Geogrid Soil Reinforcement

Similar documents
STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES. October 19, 2012

GEOSYTHETIC SLOPE SPEC-V0704rev.doc STANDARD SPECIAL PROVISION FOR GEOSYNTHETIC REINFORCED SLOPE CONSTRUCTION

DETERMINATION OF THE LONG TERM PROPERTIES FOR MIRAFI PET-SERIES REINFORCEMENT GEOTEXTILES BY GRI-GT7 AND NCMA GUIDELINES

DETERMINATION OF THE LONG-TERM PROPERTIES FOR MIRAGRID XT GEOGRIDS

Wall Modular Block Mechanically Stabilized Earth, Item S.

Celtik Pro TM Wall Spec

2010 NTPEP Report Series

Section ( ) SPECIFICATION FOR SEGMENTAL CONCRETE UNIT RETAINING WALL

GRI Standard Practice GG4(b) * "Determination of the Long-Term Design Strength of Flexible Geogrids"

MODULAR CONCRETE RETAINING WALL

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 836 SEEDING AND EROSION CONTROL WITH TURF REINFORCING MAT January 18, 2013

2014 NTPEP Report Series

This supplemental technical specification replaces Section 713 of the 2007 Standard Specifications for Highway Construction.

Section (02830) MODULAR CONCRETE RETAINING WALL

CONCRETE SEGMENTAL RETAINING WALLS

PROPOSAL PACKET CITY OF MASCOUTAH HUNTERS TRAIL PAVING. BID DATE: 9:00 a.m., August 31, 2017

ASTM D % 8.02% NA 1223 NA for App. Usage NA for App. Usage. NA for App. Usage. NA for App. Usage. NA for App.

02632 Segmental Concrete Retaining Wall System Page - 1

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

Recyclex TRM TURF REINFORCEMENT MAT SPECIFICATION

Appendix D REINFORCED SOIL SLOPES

SECTION 806 WATER COURSE AND SLOPE EROSION PROTECTION

Internal Design of Mechanically Stabilized Earth (MSE) Retaining Walls Using Crimped Bars

Use of Polymer Geogrid Composite to support rail track over weak saturated clay subgrade a case study

Construction of MSE Wall Using Tire Shred-sand Mixture as Backfill (SPR-3470)

10,000. Peak Connection Strength, lb/ft 8,000 6,000 4,000 2,000

QUALITY ASSESSMENT OF GEOGRIDS USED FOR SUBGRADE TREATMENT

Bureau of Materials Materials Approval Procedures

TensarTech TW1 Wall System Earth Retaining Structures

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

FORTRAC GEOSYNTHETICS FORTRAC T AND R-T GEOGRIDS

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

AEC Premier Straw Double Net Quick Mow EROSION CONTROL BLANKET SPECIFICATION

SEGMENTAL BLOCK RETAINING WALLS. Comply with Division 1 - General Provisions and Covenants, as well as the following:

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

ICC-ES Evaluation Report Issued July 1, 2011 This report is subject to renewal in one year.

Description. This work shall consist of furnishing materials and placement of modular block wall constructed in accordance with

INS T A LLA T I O N G U I D E

GEOSYNTHETIC-REINFORCED PAVEMENT SYSTEM : TESTING & DESIGN

Stability of a Mechanically Stabilized Earth Wall

PRODUCT SPECIFICATION CSI FORMAT Slope and Channel Grid Systems April 2009

Curlex Enforcer EROSION CONTROL BLANKET SPECIFICATION

RETAINING WALLS CHAPTER 13. Omitted parts: Section

Geoguide 6 The New Guide to Reinforced Fill Structure and Slope Design in Hong Kong

Geogrids for Roadway Applications

ASTM D % 9.21% NA 1302 NA for App. Usage NA for App. Usage. NA for App. Usage. NA for App. Usage. NA for App.

SUPPLEMENTAL SPECIFICATION HIGH PERFORMANCE CHIP SEAL

Study of Interlocking Effect by the Push Test

APPLICATION BULLETIN. TENSAR GRADE SEPARATION SOLUTIONS FOR HEAVY RAIL AND MASS TRANSIT l

Curlex High Velocity EROSION CONTROL BLANKET SPECIFICATION

DESIGN CONSIDERATIONS FOR NSWS NATURAL STONE RETAINING AND FREE-STANDING WALL SYSTEMS

ENGINEERING DIRECTIVE

Curlex II EROSION CONTROL BLANKET SPECIFICATION

Bearing Capacity of Footing on Reinforced Flyash Slope

Static Response of Reinforced Soil Retaining Walls with Modular Block Facing

Specifications for the Selection and Application of Erosion Control Blanket on Slopes or Channels

Confined-accelerated Creep Tests on Geosynthetics

GRI - GM17 Standard Specification*

FINAL REPORT: CONNECTION STRENGTH TESTING TENSAR GEOGRIDS WITHIN MESA STANDARD BLOCKS AND MESA STANDARD CONNECTORS

CITY OF FARGO SPECIFICATIONS AGGREGATE BASES

Chapter 18 EARTH RETAINING STRUCTURES

TECHNICAL REPORT STANDARD PAGE

ARMORMAX ENGINEERED EARTH ARMORING SOLUTIONS

SECTION AGGREGATES

GRI Standard GC8 * Determination of the Allowable Flow Rate of a Drainage Geocomposite

Best Practices for Allan Block Segmental Retaining Wall Design For Residential and Commercial Applications

PRECONSTRUCTION DESIGN MEMORANDUM CULVERT PIPE STRUCTURAL DESIGN CRITERIA FOR SCDOT FILL HEIGHT TABLES

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

TensarTech TW3 Wall System Earth Retaining Structures

A Validated Discrete Element Modeling Approach for Studying Geogrid-Aggregate Reinforcement Mechanisms

MECHANICALLY STABILIZED EARTH (MSE) WALL SYSTEMS

GRI-GCL3 Specification Geosynthetic Clay Liners (GCLs)

Solving Slope Protection Problems Geoweb Cellular Confinement System

BMP 6.4.4: Infiltration Trench

TION GUIDE ALLA T INS

Mechanically Stabilized Earth Structures By Blaise J. Fitzpatrick, P.E. Fitzpatrick Engineering Associates, P.C.

GRI-GM22 GM22 Specification Reinforced Polyethylene Geomembranes for Exposed Temporary Applications

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Warm Mix Asphalt (WMA)

MSE. Mechanically Stabilized Earth Systems. Permanent and Temporary MSE Walls Reinforced Soil Slopes Embankments

DIVISION: EXTERIOR IMPROVEMENTS SECTION: RETAINING WALLS SECTION: SEGMENTAL RETAINING WALLS REPORT HOLDER:

The design of reinforced soil retaining walls using TENAX geogrids

SECTION CAST-IN-PLACE CONCRETE

GEOSYNTHETICS FOR SOIL REINFORCEMENT

Qualified Product Policy 15 Drainage Structure Miscellaneous Components Qualified Product List 14 [G] Heavy Duty Gray Cast Iron

CAST IN PLACE TACTILE / DETECTABLE WARNING SURFACE TILES

LABORATORY TESTING OF MODULAR MASONRY CONCRETE BLOCK GEOGRID FAC- ING CONNECTIONS

Application of Mechanically Stabilized Earth Wall with Geo-synthetic Strap Soil Reinforcement for False Abutment Structures

ITEM 25 CHIP SEAL MATERIALS 2 A. Non-Polymer Modified Asphalt Emulsion (Fog Seal) 2 B. Polymer Modified Asphalt Emulsion Binder 2

A.Zh. Zhussupbekov, R.E.Lukpanov, A.Tulebekova, I.O.Morev,Y.B.Utepov 1 ) 1) Geotechnical Institute of L.N. Gumilyov Eurasian National University,

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

Bentofix continues to develop technological advantages for your industry.

SECTION EXCAVATION AND EMBANKMENT. B. Subbase Grading A samples for gradation analysis.

PCC Pavement Mix Proportioning and Strength

Geosynthetics Product & Application Quick Reference Guide

GABIONS AND REVET MATTRESSES

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

Transcription:

Supplemental Technical Specification for Geogrid Soil Reinforcement SCDOT Designation: SC-M-203-2 (4/16) 1.0 DESCRIPTION The requirements of this specification consist of furnishing all necessary submittals and materials for providing geogrid soil reinforcement in accordance with the details shown on the plans and the requirements of the Specifications, Special Provisions or as directed by the Resident Construction Engineer (RCE). For geogrid used for subgrade stabilization see Supplement Technical Specification for Geosynthetic Materials for Separation and Stabilization (SC-M-203-1). 2.0 TESTING STANDARDS 2.1 Use the latest edition of the testing standards indicated in this specification. Substitution of standards will require the prior written approval of the Materials and Research Engineer (MRE) with concurrence of the Geotechnical Engineer-of-Record (GEOR). Provide copies of all substituted standards to the Resident Construction Engineer (RCE) if requested. The RCE will provide the copies to the MRE and GEOR for approval and concurrence. 3.0 MATERIAL 3.1 Geogrid soil reinforcement consists of a regular network of integrally connected polymer tensile elements with aperture geometry (apertures > 0.25 inches) sufficient to permit significant mechanical interlock with the surrounding soil, aggregate, or other material. The structure of the geogrid reinforcements shall be dimensionally stable and able to retain its geometry under construction stresses and have high resistance to damage during construction, to ultraviolet degradation, and to all forms of chemical and biological degradation encountered in the soil being reinforced. Geogrids come in 2 basic configurations, uniaxial and biaxial (includes both biaxial (square and rectangular) and triaxial (triangular)). Geogrid design requirements and placement shall be as shown in the plans and shall meet the properties specified in Section 3.2 or 3.3. 3.2 Provide uniaxial geogrids meeting the following minimum allowable long-term reinforcement tension load, T al in the machine direction as indicated in the table below. Property U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 Allowable Long-term 1, 2 Tension Load, T al (lb/ft) 450 800 1450 2300 3000 3600 4000 6000 9000 13000 1. Minimum T al in machine direction unless otherwise specified 2. Minimum pullout friction factor F*= 0.67*tan ϕ; based on ϕ 28 and C u 4 1

3.3 Provide biaxial geogrids meeting the following minimum allowable long-term reinforcement tension load, T al in the strong and weak axis as indicated in the following table. Property B1 B2 B3 B4 Allowable Long-term Tension Load, T al 1,2 (lb/ft) XMD 1 MD 1 XMD 1 MD 1 XMD 1 MD 1 XMD 1 MD 1 100 65 200 130 400 265 700 465 1. XMD Cross-machine Direction; MD Machine Direction 2. Minimum pullout friction factor F*= 0.67*tan ϕ; based on ϕ 28 and C u 4 4.0 CERTIFICATION 4.1 Prior to construction submit to the GEOR a Certification Package prepared by the geogrid reinforcement manufacturer. Allow 21 calendar days from the day the submittals are received by the GEOR for review and acceptance. State in the Certification Package that the furnished geogrid soil reinforcement is in full compliance with the design requirements as stated in this specification and the design drawings and is fit for use in long-term critical soil reinforcement applications. Certify and document the submittal values for the following items for each geogrid soil reinforcement used on the project: 1. The ultimate tensile strength, T ULT, for geogrid soil reinforcements. 2. The allowable long-term tensile load, T al, for geogrid soil reinforcements 3. The geogrid s pullout coefficients (F*, α) 4.2 Provide the written manufacturer s certification that the material is capable of withstanding direct exposure to sunlight for 500 hours with a minimum strength retained of 70 percent of T ult as measured per ASTM D4355. Include in the submittal package, actual test results for tension, creep, durability, construction damage, joint strength, pullout, quality control and any other tests required by the Department. A person having the legal authority to bond the manufacturer shall attest to the certificate. If in the opinion of the GEOR, the required documentation is not provided for individual reduction factors (RF) or pullout coefficients (F*, α), use default values for these design parameters in accordance with this specification. 4.3 For products currently listed by the National Transportation Product Evaluation Program (NTPEP) Geosynthetic Reinforcement (REGEO) plan, base the submittal package on the posted independent product line evaluation report (see www.ntpep.org). For products that are not currently listed by the NTPEP, include in the submittal package all of the information required in the following Sections. 4.4 Certify in the submittal package the following values and document for each geogrid soil reinforcement used on the project: 4.4.1 Determine the ultimate tensile strength, T ult, from multi-rib tensile test for geogrids (ASTM D6637, Method B). Laboratory test results documenting the ultimate tensile strength, T ult, in the reinforcement direction shall be based on the Minimum Average Roll Values (MARV) for the product. 4.4.2 Compute the allowable tensile load, T al, per unit width of geogrid soil reinforcement for the specific backfill type used as follows: TT aaaa = TT uuuuuu RRRR 2

4.4.3 The total reduction factor, RF, is the combined reduction factor for long-term degradation due to installation damage, creep, and durability. The total reduction factor, RF, is defined as follows: RRRR = RRRR IIII RRRR CCCC RRRR DD 4.4.4 Document the individual reduction factors in accordance with the site conditions, design calculations, and specifications. When sufficient documentation is not provided (i.e. the geogrid is not listed on the NTPEP website) for individual reduction factors, RF ID, RF CR, and RF D, use a reduction factor RF of 7.0. Certify and document the individual reduction factors as follows: 4.4.4.1 Document the reduction factor for installation damage, RF ID, using field and laboratory test results and literature review, as described in ASTM D5818 for the reinforced backfill specified or for more severe soils. Test samples subjected to installation damage for tensile strength and deformation characteristics in accordance with ASTM D6637, Method B. Document the recommended values for reduction factors for installation damage (RF ID ) for various soils. The installation damage reduction factor, RF ID, shall range between 1.1 and 1.7 (1.1 RF ID 1.7), regardless of product specific test results. 4.4.4.2 Document the Creep Reduction Factor (RF CR ) using laboratory test results of creep performance over a range of load levels, for a minimum duration of 10,000 hours based on tension creep test (ASTM D5262). Conduct creep testing on samples of sufficient width to be representative of overall product creep response (fiber creep testing will not be accepted). 4.4.4.3 The creep-limiting strength, T I, is based on extrapolating the 10,000 hours (or longer duration) tension creep tests to a 75-year design life, unless a 100-year design life is specified in the plans. Base the creep extrapolation method on the methods described in FHWA NHI-10-025, Design and Construction of Mechanically Stabilized Earth Walls and Reinforced Soil Slopes Volume II - Appendix "D". Document laboratory test results and extrapolation methodology used. 4.4.4.4 The RF CR is defined as the ratio of the average lot specific ultimate tensile strength, T ULTLOT, to the creep-limiting strength, T I. Determine the average lot specific ultimate tensile strength, T ULTLOT, for the lot of material used for creep testing, T ULTLOT, from multi-rib tensile test, ASTM D6637, Method B. 4.4.4.5 The total reduction factor for durability, RF D, is defined as the combined effects of chemical and biological degradation. Document laboratory test results, extrapolation techniques, and a review of available literature to determine the reduction factor for durability for all material components in accordance with FHWA NHI-09-087, Corrosion/Degradation of Soil Reinforcements for Mechanically Stabilized Earth Walls and Reinforced Soil Slopes. The durability reduction factor, RF D, shall range between 1.1 and 2.0 (1.1 RF D 2.0), regardless of product specific test results and is based on a ph range of 3.0 to 9.0 (3.0 ph 9.0) for the proposed backfill materials. 4.4.5 For granular backfill, determine ph values in accordance with AASHTO T-289. For stone backfill, follow SC-T-143 for producing supernate and analyze the supernate according to ASTM D1293. 4.4.6 Document in the Certification Package the determination of whether the pullout coefficients (F*, α) meet or exceed the required coefficients necessary to obtain the T al provided above. 3

4.4.7 Document the pullout friction factor, F*, and the scale effect correction factor, α, from laboratory pullout tests. Conduct pullout testing for site-specific materials or for materials representative of the reinforced backfill at confining pressures specified by the GEOR. When laboratory tests are used from representative soils, document the representative soils by providing the soil s angle of internal friction, gradation, and coefficient of uniformity (C u = D 60 /D 10 ). Document the recommended pullout coefficients for various soil types. Determine the pullout coefficients using the quick effective stress pullout tests per ASTM D6706 and throughthe-junction creep testing of the geogrid per ASTM D5262. When sufficient documentation is not provided for pullout coefficients, F* and α, and the coefficient of uniformity, C u, is greater or equal to 4 (C u 4) and the internal friction angle of the soil is at least 28 degrees (ϕ 28 ) use F* = 0.67*tan ϕ and α =0.8. If the coefficient of uniformity of the reinforced backfill is less than 4 (C u < 4) or the internal friction angle is less than 28 degrees (ϕ < 28 ), use a laboratory pullout test to determine pullout friction factor, F*, and the default scale effect factor, α. 5.0 MANUFACTURING QUALITY CONTROL 5.1 Provide to the RCE a manufacturing quality control certificate and conformance testing results for all geogrid soil reinforcement delivered to the site. A manufacturing quality control program that includes comprehensive QC testing by on-site GAI-LAP (Geosynthetic Accreditation Institute Laboratory Accreditation Program) accredited laboratory and documentation of this quality control program is to be provided by the geogrid manufacturer to the RCE. Sampling for quality control shall be in accordance with ASTM D4354, Table 1. Geogrid product acceptance shall be based on ASTM D4759. Test geogrid samples in accordance with ASTM D6637, Method B. Laboratory test results documenting the ultimate tensile strength, T ult, in the reinforcement direction shall be based on the minimum average roll values (MARV) for the product. Include in the quality control certificate the roll numbers and identification, sampling procedures, and results of the quality control testing with a description of test methods used. Provide the results of index testing shown in the following table for all geogrid soil reinforcement. 4

Applicable Index Testing 1 Type Property Test Method Criteria Polypropylene (PP) Polyethylene (HPDE) Polyester (PET) All Polymers UV Oxidation UV Oxidation Hydrolysis Hydrolysis % Post Consumer Recycled Material by Weight ASTM D4355 ASTM D4355 Intrinsic Viscosity Method (ASTM D4603 and GRI Test Method GG8) with Correlation or Determine Directly Using Gel Permeation Chromatography GRI GG7 Minimum 70% strength retained after 500 hrs. in weatherometer Minimum 70% strength retained after 500 hrs. in weatherometer Minimum Number Average Molecular Weight of 25,000 Maximum Carboxyl End Group (CEG) Content of 30 Certification of Material Used Maximum 0% 1. Testing to be done on the finished product, except for the polyester products which should have testing done on the based (uncoated) yarns. 6.0 METHOD OF MEASUREMENT 6.1 Measurement of geogrid soil reinforcement is on a square yard basis and will be computed based on the total area of geogrid soil reinforcement shown in the plans, exclusive of the area of geogrids used in any overlaps. Overlaps, any geogrid waste and the testing indicated in this Specification are incidental items. 7.0 BASIS OF PAYMENT 7.1 The quantity of geogrid soil reinforcement shall be paid at the contract unit price for Geogrid Reinforcement. All costs for installing the geogrid soil reinforcement is to be included in the amount bid for the pay items below. Payment will be made under: Item No. Pay Item Pay Unit 2037000 Geogrid Reinforcement (Uniaxial) SY 2037010 Geogrid Reinforcement (Biaxial) SY 5