Installation and Operation Manual FIBERGLASS TWO BED DEIONIZERS. Systems Built After August 7, 2009 DB-18 DB-24 DB-30 DB-36 DB-42 DB-48

Size: px
Start display at page:

Download "Installation and Operation Manual FIBERGLASS TWO BED DEIONIZERS. Systems Built After August 7, 2009 DB-18 DB-24 DB-30 DB-36 DB-42 DB-48"

Transcription

1 FIBERGLASS TWO BED DEIONIZERS Systems Built After August 7, 2009 DB-18 DB-24 DB-30 DB-36 DB-42 DB-48 Installation and Operation Manual Form # FRP

2 2

3 TABLE OF CONTENTS OPERATING DATA Strong Base Deionizer Specifications. 6 PRE-INSTALLATION DATA Operating Parameters... 7 Components of a Deionizer 8 DEIONIZATION PROCESS Deionization. 9 Regeneration.. 10 Resin Types and Uses.. 10 Performance Characteristics 11 INSTALLATION Locating the Equipment.. 12 Assembly of the Deionizer.. 12 Resin Quantity.. 13 Minimum Draw Rates.. 13 Typical Installation 14 Solid State Control Panel. 15 Pneumatic Diaphragm Valve Location.. 16 Valve Sequence Chart. 16 Pneumatic Tubing Diagram. 17 REGENERATION CYCLES Service.. 18 Cation Backwash Cycle. 19 Acid Draw Cycle.. 20 Cation Rinse Cycle.. 21 Anion Backwash Cycle 22 Caustic Draw Cycle. 23 Anion Rinse Cycle 24 Purge Cycle (Rinse to Quality).. 25 CHEMICAL USAGE and TIME CYCLES Regeneration Time Cycles.. 26 Regeneration Chemical Requirements. 26 3

4 TABLE OF CONTENTS CONTROL PROGRAMMING Control Features 27 Modes of Operation 27 Regeneration Times.. 29 Control Wiring Connections.. 30 Conductivity Meter Instructions 31 TECHNICAL DATA Operating Check List. 33 Meaning of ph 34 Quality of Water. 34 Testing Hardness of Decationized Water.. 35 Double Regenerating the Cation Resin. 35 Remove of Hardness from Anion Resin. 35 Removal of Organics from Anion Resin. 36 REGENERANT SPECIFICATIONS Hydrochloric Acid 37 Sodium Hydroxide.. 38 Conversion Chart 39 Regenerant Usage Form.. 40 MAJOR PARTS and REBUILD KITS Plumbing Parts Tank Internal Distribution. 43 Plastic Diaphragm Valve Rebuild Kits. 43 Control Panel.. 44 ROUTINE and PREVENTIVE MAINTENANCE 46 TROUBLE SHOOTING GUIDE. 47 OPTIONS and ACCESSORIES. 48 Vacuum Protection 48 Recirculation Pump.. 48 Alternate Water Source 48 Skid Mounting. 48 Drum Heater 49 Liquid Level Monitor.. 49 NOTES 50 4

5 OPERATING DATA Complete the following for future reference upon start-up, it is essential that this information be made available whenever factory technical assistance is requested. Deionizer Model: Single Duplex Type of Resins: Cation Anion Quantity of Resin: Cation ft 3 Anion ft 3 Date Installed: Shipping Order No. DI water used for: Gallons per Day: Flow Rate: min max Ecodyne Industrial Water Analysis No. used to size system: Ecodyne Industrial Water Analysis Data: Total Cations ppm Total Anions ppm Cation Capacity grains Anion Capacity grains ph of water Silica ppm Maximum Water Quality based on sodium leakage ohms Mode of Operation: Quality Controlled Manual Controlled Series Regeneration Parallel Regeneration Type of Pretreatment being used Regeneration Time Settings: CATION ANION Regen Cycle Time Regen Cycle Time Backwash Acid Draw Rinse Purge Prior Rinse Regenerant Chemical used per Regeneration: Backwash Caustic Draw Rinse Chemical Acid Caustic Gallons Specific Gravity Percentage Limit Point Setting: Ohms Note: Caustic Soda must have the temperature maintained between 75 O F and 90 O F. A heat belt or other heating system is recommended for consistent service runs and silica removal from the resin during regeneration. 5

6 DEIONIZER SPECIFICATIONS STRONG BASE SYSTEMS MODEL DB-18 DB-24 DB-30 DB-36 DB-42 DB-48 Service Flow Rate Minimum GPM LPM Nominal PSI Drop KPS Drop Nominal Capacity Grains Grams Resin Volume FT 3 Liters ,000 6,500 Cation/Anion 5 / / ,000 12,900 Cation/Anion 10 / / ,000 19,400 Cation/Anion 15 / / ,000 25,900 Cation/Anion 20 / / ,000 38,800 Cation/Anion 30 / / ,800 Cation/Anion 40 / / 1132 Inlet Pipe Size Drain(s) Size Freeboard inches mm Temperature O F O C Inlet Pressure PSI kpa Power Space Req d Inches mm Shipping Weight Lbs kg Operating Weight Lbs kg Tank Sizes (DXH) Inches mm Cation/Anion 20 / / x X x x 2057 Cation/Anion 17 / / x X x x 2134 Cation/Anion 18 / / 457 Min / Max 45 / / 38 Min / Max 50 / / 691 Cation/Anion 15 / / VAC / 60 Hz 100 VA 84 x X x x x X x x 2134 NOTE: All dimensions are approximate and subject to change without notice. Cation/Anion 16 / / x X x x 2210 Cation/Anion 14 / / x X x x

7 PRE-INSTALLATION DATA Read the entire instruction manual before you begin installation. Failure to install and operate the system as required will void the warranty. The system will perform at maximum efficiency, when installed and operated as designed. Obtain all the materials and tools needed for the installation before beginning. Always use the correct tools to install and maintain the system. The installation must conform to local plumbing and electrical codes. Code compliance is the responsibility of the installer or contractor. OPERATING PARAMETERS Parameter Minimum Maximum Hardness Grains per gallon Iron (Ferrous) - 10 ppm Iron (Ferric) - 5 ppm Flow Rate 0.5 gpm / ft gpm / ft 3 Chlorine ppm Turbidity - 5 NTU Water Pressure 40 psi 100 psi * Water Temperature 35 O F 100 O F *** ph * Maximum pressure dependent on components. *** Higher temperature systems available on special order consult factory. Protect the system from pressure extremes. Do not expose the system to surging pressures or water hammer. Water hammer will cause damage to the control valves, mineral tanks, and plumbing. If a condition of this type exists, a Water Hammer Arrestor must be installed to prevent damage. Protect the system against backpressure caused by a pump or any type of water storage system. If pressure on outlet exceeds inlet pressure, resin can be flushed into the inlet water supply during the service cycle. When routing the outlet piping to an atmospheric storage tank, a valve or flow control must be installed in the outlet piping to prevent over running of the system. A backpressure of 15 to 20 psi should be maintained on the system during service. Protect the system from freezing weather conditions. Temperatures at and below freezing will cause damage to tanks, valves and plumbing. Water expands when it freezes and can cause the tanks and plumbing to burst. Protect the system from high temperatures in excess of 100 O F. Some of the components used in the manufacture of the system will not withstand high temperatures. Do not connect the system down stream of a hot water system. Also protect the outlet of the system from backup of hot water from a water heater or boiler. 7

8 PRE-INSTALLATION DATA The system operates on 24 Volts AC supplied from a step down transformer using 120 Volts on the primary side. The 120 volts operates from a normal 15 amp wall outlet receptacle, which is properly grounded. The power reduction transformer supplied with the equipment is UL listed. Conformance to local and National Electrical Codes must be observed and are the responsibility of the installer. The system must be located within 10 feet of an open floor drain or sump, which is connected to a neutralization or other waste treatment system. The drains from the system must contain vents, in accordance with the local plumbing codes. The flow of drain water should be observable. Water deionizers use an eduction system to draw the chemical into the mineral tank. Back-pressure from overhead drain systems can affect the draw rate of the deionizer, therefore; it is not recommended to run the drains any higher that 8 feet above the eductor assembly. On overhead drains, an air gap must be installed in the highest point of the drain line, and local plumbing codes and regulations should be followed. It is recommended that inlet and outlet valves be installed on the unit for future service ability. The inlet and outlet valves are utilized to turn off the water to the unit so that the valves and other components can be serviced. Threading compounds and other contaminating materials from the installation of the piping; must be flushed from the piping prior to allowing water to enter the system. These foreign materials can cause damage to the valves. COMPONENTS OF A TWO-BED DEIONIZER The system normally is not assembled at the factory. The following should be used as a reference for the correct parts against what was received. Different size units have different quantities of the media and style of internal distributors. All systems 21 through 48 have hub radial lower distributor systems. 2 Mineral Tanks (Cation and Anion) with internals installed Valve Harness Assembly (includes Failsafe and Purge Valves) Controller with Quality Monitor Strong Acid Cation Exchanger Resin Strong Base Type-2 Anion Exchanger Resin or Weak Base Anion Resin Gravel Underbedding 2 Draw Tube Assemblies Optional Recirculation Pump (required on duplex systems) The standard conductivity cell is assembled in the main piping. Special cells are shipped loose for assembly into the piping in the field. Chemical can be drawn directly out of 50-gallon drums if desired. 42 and 48 systems require larger drawtube assemblies because of the quantities of chemical used for regeneration. Skid mounting and pre-assembly is an available option from the factory. 8

9 DEIONIZATION PROCESS THE PROCESS OF DEIONIZATION Deionization or demineralization is the process of removing up to 95% of the dissolved minerals such as calcium, magnesium, sodium, manganese, sulfates, chlorides, nitrates and silica from the water supply by way of ion exchange. Dissolved minerals in the water consist of two parts a metallic part which is a positively charged ion and a non-metallic part which is a negatively charged ion. Two separate resins are utilized for the Deionization process, the cation resin exchanges the positive ions for hydrogen ions (H + ) while the anion resin exchanges the negative ions for hydroxide ions (OH - ). The Cation Resin is regenerated with Hydrochloric Acid (HCl) and the Anion Resin is regenerated with Sodium Hydroxide (NaOH) also know as caustic soda. CATION ANION Cations: Ammonium (NH 4 ) + Sodium (Na) + Potassium (K) + Magnesium (Mg) ++ Calcium (Ca) ++ Ferrous Iron (Fe) ++ Copper (Cu) ++ Zinc (Zn) ++ Aluminum (Al) +++ Chrome (Cr) +++ Ferric Iron (Fe) +++ Anions: Chloride (Cl) - Bicarbonate (HCO 3 ) - Nitrate (NO 3 ) - Bisulfate (HSO 4 ) - Carbonate (CO 3 ) - Silicate (SiO 3 ) - Sulfate (SO 4 ) - Carbon Dioxide (CO 2 ) Silica (SiO 2 ) Hydroxide (OH) - Hydrogen (H) + H 2 O The raw water enters the top of the first column and flows down through the resin. The Cationic part of the dissolved minerals in the raw water is exchanged for Hydrogen (H) + as the water passes through the Cation Resin. The water then flows out the bottom of the first column and into the top of the second column and flows down through the Anion Resin. The Anionic part of the dissolved minerals is exchanged for Hydroxide (OH) - as the water passes through the Anion Resin. Since the Cations were exchanged for Hydrogen and the Anions were exchanged for Hydroxide, the water exiting the bottom of the Anion Column is pure H 2 O with most of the minerals removed. Cation and Anion resins like certain ions better than others, this phenomenon is called the resin s affinities. The chart to the right shows the Strong Acid Cation Resin Affinities and the Strong Base Anion Affinities Cation Affinities Aluminum Iron Calcium Magnesium Potassium Sodium Anion Affinities Sulfate Carbonate Nitrate Chloride Bicarbonate Silica 9

10 DEIONIZATION PROCESS REGENERATION Hydrogen rich acid passes down through the Cation resin bed during the regeneration cycle. The other positively charged ions (calcium, magnesium, sodium, etc.) are forced off the resin and are replaced with hydrogen ions. These hydrogen ions attach themselves to the negatively charged sites on the resin beads. Hydroxide rich caustic soda passes down through the Anion resin bed during the regeneration cycle. The other negatively charged ions (sulfate, chlorides, carbonate, etc.) are forced off the resin and are replaced with hydroxide ions. These hydroxide ions attach themselves to the positively charged sites on the resin beads. Two-bed deionizers can be regenerated in sequence or simultaneously. Sequential Regeneration is the process by which the Cation Resin is backwashed, injected with chemical, then rinsed then, the Anion is backwash, injected with chemical, and rinsed, one followed by the other. Simultaneous Regeneration has both the Cation and Anion going through the regeneration cycles at the same time. Soft or De-cationized water must be supplied to the Anion Column during Simultaneous Regeneration. The hardness in the raw water can foul the Anion Resin, so it must be removed prior to entering the Anion Column. RESIN TYPES and USES Ecodyne Industrial s Deionizers are supplied with Strong Acid Cation Resin and Type II Strong Base Anion resin or Weak Base Anion resin. Strong Acid Cation Resin is especially suited for the cation removal in high purity water demineralization. This resin possesses high exchange capacity combined with excellent chemical and physical stability under a wide range of operating conditions. Used in both Two Bed Deionizer and Mixed Bed Deionizer applications. Weak Base Anion Resin is used when carbon dioxide or silica is not required to be removed from the water. Weak base resins are generally higher in acid-removing capacity than strong base resins and are generally more stable at higher temperatures. Used primarily in Two-Bed Deionizer applications. Type II Strong Base Anion Resin removes mineral acids efficiently, and is stable at temperatures up to 105 O F. Used primarily in Two-Bed Deionizer applications. 10

11 DEIONIZATION PROCESS DEIONIZER PERFORMANCE CHARACTERISTICS Two-Bed Deionizers normally produce water in the 10,000 ohms to 200,000 ohms range. The quality of water capable of being produced by the deionizer is directly related to the amount of sodium leakage from the Cation column and the Type of Anion Resin being used. The lower the sodium leakage, the higher the quality produced. Example: 1.0-ppm sodium leakage will provide 200,000 ohms from a Strong Base Anion Resin, but 400,000 ohms from a Weak Base Anion Resin. While 2.0-ppm sodium leakage will only yield 100,000 ohms from the strong base and 200,000 ohms from the weak base. The sodium leakage from the Cation column also directly affects the ph of the product water and is one of the factors in determining the amount of silica leakage from a strong base anion resin. The capacity of the cation resin is determined by three factors: the regenerant level (lbs of acid per ft 3 ), and the content of Sodium and Alkalinity in the raw water. At a Hydrochloric Acid dosage of 6 lbs per ft 3, 30% Sodium and 50% Alkalinity, the Cation Capacity will be approximately 23,500 grains per ft 3. However, on the same raw water (30% Sodium and 50% Alkalinity), by increasing the Acid dosage to 9 lbs per ft 3, the capacity will be increased by 10% to 26,000 grains per ft 3. The capacity of the strong base anion resin is actually determined by four factors: the regenerant level (lbs of sodium hydroxide per ft 3 ), and the content of Monovalent Ions, Carbonic Acid, and Silica in the raw water. At a Sodium Hydroxide dosage of 6 lbs per ft 3, 25% Monovalent ions, 10% Carbonic Acid, and 5% Silica, the Strong Base Anion Capacity is 16,000 grains per ft 3. If Silica increases to 10%, the capacity decreases to 15,700 grains per ft 3. The capacity of the Anion Resin normally dictates the service run length of the deionizer. The Cation resin usually has more capacity than the Anion. Normally a two-bed deionizer comes with a Cation and an Anion that have the same physical size and quantity of resin. The extra capacity of the Cation can be used to regenerate the Anion in systems using sequential regeneration. During normal operation of a two-bed deionizer, after completion of regeneration, the system rinses to a pre-determined quality (usually 50,000 ohms). During operation the quality will continue to climb until the maximum quality is reached. The Sodium Leakage from the Cation resin as previously noted determines the maximum quality of water. The dumping of Silica, followed by Bicarbonates and Chlorides, indicates the end of the service run. A silica monitor is required if one of the critical factors of operation is silica removal. The ph will drop below 7.0 as the Chlorides start to come through to service. The Chloride leakage can be determined by monitoring the ph of Water Quality Peak Quality Length of Service Run the product water. The graph depicts the normal performance curve for a two-bed deionizer. Notice that the quality will increase slightly just before the end of the run. The water quality will drop until the pre-determined set point is reached, then regeneration is required. 11

12 DEIONIZER INSTALLATION LOCATING THE EQUIPMENT Locate the mineral tanks on a firm foundation preferably concrete. The system should be located near an electrical outlet. The electrical panel must be supplied with a 120 volt 20 amp circuit. Power for the recirculation pump must be run separately. A floor drain to a central waste treatment system should be available near the installation, or a neutralization system installed for the Deionizer. Local plumbing codes apply and special requirements may need to be met when installing the system. ASSEMBLY OF THE DEIONIZER The system is not assembled when shipped. The two tanks are set in place and the piping built to the specific tanks shipped with it. The distribution system is mounted in each tank and shipped assembled inside it. Once the system is built and tested with the control panel, the piping is removed and packaged to prevent damage. The piping will have to be reassembled to the two tanks at jobsite. An option offered is skid mounted and pre-piped. The tanks, piping and Controls are pre-assembled and shipped complete if this option is purchased. Assembly is not required on these systems. Check the system for broken parts or damage that may have occurred during shipment. Damage during shipment is considered freight damage and a freight claim should be filed with the freight lines. New parts must be ordered to fix the damaged ones. Check the internal distribution system for damage or broken parts. Do not load resin or gravel if parts are of questionable integrity. Once the tanks are located and the piping assembled to them, connect the inlet water supply, process water piping and drain lines as shown on the installation drawings that follow. Be sure to install isolation valves on the inlet and outlet of each system. Flush all lines of debris after completing the installation. Connect the drawtube assemblies to the draw connection using the chemical hose provided. The drawtubes are made to be placed in a 50-gallon drum. The chemical can be drawn directly from its container. The chemical is drawn into the deionizer system. Therefore, it is critical that the system be supplied with 40 psi of water pressure. Lower pressures provide lower vacuums and the caustic viscosity may not allow the system to draw the proper amount in the proper time. Drain lines must be ran a minimum of 3 feet over head to prevent a siphoning action on the chemical drums. A maximum height of 8 feet is also required because of the vacuum requirements. Overhead drains provide backpressure on the system reducing the vacuum created by the injector. The system reacts the same as if it did not have enough water pressure. Locate the control panel as shown on page 15. The control may also be wall mounted. The system is equipped with diaphragm valves that are operated with 4-way solenoid valves using air pressure. The air pressure must be 10 psi greater than the water pressure for proper operation of the diaphragm valves. Connect tubing from diaphragm valves to the appropriate 4-way solenoid valve port. Refer to the tubing diagram for proper connections. 12

13 DEIONIZER INSTALLATION Load the resin and gravel into the mineral tanks through the top opening. o Place approximately 12 of water in each tank. o Load gravel and level with a piece of plastic pipe careful not to damage tank. o Load the resin Cation is on the left and Anion is on the right. o Fill the tank with water and replace upper baffle. Refer to the following chart for the amount of resin and gravel included with each deionizer. Model Cation Resin Quantity (ft 3 ) Anion Resin Quantity (ft 3 ) Gravel Qty. per Tank (lbs) DB DB DB DB DB DB Slowly pressurize system and check for leaks. If leaks are found repair as needed. Check the draw rates by placing the drawtubes in a 5-gallon bucket of water and advancing the control to acid draw cycle. Check the draw rate per the instructions below. When finished, advance the control to caustic draw cycle and check the draw rate. When drawing water the draw rates should be the same, because the eductors are the same. If the draw rates are not the same, then corrections need to be made. The chart below gives the minimum draw rate based on water, chemical has a different higher specific gravity so the draw rates will be less than those shown in the chart. Tank Diameter Minimum Draw Rate INSTRUCTIONS: Measure the length of time to draw a gallon of water. If you divide this time into 1 gallon, you will get gallons per minute. Example 1: If it takes 30 seconds to draw 1 gallon of water (30 seconds / 60 seconds per minute = 0.5 minutes) then, 1 gallon / 0.5 minutes = 2 gpm. Example 2: If it takes 45 seconds (45 seconds / 60 seconds per minute =.75 minutes) then, 1 gallon /.75 minutes = 1.33 gpm. 13

14 DEIONIZER INSTALLATION DEIONIZER TYPICAL INSTALLATION Deionizers produce low Total Dissolved Solids (TDS) water usually in the 20,000 to 50,000 ohm range, which means the water is aggressive and wants to dissolve any material with which it comes in contact. Drain lines, and product lines must be made of corrosion resistant materials, such as PVC, CPVC, or stainless steel. The deionizer has an inlet, an outlet, and three drain lines. It is recommended that manual valves be installed on the inlet and outlet of the system for servicing. The Cation drain will transport waste acid, the Anion drain will transport waste caustic soda, and the Purge drain will transport low quality waste deionized water. Water used during the regeneration process must be neutralized prior to dumping down a standard floor drain. This is governed by local plumbing codes. The drain lines must be ran separately to the neutralization system; do not combine into one pipe. The maximum recommended height for the drain lines is 8 feet above eductor and the minimum height is 3 feet above the eductor. When using a recirculation pump, installation of a check valve on the inlet of the DI is required to prevent deionized water, acid or caustic from being fed into the incoming lines. The recirculation pump comes with a flow meter, check valve, hose and all necessary fittings to install the unit as shown above. 14

15 DEIONIZER INSTALLATION SOLID STATE CONTROL PANEL The CQ control is a fully automatic, completely programmable solid-state control for unattended operation of a two-bed Deionizer. The controller has a built-in conductivity meter which constantly monitors water quality, and can initiate a regeneration when quality drops to a pre-set point. The conductivity meter is capable of being set between 0 and 200 us/cm. The set point selector allows the user to program a minimum quality level. Above the set point an indicator light glows green, while below the set point an indicator light glows orange / yellow. The control will automatically initiate a regeneration when the quality drops below the pre-set limit. Purge prior to regeneration may be selected as an option on single systems. Regeneration may also be initiated based on ph limit, time, volume of water used, or a combination of these. Two controls may be easily connected together forming a duplex system that automatically removes the exhausted DI train from service, puts the stand-by Deionizer on line, and initiates a regeneration of the exhausted system. The CQ control can be programmed to start a regeneration automatically or to sound an alarm for operator inspection before release of the regeneration sequence. Regeneration of cation and anion vessels can be sequential or simultaneous 1. All regeneration timing steps for the cation and the anion are controlled separately from individual switch inputs for flexibility and assured program integrity. The controls graphic faceplate displays a schematic of the deionizer system for quick operator reference. The display clearly shows whether the deionizer is in service or regeneration, and also shows the regeneration cycles for each vessel. It also provides indicator lights for failsafe valve status, and operation of the optional recirculation pump and regenerant waste holding tank. The control is housed in a plastic corrosion resistant enclosure with sealed electrical connections for maximum reliability. The control comes with a rechargeable battery back up, and operated on low voltage for ease of maintenance and operator safety. A standard 120-volt power source from a 15-amp or 20-amp circuit dedicated to the Deionizer will provide the power required to operation. Black poly tubing is supplied for connecting the diaphragm valves to the 4-way solenoids. A gang-mounted bank of 4-way solenoids pilot operate the diaphragm valves on the system. They are also used to pilot operate air operated Ball Valves or Butterfly Valves on the larger systems. Connect tubing as shown in the Tubing Diagram. 1 Simultaneous regeneration requires a softener or lone cation to provide water for the anion column. Consult factory. 15

16 DEIONIZER INSTALLATION PNEUMATIC DIAPHRAGM VALVE LOCATION VALVE SEQUENCE CHART CYCLE CATION ANION C1 C3 C4 C5 C6 C7 A1 A2 A3 A4 A5 A6 A7 A8 Service O O O Cation Backwash O O O Acid Draw O O O O Cation Rinse O O O Anion Backwash O O O Caustic Draw O O O O Anion Rinse O O O Quality Purge O O O O designates valve is OPEN 16

17 DEIONIZER INSTALLATION PNEUMATIC TUBING DIAGRAM 17

18 REGENERATION CYCLES SERVICE CYCLE The deionizer produces quality water during the Service Cycle. Water flows into the cation tank through the Cation Inlet Valve (C1). The water then passes through the cation resin and the cation exchange takes place. The decationized water flows into the distributors and out the bottom of the tank. The decationized water enters the anion tank through the Anion Inlet Valve (A1). The anions are removed as the water flows down through the anion resin. The deionized water is collected at the bottom of the anion tank and flows out to process through the Failsafe Valve (A2). The recirculation pump is operational during the Service Cycle. If water is not being drawn from the system, the pump will re-circulate the water from the outlet of the Anion to the Inlet of the Cation, and quality will be maintained. If there is no movement of water during periods of no use, the quality will drop causing a pre-mature regeneration to be initiated. Check valves are supplied with the recirculation pumps. 18

19 REGENERATION CYCLES CATION BACKWASH CYCLE The Failsafe Valve (A2) is closed preventing water and/or chemical from being accidentally sent to the process. The first regeneration cycle (series regeneration) is the Cation Backwash Cycle. The Cation Inlet Valve (C1) is closed, and the inlet raw water is directed to the bottom of the Cation Column through the Cation Backwash Inlet Valve (C3). The water flows out through the distributors and up through the cation bed providing for at least 50% expansion of the resin. The water then flows out through the top collector to drain through the Cation Backwash Outlet Valve (C4) and the Backwash Flow Control. The Backwash time is usually 10 minutes. It takes approximately 6 of those minutes be fore the resin has reached full expansion. The backwash cycle flushes the particulate matter collected during the service cycle down the drain, and prepares the cation resin for the introduction of the acid regenerant. 19

20 REGENERATION CYCLES ACID DRAW CYCLE Valves C3 (Backwash Inlet) and C4 (Backwash Outlet) are now closed. The Cation Eductor Inlet Valve (C6), Rinse Outlet Valve (C5), and the Acid Valve (C7) are opened. Water enters through Valve C6, flows through the eductor, which creates a vacuum and draws the acid through Valve C7 from the chemical container. The mixture of acid and water (normally 6%) is directed to the top of the resin bed. The Acid flows down through the bed removing the Cations collected during Service Cycle. The excess acid and the waste cations exit the Cation Column and flow through Valve C5 to Drain. This drain water is acidic (low ph) and must be neutralized prior to sending it to the city sewage system. The percentage of the acid can be adjusted with use of the metering valve just below Valve C7. Samples of the diluted acid are taken at the test cock above the eductor. The specific gravity of the solution is used to determine the percentage of acid. Refer to the specific gravity chart contained in the Regenerant Specifications section. 20

21 REGENERATION CYCLES CATION RINSE CYCLE The Acid Valve (C7) is closed, stopping the flow of acid. The Cation Eductor Inlet Valve (C6) and the Rinse Outlet Valve (C5) remain open allowing water to flow down through the resin rinsing away the excess acid and remaining cations. This water takes the same path as in the previous cycle. The rinse is complete when the ph of the water exiting to drain is between 2.5 and 3.0 and the Hardness is 0 grains. Samples can be taken at the test cock just below the Rinse Outlet Valve (C5). This test cock can also be used to tell when the acid breaks through the bottom of the resin bed. When Rinse is complete, the Cation Column returns to the Service Cycle. Water flows into the Cation Column through Valve C1, and out the bottom over to the Anion Column. The Anion will start the Backwash Cycle. 21

22 REGENERATION CYCLES ANION BACKWASH CYCLE The Anion Column uses decationized water for regeneration, and is supplied by the Cation Column. When Simultaneous Regeneration desired, the Anion Column must be supplied with a separate source Soft Water Supply or Decationized Water Supply. The Anion Inlet Valve (A1) is closed and the Backwash Inlet Valve (A3) and the Backwash Outlet Valve (A4) are opened. The decationized water is directed to the bottom of the Anion Column through the Anion Backwash Inlet Valve (A3). The water flows out through the distributors and up through the anion bed providing for at least 50% expansion of the resin. The water then flows out through the top collector to drain through the Anion Backwash Outlet Valve (A4) and the Backwash Flow Control. The Backwash time is usually 10 minutes. It takes approximately 6 of those minutes before the resin has reached full expansion. The backwash cycle flushes the particulate matter collected during the service cycle down the drain, and prepares the anion resin for the introduction of the sodium hydroxide regenerant. 22

23 REGENERATION CYCLES CAUSTIC DRAW CYCLE Valves A3 (Backwash Inlet) and A4 (Backwash Outlet) are now closed. The Anion Eductor Inlet Valve (A6), Rinse Outlet Valve (A5), and the Caustic Valve (A7) are opened. Water enters through Valve A6, flows through the eductor, which creates a vacuum and draws the caustic through Valve A7 from the chemical container. The mixture of caustic and water (normally 4-6%) is directed to the top of the resin bed. The Caustic flows down through the bed removing the Anions collected during Service Cycle. The excess caustic and the waste anions exit the Anion Column and flow through Valve A5 to Drain. This drain water is caustic (high ph) and must be neutralized prior to sending it to the city sewage system. The percentage of the caustic can be adjusted with use of the metering valve just below Valve A7. Samples of the diluted caustic are taken at the test cock above the eductor. The specific gravity of the solution is used to determine the percentage of caustic. Refer to the specific gravity chart contained in the Regenerant Specifications section. The Anion Resin will also remove hardness from the water, but it can not be regenerated off the resin with Sodium Hydroxide (Caustic Soda). 23

24 REGENERATION CYCLES ANION RINSE CYCLE The Caustic Valve (A7) is closed, stopping the flow of Sodium Hydroxide. The Anion Eductor Inlet Valve (A6) and the Rinse Outlet Valve (A5) remain open allowing water to flow down through the resin rinsing away the excess caustic and remaining anions. This water takes the same path as in the previous cycle. The rinse is complete when the ph of the water exiting to drain is between 6.8 and 8.1 and the quality starts increasing. Samples can be taken at the test cock just below the Rinse Outlet Valve (A6). This test cock can also be used to tell when the caustic breaks through the bottom of the resin bed. When Rinse is complete, the Anion Column returns to the Service Cycle. Water flows through the Sensor Cell to the Purge Valve (A8). 24

25 REGENERATION CYCLES PURGE CYCLE RINSE to QUALITY The Purge Cycle is the final cycle of regeneration. The Cation Resin has been regenerated with Hydrochloric Acid and the Anion Resin has been regenerated with Sodium Hydroxide. The water coming out of the Cation Column must be between 2.5 and 3.0 ph with 0 Hardness, and the water coming out of the Anion Column should be somewhere between 6.8 and 8.1 ph. The Purge Cycle is used to rinse the Deionizer up to the desired pre-set quality. The Raw Water enters the Cation Column through Valve C1, flows down through the resin and out the bottom of the column as decationized water and into the Anion Column through Valve A1. The decationized water flows down through Anion Resin and out the bottom of the column through the Sensor Cell and out to drain through the Purge Valve (A8). The water running to drain should be low quality deionized water. When the Pre-Set Quality is reached, the Purge Valve (A8) will close and the Failsafe Valve (A2) will open. The Deionizer has returned to the Service Cycle. 25

26 CHEMICAL USAGE AND TIME CYCLES REGENERATION TIME CYCLES All the PRO Series Deionizers are designed to have the same time cycles. The times listed are to be used as initial starting times and may need adjusting based on the water pressure, drain length and height, size and length of draw hose and temperature of chemical. Cation Backwash Time Acid Draw Time Cation Rinse Time Anion Backwash Time Caustic Draw Time Anion Rinse Time Purge 10 min. 30 min. 45 min. 10 min. 60 min. 60 min. 10 min. REGENERATION CHEMICAL REQUIREMENTS The following table is based on regenerating the deionizers with 30% Hydrochloric Acid and diluting it to 6%, and 50% Sodium Hydroxide diluted to 4%. Deionizer Model Cation Resin Quantity Acid Flow Rate (gpm) Gallons of 30% HCl Required Anion Resin Quantity Caustic Flow Rate (gpm) Gallons of 50% Caustic Required Size Eductor Color DB-18 5 ft ft ¾ Red DB ft ft ¾ White DB ft ft ¾ Blue DB ft ft Red DB ft ft White DB ft ft Red Chemicals may be educted as shown or pumped, but flow rates remain the same. A complete water analysis is required when sizing a two-bed deionizer system. The water analysis is needed to predict the maximum quality of the water and the capacity of the system. The flow rate and the amount of water used must is also required. 26

27 CQ CONTROL PROGRAMMING CQ CONTROL FEATURES The CQ Control is an automatic solid-state control, which monitors the quality of the product water and can send an alarm signal or initiate a regeneration when quality drops below a preset limit value. The CQ Control provides outputs to control the regeneration cycles of the Cation and Anion Columns as well as the Failsafe Valve, Purge Valve and the Recirculation Pump. Indicator Lights - The indicator lights lets the operator know what is happening with the deionizer. The green indicator is activated when the system is in the normal service cycle of operation. The red indicator is activated when the deionizer is in a regeneration cycle, or (in the case of a duplex system) stand-by. The quality monitor provides visual indication if the water quality is above or below the set point as well as a digital readout of the quality. See Conductivity Meter Instructions for a more detailed explanation of the operation of the monitor. Manual Regeneration The Deionizer system can be regenerated at any time with the Manual Regeneration Button no matter what the quality of the water. Quality Monitor The water quality monitor is located on the front of the control. It provides a visual check of the water quality being produced by the deionizer. Battery Back-up The CQ Control is shipped with a rechargeable 9-volt battery. If a power failure occurs, the battery can maintain memory for up to 20 hours. Should a power outage occur while the deionizer is in the middle of regeneration, the regeneration will continue from where it was interrupted, when power returns. The battery should be installed on the main logic board and the battery clip attached. Low Voltage The CQ Control operates on 24-Volts AC, through a power reduction transformer. All the outputs from the CQ Control are low voltage. The transformer has a 120- Volt AC Primary and a 24-Volt AC Secondary. MODES of OPERATION The Operating Modes of the Deionizer may be selected during the programming of the CQ Control. Series Regeneration or Parallel Regeneration may be selected by the position of a Toggle Switch. Duplex or Single operation, Regeneration initiated on Quality or from an external contact closure like a Time Clock, Immediate Regeneration or Purge Prior to Regeneration, and Quality Purge or Timed Purge can all be selected with a 4 Position Dip Switch. Both of these switches are located on the Main PC Board. See Picture on next page. 27

28 CQ CONTROL PROGRAMMING Toggle Switch The Toggle provides a way to program the control for Series Regeneration or Parallel Regeneration. If the switch is moved to the left, the Cation Column and the Anion Column will advance through the regeneration cycles simultaneously, otherwise called Parallel Regeneration. If the Toggle Switch is moved to the right, the Cation Column will regenerate first followed by the Anion Column. This is called Series Regeneration. DO NOT leave the toggle switch in the middle position, it will cause the Deionizer to stop in the middle of regeneration. 4-Position Dip Switch - The Dip Switches are numbered from bottom to top, ON is to the left and OFF is to the right. The diagram below indicates the operation of the switches. Toggle Switch for Series / Parallel Operation 4-Position Dip Switch Rechargeable Battery Main PC Board Switch #1 controls the different options for the Purge Cycle. The Purge Cycle is normally set for 10 minutes. If Switch #1 is in the on position, the Purge Valve (A8) will be open during the Purge Cycle until the quality of water rises above the preset limit. The purge valve will open and close during the purge cycle based on quality. If the quality is below the pre-set limit when the cycle ends, the system will go to Alarm. If Switch #1 is in the off position, then the system will purge for the entire time regardless of the quality. Switch #2 controls the Purge Prior to Regeneration function, if the system is set-up to automatically regenerate based on quality. Automatic Regeneration will occur immediately if Switch #2 is in the on position. If Switch #2 is in the off position, the Purge Cycle will occur for up to 5 minutes prior to regeneration. If the water quality returns during the 5 minutes, the deionizer will return to Service. Switch #3 controls the ability to have Automatic Regeneration based on Quality or Semi- Automatic Regeneration. If the water quality drops below the preset limit, a regeneration is initiated this is considered an Automatic Regeneration and Switch #3 must be in the on position. If Switch #3 is in the off position a regeneration can only be started by the Manual Regeneration Button or from an external contact closure. The alarm will be ON Duplex Quality Regen OFF Single activated, but the deionizer will continue to supply 4-Position Dip Switch water if the quality drops below the pre-set limit. Timer Regen 1 Second Delay 5 Minute Delay Quality Purge Timed Purge Switch #4 controls whether the System is to be operated as a Duplex or as a Single System. If Switch #4 is in the on position, the system will operate in conjunction with another CQ Control. One Deionizer will be On-line while the other is in Stand-by. If Switch #4 is off, the control will operate as a Single System. 28

29 CQ CONTROL PROGRAMMING Duplex Wiring - An interconnecting wiring harness is supplied with the CQ Control for Duplex Operation. Two Controls must be connected together in order for the duplex function to work. Connect Terminal #4 in Control A to Terminal #6 in Control B. Connect Terminal #4 in Control B to Terminal #6 in Control A. Connect Terminal #5 in Control A to Terminal #5 in Control B. The Duplex option will not operate correctly with the Purge Prior to Regeneration Option selected, which is Switch #2 of the 4-Position Dip Switch shown on the previous page. Programming the Regeneration Times The 8-position dipswitches on the front of the control are for setting the regeneration times. Each cycle of regeneration has an 8-position dipswitch associated with it. Each switch has a specific number of minutes it activates, and is capable of being programmed from 1 minute up to 255 minutes. Each switch that is turned on adds the minutes associated with it to the other switches. Example: Turn on switch #2 and switch #4. A total of 10 minutes will be set (2 minutes + 8 minutes). If switch #6 and switch #4 are turned on, 40 minutes are programmed (32 minutes + 8 minutes). Refer to the diagram at the right. There are 8 dipswitches on the front of the CQ Control, each dipswitch times a different cycle of regeneration. In order to make things as simple as possible, the eductors and flow rates have been set up so that the time settings for the cycles are the same no matter what size the system. The chart below shows the initial times for each cycle and the switches that need to be turned on to achieve these time settings. 1 Minute 2 Minutes 4 Minutes 8 Minutes 16 Minutes 32 Minutes 64 Minutes 128 Minutes Model All Regeneration Cycle Time Setting Cation Backwash 10 min. X X Dipswitches on Acid Draw 30 min. X X X X Cation Rinse 45 min. X X X X Auxiliary 0 min. Anion Backwash 10 min. X X Caustic Draw 60 min. X X X X Anion Rinse 60 min. X X X X Purge 10 min. X X Note: Time settings in chart are starting points. Actual amount of chemical and percentage along with water pressure will dictate actual times required. 29

30 CQ CONTROL WIRING CONNECTIONS * * * Field Wiring Connections * * * * 30

31 CONDUCTIVITY METER INSTRUCTIONS General Description - The Conductivity Meter utilized in the CQ Control is model BL (120 / 230 volt version) Conductivity Monitor by Hanna Instruments. The Monitor is equipped with a set of Alarm or Dosing contacts. These contacts close when the conductivity drops below the preset value. The preset value should be somewhere between 10 us (100,000 ohms) and 100 us (10,000 ohms), usually 20 us (50,000 ohms). The chart below provides the conversion between ohms and us. Connections and wiring are made via terminal strips on the rear panel. The Probe is easy to clean and requires little maintenance. Other features include automatic temperature compensation of readings, single point calibration, multi-color LED for indicating if the meter is in measurement / dosing / alarm condition, possibility to (Off-Auto-On switch) alarm action mode. Conversion Table Resistivity OHMS Conductivity US /cm Total Dissolved Solids ppm Grains per Gallon 100, , , , , Functional Description Front Panel 1. Liquid Crystal Display 2. Switch for selecting Alarm Mode OFF = alarm disabled Auto = automatic alarm based on set point value ON = alarm always active 3. MEAS - push button to set instrument to measurement mode. 4. SET - push button to display and set the set-point value. 5. SET trimmer pot to adjust set-point value. 6. CAL calibration trimmer pot Color LED indictor Green = meter in measurement mode Orange / Yellow = alarm activated Red Blinking = error condition 31

32 CONDUCTIVITY METER INSTRUCTIONS Functional Description Rear Panel 1. Connections for Conductivity Cell 2. Power Supply Terminal Strip 3. Alarm or Dosing contact closes on bad quality. 4. Not Used 5. Jumper for disabling the overtime control. To disable, simply remove the jumper. See 6 for detailed explanation of overtime control. 6. Trimmer pot for adjusting overtime control. The allows the user to set the maximum period the alarm or dosing contact is closed, from a minimum time of 5 minutes to a maximum of 30 minutes. When the set time is exceeded, the contacts open, the LED indicator on the front panel will blink Red and the LCD will show TIMEOUT. To exit this condition the OFF/Auto/ON switch must be turned Off and then back to Auto. The Jumper should be removed for use with all DI Systems. Set-point Adjustment Turn on the Power and press the SET button; the display will show the default of previously adjusted value, along with the SET indicator. Use a small screwdriver to adjust the SET trimmer pot until the desired set-point value is displayed. The instrument will automatically returns to the normal measurement mode after 1 minute, or if the MEAS button is pushed. Testing the Meter Operation Turn on the control and adjust the set point to 20 us/cm (50,000 ohms). Make sure the #5 jumper has been removed from the rear of the monitor. Turn the Off/Auto/On switch to the Auto position. Immerse the probe in the solution to be monitored, and press the MEAS button (if necessary). The LCD will show the us/cm value of the liquid. The LED indicator will light up Green when the meter is in measurement mode and #3 Dosing contact is open, but will light up Orange/Yellow when #3 Dosing contact is closed. A regeneration will be initiated when the contact is closed. To prevent this temporarily remove one of the wires on the #3 Dosing contact terminals. Calibration The meter should be in the measure mode. Immerse the probe in the calibration solution HI 7033 (this solution is 84.0 us/cm). Shake briefly and wait for reading to stabilize. Adjust the CAL trimmer pot to read 84.0 us on the LCD display. Note: The meter was calibrated at the factory prior to shipment. Probe Maintenance To prolong the life of the probe, it is recommended that it be cleaned regularly. Immerse the tip of the probe in HI 7061 Cleaning Solution at least for 1 hour. If a more thorough cleaning is desired, lightly sand the metal pins with very fine sand paper. After cleaning, rinse the probe with tap water and recalibrate the meter. When not is use, the probe should be cleaned prior to storage. 32

33 TECHNICAL DATA OPERATING CHECK LIST The following information is essential when trouble shooting the deionizer. Take a sample of each regenerant and label. Retain all samples for which labeling is requested below. Follow the instructions and fill-in the required data. 1) Push the regeneration button and record the time. 2) Record rate of flow to drain during cation backwash. gpm 3) Record inlet pressure during cation backwash cycle. psi 4) Record time at start of acid draw. 5) Record rate of flow to drain when acid draw begins. gpm 6) Take a sample of the drain effluent 5 minutes after the start of acid draw. Keep the sample and label it 5C. Record the specific gravity (Sp. G.) 7) Record the specific gravity after 10 minutes, and label 10C. 8) Record the specific gravity after 20 minutes, and label 20C 9) Record the specific gravity after 30 minutes, and label 30C 10) Record the specific gravity after 40 minutes, and label 40C 11) Record time when acid draw stops and rinse begins. 12) Record rate of flow to drain during slow rinse. gpm 13) Record pressure during acid draw and rinse cycles. psi 14) Record time when anion backwash starts. 15) Record flow rate to drain during anion backwash. gpm 16) Record inlet pressure during anion backwash. psi 17) Record time at start of caustic draw. 18) Record rate of flow to drain at start of caustic draw. gpm 19) Take a sample of the drain effluent 5 minutes after the start of caustic draw. Keep the sample and label it 5A. Record the specific gravity (Sp. G.) 20) Record the specific gravity after 10 minutes, and label 10A. 21) Record the specific gravity after 20 minutes, and label 20A. 22) Record the specific gravity after 30 minutes, and label 30A. 23) Record the specific gravity after 40 minutes, and label 40A. 24) Record time when caustic draw stops and rinse begins. 25) Record rate of flow to drain during slow rinse. gpm 26) Record pressure during caustic draw and rinse cycles. psi 27) Record time when Purge (Quality Rinse) starts. 27) Record specific resistivity or conductivity after Purge cycle. 28) Take a sample of the deionized water once quality is reached. Label the sample. 29) Record maximum quality obtained. 30) Record ph of quality deionized water. ph Take a raw water sample and obtain an analysis of the raw water (16 ounce sample required). If necessary, collect two 16 oz samples of cation effluent water and two 16 oz samples of anion effluent water. 33

34 TECHNICAL DATA MEANING of PH The ph is used to measure the acidic or alkaline level of a solution. High ph denotes a more alkaline solution. Low ph denotes an acidic solution. The ph is actually the measure of hydrogen ion concentration in water, and equals the ratio of Bicarbonate Alkalinity to Free Carbon Dioxide. All natural waters fall within a ph of 6.0 to 8.0. A ph of 7.0 is considered to be neutral. ph Acidic Neutral Basic QUALITY of WATER (CONDUCTIVITY or RESISTIVITY) Ions in the water conduct electricity. Electric current flows easier with high concentrations of ions than it does with low concentrations. High quality water is low in ion concentration therefore, has a high resistance to electric current. The measurement of electrical conductivity or resistivity provides an accurate measurement of ionic concentration in the water. Sodium Chloride (mg/l) TDS - mg/l (as CaCO 3 ) Conductivity (µs/cm) Resistivity (ohms) TDS Grains/gal (as CaCO 3 ) ,000, ,000, ,000, ,000, ,000, ,000, ,000, ,000, , , , , , , , , ,000 1, ,

35 TECHNICAL DATA TESTING HARDNESS of DECATIONIZED WATER Decationized water is acidic and must be neutralized before an accurate hardness test can be performed. Draw a pint of decationized water from the cation outlet test cock. Use an eyedropper and add 1 drop of caustic soda at a time until a ph of 7.0 is reached. Take small samples from the pint to perform the ph test. Do not use ph chemicals or litmus paper in the pint sample, they will contaminate the sample and the reading will not be accurate. Once the ph is corrected, a sample can be removed from the pint and the hardness test ran. Follow the instructions supplied with the hardness test kit. DOUBLE REGENERATING the CATION RESIN The primary cause of hardness leakage or premature sodium leakage from the Cation column is lack of regenerant. This may be due to low water pressure, obstructed eductor, blocked draw tubing, or low level of acid in the chemical container. First determine the cause for low acid usage and correct it. Once the problem is corrected, the resin can be restored to peak capacity by overdosing with acid. Reset the acid draw time to double the normal time. Initiate a regeneration and allow system to advance through regeneration normally. This will draw twice the amount of acid and allow twice the normal contact time. The decationized water after regeneration should be between 2.5 and 3.0 ph and 0.0 hardness. If the cation has leaked hardness to the anion column, it must also be acidized. REMOVAL of HARDNESS from the ANION RESIN Leakage of hardness from the Cation column can foul the Anion resin. If poor quality is experienced from the Deionizer, check the hardness of the decationized water. This may be the cause for poor quality. Other causes may be attributed to the lack of Sodium Hydroxide (Caustic Soda) such as low water pressure, obstructed eductor or draw tube, or low chemical. The hardness can be removed from the Anion resin by regenerating it with Acid. The following procedures should be followed to accomplish this. Connect the Acid draw hose to the Anion Eductor and initiate a regeneration of the Anion Column. Drawing acid into the Anion column, which contains sodium hydroxide will cause the release of carbon dioxide. Do not stop the regeneration in the middle of the cycle, the CO 2 must be allowed to escape! Some heat may also be noticed and gurgling sounds from inside the tank, this is normal. Allow the Anion to continue through regeneration. When rinse is complete advance the system to service. Reconnect the acid draw hose to the Cation column and reconnect the caustic draw hose to the Anion column. Initiate a normal regeneration. Monitor the acid and caustic to insure proper amounts of chemical are used for regeneration. 35

36 TECHNICAL DATA The length of time necessary to restore the anion resin s performance depends on the degree of fouling. It may be necessary to allow the unit to sit overnight with the acid in it. Follow the steps below to accomplish this. Connect the drawtubes as previously described. After the acid is drawn, allow the Anion column to rinse for 2 minutes, then turn off the water and remove the fill plug from the top of the tank. Venting the tank in this manner will allow the CO 2 to escape while the system is sitting. Turn off the control and allow the system to sit over night. A minimum of 8 hours is recommended. Connect the drawtubes back to their proper positions. The acid should be connected to the Cation column and the caustic soda should be connected to the Anion column. Replace the fill plug and slowly pressurize the system. Turn on the control panel and advance the anion column into the rinse cycle. Rinse the anion column for 60 minutes. Advance the control to the beginning of the regeneration cycle (Cation Backwash) and allow the system to regenerate normally. After the regeneration, if the quality fails to return, the resin may be beyond salvage or it may be past it s normal service life of 3 to 5 years. In either case, the resin should be replaced. A sample of the resin may be sent to the resin manufacturer for analysis, but there is a fee involved with this, usually $100 or more. REMOVAL of ORGANICS from the ANION RESIN The need to clean the Anion resin bed of organic fouling will most often recognized by long rinses required to achieve quality after regeneration. If it is determined that the resin is organically fouled, a brine solution may be used to remove the organics from the Anion resin. Follow the steps below to brine the Anion column. Mix a solution of 9 parts sodium chloride to 1 part sodium hydroxide. Five gallons of this solution is required for each cubic foot of Anion resin. Example 10 ft3 of anion resin requires 50 gallons of solution. Note: This ratio can be achieved by dissolving 3.75 lbs of salt and 7 oz. of 50% liquid caustic soda in 5 gallons of water. Connect tubing from the salt/caustic solution to the anion eductor. Initiate a regeneration of the Anion column. Allow the Anion to complete the regeneration through the rinse cycle, then advance the control to the service position. Reconnect the normal caustic drawtube to the eductor and then regenerate the entire system. If quality fails to return at the end of the normal regeneration, the resin may be beyond salvage or it may be past its normal service life of 3 to 5 years. In either case, the resin should be replaced. A sample of the resin may be sent to Ecodyne Industrial for analysis, but there is a fee for this service. 36

37 REGENERANT SPECIFICATIONS REGENERANT SPECIFICATIONS for HYDROCHLORIC (MURIATIC) ACID* CHEMICAL 18 BAUME 20 BAUME 22 BAUME SPECIFICATION TECHNICAL TECHNICAL TECHNICAL Strength (% HCl) 27.92% 31.45% 35.21% Sp. Gr Wt. Per Gallon 9.5# 9.66# 9.81# Color Yellow Yellow Yellow Sulfate as (H 2 SO 4 ) 0.003% max % max % max. Sulfite % max % max % max. Calcium % max % max % max. Arsenic 0.1 ppm max. 0.1 ppm max. 0.1 ppm max. Lead % max % max % max. Copper % max % max % max. Iron % max % max % max. Organics % max % max % max. Chlorine 10 ppm 10 ppm 10 ppm Fluorine % max % max % max. CAUTION! ALWAYS ADD ACID TO WATER, NEVER IN THE REVERSE ORDER. WHEN HANDLING ACID, WEAR PROTECTIVE CLOTHING AND FACE MASK. Hydrochloric acid and its fumes are highly corrosive and can cause severe burns on contact with any part of the body. Mucous membranes of the eyes and the upper respiratory tract are especially susceptible to high atmospheric concentrations. NEVER inhale fumes given off by hydrochloric acid and provide adequate ventilation where the acid is being used. Hydrochloric acid will dissolve many metals and cements. It will not react with glass, some rubber, and most plastics. All contact with body or clothing should be avoided. Safety goggles or face shield should be used. If hydrochloric acid does contact the body or clothing, the affected clothing should be removed and large quantities of cold water applied. It is usually not necessary to neutralize the acid, but washing with a mild soap will aid removal. Soda ash, washing soda, salt soda or even baking soda and bicarbonate of soda also can be used on large amounts of spilled acid. If hydrochloric acid splashes on the body, flush with water. Then a solution or paste of baking soda can be used to neutralize the acid. If hydrochloric acid splashes in the eyes, flush with water for minutes. Call a doctor at once. % HCl Specific Lbs. of HCL per Gallon Total Wgt. of Solution Baume Gravity of Solution in Lbs. per Gallon

38 REGENERANT SPECIFICATIONS for SODIUM HYDROXIDE (CAUSTIC) CHEMICAL SPECIFICATION REGENERANT SPECIFICATIONS 50% LIQUID FLAKE OR MERCURY CELL GRADE RAYON GRADE PELLETS RAYON GRADE Strength (% NaOH) % % Sp. Gr Wt. Per Gallon 12.75# 12.75# Sodium Oxide (Na 2 O) % % 76.3% Sodium Carbonate (Na 2 CO 3 ) 0.05% max. 0.20% max. 0.70% max. Sodium Chloride (NaCl) 0.005% max. 0.10% max. 0.25% max. Sodium Sulfate (Na 2 SO) % max. 0.20% max. 0.10% max. Sodium Chlorate (NaCIO 3 ) % max % max. None Silicon (Si) % max % max. 0.02% max. Iron (Fe) % max % max %max. Calcium (Ca) % max % max % max. Magnesium (Mg) % max % max % max. Aluminum (Al) % max % max % max. Manganese (Mn) % max % max % max. Copper (Cu) % max % max % max. Nickel (Ni) % max % max % max. CAUTION! WHEN HANDLING CAUSTIC SODA ALWAYS WEAR PROTECTIVE CLOTHING AND FACE SHIELD OR SAFETY GOGGLES. Caustic soda is a strong alkali, which can cause serious burns on contact with skin or eyes. Caustic dust and mist represent a hazard to the respiratory tract. All contact with body or clothing should be avoided. If caustic soda does contact the body or clothing, the affected clothing should be removed and washed with large quantities of cold water. Caustic destroys wool and leather so these materials should be avoided. If caustic soda splashes on the body, flush with large quantities of water. DO NOT ATTEMPT CHEMICAL NEUTRALIZATION. If caustic soda splashes into the eyes, wash from the eyes with a steady, gentle stream of water for 15 minutes. Do not use soap. Call a doctor at once. % NaOH Specific Gravity Baume Lbs. of NaOH per gallon of Solution Total Weight of Solution in Lbs. per Gallon NOTE: One Gallon of Water = pounds. 38

39 REGENERANT SPECIFICATIONS CONVERSION CHART The chart shown below converts inches to gallons of chemical removed during regeneration from a 50-gallon drum or 15 gallon carboy. CHEMICAL USAGE CONVERSION CHART INCHES 50 GAL. DRUM 15 GAL. CARBOY Gal Gal Gal. 287 Gal Gal Gal Gal..574 Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal Gal. 50 GALLON DRUM: 1 = 1.65 GALLON 15 GALLON CARBOY: 1 =.375 GALLON Note: Measurements are to be made prior to and after regeneration. Measurements are to be taken from the lip of the container opening down to the chemical. Subtract the prior to regeneration measurement from the after measurement to obtain the inches of chemical used. Inches of chemical used can then be converted to gallons using the chart above. 39

40 REGENERANT SPECIFICATIONS QUANTITY OF REGENERANTS PROGRAMMED TO BE USED FOR EACH REGENERATION. (SEE OPERATOR DATA ) ACID: INCHES. CAUSTIC: INCHES. REGENERANT CONTAINER 15 GAL. CARBOY: 50 GAL. DRUM: MEASUREMENT OF INCHES FROM CONTAINER OPENING DOWN TO REGENERANT, NOTED PRIOR TO EACH REGENERATION. INCHES START OF FULL REGENERANT DAY ACID CAUSTIC CONTAINER ENTRY MADE BY The availability and usage of acid and caustic soda during regeneration is one of the most important factors affecting the Deionizer s performance. Exhaustion of either chemical will cause the deionizer to produce a lower quality of treated water than desired. 40

41 MAJOR PARTS and REBUILD KITS PLUMBING PARTS * See Page 43 for tank Internals 41

42 MAJOR PARTS and REBUILD KITS PLUMBING PARTS - Continued ITEM NO. DESCRIPTION PS / PW Deionizer Size Fiberglass Tank Diaphragm Valve - NO Female Solvent Weld Adapter Male Solvent Weld Adapter O-Ring for Adapter Diaphragm Valve NO Valve Retainer & Nut Kit Diaphragm Valve NC/SC/LS Diaphragm Valve NO/SC Isolated Bonnet for Caustic Diaphragm Valve NO/SC Isolated Bonnet for Acid Diaphragm Valve NO/LS Cation - Backwash Flow Control - PVC gpm gpm gpm gpm gpm gpm 13 Anion - Backwash Flow Control - PVC /4 5 gpm gpm gpm gpm gpm gpm 14 Chemical Metering Valve Ball Check Valve Viton for Acid Ball Check Valve EPDM for Caustic Conductivity Sensor Cell Sample Valve Upper Distributor Assembly Lower Distributor Assembly A Hub (only) B Lateral (only) (8-req d) * Draw Tube Assembly * 1/8 NPT x 1/4 Tube Fitting * 1/4 NPT X 1/4 Tube Fitting * 1/4 Tube Tee Fitting * 1/4 Poly Tubing * Items not shown. 42

43 MAJOR PARTS and REBUILD KITS PLUMBING PARTS - (continued) Upper and Lower Distributor Assemblies PLASTIC DIAPHRAGM VALVE REBUILD KITS Normally Open Valve Hole in Shaft Normally Closed Valve Valve Size Description Valve Part No. Diaphragm & Seal Kit NO / SC / LS NC / SC NO / SAO NO / SC NO / SAO / LS NO Bonnet - Caustic Bonnet - Acid / NO / SC / NC / SC / NO-No Spring / NC / SC / LS / NO-25lb Spring / NO / LS / NO / NO / SC / NO / SO

Valve Nest Filter with Time Clock Control Installation and Operation Manual

Valve Nest Filter with Time Clock Control Installation and Operation Manual Valve Nest Filter with Time Clock Control Installation and Operation Manual Effective 5/24/12 Effective 5/24/12 Table of Contents Operating Data. 1 Pre-Installation Data... 2 Filter Parameters Installation

More information

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System INDUSTRIAL SEPARATE BED DEIONIZER High Purity Industrial Packaged System (Twin System with carbon Filtration Tanks shown) 1 P age Deionization is the removal or reduction of positive ions called cations

More information

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer. Construction of Sodium Hypochlorite and Chemical Storage Buildings Page 1 of 7 1. GENERAL 1.1 Scope.1 Boiler feed tank and pumps..2 Blowdown tanks..3 Water Softener System 1.2 Quality Assurance.1 All equipment,

More information

PROJ. NO SECTION DOMESTIC WATER SOFTENERS

PROJ. NO SECTION DOMESTIC WATER SOFTENERS SECTION 22 31 00 DOMESTIC WATER SOFTENERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

REVERSE OSMOSIS WATER TREATMENT

REVERSE OSMOSIS WATER TREATMENT REVERSE OSMOSIS WATER TREATMENT LTF 2, LTF 3 and LTF 4 SERIES RO SYSTEMS 14,400 TO 252,000 GALLONS PER DAY AND LARGER Lakeside Water for Affordable Pure Water Technology 1 P age Packaged Reverse Osmosis

More information

World-Class Equipment & Process Expertise WDI Marketing Package INCLUDED DOCUMENTS. For more information visit

World-Class Equipment & Process Expertise WDI Marketing Package INCLUDED DOCUMENTS. For more information visit Selection Guide WDI Deionization Systems Brochure WDI-5 Elite Water Recycling Datasheet WDI-10 Elite Water Recycling Datasheet WDI-15 Elite Water Recycling Datasheet WDI-5 Swift Water Recycling Datasheet

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS MEDIA FILTER MODELS: Turbidex 21" Media Filters 21 MAGNUM FILTER AUTOMATIC TIMER VALVE TURBIDEX HYPER FILTRATION MEDIA TurbidexTM is more than our name it's the product as well. TurbidexTM granules consist

More information

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION

REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION REACTION TANKS WATER PURIFICATION THROUGH SERVICE DEIONIZATION SERVICE DEIONIZATION (SDI) Service Deionization (SDI) from Evoqua is a safe and economical way for you to obtain consistent, high-purity water

More information

DETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS

DETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS 5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS 1.0 SCOPE 1.1 Provide

More information

SECTION CHEMICAL FEED SYSTEM

SECTION CHEMICAL FEED SYSTEM SECTION 11800 PART 1 GENERAL 1.1 SUMMARY A. This section includes the requirements for the chemical feed system shall be a complete turnkey system inclusive of all necessary fluid handling and ancillary

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11241 - Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S PART 1 - GENERAL... 1 1.01 Scope... 1 1.02 Scope of Work... 1 1.03

More information

The Culligan Hi-Flo 50 Series Industrial Water Filter System

The Culligan Hi-Flo 50 Series Industrial Water Filter System The Culligan Hi-Flo 50 Series Industrial Water Filter System Durable High-Volume Water Filtration for Industrial Applications The Culligan Hi-Flo 50 Filter reduces contaminants* and solids that affect

More information

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business Commercial High-Purity Water Systems and Applications Quality Water Is Our Business Overview High-purity water: definitions High-purity water: methods o Distillation o Deionization o Membrane filtration

More information

World-Class Equipment & Process Expertise HFX Marketing Package INCLUDED DOCUMENTS. For more information visit

World-Class Equipment & Process Expertise HFX Marketing Package INCLUDED DOCUMENTS. For more information visit HFX Marketing Package INCLUDED DOCUMENTS Selection Guide HFX Deionization Systems Brochure HFX35D Water Recycling Datasheet HFX55D Water Recycling Datasheet HFX75D Water Recycling Datasheet HFX115D Water

More information

ION EXCHANGE RESIN CHAMBERS and SYSTEMS

ION EXCHANGE RESIN CHAMBERS and SYSTEMS ION EXCHANGE CHAMBERS and SYSTEMS 367 For PRECIOUS METAL RECOVERY These resin systems can recover gold and other metals from plating operations easily and economically. Select the proper resin for gold

More information

Access manuals, spec sheets and additional educational materials for foodservice water treatment at our website.

Access manuals, spec sheets and additional educational materials for foodservice water treatment at our website. OP-70 Simple Install Guide Rev. 1.1 Access manuals, spec sheets and additional educational materials for foodservice water treatment at our website. www.optipurewater.com OP70_Simple_Install_v1-1.indd

More information

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc.

Evaporative Condenser Passivation. Cameron Klein Strand Associates, Inc. Evaporative Condenser Passivation Cameron Klein Strand Associates, Inc. Evaporative Condenser Wetted Surface Materials of Construction Galvanized Steel Protective zinc coating fused to a steel substrate

More information

1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s].

1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s]. MLRO Specification PART 1 - GENERAL 1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s]. 1.2 QUALITY ASSURANCE A. Certifications,

More information

ChromaPur. Chromic Acid Purification System

ChromaPur. Chromic Acid Purification System Chromic Acid Purification System Eco-Tec s chromic acid purification system ensures dramatic cost savings and improved plating performance. Metal contaminants in a chrome plating bath lead to a decline

More information

Commercial Reverse Osmosis System

Commercial Reverse Osmosis System Commercial Reverse Osmosis System Aqua Clear Water Treatment Specialists manufacturers and engineers standard and custom commercial reverse osmosis systems water to accomodate many different water conditions.

More information

1000 GPD Marlin Reverse Osmosis Instruction & Owner s Manual

1000 GPD Marlin Reverse Osmosis Instruction & Owner s Manual 1000 GPD Marlin Reverse Osmosis Instruction & Owner s Manual AQUAFX INSTALLATION INSTRUCTIONS Congratulations on your new AquaFX water treatment system from Aqua Engineering & Equipment, Inc. We hope your

More information

Water Treatment. Water Conditioning Parts - Aquatrol Pressure Tanks

Water Treatment. Water Conditioning Parts - Aquatrol Pressure Tanks Water Treatment Pressure Tanks Aquatrol Pressure Tanks offer a reliable and cost-effective alternative for all of your light residential to heavy-duty commercial applications. Aquatrol tanks are available

More information

Residential Softener

Residential Softener Residential Softener RL-RA-500 RL-RA-1000 RL-RA-1500 Pictures for reference subject to real products. User Manual Please read this manual in details before using the product and keep it properly in order

More information

Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager

Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager Presented by: Jeff Freitag, The Water Guy Jon Tiegs, General Manager OBJECTIVES Understand The Importance of Practicing Key Performance Indicators (KPI s) in Your Boiler Room Identify Key Components of

More information

FS-8000 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product FS Date of purchase. Address

FS-8000 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM. Type of product FS Date of purchase. Address Type of product FS-8000 Memo Date of purchase Name Address Tel REVERSE OSMOSIS SYSTEM 15 FS-8000 USER'S MANUAL 01 Introduction of FS-8000 02 What is Reverse Osmosis 03 Components& Selections 04 Cartridge

More information

Water supplied by Marafiq does not meet the process requirements.

Water supplied by Marafiq does not meet the process requirements. WATER TREATMENT In Industries Water is used for: a. Drinking b. Cleaning c. Cooling d. Producing Steam e. Process requirement Why we need to treat water? For human consumption a. Water to be purified (Make

More information

REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL. R12-Wall Mount

REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL. R12-Wall Mount REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL R12-Wall Mount IMPORTANT Please read the entire manual before proceeding with the installation and startup: Do not use where the water is microbiologically

More information

A c t i v a t e d C a r b o n F i l t e r Installation Operation Maintenance Manual

A c t i v a t e d C a r b o n F i l t e r Installation Operation Maintenance Manual Installation Operation Maintenance Manual Activated Carbon Filter WS Series Valve CA 1054 CA 1354 CA 1665 CA 2160 CA3072 CA4272 Models CA1248 CA1465 CA1865 CA2469 CA3672 CA4872 Activated Carbon WS Nov

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

WATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters

WATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters WATER FILTRATION EQUIPMENT Commercial Water Filters 7 TO 69 and Larger (Single, Twin, Triple or Quadruple systems) 1 P a g e LWF SERIES filtration equipment can be engineered to solve complex commercial

More information

Copyright 2004 and 2005 by The American Institute of Architects (AIA)

Copyright 2004 and 2005 by The American Institute of Architects (AIA) Page 232500-1 Copyright 2004 and 2005 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical

More information

AEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration

AEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration Commercial Sand Akiki Engineering Series Commercial Sand s are constructed based on efficient and economical method for reducing suspended method down to 40 microns in size on various feed water sources.

More information

SRO70 Installation Manual

SRO70 Installation Manual SRO70 Installation Manual Rev. 2.2 SRO70_Simple_Install_v2-2.indd 2018 Procam Controls, Inc. All Rights Reserved Access manuals, spec sheets and additional educational materials for foodservice water treatment

More information

Advanced water purifier system operation manual and setup guide

Advanced water purifier system operation manual and setup guide Advanced water purifier system operation manual and setup guide What is Reverse Osmosis? Reverse osmosis, also known as hyper filtration, is the finest filtration known. This process will allow the removal

More information

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System.  January 2012 Version MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SC Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description

More information

AQUAVENDOR AUTO. Ultrafiltration Unit SETUP OPERATING INSTRUCTIONS

AQUAVENDOR AUTO. Ultrafiltration Unit SETUP OPERATING INSTRUCTIONS AQUAVENDOR AUTO OPERATING INSTRUCTIONS Ultrafiltration Unit SETUP Locate the Ultrafiltration Unit undercover with sufficient space around the unit for maintenance and for installing plumbing connections.

More information

ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium

ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium ADVANCED SOFTENING MATERIAL for problem water SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium Used by water treatment companies globally since 1998 AMERICA WHAT ECOMIX

More information

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Grab sample capability Low maintenance Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800S i

More information

Softener and Filters Components and Accessories

Softener and Filters Components and Accessories SECTION 12 Softener and Filters Components and Accessories Section 12 Softener and Filter Components and Accessories Catalog 999502 Effective 01/01/13 Table of Contents SOFTENER COMPONENTS AND ACCESSORIES

More information

high efficiency ~ simple package ~ proven reliability ChromaPur Chromic Acid Purification Unit

high efficiency ~ simple package ~ proven reliability ChromaPur Chromic Acid Purification Unit high efficiency ~ simple package ~ proven reliability ChromaPur Chromic Acid Purification Unit Achieve maximum recovery, maximum cost reduction, and maximum quality consistency with Eco-Tec s chromic acid

More information

POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process

POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process Abstract Introduction Beijing Shougang Biomass Energy Technology Co., Ltd, a branch company of SHOUGANG

More information

SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS

SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS Presented at ALBERTA Public Works, Supply & Services Property Management Operations Division Water Treatment Co-ordinators'

More information

BSDI SERIES PACKAGED FILTRATION & DEIONISATION SYSTEMS FOR HIGH PURITY WATER PRODUCTION FOR GENERAL INDUSTRY

BSDI SERIES PACKAGED FILTRATION & DEIONISATION SYSTEMS FOR HIGH PURITY WATER PRODUCTION FOR GENERAL INDUSTRY BSDI SERIES Ideal for batch processing PACKAGED FILTRATION & DEIONISATION SYSTEMS FOR HIGH PURITY WATER PRODUCTION FOR GENERAL INDUSTRY TWO MODELS, TWO FLOW RATES 22.0 litres per minute & 100.0 litres

More information

How to Choose a Water Softener. Brought to you by

How to Choose a Water Softener. Brought to you by How to Choose a Water Softener Brought to you by http://www.yourwaterneeds.com/ Introduction Yourwaterneeds.com team, with more than 20 years experience in the water industry, has created this presentation

More information

By C.F. Chubb Michaud, CWS-VI

By C.F. Chubb Michaud, CWS-VI Boiler Feed Water Reducing Scale and Corrosion, Part 1 of 2 By C.F. Chubb Michaud, CWSVI Summary: A big part of ion exchange s use in commercial/industrial applications involves boiler feed water. This

More information

SECTION 5 E-Treat Water Conditioning Systems

SECTION 5 E-Treat Water Conditioning Systems SECTION 5 E-Treat Water Conditioning Systems WaTEr QualITy PrOduCTS Catalog 10 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts

More information

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Silica Analyzer 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity Grab sample capability Low maintenance Automated Silica Measurement Dependable and Sensitive Silica Analyzer 2800S i

More information

from the water treatment specialists

from the water treatment specialists from the water treatment specialists FLECK 2750 SIMPLEX Valve Simplex Simplex or single column water softeners are best suited to consistent demand applications of moderate total water consumption. Regeneration

More information

DW Module 22 Inorganic Removal Basics Answer Key

DW Module 22 Inorganic Removal Basics Answer Key DW Module 22 Inorganic Removal Basics Answer Key Appendix E: Inorganic Removal Pre-Test 1. Solve the following equation: 385 + (21/7) (5 x 13 x 4) = 17 + 11 (6 x 4) a. 9 b. 7 c. 31 d. 32 Answer: d. 32

More information

EVERPURE COMMERCIAL WATER SOFTENING PRODUCTS FOODSERVICE

EVERPURE COMMERCIAL WATER SOFTENING PRODUCTS FOODSERVICE EVERPURE COMMERCIAL WATER SOFTENING PRODUCTS FOODSERVICE QUALITY WATER IS VITAL TO YOUR OPERATION There are contaminants in nearly all water that over time affect the efficiency of your plumbing and your

More information

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal High Light Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal For sump and rain water Control system available Fiberglass

More information

TAP OUR EXPERTISE COMMERCIAL WATER SOFTENING

TAP OUR EXPERTISE COMMERCIAL WATER SOFTENING TAP OUR EXPERTISE COMMERCIAL WATER SOFTENING HARD WATER CAN BE HARD ON YOUR BUSINESS. When you run a business that uses water, it s important to have the hard facts: hard water costs industry millions

More information

COMMERCIAL WATER SOFTENER LWTF SERIES

COMMERCIAL WATER SOFTENER LWTF SERIES COMMERCIAL WATER SOFTENER LWTF SERIES 30,000 TO 1,100,000 GRAINS CAPACITY WATER SOLUTIONS * COMMERCIAL GRADE PERFORMANCE * CONTINUOUS SOFT WATER * (Single, Twin, Triple or Quadruple systems) 1 P a g e

More information

Bushy Park Industrial Complex Bushy Park, South Carolina

Bushy Park Industrial Complex Bushy Park, South Carolina Utilities Availability - Electrical Power Available at site via SCE&G (distributed by Cooper River - Natural Gas - Available at site via South Carolina Electric & Gas (SCE&G) - Steam Available (6 bar and

More information

Multi-functional Flow Control Valve for Water Treatment Systems Hankscraft Runxin RevV22

Multi-functional Flow Control Valve for Water Treatment Systems Hankscraft Runxin RevV22 Multi-functional Flow Control Valve for Water Treatment Systems Hankscraft Runxin RevV22 Instruction Manual Please read this manual in detail before using the valve and keep it in a safe place for future

More information

Installation, Operation, and Maintenance Manual Aquapurion 600 GPD Line Pressure Reverse Osmosis System

Installation, Operation, and Maintenance Manual Aquapurion 600 GPD Line Pressure Reverse Osmosis System Installation, Operation, and Aquapurion 600 GPD Line Pressure Reverse Osmosis System US Water Systems, Inc. 1209 Country Club Road Indianapolis, IN 46234 1-800-608-8792 support@uswatersystems.com www.uswatersystems.com

More information

High Light. Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation

High Light. Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation High Light Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation Easy installation and removal For sump and rain water Control

More information

OxiPRO Q2.0 Microbial Control Technology

OxiPRO Q2.0 Microbial Control Technology OxiPRO Q2.0 Microbial Control Technology Specification SPEC-613 OxiPRO Q2.0 Microbial Control Technology improves paper machine efficiency by proactively monitoring and controlling microbial-based deposits.

More information

Maintaining Subsurface Drip Irrigation Systems

Maintaining Subsurface Drip Irrigation Systems L-5406 10-01 Maintaining Subsurface Drip Irrigation Systems Juan Enciso, Dana Porter, Jim Bordovsky and Guy Fipps* Subsurface drip irrigation systems deliver low flow rates of water very uniformly. A properly

More information

Operation & Maintenance Manual 2900 Multi-Tank Systems NXT

Operation & Maintenance Manual 2900 Multi-Tank Systems NXT Operation & Maintenance Manual 2900 Multi-Tank Systems - 3200NXT Part# 2900NXT OPERATION MANUAL Operation & Maintenance Manual 2900 Multi-Tank Systems - 3200NXT Nelsen Corporation Part# 2900NXT OPERATION

More information

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water.

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water. EN Demineralised heating water Demineralisation PUROTAP expert Installation Function Operation Service Demineralised heating water makes heating systems safe in accordance with VDI 205 and SWKI BT 102-01

More information

DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50%

DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50% Case History DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50% Site Information Location Indiana, USA Purpose Improve short servicecycle run lengths

More information

WATER TREATMENT SYSTEMS. Reverse Osmosis, Water Softening, and Dechlorination

WATER TREATMENT SYSTEMS. Reverse Osmosis, Water Softening, and Dechlorination WATER TREATMENT SYSTEMS Reverse Osmosis, Water Softening, and Dechlorination Delivers softened and/or reverse osmosis water for a wide variety of applications and processes Stand-alone or complementary

More information

Ion Exchange Resin Analysis Kit for Europe/Middle East/Africa. DOWEX Ion Exchange Resin DIRECTOR Services

Ion Exchange Resin Analysis Kit for Europe/Middle East/Africa. DOWEX Ion Exchange Resin DIRECTOR Services Ion Exchange Resin Analysis Kit for Europe/Middle East/Africa DOWEX Ion Exchange Resin DIRECTOR Services DOWEX Ion Exchange Resin, DIRECTOR SM Services Ion Exchange Resin Analysis Kit This Ion Exchange

More information

Commercial. Softeners Filters Reverse Osmosis

Commercial. Softeners Filters Reverse Osmosis Softeners Filters Reverse Osmosis Commercial Expertise has dedicated Professional Engineers with decades of commercial water treatment experience to compliment our knowledgeable field sales team. Together

More information

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation Background Industrial processes can often result in waste water contaminated with heavy metals (Hg, Pb, Zn,

More information

A. This section includes the requirements for the following chemical feed systems:

A. This section includes the requirements for the following chemical feed systems: SECTION 463654 - CHEMICAL FEED SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This section includes the requirements for the following chemical feed systems: 1. Alum. B. This specification covers the supply,

More information

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM APPLICATION For rapid, safe, standardized low-temperature liquid chemical sterilization of heat-sensitive critical and semi-critical devices. DESCRIPTION

More information

Mission Statement. Profile and History. R.O. UltraTec s Advantages

Mission Statement. Profile and History. R.O. UltraTec s Advantages 2005 PRODUCT CATALOG» Reverse Osmosis Systems» Water Coolers» Filter Cartridges» Filter Housings» Filtration Systems & Water Softeners» Membrane Housings» Membranes» Pumps & Motors» Disinfection Equipment

More information

Cartwright Consulting Co.

Cartwright Consulting Co. Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest

More information

PURE WATER. Installation, Operation and Maintenance Manual. Wall Mounted Commercial Reverse Osmosis Systems. Series PWR2511. Table Of Contents.

PURE WATER. Installation, Operation and Maintenance Manual. Wall Mounted Commercial Reverse Osmosis Systems. Series PWR2511. Table Of Contents. Installation, Operation and Maintenance Manual Wall Mounted Commercial Reverse Osmosis Systems Series PWR2511 IOM-WQ-PWR2511 PURE WATER! WARNING Please read carefully before proceeding with installation.

More information

Pilot Study Report. Z-92 Uranium Treatment Process

Pilot Study Report. Z-92 Uranium Treatment Process Pilot Study Report for Z-92 Uranium Treatment Process conducted at the Mountain Water & Sanitation District, Conifer, Colorado Revised November 11, 4 Page 2 Executive Summary Mountain Water & Sanitation

More information

Trident. Package Water Treatment System

Trident. Package Water Treatment System Trident Package Treatment System The Trident Package Treatment System When Microfloc products first introduced the Trident technology, it represented a significant advancement in water and wastewater treatment

More information

A Green Solutions Company TM ENGINEERED PRODUCTS

A Green Solutions Company TM ENGINEERED PRODUCTS A Green Solutions Company ENGINEERED PRODUCTS A Green Solutions Company Table of Contents The World Leader EZ-FLO Injection systems has proudly offered premium grade injectors, fertilizing products, and

More information

MRI Chiller Installation Guidelines

MRI Chiller Installation Guidelines MRI Chiller Installation Guidelines *These Items are the responsibility of the installing contractor to complete prior to the startup of the MRI Chiller.* **Please refer to DTS chiller manual for further

More information

DESIGN PACKAGE. COMMONS PARK Twin Falls, Idaho

DESIGN PACKAGE. COMMONS PARK Twin Falls, Idaho DESIGN PACKAGE A WATER FEATURE HYDRAULIC DESIGN FOR COMMONS PARK Twin Falls, Idaho P16375-R5 6-16-17 Prepared by FOUNTAIN PEOPLE P.O. Box 807 4600 Highway 123 San Marcos, Texas 78666 SPECIAL DESIGN CONSIDERATIONS

More information

MANUAL DUAL MEDIA FILTER (MILD STEEL)

MANUAL DUAL MEDIA FILTER (MILD STEEL) DUAL MEDIA FILTER This Filter is designed for removal of Turbidity & Iron. Maximum Iron as Fe 1.0 PPM Maximum Turbidity 25 PPM For effective removal Oxidation Chamber & Coagulant addition, ph Correction,

More information

NOTES P: 888-H2O-LOGIC ( ) F:

NOTES P: 888-H2O-LOGIC ( ) F: NOTES P: 888-H2O-LOGIC (426-5644) F: 831-336-9840 info@hydrologicsystems.com www.hydrologicsystems.com BEFORE INSTALLING THE RO SYSTEM WARRANTY Best performance of the system will be achieved when the

More information

MRI Chiller Installation Guidelines

MRI Chiller Installation Guidelines MRI Chiller Installation Guidelines *These Items are the responsibility of the installing contractor to complete prior to the startup of the MRI Chiller.* **Please refer to DTS chiller manual for further

More information

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER 1. Preface OPERATIONS AND MAINTAINENCE MANUAL 1-800-444-8693 Operation and Maintenance Manual For Amcot LRC-H Cooling Tower & LRC-LNS

More information

A-300, A-300E Strong Base Type II Anion Exchange Resin

A-300, A-300E Strong Base Type II Anion Exchange Resin ION EXCHANGE RESINS PRODUCT DESCRIPTION Technical Data A-3, A-3E Strong Base Type II Anion Exchange Resin Purolite A-3 is a Type II, strongly basic gel anion exchange resin with outstanding operating capacity

More information

Lenntech. Ion Exchange Resin Analysis Kit. DOW Ion Exchange Resins DIRECTOR SM Service

Lenntech. Ion Exchange Resin Analysis Kit. DOW Ion Exchange Resins DIRECTOR SM Service Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Ion Exchange Resin Analysis Kit DOW Ion Exchange Resins DIRECTOR SM Service *Includes AMBERLITE, AMBERJET, AMBERSEP,

More information

Cartwright Consulting Co.

Cartwright Consulting Co. Cartwright Consulting Co. WWW.CARTWRIGHT-CONSULTING.COM pscartwright@msn.com United States Office European Office 8324 16 th Avenue South President Kennedylaan 94 Minneapolis, MN 55425-1742 2343 GT Oegstgeest

More information

recycle water reuse it save up to from showers & baths for flushing toilets 30% of water use

recycle water reuse it save up to from showers & baths for flushing toilets 30% of water use Residential recycle - Water reuse Recovery - save recycle water from showers & baths reuse it for flushing toilets save up to 30% of water use www.recoverwater.com How it works Greywater is lightly soiled

More information

Technical Service Bulletin

Technical Service Bulletin 3 TSB207.01 Page 1 Technical Service Bulletin August 2016 TSB207.01 Foulants and cleaning procedures for sanitary, food processing type composite polyamide RO/NF membrane elements This bulletin provides

More information

BG-PURE Reverse Osmosis Drinking Water System Performance Data Sheet

BG-PURE Reverse Osmosis Drinking Water System Performance Data Sheet BG-PURE Reverse Osmosis Drinking Water System Performance Data Sheet Model VTFC5G-PB is tested and certified by WQA against NSF/ANSI 58 for the reduction of TDS BG-PURE SYSTEM CONFIGURATION Table Model

More information

POREX Tubular Membrane Filter (TMF ) Applied in Copper/Nickel Wastewater Treatment System for an Electroplating Industry Park

POREX Tubular Membrane Filter (TMF ) Applied in Copper/Nickel Wastewater Treatment System for an Electroplating Industry Park POREX Tubular Membrane Filter (TMF ) Applied in Copper/Nickel Wastewater Treatment System for an Electroplating Industry Park Abstract Introduction Plating is a widely used process across many industries

More information

For Safe and Delicious Water

For Safe and Delicious Water RESIDUAL CHLORINE ANALYZER 400G NON-REAGENT FREE CHLORINE ANALYZER FC400G 400G RESIDUAL CHLORINE ANALYZER FC400G NON-REAGENT FREE CHLORINE ANALYZER Bulletin 12F01A01-01E www.yokogawa.com/an/ For Safe and

More information

Bucking the Industry Trend. Simple Change to Water System Saves New Jersey Manufacturer $23,000 Annually

Bucking the Industry Trend. Simple Change to Water System Saves New Jersey Manufacturer $23,000 Annually Simple Change to Water System Saves New Jersey Manufacturer by Kevin Preising Sales Engineer . Summary: Over the past two decades, the trend in the water treatment industry has been towards more and more

More information

Technical Data. Typical Chemical & Physical Characteristics

Technical Data. Typical Chemical & Physical Characteristics Technical Data S-940 Macroporous Aminophosphonic Chelating Resin (Especially for decalcification of brine solutions) Section V. PRODUCT DESCRIPTION Purolite S-9 40 is a chelating resin of macroporous structure,

More information

The Iron Curtain Filtration System

The Iron Curtain Filtration System TM The Iron Curtain Filtration System Chemical Free: No Potassium Permanganate No Salt No Chlorine Guards Against: Iron Stains Iron Tasting Water Rotten Egg Odor U.S. Patent No.: B1 5,096,596 Hellenbrand

More information

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001

Series 5000 Analyzers Low Range Phosphate Model and High Range Phosphate Model 60001 Series 5000 Analyzers Low Range Phosphate Model 60005 and High Range Phosphate Model 60001 D epending upon your analysis needs, you can choose from two continuous-reading process analyzers to measure phosphate.

More information

PSP Series Water Purification Systems

PSP Series Water Purification Systems Operations and Maintenance Manual for PSP Series Water Purification Systems PSP-1000 PSP-1600 PSP-2700 Rev. 2 / 08/26/14 Compact Design, Self-Contained Water Processing Unit for Point-Of-Use or Point-Of-Entry

More information

( ) IONPAC ATC-HC ANION TRAP COLUMN

( ) IONPAC ATC-HC ANION TRAP COLUMN PRODUCT MANUAL IONPAC ATC-3 2-mm ANION TRAP COLUMN (4 x 35 mm, P/N 059661) IONPAC ATC-3 4-mm ANION TRAP COLUMN (9 x 24 mm, P/N 059660) IONPAC ATC-HC ANION TRAP COLUMN (9 x 75 mm, P/N 059604) QUICKSTART

More information

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax: Boiler Water Problems and Its Causes Water is the essential medium for steam generation. Conditioning it properly can increase the efficiency of boiler and as well as extend the boiler s life. Treating

More information

Treatment or Process Filtration

Treatment or Process Filtration Reaction Tanks Advanced Membrane Filtration Memtek EFC-Series Microfiltration System A Major Advantage for Reliable Wastewater Treatment or Process Filtration Systems That Give You Greater Flexibility

More information

Selcoperm electrolytic chlorination system

Selcoperm electrolytic chlorination system GRUNDFOS alldos Data Booklet electrolytic chlorination system Reliable and easy generation of hypochlorite solution for disinfection applications General Fundamentals of disinfection Many diseases are

More information

Maintenance of Drip Drip Irrigation Systems. Patrick Byers Regional Horticulture Specialist University of Missouri Extension

Maintenance of Drip Drip Irrigation Systems. Patrick Byers Regional Horticulture Specialist University of Missouri Extension Maintenance of Drip Drip Irrigation Systems Patrick Byers Regional Horticulture Specialist University of Missouri Extension Horticultural Crop Irrigation Outline Components of a trickle irrigation system

More information