Design by Computer. David Hayhurst, Purolite International

Similar documents
SST-60 Salt Saving Technology Softening Resin

The evolution of high purity water production

A-300, A-300E Strong Base Type II Anion Exchange Resin

A3: Contaminant Reduction, Life Cycle Impacts, and Life Cycle Costs of Ion Exchange Treatment and Regeneration

Membrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership

DOWEX Ion Exchange Resins

FEDI. Fractional Electrodeionization. The evolution of high purity water production

For the production of ultrapure water (> 18 MOhm*cm at 25 C).

Training Ion Exchanger for demineralizing. Hans-Jürgen Wedemeyer Technical Manager Liquid Purification Technologies

Lewatit A 8072 is particularly suitable for the following applications:

Use in Mixed Bed. Removal of alkaline hardness from water.

Lewatit MonoPlus M 500 OH is especially applicable for:

ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER

» cartridges for household filter systems in combination with activated carbon.

California Dreamin. on such a winter s day. The Mommas and the Papas

This document contains important information and must be read in its entirety. Edition: Previous Edition: /4

By C.F. Chubb Michaud, CWS-VI

performance of the ultrapure make-up system at Turkey Point Nuclear Power Plant

DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50%

Temperature stability of anion exchange resins

LEWATIT S 7468 PRODUCT INFORMATION

Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India - Reducing the water footprint in coal fired power plants -

NEW TECHNOLOGIES & BREAKTHROUGHS TO OLD DEIONIZATION APPLICATIONS

Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India Reducing the water footprint in coal fired power plants

PRESENTATION OF CONDENSATE TREATMENT

Lenntech. Tel Fax

SHORT BED ION EXCHANGE TECHNOLOGY PRODUCES ULTRAPURE WATER WITHOUT USING A MIXED BED

NIPPON PAPER RO SYSTEM + 2 Others

ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium

ION EXCHANGE (I) LTD 3

PRODUCT INFORMATION LEWATIT MonoPlus MP 600

Douglas Dobie Lawrence Livermore Nat l Laboratory P.O. Box 808, L-627 Livermore, CA (510)

IWC-10-XX. KEYWORDS: Produced water, ion exchange, nutshell filter

Keywords nanofiltration; capillary membrane; direct treatment; backflush; surface water.

FILMTEC Membranes System Design: Introduction

STORAGE, TRANSPORTATION AND PRECONDITIONING

ION EXCHANGE RESIN PRODUCTS AND SERVICES

Advanced Produced-Water Treatment & Reuse For Oilfields

THE FOULING OF ION EXCHANGE RESINS AND METHODS OF CLEANING APPLICATION GUIDE DISINFECTION TREA TMENT PROCEDURES IRON (AND MANGANESE) FOULING

Combinations of treatment processes for water recycling in the pulp&paper industry

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

Could you identify what caused the variation in ACSF among different water types? This seems to occur even when UVT is constant.

Troubleshooting Water Softeners. Frank DeSilva, ResinTech Inc. Portland, OR Mar 14, 2013

WRF Webcast Hexavalent Chromium Treatment with Strong Base Anion Exchange (#4488)

WRF Webcast Hexavalent Chromium Treatment Testing with New Ion Exchange Resins and Reduction/Coagulation/Microfiltration

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

IWC TECHNICAL PAPER 176

Lecture 6: Softening

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

EVALUATING NANOFILTRATION, REVERSE OSMOSIS, AND ION EXCHANGE TO MEET CONSUMPTIVE USE CONSTRAINTS AND FINISHED WATER QUALITY GOALS FOR BROWARD COUNTY

Produced Water Treatment Systems

SRI RAMAKRISHNA INSTITUTE OF TECHNOLOGY COIMBATORE First Year BE/B.TECH ( ) Engineering Chemistry- I

Applications Bulletin Product Purification Resource Recovery Pollution Control

Low Cross-linked Resin Reduces Iron, Maintains Low Reactor Water Sulfate

Lafayette College Department of Civil and Environmental Engineering

Operation of Hydranautics New ESNA Membrane at St. Lucie West, FL Softening Plant

The Town of Davie (town) operates a

Blank Optimization Using Ultrapure Water Suitable for Trace Ion Analysis.

HEAP LEACHING TECHNOLOGY Moving the frontier for treatment

R&D Quality Our manufacturing and distribution site is ISO 9001 v certified and ISO certified.

Use of Spiral Wound UF in RO Pretreatment

Operation Optimization of Condensate Polisher and Effect Analysis. on Improving Quality and Efficiency in Dingzhou Power Plant

APPLICATION GUIDE Nuclear Grade Ion Exchange Resins for Power Generation

DRINKING WATER - LAB EXPERIMENTS LAB EXPERIMENTS. Softening

Ion Exchange Chromatography. Learning Objectives:

NEXT GENERATION DOWEX MARATHON ION EXCHANGE RESINS FOR INDUSTRIAL WATER TREATMENT. Small change, big impact.

Installation and Operation Manual FIBERGLASS TWO BED DEIONIZERS. Systems Built After August 7, 2009 DB-18 DB-24 DB-30 DB-36 DB-42 DB-48

REMOVAL OF HARDNESS BY PRECIPITATION

Hydrometallurgy Applications

Novel Low Fouling Nanofiltration Membranes. Craig Bartels, PhD, Hydranautics, Oceanside, CA Warren Casey, PE, Hydranautics, Houston, TX

MPure. Innovative Electrodeionization by MEGA a.s. Czech Republic. MPure ELECTRODEIONIZATION. MPure ELECTRODEIONIZATION

5.B Generation of pharmaceutical water Author: Michael Gronwald Co-Author: Dr. Ralph Gomez / Up06

IWC ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

Chapter 7.2. AFFIRM and Alberta MMP Software. learning objectives

Hybrid RO & Softening Birjand Water Treatment Plant

Water Treatment Plant Design at the Idaho Cobalt Project

ACID SEPARATION FOR IMPURITY CONTROL AND ACID RECYCLE USING SHORT BED ION EXCHANGE

Pilot Study Report. Z-92 Uranium Treatment Process

THE USE OF SELECTIVE ION EXCHANGE FOR THE RECOVERY OF BASE METALS FROM EFFLUENT STREAMS

Sulfate Reducing Bioreactor for Sulfate, Metals and TDS Removal

DRAFT July 26, Engineer s Report Water Softening Alternatives for Boyack Road Water Treatment Plant. Town of Clifton Park, New York

Filter materials. Trickling filter material for high hydraulic loads. Filter material with very high free space

Programming Manual 85HE PROGRAM GUIDE

Demineralization (RO, NF, UF, MF, ED, IE)

Assessment of Ion Exchange, Adsorptive Media, and RCF for Cr(VI) Removal

Alternatives for addressing chloride in wastewater effluent

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent

Interpretation of Chemistry Data from Seepage, Observation Well, and Reservoir Water Samples collected at Horsetooth Dam during July 2004

DISTRIBUTION TECHNOLOGY SAVES WATER. SAVES SALT. SAVES THE ENVIRONMENT. Where Innovation Flows

Treatment Technologies

Geology 627, Hydrogeology Review questions for final exam h t 1/ 2

Wolf Laboratories Limited

NACE CORROSION 2008 TEG 096X Symposia - Paper 1421

Nadeem Shakir Qatar Petroleum. The 2nd Joint Qatar Japan Environmental Symposium, QP JCCP The 21st Joint GCC Japan Environmental Symposium

Ion Exchange Chromatography Media. Cellufine IEX. Technical Data Sheet

Nitrate and Perchlorate Removal from Groundwater by Ion Exchange

How to Choose a Water Softener. Brought to you by

Ferrolox. Arsenic Removal: Part I. By Deepak Chopra. Technology with increasing demand. July 2013

Hardness Removal from Groundwater by Synthetic Resin from Waste Plastics

Transcription:

WTP Design by Computer David Hayhurst, Purolite International

Presentation Content Design brief + influent water Ground rules + introduction to the software Water analysis Plant layout Treated water specification The design Resin choice and design margin Flow rate and cycle time Optimising rinse volumes and regeneration levels Vessel sizing Adjusting for neutral effluent Outputs Other design options + OPEX comparison

Design Brief Client requires demineralised water sourced from deep borehole. Plant design requirements are for 80 m3/h flow. Operators work an 8 hour shift pattern. Proposed option is counter-current packed bed SAC degasser SBA with separate polishing MB Outline treated water specification is: Conductivity (µscm -1 ) Silica (ppb) Average 1 20 End point 2 50

Influent Water Cations (ppm CaCO 3 ) Anions (ppm CaCO 3 ) Other info Ca 2+ : 200 HCO 3- : 150 SiO 2 (reactive): 10 ppm Mg 2+ : 75 Cl - : 50 TOC: 0.1 ppm Na + : 50 NO 3- : 30 ph: 7.2 K + : 5 SO 2-4 : 100 EC: 430 µscm -1 Fe 3+ : 0.1 Total Cations: 330.1 Total Anions: 330

Ground Rules Plant Design SAC WBA For partially demineralised water 10 30 µscm -1 spec. SAC SBA Most common combination can incorporate DG SAC WBA - SBA WAC SAC - WBA WAC SAC SBA WAC SAC WBA SBA More complex, higher CAPEX systems but lower OPEX due to higher regeneration efficiency of WAC/WBA when high EMA Resin can be housed in separate vessels or layered in the same vessel Degasser commonly used when alkalinity > 1 meq/l (50 ppm as CaCO 3 ) DG located before WBA for acrylic WBAS, and after for polystyrenic WBAs

Ground Rules Resin Choice / Grade Anion resin selection: Reactive silica level T1 sty/acr > T2 sty/bif. Operating (working) capacity Bif > T2 sty > acr > T1 sty Operating flow rate (BV/h) poss. acr bead deformation Organics load Acr/bif > T1 sty > T2 sty Operating temperature T1 sty >T2 sty> bif. > acr Cation resin selection: Usually 8 % xlinked gel SAC, either in Na or H form. Macro resins usually used only in demanding conditions WAC/WBA resins Used in separate vessels or in layered (stratified) beds Std + graded products available Acr WAC, both sty+acr WBA available Resin grades: Standard or Purofine for co-flow Puropack for counter-flow DL for stratified beds

Ground Rules Regeneration WAC / SAC HCl or H 2 SO 4 Note Puredesign assumes 2-step regeneration with H 2 SO 4 + displays average acid strength if single addn., add 5 % to design margin WBA / SBA - NaOH Minimum level of 65 g/l for organic fouling waters Options include co or counter flow regeneration, backwashed or packed bed Standard rinses: co-flow 2 BV slow, 4-6 BV fast counter-flow 2 BV slow, 2BV fast for cation, 3-4 BV fast for anion Neutral effluent achievable by balancing regen levels

Introduction to the Software Provides theoretical model of plant Enables optimisation of equipment, service and regeneration conditions for given raw water and treated water specification Allows system modification to mimic the effects of changed raw water/treated water specification

Introduction to the Software

Choice of process options available from softening through to nitrate removal Introduction to the Software

Introduction to the Software Choice of process options available from softening through to nitrate removal Water analysis option allow for both manual entry and load from memory to facilitate multiple iterations of design

Water Analysis On Screen

Water Analysis On Screen Several units available when entering water analysis, standardisable with set all ions to button

Water Analysis On Screen Note water temperature assumed for deep borehole Several units available when entering water analysis, standardisable with set all ions to button

Plant Layout

Plant Layout Plant layout can be specified with regard to CAPEX vs OPEX and treated water requirements

Plant Layout Plant layout can be specified with regard to CAPEX vs OPEX and treated water requirements Define presence and location of any degasser

Plant Layout Plant layout can be specified with regard to CAPEX vs OPEX and treated water requirements Specify regeneration mode allocates resin choices and working capacities Define presence and location of any degasser

Plant Layout Plant layout can be specified with regard to CAPEX vs OPEX and treated water requirements Specify regeneration mode allocates resin choices and working capacities Define presence and location of any degasser Rinse options factor gross water requirements dependant on preferred source

Treated Water Specification

The Design

The Design Resin Choice and Design Margin

The Design Resin Choice and Design Margin Select resin choice based on raw water constituents and operating temperature

The Design Resin Choice and Design Margin Select resin choice based on raw water constituents and operating temperature Specify design margin for each bed note lower cation margin

The Design Flow Rate and Cycle Time

The Design Flow Rate and Cycle Time Introducing a cycle time generates a basic model with a series of default set points

The Design Flow Rate and Cycle Time

The Design Flow Rate and Cycle Time A warning! There are various hard and soft limits built into the program. We would suggest increasing design margin if these warnings are overridden, as the program assumes operation within defined parameters

The Design Flow Rate and Cycle Time

The Design Optimising Rinse Volumes and Regeneration Levels

The Design Optimising Rinse Volumes and Regeneration Levels Typical rinse volumes for counter-flow systems

The Design Optimising Rinse Volumes and Regeneration Levels

The Design Optimising Rinse Volumes and Regeneration Levels Regen. levels set to give approximately neutral effluent and manage the small quantity of organics in the influent water

The Design Optimising Rinse Volumes and Regeneration Levels Note temperature adjustment on anion default is 25 ºC not likely from deep borehole in UK Regen. levels set to give approximately neutral effluent and manage the small quantity of organics in the influent water

The Design Vessel Sizing Plant currently modeled assuming metric measurements In practice, vessels often sized on imperial measurements To minimise CAPEX, there is often merit in reducing vessel diameter, whilst factoring effect on bed depth and pressure drop Vessel dimensions influence distribution/flow and thus performance Watch out for changes to effluent levels if attempting to achieve neutral effluent!

The Design Vessel Sizing

The Design Vessel Sizing Switching vessel rounding to none enables metric or imperial values

The Design Vessel Sizing Switching vessel rounding to none enables metric or imperial values Adjusting vessel diameter to 6 increases bed depth, velocity and pressure drop

The Design Vessel Sizing Switching vessel rounding to none enables metric or imperial values Resin volumes and consequently excess regenerant to drain also affected Adjusting vessel diameter to 6 increases bed depth, velocity and pressure drop

The Design Adjusting for Neutral Effluent

Outputs

Outputs Design generated in MS Word, e.g. here

Other Design Options Stratified Bed

OPEX Comparison Packed Bed vs Stratified Bed Operating costs per m 3 treated water produced: Counter current packed bed SAC DG SBA - 0.38 Stratified WAC - SAC DG WBA SBA - 0.24 Approximate 37 % reduction in cost Costs based on chemical cost of 105/T of 32% HCl and 260/T of 46% NaOH Information for costing kindly provided by

Questions?