SL60 Introduction. NanaWall SL60 The Standard Thermally Broken Aluminum Framed Folding System

Similar documents
SL35 Introduction. NanaWall SL35 The Standard Aluminum Framed Folding System

SL70 Introduction. NanaWall SL70 The Monumental Thermally Broken Aluminum Framed Folding System

The Aluminum Framed Monumental Folding/Paired Panel System

SL70 The Monumental Thermally Broken Aluminum Framed Folding System

NanaWall Matching Windows and Doors Table of Contents

NanaWall HSW60 - Thermally Broken Aluminum Framed Single Track Sliding System

SECTION FOLDING GLASS PARTITIONS

SECTION FOLDING GLASS STOREFRONTS SECTION FOLDING GLASS DOORS

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

Theut Company,LLC Theut Company, LLC

SECTION SLIDING GLASS STOREFRONTS SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

SECTION WOOD FRAMED FOLDING GLASS PARTITIONS

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

SECTION ALL GLASS CENTER PIVOT PARTITIONS

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

SECTION ALUMINUM STORM WINDOWS

TMS 114 XT TECHNICAL MANUAL

Series 510-I Thermal Heavy Commercial Projected Window

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

SECTION SECTIONAL OVERHEAD DOORS

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

Custom fabrication in two weeks or less, guaranteed.

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

SECTION ALUMINUM WINDOWS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

TMS 152 / 152T / 152XT TECHNICAL MANUAL

Sliding Patio Doors Brickmould Vinyl

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Quality. Care. Commitment. series 8000 doors supreme quality

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS

Series Heavy Commercial Projected Window

SECTION ACCORDION FOLDING PARTITIONS

2. Manufacturer. 3. Product Description. Sliding aluminum framed glass doors Panda Windows and Doors, LLC. Basic Use

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

FRENCH DOOR VINYL SERIES 455 / 555

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW

Series - 1

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW

WESTECK WINDOWS and DOORS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

General Specifications COMPLETE PRODUCT LINE

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

Maximize your security, protection and energy efficiency

SECTION A1 SERIES 200, 300 AND 500 ENTRANCE DOORS

GLASS WALL SPECIFICATIONS

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

SWING DOOR SPECIFICATION

Corium Brick Rainscreen System Specifications

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

ALL-ALUMINUM DOOR & WINDOW FRAMING

GLASSWALL SPECIFICATIONS

Series x Thermal Triple Set Storefront Framing

SECTION (08410) - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

THERMALLY BROKEN STEEL WINDOWS STEEL WINDOW INSTITUTE A STANDARD OF EXCELLENCE

GLASS WALL SPECIFICATIONS

IS.14 All Aluminum IMPACT Lift & Slide Door System

Vinyl Windows and Doors

Series 3000 Pocket Doors

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

SLIDING PATIO DOOR DESIGNS REHAU SYSTEM Construction Automotive Industry

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

HD-Slide Series 2001 Heavy Duty Aluminum Sliding Door System with Electric Belt Drive Operator

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

FoldingAccess Series Aluminum Folding Door System

HomeMaker3 Windows and Doors

New Construction Windows and Doors

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

Architectural Specification Manual

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

ARCHITECTURAL SPECIFICATIONS. Section Master Format Section

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

SECTION DECORATIVE METAL AND GLASS RAILING

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations

American Architectural Manufacturers Association VOLUME 1 - WINDOWS AND DOORS

SPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

Awning Windows Montecito New Construction Window

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

Casement Windows Montecito New Construction Window

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

Transcription:

NanaWall SL60 The Standard Thermally Broken Aluminum Framed Folding System The SL60 is a thermally broken, aluminum folding panel system designed to provide an opening glass wall for openings up to 39 feet wide. It is appropriate for mostly residential applications where high levels of resistance to air and water infi ltration are desired. For benefi ts of all NanaWall systems, see the General Introduction section. For features common to aluminum folding systems, see the Aluminum Folding Systems Introduction. High Weather Resistance The system is engineered to provide high weather resistance and structural performance. The inward-opening unit with Raised Sill (higher weather performance sill) tested to AAMA HGD- LC45 915x2600 with no water entry, even at 15 psf. See the Performance and Testing Results section for more details. NFRC-Approved Thermal Performance / Energy Star The SL60 has been rated, certifi ed and labeled in accordance with NFRC 100 and 200; see the Performance and Testing Results section for more details. Florida Approval The SL60 system is Florida statewide approved with Product Approval number FL 8349. This information with limitations can be viewed at http://www.fl oridabuilding.org. Acoustical Performance The SL60 system has been tested by an independent acoustic lab for acoustical performance. The SL60 with Raised Sill SL60 Introduction (higher weather performance sill) and STC 38 laminated glass achieved STC and Rw values of 38. Life Cycle Performance The SL60 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. Superior Thermal Break The system is thermally broken with a wide polyamide plastic reinforced with glass fi bers. This thermal barrier provides increased strength, superior humidity control, improved acoustics, and energy savings. Top-Hung or Floor-Mounted On the top-hung SL60/o, the main weight is carried by the head track. On the fl oor-mounted SL60/u, the lower running carriages ride on top of the sill track. Variable interlocking profi les minimize expansion problems. Especially for High Rises: Easy Cleaning Feature For balcony applications, there is an easy hinge removal option, facilitating glass cleaning from the inside. Dual Color Option The option of different fi nishes on the inside and outside is available; see the Color Selection section in General Introduction. Hardware Options For the main entry panel, several locking options are available. The profi le locking cylinder (if any) on the main entry panel is Schlage-compatible. SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 1

SL60 Technical Description Technical Description The SL60 is a thermally broken aluminum folding panel system designed to provide an opening glass wall or storefront for openings up to 39' wide; see Maximum Size Chart. It is available in various confi gurations utilizing one to twelve panels; see elevation drawings. The option exists for swing entry/exit panel(s); note the further panel size constraints with a swing panel not hinged to a side jamb. Units can be either inward-opening or outward-opening; see details in section drawings. The SL60/o system is the top-hung system and the SL60/u system is the fl oor-mounted system. Frame and Panels The nominal extruded aluminum frame and panel thickness is 2 3/8" (60 mm), thermally broken with a wide polyamide plastic; see section drawings. In addition to the choices from the NanaWall Powder Coating Finish Chart, the full range of RAL high gloss and matte powder coatings are available. Anodized fi nished are also available; see Aluminum Finish Options in the General Introduction. It is possible to have different fi nishes on the interior and exterior surfaces. Panel stiles and rails are connected by special cast-alloy, thermally broken corner fi ttings that incorporate hinge components, with fi nish that will be closest powder coat match to fi nish of frame and panels. Panels are pre-assembled, and all pins and screws needed to assemble frames are provided. Besides the more weather resistant Raised Sill in profi le matching fi nish, various thermally broken aluminum fl ush sills (shown in section drawings) are available as an option in a clear or dark bronze anodized fi nish. Glazing Units can be supplied either glazed with 15/16" (24 mm) clear insulating tempered or insulating Low-E tempered glass or other high performing safety glass such as Heat Mirror, Triple Glazed, acoustic, special tint, etc., or other glass on request. See Glazing in the General Introduction for other glass thickness possible. Weatherstripping All weather-stripping (consisting of EPDM or brush seals) is provided for sealing between panels and between panel and frame; see section drawings. Sliding/Folding Hardware For sliding and folding of each pair of panels for the SL60/o system, attached to the upper corner of the panel (as indicated on the section drawings) is an upper load-bearing running carriage. Attached as a guide to the lower corner of that panel is a lowerrunning carriage. The double pair, twin-tandem, upper-running carriage is constructed to insure even distribution of pressure on all four rollers. For the SL60/u system, a fl oor supported, two-wheeled, lower-running carriage is attached to the lower corner of a panel, and an upper-running carriage is attached to the upper corner of that panel as a guide. Rollers have sealed bearings and are coated with toughened Polyamide to ensure quiet running and optimal resistance to extreme temperature. Hinges at the corners of each panel are provided to connect panels together and to connect panels to frames. Locking Hardware and Handle Options For each pair of folding panels (except for the pair to be opened fi rst in a unit with no swing panels), provided is two point locking hardware consisting of top and bottom Polyamide capped locking bolts operated by a 180 turn of a fl at handle on the inside only. For a unit with a swing panel, on the primary swing panel, provided is multi-point locking consisting of lever handles on both sides, a Schlage compatible lockset, lockable latch, deadbolt and rods at the top and the bottom. After turn of key or thumbturn, depression of handles withdraws latch, lifting of handles engages rods and turn of key or thumbturn engages deadbolt and locks. For a unit with a secondary swing panel, available are matching dummy lever handles on both sides and concealed fl ush bolts that operate the rods at the top and the bottom. For a unit with no swing panel, on the folding pair to be opened fi rst, provided is two point locking hardware consisting of top and bottom Polyamide capped locking rods operated by a 180 º turn on the inside of a L-shaped handle for an inward opening unit and a fl at handle for an outward opening unit. In both cases, there will be a fl at handle on the outside. Lockable with a lockset. Turn of key or thumb turn operates lock. Please note that for an outward opening unit, locking from the inside will need to be with a key that may not meet egress requirements. For a unit where locking/handles on the inside only is desired, like in window applications, on all swing panels or pair of folding panels to be opened fi rst, provided is two point locking with a fl at handle on the inside only. Handle finish schemes: Standard Stainless steel lever, fl at and L shaped handles in brushed satin or black titanium fi nish. Optional Brass lever handles in oil rubbed, satin nickel or white fi nish, fl at handles closest powdercoat match to panel aluminum fi nish and nylon L shaped handles in dark brown, gray or white fi nish. 2 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

SL60 Performance Testing Results RAISED SILL TYPE OF TEST INWARD OPENING UNITS OUTWARD OPENING UNITS *Air Infiltration: ASTM E-283, ft 3 /min./ft. In accordance with NFRC 400 @1.57 psf (75 Pa): 0.02 + A3 (.25 (m 3 /h)/m) @1.57psf (75 Pa): 0.02 +A3 (.1(m 3 /h)/m) @6.24 psf (300 Pa): 0.06 @6.24psf (300 Pa): 0.04 *Water Penetration: ASTM E-547 and E-331 *Structural Load Deflection ASTM E-330: pass See design windload charts for other sized panels Note that the structural test pressures were 50% higher than the design pressures. No uncontrolled water entry @15 psf (715 Pa) + B7 Design Pressure Positive @45 psf (2160 Pa) Design Pressure Negative @45 psf (2160 Pa) +Windload Resistance: C4 (1920 Pa) Blow-out: C3 (3240 Pa) Standard Unit: No uncontrolled water entry @2.9 psf (140 Pa) Unit with weepholes and gasket (not standard unit): No uncontrolled water entry up to 9.82 psf (470 Pa) +B4 Design Pressure Positive @45 psf (2160 Pa) Design Pressure Negative @45 psf (2160 Pa) +Windload Resistance: C4 (1680 Pa) Blow-out: C3 (3240 Pa) Life Cycle Performance The SL60 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. *Forced Entry Thermal Performance: In accordance with AAMA-1304 requirements Rated, certified and labeled in accordance with NFRC 100 + 200 FLOOR MOUNTED TOP HUNG FLOOR MOUNTED TOP HUNG TYPE OF GLASS (1 LITE) Double IG Clear (air filled) Double IG Low E (argon filled) Double IG Low E (air filled) Double IG Low E on #2/#4 surfaces (argon filled) Double IG Low E on #2/#4 surfaces (air filled) CENTER OF GLASS U-FACTOR GLASS THICKNESS 2010 UNIT U FACTOR SHGC ENERGY STAR 2010 UNIT U FACTOR SHGC ENERGY STAR 2010 UNIT U FACTOR SHGC ENERGY STAR 2010 UNIT U FACTOR SHGC ENERGY STAR.48 15/16".51.49 -.52.49 -.52.50 -.52.49 -.26 15/16".37.28 -.37.28 -.37.28 -.38.28 -.30 15/16".39.28 -.40.28 -.40.28 -.41.28 -.21 15/16".33.26 -.34.25 -.34.26 -.34.25 -.24 15/16".35.26 -.36.25 -.35.26 -.36.25 - Double IG Heat Mirror TC88 (argon filled) Double IG Heat Mirror TC88 with Low E (argon filled) Double IG Heat Mirror TC88 x2 (krypton filled) Triple IG Low E x2 (argon filled) Triple IG Low E x2 (air filled).14 1 3/8".31.33 -.31.33 -.31.33 -.32.33 -.13 1 3/8".30.23.08 1 3/8".26.27.13 1 3/8".27.23.16 1 3/8".30.23.31.22.31.23.31.21.27.27.27.27.28.27.28.23.28.23.29.23.30.23.30.23.31.23 ** Acoustical Performance With STC 38 laminated glass achieved STC and Rw values of 38 NOTES *Excerpts of results of 9'5" W x 8'2 1/2" H three panel units tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in August 2006. ** Excerpts of results of 13'7" W x 8'8" H five panel unit with raised sill tested by Nusing Mobile Trennwandtechnile, Munster, Germany, an independent testing laboratory in November 2005. SHGC = Solar Heat Gain Coefficient 2010 Energy Star Qualification Criteria: U-Factor <.32, SHGC <.30 for doors in all climate zones. Call NanaWall for U-Factor & SHGC for other glass types +Results per Canadian CSA A440-00 SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 3

SL60 Testing Results - Performance of the SL60 NanaWall LOW PROFILE SADDLE SILL AND STANDARD FLUSH SILL TYPE OF TEST INWARD OPENING UNITS OUTWARD OPENING UNITS *Air Infiltration: ASTM E-283, ft 3 /min./ft. In accordance with NFRC 400 *Water Penetration: ASTM E-547/E331 Not applicable for standard flush sill @1.57 psf (75 Pa): 0.16 +A2 (.8(m 3 /h)/m) @1.57 psf (75 Pa): 0.16 +A2 (.8(m 3 /h)/m) @6.24 psf (300 Pa): 0.33 @6.24 psf (300 Pa): 0.33 No uncontrolled water entry @ 5.43 psf (260 Pa) +B2 Subject to the following adaptations of the sill in the field by others: 1. Remove the gaskets covering the inner channel. 2. Drill weep holes through the bottom of this channel (about one 1" x 1/4" weep hole per panel.) 3. Drill weep holes through the lower front face of the sill to drain water collected to a lower point (about one 1" x 1/4" weep slot per panel or equivalent circular weepholes.) Please note that due to varying site requirements and conditions, these sills will not be prepared for drainage by Nana Wall Systems, Inc. If this drainage system is desired, we recommend that a qualified professional construct this system on the project site strictly in accordance with NanaWall instructions with good waterproofing techniques. If drain connections are not made or are not possible, unit may leak with wind driven rain. *Structural Load Deflection ASTM E-330: pass See design windload charts for other sized panels Note that the structural test pressures were 50% higher than the design pressures Design Pressure Positive @45 psf (2160 Pa) Design Pressure Negative @45 psf (2160 Pa) +Windload Resistance: C4 (1680 Pa) Blow-Out: C3 (3240 Pa) Design Pressure Positive @45 psf (2160 Pa) Design Pressure Negative @45 psf (2160 Pa) +Windload Resistance: C4 (1680 Pa) Blow-Out: C3 (3240 Pa) Life Cycle Performance The SL60 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. **Forced Entry Resistance In accordance with AAMA -1304 requirements Thermal Performance Rated, certified and labeled in accordance with NFRC 100 + 200 LOW PROFILE SADDLE SILL LOW PROFILE SADDLE SILL FLOOR MOUNTED TOP HUNG FLOOR MOUNTED TOP HUNG TYPE OF GLASS (1 LITE) CENTER OF GLASS U-FACTOR GLASS THICKNESS UNIT U FACTOR SHGC 2010 ENERGY STAR UNIT U FACTOR SHGC 2010 ENERGY STAR UNIT U FACTOR SHGC 2010 ENERGY STAR UNIT U FACTOR SHGC 2010 ENERGY STAR Double IG Clear (air filled) Double IG Low E (argon filled) Double IG Low E (air filled) Double IG Low E on #2/#4 surfaces (argon filled) Double IG Low E on #2/#4 surfaces (air filled) Double IG Heat Mirror TC88 (argon filled) Double IG Heat Mirror TC88 (argon filled) with Low E Double IG Heat Mirror TC88 x2 (krypton filled) Triple IG Low E x2 (argon filled) Triple IG Low E x 2 (air filled).48 15/16".52.50 -.55.49 -.53.50 -.53.50 -.26 15/16".37.28 -.38.28 -.38.28 -.38.28 -.30 15/16".40.28 -.41.28 -.40.28 -.41.28 -.21 15/16".33.26 -.34.26 -.34.26 -.35.26 -.24 15/16".35.26 -.36.26 -.36.26 -.37.26 -.14 1 3/8".31.34 -.32.33 -.32.34 -.32.33 -.13 1 3/8".30.23.08 1 3/8".27.28.13 1 3/8".28.23.16 1 3/8".30.23.31.23.31.23.32.23.28.27.27.28.28.27.29.23.28.23.29.23.31.23.31.23.32.23 NOTES *Excerpts of results of a 9'5" W x 8'2" H three panel unit tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in August 2006. SHGC = Solar Heat Gain Coefficient 2010 Energy Star Qualification Criteria: U-Factor <.32, SHGC <.30 for all doors in all climate zones. Call NanaWall for U-Factor & SHGC for other glass types +Results per Canadian CSA A440-00 4 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

Testing Results - Performance of the SL60 NanaWall SL60 STANDARD FLUSH SILL TYPE OF TEST INWARD OPENING UNITS OUTWARD OPENING UNITS Thermal Performance Rated, certified and labeled in accordance with NFRC 100 + 200 FLUSH SILL FLUSH SILL TYPE OF GLASS (1 LITE) CENTER OF GLASS U FACTOR GLASS THICKNESS FLOOR MOUNTED TOP HUNG FLOOR MOUNTED TOP HUNG 2010 UNIT U FACTOR SHGC ENERGY STAR 2010 UNIT U FACTOR SHGC ENERGY STAR 2010 UNIT U FACTOR SHGC ENERGY STAR 2010 UNIT U FACTOR SHGC ENERGY STAR Double IG Clear (air filled).48 15/16".52.51 -.52.50 -.52.51 -.53.50 - Double IG Low E (argon filled).26 15/16".37.28 -.37.28 -.37.28 -.38.28 - Double IG Low E (air filled).30 15/16".39.28 -.40.28 -.40.28 -.41.28 - Double IG Low E on #2/#4 surfaces (argon filled) Double IG Low E on #2/#4 surfaces (air filled) Double IG Heat Mirror TC88 (argon filled) Double IG Heat Mirror TC88 (argon filled) with Low E Double IG Heat Mirror TC88 x2 (krypton filled) Triple IG Low E x 2 (argon filled).21 15/16".33.26 -.34.26 -.33.26 -.34.26 -.24 15/16".35.26 -.36.26 -.35.26 -.36.26 -.14 1 3/8".30.34 -.31.33 -.31.34 -.32.34 -.13 1 3/8".30.23.31.23.30.23.31.23.08 1 3/8".26.28.27.27.27.27.28.27.13 1 3/8".27.23.28.23.28.23.29.23 Triple IG Low E x 2 (air filled).16 1 3/8".29.23.30.23.30.24.31.23 SHGC = Solar Heat Gain Coefficient 2010 Energy Star Qualification Criteria: U-Factor <.32, SHGC <.30 for all doors in all climate zones. Call NanaWall for U-Factor & SHGC for other glass types SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 5

SL60 Maximum Size Chart (with different number of panels) RESIDENTIAL 9'6" (2900) 9 2 (2800) 8 10 (2700) NOTE: English dimensions are approximate. Dimensions in parenthesis are in millimeters A B Up to twelve panels are possible in a unit. Any custom panel size is possible up to the maximum size shown. The total overall unit width is the number of panels multiplied by the individual panel width. As a guide, the table below shows some examples with the number of panels multiplied by selected panel widths. Solid dark line on chart indicates maximum frame height possible for a given maximum frame width. 8 6 (2600) For units with triple glazing, a horizontal mullion is needed for sizes beyond this line. Frame Height of Unit 8 2 (2500) 7 10 (2400) 7 6 (2300) 7 2 (2200) 6 10 (2100) and less 1 2 3 2 3 (700) 4 7 (1400) 6 10 (2100) Frame Width of Unit 2 7 (800) 5 3 (1600) 7 10 (2400) 2 11 (900) 5 10 (1800) 8 10 (2700) 3 3 (1000) 6 6 (2000) 9 10 (3000) A. Either for confi gurations with folding panels only or for confi gurations with folding panels and a swing door hinged to a side jamb includes Models 1L, 1R, 1L1R, 2R, 1L2R, 4R, 1L6R, 2L2R, 1L4R, 2L4R, 6R 2L6R, 4L4R, 4L6R, 2L, 2L1R, 4L, 4L1R, 4L2R, 6L,6L1R, 6L2R, 6L4R, & 6L6R B. For all confi gurations. If larger sized panels are needed, please consider the SL70 system. The maximum size limits shown are based on the weight of a panel that has a net glass thickness of 8-9 mm (~5/16"). The composition of 15/16" (24 mm) double insulated glass is 5/32" (4mm) glass x 2. The composition of 1 1/2" (38 mm) triple insulated glass is 1/8" (3 mm) glass x 3. For other net glass thickness, this maximum size limit chart will not apply. For confi gurations with no swing panels, the minimum panel width needed is 2'1" (625 mm). NUMBER OF PANELS IN UNIT 4 5 6 7 8 9 9 2 (2500) 11 5 (3500) 13 10 (4200) 16 (4900) 18 4 (5600) 20 7 (6300) 10 6 (3200) 13 1 (4000) 15 8 (4800) 18 4 (5600) 20 11 (6400) 23 6 (7200) 11 9 (3600) 14 9 (4500) 17 8 (5400) 20 7 (6300) 23 6 (7200) 26 5 (8100) 13 1 (4000) 16 4 (5000) 19 8 (6000) 22 10 (7000) 26 1 (8000) 29 4 (9000) 10 22 10 (7000) 26 1 (8000) 29 4 (9000) 32 9 (10000) 11 25 1 (7700) 28 8 (8800) 32 5 (9900) 36 1" (11000) 12 27 4 (8400) 31 5 (9600) 35 5 (10800) 39 4" (12000) 6 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

SL60 Maximum Size Chart (with different number of panels) Frame Height of Unit 9'6" (2900) 9 2 (2800) 8 10 (2700) 8 6 (2600) 8 2 (2500) 7 10 (2400) 7 6 (2300) COMMERCIAL NOTE: English dimensions are approximate. Dimensions in parenthesis are in millimeters Up to twelve panels are possible in a unit. Any custom panel size is possible up to the maximum size shown. The total overall unit width is the number of panels multiplied by the individual panel width. As a guide, the table below shows some examples with the number of panels multiplied by selected panel widths. Solid dark line on chart indicates maximum frame height possible for a given maximum frame width. For units with triple glazing, a horizontal mullion is needed for sizes beyond this line. For confi gurations with folding panels only includes Models 2R, 4R, 2L2R, 2L4R, 6R 2L6R, 4L4R, 4L6R, 2L, 4L, 4L2R, 6L, 6L2R, 6L4R, & 6L6R If larger sized panels are needed, please consider the SL70 system. 7 2 (2200) 6 10 (2100) and less 2 4 4 7 (1400) 9 2 (2500) Frame Width of Unit 5 3 (1600) 10 6 (3200) 5 10 (1800) 11 9 (3600) 6 6 (2000) 13 1 (4000) The maximum size limits shown are based on the weight of a panel that has a net glass thickness of 8-9 mm (~5/16"). The composition of 15/16" (24 mm) double insulated glass is 5/32" (4 mm) glass x 2. The composition of 1 1/2" (38 mm) triple insulated glass is 1/8" (3 mm) glass x 3. For other net glass thickness, this maximum size limit chart will not apply. For confi gurations with no swing panels, the minimum panel width needed is 2'1" (625 mm). 6 13 10 (4200) 15 8 (4800) 17 8 (5400) 19 8 (6000) 8 18 4 (5600) 20 11 (6400) 23 6 (7200) 26 1 (8000) 10 22 10 (7000) 26 1 (8000) 29 4 (9000) 32 9 (10000) 12 27 4 (8400) 31 5 (9600) 35 5 (10800) 39 4" (12000) SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 7

SL60 Relationship of Frame, Panel and Glass Daylight Opening Sizes Dimensions in millimeters unless noted. Calculation applies to the standard stiles and rails. Glass dimensions of all panels in a unit are equal. Nominal Panel Height (PH) is defined as Glass Daylight Opening Height + 120 ( 4 3/4 ). Nominal Panel Width (PW) is defined as Glass Daylight Opening Width + 120 (4 3/4 ). Panel Height is as seen from the inside on an inward opening unit and is as seen from the outside on an outward opening unit. Please note that with the overlap of the head jamb and the sill with the panel, the Clear Opening Height will not be the same as the Panel Height. See Cross-Section Details of both stiles of each panel to determine actual Panel Width. With astragals, overlapping, etc., the actual Panel Width not only varies with position of panel in a configuration, but the inside and outside surface widths of each stile may be different. For each configuration, the Frame Width (FW) is the sum of the nominal Panel Width (PW) x the number of panels + a number (N) which is the sum of the side jamb dimensions and dimensions of space between panels in excess of the nominal Panel Width as shown in the Cross-Section Details. Frame Height (FH) SL60/o Top Hung System Raised Sill : Frame Height = Panel Height + 149 (5 7/8 ) = Clear Opening Height + 165 (6 1/2 ) Flush Sill: Frame Height = Panel Height + 149 (5 7/8 ) = Clear Opening Height + 150 (5 7/8 ) Low Profile Saddle Sill: Frame Height = Panel Height + 149 (5 7/8 ) = Clear Opening Height + 150 (5 7/8 ) Frame Height (FH) SL60/u Floor Mounted System Raised Sill : Frame Height = Panel Height + 114 (4 1/2 ) = Clear Opening Height + 130 (5 1/8 ) Flush Sill: Frame Height = Panel Height + 114 (4 1/2 ) = Clear Opening Height + 115 (4 1/2 ) Low Profile Saddle Sill: Frame Height = Panel Height + 114 (4 1/2 ) = Clear Opening Height + 115 (4 1/2 ) Frame Widths for Different Configurations with Majority of Panels Folding to Right (and their Mirror Image Configurations with Majority of Panels Folding to Left). See Maximum Size Charts for size limits. These numbers can be used as a guideline only. Contact NanaWall for the exact calculations for a particular unit. Please note that widths for units with unhinged panels or angle turns will be different. Model 1R Frame Width = 1 x Panel Width +133 = 1 x Panel Width + 5 1/4 Model 1L1R Frame Width = 2 x Panel Width +147 = 2 x Panel Width + 5 13/16 Model 2R Frame Width = 2 x Panel Width + 175 = 2 x Panel Width + 6 7/8 Model 3R Frame Width = 3 x Panel Width + 154 = 3 x Panel Width + 6 1/16 Model 1L2R Frame Width = 3 x Panel Width + 187 = 3 x Panel Width + 7 3/8 Model 4R Frame Width = 4 x Panel Width + 196 = 4 x Panel Width + 7 11/16 Model 1L3R Frame Width = 4 x Panel Width + 168 = 4 x Panel Width + 6 5/8 Model 2L2R Frame Width = 4 x Panel Width + 229 = 4 x Panel Width + 9 Model 5R Frame Width = 5 x Panel Width + 175 = 5 x Panel Width + 6 7/8 Model 1L4R, Model 2L3R Frame Width = 5 x Panel Width + 208 = 5 x Panel Width + 8 3/16 Model 3L3R, Model 1L5R Frame Width = 6 x Panel Width + 189 = 6 x Panel Width + 7 7/16 Model 2L4R Frame Width = 6 x Panel Width + 250 = 6 x Panel Width + 9 13/16 Model 6R Frame Width = 6 x Panel Width + 217 = 6 x Panel Width + 8 9/16 Model 3L4R, Model 2L5R, 1L6R Frame Width = 7 x Panel Width + 228 = 7 x Panel Width + 9 Model 4L4R, 2L6R Frame Width = 8 x Panel Width + 270 = 8 x Panel Width + 10 5/8 Model 3L5R Frame Width = 8 x Panel Width + 209 = 8 x Panel Width + 8 1/4 Model 4L5R, Model 3L6R Frame Width = 9 x Panel Width + 249 = 9 x Panel Width + 9 13/16 Model 5L5R Frame Width = 10 x Panel Width + 230 = 10 x Panel Width + 9 1/16 Model 4L6R Frame Width = 10 x Panel Width + 291 = 9 x Panel Width + 11 7/16 Model 5L6R Frame Width = 11 x Panel Width + 270 = 11 x Panel Width + 10 5/8 Model 6L6R Frame Width = 12 x Panel Width + 312 = 12 x Panel Width + 12 1/4 8 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Inward Opening Section Details Detail 12.0 (SL60/0) Top Hung Head Jamb Detail 22.0 Low Profile Saddle Sill (SL60/o) (For resistance against wind driven rain, drain connections by others necessary) FFH Detail 23.0 Surface Mounted Interior Sill Frame Height FFH Detail 26.0 Flush Sill (SL60/o) (No rating against wind driven rain.) Detail 2.0 Raised Sill (higher weather performance sill) (SL60/o) FFH SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 9

SL60 Inward Opening Section Details All Cross Sectional Views Are Half Size Detail 1.0 Floor Mounted Head Jamb (SL60/u) Detail 21.0 Raised Sill (higher weather performance sill) (SL60/u) Frame Height Detail 28.0 Low Profile Saddle Sill (SL60/u) (For resistance against wind driven rain, drain connections by others necessary.) Detail 27.0 Flush Sill (SL60/u) (No rating against wind driven rain) FFH FFH 10 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Inward Opening Section Details Detail 4.0 Swing panel with locking at left side jamb Detail 4R.0 Swing panel with locking at right side jamb Detail 3R.0 Panel hinged at left side jamb Detail 3.0 Panel hinged at right side jamb Detail 7R.0 Left folding panel with locking Detail 7.0 Right folding panel with locking SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 11

SL60 Inward Opening Section Details All Cross Sectional Views Are Half Size Detail 7RC.0 Left folding panels with running carriage set Detail 7C.0 Right folding panel with running carriage set Detail 8.0 Two swing panels with locking: left panel opening first Detail 8R.0 Two swing panels with locking: right panel opening first 12 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Inward Opening Section Details Detail 5.0 Panel with running carriage set meeting left side jamb Detail 5R.0 Panel with running carriage set meeting right side jamb Detail 9.0 Meeting of panels folding to opposite sides (no swing panel) running carriage sets on both panels SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 13

SL60 Outward Opening Section Details All Cross Sectional Views Are Half Size Detail 9R.0 Meeting of panels folding to opposite sides (no swing panel) running carriage sets on both panels Detail 10R.0 Meeting of swing panel with locking on right and folding panel with running carriage set on left Detail 10.0 Meeting of swing panel with locking on left and folding panel with running carriage set on right 14 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size Detail 12.1 Top Hung Head Jamb (SL60/o) SL60 Outward Opening Section Details Detail 22.1 Low Profile Saddle Sill (SL60/o) (For resistance against wind driven rain, drain connections by others necessary) FFH Detail 23.1 Surface Mounted Interior Sill Frame Height FFH Detail 26.1 Flush Sill (SL60/o) (No rating against wind driven rain.) Detail 2.1 Raised Sill (higher weather performance sill) (SL60/o) FFH SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 15

SL60 Outward Opening Section Details All Cross Sectional Views Are Half Size Detail 1.1 Floor Mounted Head Jamb (SL60/u) Detail 21.1 Raised Sill (higher weather performance sill) (SL60/u) Detail 28.1 Floor mounted low profile sill (SL60/u) (For resistance against wind driven rain, drain connections by others necessary) Detail 27.1 Flush Sill (SL60/u) (No rating against wind driven rain) Frame Height FFH FFH 16 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Outward Opening Section Details Detail 4.1 Swing panel with locking at left side jamb Detail 4R.1 Swing panel with locking at right side jamb Detail 3R.1 Panel hinged at left side jamb Detail 3.1 Panel hinged at right side jamb Detail 7R.1 Left folding panels with locking Detail 7.1 Right folding panels with locking SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 17

SL60 Outward Opening Section Details All Cross Sectional Views Are Half Size Detail 7RC.1 Left folding panels with running carriage set Detail 7C.1 Right folding panels with running carriage set Detail 8.1 Two swing panels with locking: left panel opening first Detail 8R.1 Two swing panels with locking: right panel opening first 18 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Outward Opening Section Details Detail 5R.1 Panel with running carriage set meeting right side jamb Detail 5.1 Panel with running carriage set meeting left side jamb Detail 9.1 Meeting of panels folding to opposite sides (no swing panel) running carriage sets on both panels SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 19

SL60 Outward Opening Section Details All Cross Sectional Views Are Half Size Detail 9R.1 Meeting of panels folding to opposite sides (no swing panel) running carriage sets on both panels Detail 10.1 Meeting of swing panel with locking on left and folding panel with running carriage set on right Detail 10R.1 Meeting of swing panel with locking on right and folding panel with running carriage set on left 20 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Inward Opening Suggested Typical Installation SL60/o Head Jamb INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, fl ashing, waterproofi ng, sealant, trim and other details for specifi c surrounding conditions must be properly designed and provided by others. Installation Considerations The approximate weight of a panel with double-glazing is 5.5 lbs/ft 2, and with triple glazing is 6 lbs/ft 2. The vertical structural defl ection of the header should be the lesser of L/720 of the span and ¼ under full loads. Although for fl oor mounted systems, there is no vertical load on the header from the panels, structural support for lateral loads (both windload and when the panels are stacked open) must be provided. See Pre-Installation Preparation and Installation Guidelines in the General Introduction. An owner s manual with installation instructions is available upon request. Suggested Rough Opening From Subfloor Frame Height SL60/o Standard Raised Sill (higher weather performance sill) It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building's live load can be used to meet the above requirements of L/720 or 1/4. If not, both the dead and live loads need to be considered. For the fl oor mounted SL60u, please note that there is no vertical load on the header. Panel Hinged At Right Side Jamb SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 21

SL60 Inward Opening Suggested Typical Installation All Cross Sectional Views Are Half Size SL60/o Standard Window Sill SL60/o Alternate - Raised Sill (higher weather performance sill) with Sub Sill SL60/o Alternate - Raised Sill (higher weather performance sill) - Recessed INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, fl ashing, waterproofi ng, sealant, trim and other details for specifi c surrounding conditions must be properly designed and provided by others. 22 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Suggested Typical Installation Outward Opening Standard SL60/u Head Jamb INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, fl ashing, waterproofi ng, sealant, trim and other details for specifi c surrounding conditions must be properly designed and provided by others. Inward Opening SL60/u Head Jamb SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 23

All Cross Sectional Views Are Half Size SL60 Suggested Typical Installation INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, fl ashing, waterproofi ng, sealant, trim and other details for specifi c surrounding conditions must be properly designed and provided by others. Flush Sill (SL60/o) (No rating against wind driven rain) *Low Profile Saddle Sill for Inward or Outward Opening For resistance against wind driven rain, the following is recommended by others: 1. Remove the gasket covering the inner channel. 2. Provide necessary weepholes at the bottom of channels and on the outside face of the sill. 3. Make necessary drain connections. Ask NanaWall for a detailed drawing. Low Profile Saddle Sill* (SL60/o) FFH FFH Surface Mounted Interior Sill FFH FFH 24 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL60 Suggested Typical Installation INSTALLATION NOTES SL60/o Head Jamb Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, fl ashing, waterproofi ng, sealant, trim and other details for specifi c surrounding conditions must be properly designed and provided by others. Installation Considerations The approximate weight of a panel with double-glazing is 5.5 lbs/ft 2, and with triple glazing is 6 lbs/ft 2. The vertical structural defl ection of the header should be the lesser of L/720 of the span and ¼ under full loads. Although for fl oor mounted systems, there is no vertical load on the header from the panels, structural support for lateral loads (both windload and when the panels are stacked open) must be provided. See Pre-Installation Preparation and Installation Guidelines in the General Introduction. An owner s manual with installation instructions is available upon request. Suggested Rough Opening From Subfloor Frame Height SL60/o Standard Raised Sill (higher weather performance sill) It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building's live load can be used to meet the above requirements of L/720 or 1/4. If not, both the dead and live loads need to be considered. For the fl oor mounted SL60u, please note that there is no vertical load on the header. Panel Hinged at Right Side Jamb SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 25

As a guide, in low wind areas, a 3 high transom is possible with a 12 wide unit with Details 36 and 37. Note that the support profile must be anchored to the adjacent wall. For other applications, a structural beam will be needed between the folding unit and the fixed unit. Detail 36 Support profile between SL68 fixed transoms and SL60 unit for certain limited applications depending on size, configuration and structural loading Detail 37 Support profile between fixed windows and SL60 unit for certain limited applications depending on size, configuration and structural loading Typical Elevation: I-3L with fixed transoms Typical Elevation: I-3L with fixed bottom windows 36 37 26 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

Typical Mullion Profile Typical Glass Stop Profile with Triple Glazing Typical Simulated Divided Lites Muntins with Spacer Between Insulated Glass (SDL) SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 27

SL60 Guide Specifications - Section 084113 Design Windload Chart (Derived From Comparative Analysis) Test Unit Size: 9 5 W x 8 2 1/2 H (3 panels) 135 130 125 Please note that some jurisdictions may limit the use of these charts or may not accept them at all. Design pressures and/ or sizes may be restricted to what was tested. For Florida approved products, please see detailed FL Evaluation Report for restrictions. 120 115 110 105 Please also note that chart is only applicable for units with referenced Nana Wall supplied locking. 100 95 90 Positive and negative design pressures for both inward and outward opening units. Allowable Design Wind Loading - PSF 85 80 75 70 65 60 55 50 45 40 35 30 1 11 2 3 2 7 2 11 3 3 Unit Width Divided by Number of Panels 25 20 15 10 5 0 6 0 6 6 7 0 7 6 8 0 8 6 9 0 9 6 10 0 Panel Height See Maximum Frame Size Chart for Possible Sizes 28 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

Guide Specifications - Section 084113 SL60 NanaWall SL60, Thermally Broken Aluminum Framed Folding System PART 1 - GENERAL 1.01 SUMMARY Section Includes: Engineered sliding/folding aluminum and glass door system, including aluminum frame, threshold, panels, sliding/folding and locking hardware, weather stripping, glass and glazing; designed to provide an opening glass wall, with sizes and configurations as shown on drawings and specified herein, NanaWall SL60, Thermally Broken Aluminum Framed Folding System as supplied by NANA WALL SYSTEMS, INC. 1.02 REFERENCES A. American Architectural Manufactures Association (AAMA): 1. AAMA 611, Voluntary Specifi cation for Anodized Architectural Aluminum. 2. AAMA 2604, Voluntary Specifi cations, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels. 3. AAMA 1304, Voluntary Specifi cations for Forced Entry Resistance of Side-Hinged Door Systems. B. American National Standards Institute (ANSI): 1. ANSI Z97.1, Safety Performance Specifi cations and Methods of Test for Safety Glazing Material Used In Buildings. C. American Society for Testing and Materials (ASTM): 1. ASTM E 283, Test Method for Rate of Air Leakage through Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 2. ASTM E 330, Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 3. ASTM E 547, Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential. 4. ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference. D. Consumer Product Safety Commission (CPSC): 1. CPSC 16CFR-1201, Safety Standard for Architectural Glazing Materials. E. National Fenestration Rating Council (NFRC): 1. NFRC 100, Procedure for Determining Fenestration Product Thermal Materials. 2. NFRC 200, Procedure for Determining Solar Heat Gain Coeffi cient. 3. NFRC 400, Procedure for Determining Fenestration Product Air Leakage 1.03 SUBMITTALS A. Detail Drawings: Indicate dimensioning, direction of swing, confi guration, swing panels, typical head jamb, side jambs and sill details, type of glazing material, and handle height. B. Product Data: Manufacturer s literature including independently tested data listing performance criteria and Owner s Manual with installation instructions. C. Contract Closeout Submittal: Submit Owner s Manual from manufacturer. Identify with project name, location and completion date, type and size of unit installed. 1.04 QUALITY ASSURANCE A. Manufacturer: Provide complete, precision built, engineered, pre-fi tted unit by a single source manufacturer with at SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 29

SL60 Guide Specifications - Section 084113 least 25 years experience in providing folding/sliding door systems for large openings in the North American market. 1. The manufacturer must have a quality management system registration to the ISO 9001: 2008 standard. B. Performance Requirements: Provide from manufacturer that has independently tested typical units. Testing results to include air infi ltration in accordance with ASTM E 283 and NFRC 400, water penetration in accordance with ASTM E 547 and E 331, structural loading in accordance with ASTM E 330, and forced entry in accordance with AAMA 1304. SPECIFIER S NOTE: Air infiltration and water penetration testing results can only be applicable if the unit matches the test unit in the direction of opening and the type of sill. Structural load testing results are only applicable for the test unit size, type of locking and type of mounting. (Comparative analysis charts published by manufacturer show which panel sizes (if any) would meet structural loading design pressures specifically required for the project. Check for limitations on the use of these charts in the jurisdiction of the project). Forced entry testing results are only applicable for the test unit type of locking. See manufacturer s latest published data. C. Thermal Performance U factor: Unit to be rated, certifi ed and labeled in accordance with NFRC 100, shown in manufacturer s latest published data for the glazing, sill, and direction of opening specifi ed. D. Solar Heat Gain Coeffi cient: Unit to be rated, certifi ed and labeled in accordance with NFRC 200, shown in manufacturer s latest published data for the glazing, sill, and direction of opening specifi ed. SPECIFIER NOTE: If desired, Energy Star ratings can be achieved by the use of proper glass with the unit. See NanaWall s Performance data for details. E. Installer Qualifi cations: Installer experienced in the installation of manufacturer s products or other similar products for large openings. Installer to provide reference list of at least 3 projects of similar scale and complexity successfully completed in the last 3 years. 1.05 WARRANTY A. Provide manufacturer s standard warranty against defects in materials and workmanship. B. Warranty Period: Ten years for rollers and for seal failure of insulated glass supplied. For all other components, one year (two years if unit is installed by manufacturers certifi ed trained installer) from date of delivery by manufacturer. 1.06 SITE CONDITIONS, DELIVERY, STORAGE AND HANDLING A. In addition to general delivery, storage and handling requirements specifi ed in Section 01600, comply with the following: 1. Deliver materials to job site in sealed, unopened cartons or crates. Protect units from damage. Store material under cover, protected from weather and construction activities. PART 2 - PRODUCTS 2.01 SUPPLIER A. NANA WALL SYSTEMS, INC. - SL60 100 Meadow Creek Drive, Corte Madera, CA 94925 Toll Free: (800) 873-5673 Telephone: (415) 383-3148 Fax: (415) 383-0132 Website: www.nanawall.com Email: info@nanawall.com B. Other suppliers equal to the specified product must submit substitution request two weeks before bid for prior approval. 30 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

Guide Specifications - Section 084113 SL60 2.02 MATERIALS A. Frame and Panels: From manufacturer s standard profi les, provide head track, side jambs, and panels with dimensions shown on drawings. 1. Provide panels with: Standard one lite [OR with horizontal mullion(s) at specifi ed height(s) from the bottom of the panel] [OR with simulated divided lites in pattern as shown on drawings]. 2. Provide standard bottom rail. 3. Aluminum Extrusion: Extrusions with nominal thickness of.078 (2.0 mm). Alloy specifi ed as AIMgSi0.5 with strength rated as 6063-T5 or F-22 (European standard). Anodized conforming to AAMA 611 or powder coated conforming to AAMA 2604. 4. Thermally broken with a wide Polyamide plastic reinforced with glass fi bers. Polyamide plastic less than 7/8" (22 mm) wide or pour and de-bridge thermal break will not be accepted. 5. Aluminum Finish: B. Glass: Select from NanaWall Powder Coating Finish Chart [OR clear anodized] [OR select from range of RAL high gloss powder coated fi nishes available from manufacturer] [OR select from range of RAL matte powder coated fi nished available from manufacturer] [OR custom fi nish} Same [OR different] fi nishes on inside and outside 1. All glass to comply with safety glazing requirements of ANSI Z97.1 and CPSC 16CFR 1201. Provide manufacturer s standard glass with dry glazing with glass stops on the inside only: 15/16 (24 mm) insulating clear safety [OR 15/16 (24 mm) insulating argon fi lled Low-E safety] [OR 15/16 (24 mm) insulating krypton fi lled Heat Mirror TC88 safety] [OR 1 1/2" (38mm) triple insulating argon fi lled Low-E safety] [OR other glass available from manufacturer, including glass with other total thickness] 2. Provide manufacturer s standard glass spacers. Provide without capillary tubes [OR with capillary tubes]. C. Locking Hardware and Handles: 1. Main entry panel: On the main entry panel for models with a pair of swing panels, provide manufacturer s standard lever handles on the inside and outside, a Schlage compatible lock set with lockable latch, multi-point locking with a dead bolt and rods at the top and bottom on primary panel. Rods to be concealed and not edge mounted. After turn of key or thumbturn, depression of handles withdraws latch. Lifting of handles engages rods and turn of key or thumb turn engages deadbolt and operates lock. On the secondary swing panel, provide matching dummy lever handles on both sides and concealed fl ush bolts that operate the rods at the top and the bottom for the secondary swing panel. Stainless steel lever handles in a titanium black fi nish [OR stainless steel lever handles in a brushed satin fi nish] [OR oil rubbed bronze solid brass lever handles] [OR satin nickel solid brass lever handles] [OR white solid brass lever handles] [OR on the main entry panel for models with a swing panel, provide manufacturer s standard lever SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2013 NanaWall Systems www.nanawall.com 31

SL60 Guide Specifications - Section 084113 handles on the inside and outside, a Schlage compatible lock set with lockable latch, multi-point locking with a dead bolt and rods at the top and bottom on primary panel only. Rods to be concealed and not edge mounted. After turn of key or thumbturn, depression of handles withdraws latch. Lifting of handles engages rods and turn of key or thumb turn engages deadbolt and operates lock. If there is a secondary swing panel, provide two point locking with fl at handles on inside only for the secondary swing panel. Stainless steel lever handles in a titanium black fi nish [OR stainless steel lever handles in a brushed satin fi nish] [OR oil rubbed bronze solid brass lever handles] [OR satin nickel solid brass lever handles] [OR white solid brass lever handles] [OR on main entry pair of panels on inswing models without a swing panel, provide manufacturer s standard L-shaped handle on the inside, fl at handle on the outside and lock set with profi le cylinder. Operation of lock set is by turn of key from the outside and with a thumbturn from the inside with a two point locking hardware operated by 180º turn of the handle.] Stainless steel L shaped handles in a titanium black fi nish [OR stainless steel L shaped handles in a brushed satin fi nish] [OR L shaped handles in a brown nylon fi nish] [OR L shaped handles in a gray nylon fi nish] [OR L shaped handles in a white nylon fi nish] [OR on main entry pair of panels on outswing models without a swing panel, provide manufacturer s standard fl at handle on the inside and on the outside and a lock set with a profi le cylinder. Operation of lock set is by turn of key from the outside and from the inside with a two point locking hardware operated by 180º turn of the handle. SPECIFIER S NOTE: Key operation from the inside may not meet egress requirements.] [OR on main entry panel, provide manufacturer s standard fl at handle on inside only with concealed two point locking hardware operated by 180 degree turn of handle. SPECIFIER S NOTE: Note that with this option, the main entry panel is operable from inside only and that there is no latch.] SPECIFIER S NOTE: Note that other compatible lever handle styles and finishes are available from other suppliers.] 2. On all other secondary swing panels and pairs of folding panels, provide manufacturer s standard fl at handles and concealed two point locking hardware operated by 180 degree turn of handle between each pair. Face applied flush bolt locking will not be allowed. 3. Flat Handle Finish: Stainless steel in a titanium black fi nish [OR stainless steel in a brushed satin fi nish] [OR closest powder coat match to aluminum profi le fi nish] Provide handle height centered at 41 3/8 [OR as specifi ed] from bottom of panel. Aluminum locking rods with fi ber glass reinforced polyamide end caps at top and bottom. Rods to have a stroke of 15/16 (24 mm). If there are more than one unit, keyed alike [OR keyed differently]. D. Sliding/Folding Hardware: Provide manufacturer s standard combination sliding and folding hardware with top, bottom tracks and threshold. All running carriages to be with sealed, self-lubrication, ball bearing multi-rollers. Surface mounted hinges and running carriages will not be allowed. Weight of panels to be borne by the bottom of the guide channel in the sill will not be allowed. 1. For each pair of folding panels: For top hung system SL60/o, provide cardanic, independently suspended, four wheeled coated with fiber glass rein- 32 2013 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.