Utilizing Glow Discharge in Optical Emission Spectroscopy

Similar documents
Glow discharge optical emission spectroscopy: a general overview with regard to nuclear materials

Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Analysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000

Optical Emission Spectrometers

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Fusion

ANALYTICAL PERFORMANCE OF A HANDHELD EDXRF SPECTROMETER WITH MINIATURE X-RAY TUBE EXCITATION

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Thickness and composition analysis of thin film samples using FP method by XRF analysis

Analysis of Cast Iron Using Shimadzu PDA-7000

Analysis of 14 Trace Elements in Stainless Steel

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Surface chemical analysis Analysis of zinc- and/or aluminium-based metallic coatings by glow-discharge optical-emission spectrometry

Chemistry and Chemical Sampling Updated 2012

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Analysis of Trace Metals in Tobacco and Tobacco Ash using Atomic Emission Spectroscopy

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

Thin Films: Sputtering Systems (Jaeger Ch 6 & Ruska Ch 7,) Can deposit any material on any substrate (in principal) Start with pumping down to high

Wavelength-dispersive X-ray fluorescence spectrometer

Jacques Matteau. NanoBond Assembly: A Rapid, Room Temperature Soldering Process. Global Sales Manager. indium.us/f018

Certificate of Analysis BS 110B

Sensortherm. Digital Pyrometer. Temperature Measurement and Control. com

Using Guard Bands to Accommodate Uncertainty in the Spark AES Analysis of Aluminum or Aluminum Alloys When Determining Compliance with Specified

Linear Plasma Sources for Surface Modification and Deposition for Large Area Coating

Composition Analysis of Animal Feed by HR ICP-OES

Thin Films: Sputtering Systems (Jaeger Ch 6 & Ruska Ch 7,) Sputtering: gas plasma transfers atoms from target to substrate Can deposit any material

EECS130 Integrated Circuit Devices

SEMASPEC Test Method for Metallurgical Analysis for Gas Distribution System Components

STUDY OF ELEMENT FINGERPRINTING IN GOLD DORÉ BY GLOW DISCHARGE MASS SPECTROMETRY

CS744 Series: Carbon/Sulfur by Combustion

CS744 Series: Carbon/Sulfur by Combustion

LOW TEMPERATURE PHOTONIC SINTERING FOR PRINTED ELECTRONICS. Dr. Saad Ahmed XENON Corporation November 19, 2015

16.2 Scanning Infrared Spectrometers

Microstructure Study of Diffusion Bonding of Centrifuged Structural Steel-Bronze

The New Wave in Spectroscopy FS-2 FluoroMate Fluorescence Spectrometer

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

MODEL SEM Mill. Two independently adjustable TrueFocus ion sources

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Amorphous Silicon Solar Cells

Transactions on Engineering Sciences vol 2, 1993 WIT Press, ISSN

Thin Films & AR Coated. Viewports. Thin Film & AR Coated. Viewports

ICP Expert software. Technical Overview. Introduction

MODEL TEM Mill. Two independently adjustable TrueFocus ion sources

Atomized Low Apparent Density (AD) Iron Powder For Advanced PM Applications

Vacuum deposition of TiN

PMI-MASTER Compact. Cost-effective, rugged and precise mobile metal analyser. Routine analysis at entry level. Easy and fast testing

The principle Of Tungsten Inert Gas (TIG) Welding Process

WELDING Topic and Contents Hours Marks

AC Reactive Sputtering with Inverted Cylindrical Magnetrons

Spectroscopy Solutions for Pharmaceuticals:

Chapter 3 Silicon Device Fabrication Technology

Combinatorial RF Magnetron Sputtering for Rapid Materials Discovery: Methodology and Applications

Photonic Drying Pulsed Light as a low Temperature Sintering Process

Optical Coatings. Photonics 4 Luxury Coatings , Genève. Dr. Andreas Bächli Head of Optical Coatings at RhySearch, Buchs (SG)

Dissimilar Metals DISSIMILAR METALS. Weld Tech News VOL 1. NO. 14

MODEL 1051 TEM Mill ION MILLING. Ion milling is used on physical science. specimens to reduce thickness to electron

Korkealämpötilaprosessit

- HSS-Blade (EOS art.-no ) - 90 µm mesh for powder sieving recommended (EOS art.-no ) - Argon atmosphere

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Advanced Analytical Techniques for Semiconductor Assembly Materials and Processes. Jason Chou and Sze Pei Lim Indium Corporation

Advances in Intense Pulsed Light Solutions For Display Manufacturing. XENON Corporation Dr. Saad Ahmed Japan IDW 2016

UTILIZATION OF ATMOSPHERIC PLASMA SURFACE PREPARATION TO IMPROVE COPPER PLATING PROCESSES.

Evaluation of Energy-Dispersive X-Ray Fluorescence for Mobile Analysis of Hazardous Metals in Transuranic Waste

Understanding Coating Thickness Measurement Helmut Fischer

Chapter 3 Shielded. Metal Arc Welding

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

EML 2322L -- MAE Design and Manufacturing Laboratory. Welding

Chemical Analysis SEM/EDS. Spectroscopy. Carbon, Sulfur, Nitrogen and Oxygen Analysis

AMETAL AMETAL AMETAL APPLICATIONS GENERAL

UPDATED CASE STUDY OF FIRESIDE CORROSION MANAGEMENT IN AN RDF FIRED ENERGY-FROM-WASTE BOILER

Sputter Coating. Technical Brief

GB Translated English of Chinese Standard: GB

Cleaning Validation PRODUCT OVERVIEW

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

2.3. Continuous Hot-Dip Galvanizing versus General (Batch) Galvanizing REV 1.1 DEC GalvInfoNote. Introduction. Continuous Galvanizing

Thermal Evaporation. Theory

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Certificate of Analysis

CONTROL OF Ca IN STEELS USING SPARK DATA TECHNIQUE

X-ray Photoelectron Spectroscopy

Small-Scale Resistance Welding for Medical and Industrial Applications

Depth-resolved analysis of Ni P plated aluminium hard disks by radiofrequency glow discharge optical emission spectroscopy (rf-gd-oes)

Low drift Type K and N Mineral Insulated thermocouples for high temperature applications. Dr. Michele Scervini Trevor D Ford. CCPI Europe Limited

Thermocouple Quick Reference Guide. Aluminium Temperature Sensing Solutions from the Smelter to the Foundry

Get your hands on. And get results in a flash.

Trust but verify: Ensure product quality at all stages of production

TUTORIAL ON SPUTTER DEPOSITION

EUROPEAN PRECISION AND QUALITY SAWS HIGH SPEED STEEL, COBALT & CARBIDE METAL CUTTING SAWS

Heat Treating Copper Beryllium Parts

Certificate of Analysis

NIRS DS2500 flour analyser

Transcription:

Frequently Asked Questions Utilizing Glow Discharge in Optical Emission Spectroscopy

Introduction For over 70 years, industries around the world have trusted LECO Corporation to deliver technologically advanced solutions. Our state-of-theart research and development center includes teams of engineers working together to create and test ideas that will be incorporated into your next instrument an instrument designed to meet your needs. At our in-house manufacturing facility, quality drives production. From stamped metal parts to complex electronic assemblies, LECO produces most of the components needed in our products, allowing strict control over the entire manufacturing process in accordance with the quality standards of ISO-9001:2000. As a final check before shipping, your instrument is thoroughly tested to assure quality and functionality. With dedicated support after the sale including highly trained service support personnel, customer training courses, SmartLine Remote Diagnostics, preventive maintenance agreements, and a full line of consumables and spare parts, LECO stands by our commitment of helping you achieve the right results. LECO World Headquarters St. Joseph, MI

What is Glow Discharge Optical Emission? Glow Discharge Spectroscopy (GDS) is an analytical technique used to measure the elemental concentrations of solid materials. A stream of argon ions mills material from the sample surface. The sputtered material is then excited in a low pressure plasma discharge and resulting Excited Sample Atom Ground Energy Ar Atom light emission is used to Sample Atom High Energy Ar Atom + Argon Ion characterize and quantify the sample's composition. Glow Discharge offers an improved excitation source for fast, economical, accurate, and reliable sample turnaround. This source uniformly removes material from the sample surface which reduces the effects of metallurgical and chemical history inherent in all samples. Is Glow Discharge a new technology? No, the Glow Discharge source has been known since the late 1800s. The Grimm-type lamp, originally developed in 1967, is typically employed to produce the analytical emission signal required for analysis. This style lamp, utilized in all LECO GDS spectrometers, allows for quick sample turnaround. What advantages does a Glow Discharge spectrometer offer? Freedom from metallurgical history Analysis of difficult materials Limited matrix effects (as-cast iron, low melting point alloys) Linear working curves Automatic cleaning between samples Minimal spectral interferences Low reference material and gas Excellent precision consumption Technology & Source Where is the spectrometer manufactured and what type of support is available? All LECO GDS spectrometers are manufactured at the Corporation's World Headquarters in St. Joseph, MI, USA. This site also serves as the primary location for Research and Development. LECO's complete line of analytical instrumentation is supported by specialized sales, service, and applications staffs located in over 50 domestic and international offices.

My recent Glow Discharge demo showed notable improvements in precision over spark data. In addition, Glow Discharge showed significantly fewer inter-element and line overlap interferences. Why is this possible? Glow Discharge is a low pressure, non-thermal source that sputters the material uniformly from the sample surface. The excitation of primarily atom lines occurs away from the sample surface resulting in reduced metallurgical effects and linear calibration curves. Foundries have used spark-type spectrometers for years; however, difficult materials like as-cast iron, leaded resulfurized steels, and low melting point alloys cannot be run successfully by spark. Why is Glow Discharge able to analyze these materials? GDS does not preferentially attack the sample surface. Iron, carbon, and oxide inclusions are sputtered uniformly across the sample surface. This is also true for elements which may not be in solid solution, like sulfur and lead. Since GDS is a non-thermal sampling process, low melting point alloys like solder, Pb, Zn, and Sn are successfully analyzed. Our company runs six different matrices. Other spectrometer manufacturers have proposed as many as 38 analytical channels. Why are fewer channels required for your Glow Discharge spectrometer? Due to the excitation of primarily atom lines, LECO GDS spectrometers provide linear calibrations and wide dynamic ranges. For example, the same analytical line chosen for one material can easily be used as the matrix line for another material. Fewer lines are necessary to analyze a broad range of materials. Features & Performance When we change matrices with our current spectrometer, we must change electrodes and clean the stand to avoid cross contamination. How is this problem handled with LECO's Glow Discharge spectrometers? The Grimm-type GDS lamp manufactured by LECO utilizes an automatic, software-controlled reamer to clean and eliminate cross contamination. Does Glow Discharge have the same accuracy problems as spark spectrometers with carbon concentrations over 0.25%? No, problems inherent to spark-type spectrometers (i.e. vaporization temperatures) do not exist with LECO engineered GDS systems across this analytical range. How can the LECO GDS-400A, with a 0.4 meter focal length, offer similar performance to competitive models with 0.75 meter and 1.0 meter focal lengths? Limited spectral interferences due to narrow emission lines and the excitation of primarily atom lines assure the spectra is simpler.

Can you show me some examples of linearity covering a wide concentration range? C in Ferrous-based Method Ni in Copper-based Method 4.6 Carbon in Ferrous Materials 36 Nickel in Copper Alloys 3.7 29 1.8 Certified2.8 Certified 22 15 0.9 7 0.0 0.0 0.18 0.37 0.55 0.74 0.91 Corrected 0 0.0 0.6 1.2 1.8 2.4 3.0 Corrected How do you analyze small samples? Wire samples, as small as 0.010 inches (0.25 mm) in diameter, have been successfully tested by "packing" them together. Thin sheet, down to 0.002 inches (0.05 mm) in thickness, has been run by the use of a backplate or optional cooling puck. What is the Ar gas usage? Typically, total consumption during an analysis is less than 1 liter. How much sample is removed during a bulk analysis? Material is sputtered uniformly to a depth of approximately 100 to 200 micrometers. In cast iron, about 100 to 150 micrograms are removed. What sample preparation is required by Glow Discharge for bulk analysis? Most often, a 120 grit surface is easily prepared on a belt or disc grinder. What is meant by multi-scan and how is it used? Multi-scan allows an operator to scan to either side of an analytical line creating the opportunity to measure additional wavelengths close to the existing analytical lines, while maintaining optical integrity. True background correction is an additional feature. Multi-scan and background correction are offered exclusively on the GDS850A model.

Surface Analysis & Non-conductive Materials When we use Quantitative Depth Profile (QDP) Analysis, what resolution and precision can we achieve? Analyses start as low as 10 nm into the surface. Thickness of uniformly coated materials is routinely determined within 5% RSD. How deep can the GDS sputter go for QDP? Depths from tens of nanometers to 100 micrometers are typical. This varies with the sample type. How long does it take to do a multi-element depth analysis? Anywhere from 30 seconds to five minutes. This depends on your sample type. For example, electrogalvanized material typically ranges one to two minutes per analysis. Can Glow Discharge analyze non-conductive materials? Yes, this is typically achieved with an RF source available on the LECO GDS850A and SA-2000 models. This is necessary for non-conductors. LECO GDS Product Line LECO GDS500A Bulk Analysis Specifications Optics: CCD-based, simultaneous vacuum spectrometer Spectral Range: 165 to 460 nm complete spectral coverage Source: 4 mm DC standard (2 mm optional) LECO GDS850A Bulk and Depth Profile Analysis Specifications Optics: 0.75 meter simultaneous vacuum spectrometer; dual source compatible Spectral Range: 120 to 800 nm Resolution: <0.025 nm over spectral range Channels: 58 maximum with background correction and multi-scan capabilities Source: 4 mm DC standard (2, 7 mm optional); 4, 2 mm RF optional Grating: 1800, 2400, 3600 groove/mm