Mold resistant, paperless gypsum board shall be used in bath, kitchen, and janitor locations.

Similar documents
1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 09 - FINISHES

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

Education Facility Guide Specification

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

Section GYPSUM DRYWALL

Division 09 FINISHES TABLE OF CONTENTS

SECTION CERAMIC TILE. B. Ceramic tile wall finishes including standard and custom designs.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

University of Missouri St. Louis UMSL Project No. S Thomas Jefferson Library Elevator R&B Project No: Renovation & Repairs

DIVISION 9 FINISHES. This Article on Codes, Regulation and Standards shall apply to all Divisions of the Building Standards

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

F.C.L. INTERIOR FINISHES CHECK LIST 2010 PRODUCT SELECTION - FLOORING GENERAL ITEMS PRODUCT SELECTION GENERAL ITEMS

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT #

SECTION ACOUSTICAL PANEL CEILINGS. A. Section includes acoustical panels and exposed suspension systems for ceilings.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION TILING

SECTION NON-STRUCTURAL METAL FRAMING

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

SECTION CERAMIC TILING

SECTION CONCRETE PAVING SLABS SET IN MORTAR

PART 1 - GENERAL. .2 Refer to the MPI Architectural Manual long form painting specification for guidance and spec notes when using this specification.

Interior finishes include wall finishes, floor finishes, wall base finishes, and ceiling finishes.

SECTION CERAMIC TILE

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

Construction Specification

SECTION ULTRACOMPACT WALL FINISHES - THIN SET

Kolorines Glass Mosaic Tiles Project Specification

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

FIT PROJECT C FEBRUARY % CD OWNER/BID ADD 1-03/08/2018 FIT - MFA FASHION DESIGN TENANT IMPROVEMENT 236 WEST 27TH STREET, 4TH FLOOR

SECTION PAINTS AND COATINGS

TILE TILE

SECTION ACOUSTICAL PANEL CEILINGS

SECTION GYPSUM BOARD

JEFFERSON PARISH SHERIF S OFFICE

FLUID APPLIED WATERPROOFING

Diamondback GlasRoc Tile Backer

SECTION COMMON WORK RESULTS FOR ELECTRICAL

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

ACOUSTICAL PANEL CEILINGS

DIVISION 05 METALS Commissioning of Metals STRUCTURAL METAL FRAMING Structural Steel Framing

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

SECTION HYDRAULIC CEMENT UNDERLAYMENT

avante Freedom of expression

Burlington County Department of Resource Conservation Contract CPU SECTION GYPSUM BOARD PART 1 - GENERAL 1.

CTIOA REPORT

Fiber Reinforced Tile and Stone Mortar

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

INDUSTRIAL PAINTING SCHEDULE GUIDE

CASWELL COUNTY Renovation & Addition NOVEMBER 2017 GUNN MEMORIAL PUBLIC LIBRARY

SECTION ALUMINUM WINDOWS

Resilient Flooring Installation Solutions

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

CSI GUIDE Countertops

Cementitious Wood Fiber Products For Ceilings, Walls, and Roof Decks

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

SECTION GYPSUM BOARD ASSEMBLIES

LATICRETE Family of Adhesives PRODUCT CATEGORY USE MIX WITH SUBSTRATE APPLICATION

SPECIFICATION GUIDE. thin glazed brick

Selecting and Specifying Ceramic Tile with ANSI and ISO Standards

SECTION RESILIENT SHEET FLOORING

Installation of Large Format Tile & Stone

INTERIOR FINISHES CHAPTER 8

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION LINEAR METAL CEILINGS

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION EPOXY FLOORING SYSTEMS

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

INSTALLATION SYSTEMS FOR FLOORING PROFESSIONALS. High-quality products Progressive ideas Great service

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

INTERIOR FINISHES CHAPTER 8

DIVISION 9 - SECTION QTscu Recycled Rubber Sound Underlayment US Patent No. RE 41,945

for the master tradesman Setcrete Product Guide

SECTION RESILIENT STAIR TREADS CSI 3-PART SHORT-FORM GUIDE SPECIFICATION USE FOR OUTLINE OR DD SPECIFICATION ISSUES. EDIT TO SUIT PROJECT

Floor Insulation Underlayment Section Sound Control Matting

POOLS AND WATER FEATURES Concrete Tank Cementitious Waterproofing Bonded Mortar Bed Concrete, Ceramic Tile

A. Product Data: For each type of deck, accessory, and product indicated.

Exterior Walls Wood or Metal Studs Cement Backer Board Ceramic Tile

STEAM SHOWER / ROOM; WOOD OR METAL STUDS Wood or Metal Studs Cement Backer Board Walls, Mortar Bed Floor Ceramic Tile

SECTION PAINTS AND COATINGS. 1.3 REFERENCES A. ASTM D 16 - Standard Terminology for Paint, Related Coatings, Materials, and Applications; 2000.

***************************************************************************************************************

SOUTHEASTERN PENNSYLVANIA TRANSPORTATION AUTHORITY 1234 MARKET STREET, PHILADELPHIA, PA SPECIFICATION FOR CERAMIC TILE FOR 15 th STREET STATION

A. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section:

ENKASONIC FLOOR UNDERLAYMENT 9110

SECTION ALTERNATES

SECTION GYPSUM BOARD

SECTION MANUFACTURED MASONRY VENEER

EDGEWATER, FLORIDA JUNE 14, 2010

RESILIENT FLOORING

FLOORING INSTALLATION SYSTEMS. Product Catalog

Transcription:

09 00 00 - FINISHES 09 00 00 General Information CCU is continuing its investigation into preferred floor surface materials. In general, selection of floor materials should consider the environmental impact of maintenance chemicals and long term maintenance costs. Careful review with Project Manager and maintenance staff for each project is incouraged. General floor finishes for use by area: Lobbies: Ceramic Tile, Terrrazo, Corridors: Resilient Sheet, Carpet Tiles, or Resilient Tile. Offices: Carpet Tiles, Resilient Sheet, or Resilient Tile. Classrooms: Carpet Tiles, Resilient Sheet, or Resilient Tile. Dormitory Rooms: Resilient Sheet, or Resilient Tile. Laboratories: Resilient Sheet. Restrooms: Ceramic Tile. Janitor Closets: Ceramic Tile with 1/4" solid surface (Corian) surround at mop sink walls. Specify that the contractor be responsible for initial cleaning and maintenance of the floor until final completion. Architects and Engineers are responsible for proper selection of materials in each building system for specific projects; these standards do not relieve the designer from that responsibility. 09 29 16 Gypsum Board G-P Gypsum Corp., Lafarge North America Inc., National Gypsum Company., United States Gypsum Co. Mold resistant, paperless gypsum board shall be used in bath, kitchen, and janitor locations. As standard practice, office and classroom partitions should utilize a design incorporating sound attenuation batts. Credit MR 4.1: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Credit MR 5.1 and Credit MR 5.2: For products and materials required to comply with requirements for regional materials indicating location and distance from Project of material manufacturer and point of extraction, harvest, or recovery for each raw material. Finishes January 12, 2011 09 00 00-1

Include statement indicating cost for each regional material and the fraction by weight that is considered regional. Credit EQ 4.1: For adhesives used to laminate gypsum board panels to substrates, including printed statement of VOC content. 09 30 00 Ceramic Tile Entry Lobbies, Stairs, Toilet Rooms, Shower Rooms Ceramic tile to be selected on a project specific basis. Interior Installations, Recessed Concrete Subfloor: Tile Installation F112: Cement mortar bed (thickset) bonded to concrete. Interior Floor Installations, Flat Concrete Subfloor: Tile Installation F113: Thin-set mortar. Interior Wall Installations, Masonry or Concrete Tile Installation W202: Thin Set Mortar Tile Type: Unglazed porcelain tile. Shower Receptor and Wall Installations, Concrete or Masonry: Tile Installation B414: Cement mortar bed (thickset). Bond Coat Mortar for Wet-Set Method: Latex- portland cement mortar. Grout: Polymer-modified sanded or unsanded grout. Epoxy Grout in wet areas. Finishes January 12, 2011 09 00 00-2

Product Certificates for Credit MR 5.1 and Credit MR 5.2: For products and materials required to comply with requirements for regional materials indicating location and distance from Project of material manufacturer and point of extraction, harvest, or recovery for each raw material. Include statement indicating cost for each regional material and the fraction by weight that is considered regional. Credit EQ 4.1: Manufacturers' product data for adhesives and sealants, including printed statement of VOC content. 09 51 13 Acoustical Panel Ceilings Standards: IBC 1621.1, CISCA Seismic Zones 3 & 4. CCU prohibits the use of thermal batts on the top of acoustical panel ceilings. Mineral Base. Armstrong World Industries; Ultima Item No. 1911, 2' by 2' square.. Ceramic/Mineral Base. Armstrong World Industries; Ceramaguard with HumiGuard Max, Item No. 607, 2' by 2' square. Metal Suspension System. Armstrong World Industries, Inc.; Prelude XL 15/16 Exposed Tee System." Perimeter Trim for Seismic Restraint: 2 inch wide 7823 Shadow Molding by Armstrong. Product Data for Credit MR 4.1: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Product Data for Credits MR 5.1 and 5.2: For regional products, documentation indicating percentages by cost of materials extracted, processed and manufactured within 500 miles of project site. Product Data for Credit EQ 4.1: content. 09 65 16 Resilient Sheet Flooring For sealants, including printed statement of VOC Entry Lobbies, Stairs, High traffic areas such as corridors and some classroom locations. Consider use of rubber floors and linoleum (Marmoleum) where sheet goods are applicable. 09 68 13 Tile Carpeting Finishes January 12, 2011 09 00 00-3

Offices, Select Classroom Locations Consider use of carpet tiles where carpeting is applicable. 09 91 00 Painting CCU prefers the use of Sherwin Williams paint colors for simplicity when referencing colors for maintenance purposes. Specify Sherwin-Williams products where possible. Exterior Painting Systems Galvanized-Metal Substrates: 1. Latex System: MPI EXT 5.3A. a. Prime Coat: Cementitious galvanized-metal primer. b. Intermediate Coat: Exterior latex matching c. Topcoat: Exterior latex (gloss). Steel Substrates, including Exterior Custom Canopy, Pipe Columns and Metal Fabrications: 2. Polyurethane, Pigmented, Over High-Build Epoxy Coating System: MPI EXT 5.1G. a. Prime Coat: Epoxy zinc primer, MPI#20 (Omit for shop primed items). b. Intermediate Coat: High-build epoxy marine coating, low gloss, MPI #108. c. First Topcoat: Polyurethane, two-component, pigmented, gloss, MPI #72. d. Second Topcoat: Polyurethane, two-component, pigmented, gloss, MPI #72. Interior Painting Systems Concrete Unit Masonry: Provide the finish systems over interior concrete masonry: 3. Institutional Low-Odor/VOC Latex System: MPI INT 4.2E. a. Prime Coat: Interior/exterior latex block filler. 4. Water-Based Epoxy Coating System: MPI INT 4.2J. a. Prime Coat: Interior/exterior latex block filler, MPI #4. b. Intermediate Coat: Water-based epoxy (interior and exterior), MPI #115. c. Topcoat: Water-based epoxy (interior and exterior), MPI #115. Gypsum Board Substrates: Finishes January 12, 2011 09 00 00-4

5. Institutional Low-Odor/VOC Latex System: MPI INT 9.2M. a. Prime Coat: Interior latex primer/sealer. 6. Water-Based Epoxy Coating System: MPI INT 9.2F. Steel Substrates: a. Prime Coat: Interior latex primer/sealer, MPI #50. b. Intermediate Coat: Water-based epoxy, MPI #115. c. Topcoat: Water-based epoxy, MPI #115. 7. Institutional Low-Odor/VOC Latex System: MPI INT 5.1S. a. Prime Coat: Rust-inhibitive primer (water based). (Omit for shop primed items.) 8. Water-Based Dry-Fall System for Exposed Steel Deck, Joists and Framing (over shop applied Q.D. shop primer): MPI INT 5.1CC. a. Prime Coat: Shop applied Q.D. primer. b. Topcoat: Latex dry fog/fall (semigloss). Galvanized-Metal Substrates: 9. Institutional Low-Odor/VOC Latex System: MPI INT 5.3N. a. Prime Coat: Waterborne galvanized-metal primer. Credit EQ 4.2: For paints, including printed statement of VOC content. Finishes January 12, 2011 09 00 00-5