FIELD EQUIPMENT LENDING LIBRARY

Similar documents
USING DATA LOGGERS TO VERIFY BOILER HOT WATER RESET

ENERGY INVESTIGATION. Energy Investigation Organization

South Carolina Society for Hospital Engineers

EFFESUS SYMPOSIUM ENERGY EFFICIENCY FOR EU HISTORIC DISTRICTS SUSTAINABILITY

DCAS Energy Management. August 15, 2014 Ellen Ryan & Mike Dipple

Bringing a little sunshine into our lives

Thermal Imaging Inspection. Report Commissioned By:

AIR MEASUREMENT INSTRUMENTS TSI-ALNOR 2014 CATALOG

PROJECT TITLE PROJECT NO.: CONTRACT TITLE UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

Implementing Low-Cost Energy Savings Projects & Conducting Energy Audits

Multifunction HVAC and IAQ Meter

Bryant University s Energy Guidelines for Sustainability

Asset Energy Calculator Guidance

Measuring Up. Tools for High Performance Building Performance. RESNET 2008 San Diego, CA February 20, 2008 Bill Spohn. Bill Spohn, testo, inc.

Energy Auditing Home inspections & Weatherization. withthermal Imagers

Universal Translator 3: A free software tool to support your data processing needs

Compact flue gas analyser: testo 300 M-I

Saving Energy on Electric, Lighting and Water Systems

Heat Management in a Potash Mine Ryan Isaac Anderson a, Euler De Souza b

Renewable Energy 2014/15

EfficientHealthcare A Perspective on Energy Efficiency in the Healthcare Sector

Mechanical-Electrical Technology MECHANICAL-ELECTRICAL TECHNOLOGY Sacramento City College Catalog

Measuring the Environment

Matt Gudorf UCI Energy Manager

Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

Renewable Energy

Industrial Services. Minimizing Downtime. Maximizing Performance. LDAR. Leak Detection and Repair (LDAR) Services

Where Does It All Go?

Farm Energy IQ. Farms Today Securing Our Energy Future. Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station

SUMMARY OF SERVICES & INCENTIVES

Energy Audit Checklist

Covering (Month/Year): January/2012 Submitted (date): 06/02/2012. Cotentin, Paris, France. van der Lelijstraat, Delft, the Netherlands

Infrared Inspection Report

Fraunhofer CSE: Applied R&D to Drive Clean Energy Technology Commercialization & Economic Development June 2014

Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE

Intelligent Energy Management Systems for Retail Operations

Calculation of AC System Performance Without Gauges

Do-It-Yourself Energy Audit. Bob Furgeson, PE CEM CBCP GBE CEA Shive-Hattery Architects+Engineering

Compliance to the IgCC. September 29, 2011

FLEXIM. FLUXUS Energy. Precision Ultrasonic Flow and Thermal Energy Meters. Unparalleled measurement of low flow rates.

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Giuseppe Giordano Founder & CEO

Multi-function VAC measuring instrument

Air Conditioning, Heating and. Refrigeration Technology. Refrigeration Technology (A35100) Degree Awarded. Admissions. Contact Information

For building inspections

Thermal performance of a closed wet cooling tower for chilled ceilings: measurement and CFD simulation

Green Star Shopping Centre Design PILOT Energy Calculator Guide

FITOCLIMA WALK-IN STABILITY

Retrofit Standardization

Mount Sinai Main Hospital Energy Conservation and Demand Management Plan

COUNTY OF RIVERSIDE, CALIFORNIA BOARD OF SUPERVISORS POLICY H-4. Policy Subject: Number Page. CONSERVATION OF ENERGY H-4 1 of 7

testo 350 M testo 350 XL

Energy Retrofit Loan Program

ITC Rajputana JAIPUR VISION. Formulate an Energy Vision. ITC Rajputana: Responsible Luxury

Heat & Cooling Meters

Air Cooled Packaged Air Conditioning

Energy Efficiency in Multi-Tenant Office Buildings

Energy Management in Synthetic Fiber Industry Case Study: Alexandria Fiber Co. Dalia M. M. Yacout, Mervat A. Abd El-Kawi and Mohamed.

Zoned Comfort Control

George Bourassa, National Director, Commissioning Services Robert Bucey, Program Manager RETRO-COMMISSIONING

From Sensor to Smart Home

Infrared Inspection Report

LIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

Calibration, Qualification and Preventive Maintenance Services Overview

Established in 2011, Deep Lab Enterprises is the foremost manufacturer, supplier and wholesaler of

ELECTRICAL SYSTEMS. TEST YOURSELF QUESTIONS: Answer Key. CHAPTER 1: Sustainability in Electrical Systems

NEWMOA June 30, Fran Boucher LEED AP, Certified Energy Manager Senior Energy Engineer

Solutions for the Energy Challenge

Power Quality tools. Recorders. Troubleshooters. Loggers. for industrial and commercial applications.

COAD Ohio Weatherization Training Center Course Overview

Save with Business Programs and Services

Telecommunication Spaces

IPM Scopes 6/19/2015. The Growers Tool Box. Don t let pests catch you by surprise. Meters & Devices to Improve Plant Quality

Presentation map. Major Problems Faced in Farming Sector. How M2M can help. A Generic Architecture. Enabling Technologies and Standards

Energy Treasure Hunt ESI Members Meeting. Shaunna Tobin, TE Connectivity Kelli Swain, TE Connectivity

Retro-Commissioning for Existing Facilities

MEP's Letter of Assurance

NATIONAL TECHNICAL UNIVERSITY OF ATHENS School of Electrical and Computer Engineering. Lighting Controls. Lambros T. Doulos.

Identifying Energy Saving Potentials in Buildings by Energy and System Monitoring

July P Wide Format Stacker User Guide

EnergyPro Building Energy Analysis. Single-story School Building

HOBO Plug Load Logger (UX ) Manual

Energy Reduction Strategy Through 2020

CIBSE LOW CARBON CONSULTANTS REGISTER SESSION 10 ENERGY EFFICIENCY IN BUILDINGS. I Prophets energy services

Energy Retrofit Loan Program

1 Descriptions of Function

Imp ementation Case:

RESTORE 1030TM Testing Protocol

Fast-action and userfriendly. exchange by the user on site

Comprehensive Energy Audit For Kongiganak Health Clinic

Power Quality tools. Troubleshooters. Recorders. Loggers. for industrial and commercial applications.

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

AEE Technical Roundtable Measurement and Verification. Alec Stevens, PE April 8, 2014

Power Mate Lite Instructions

Application of Advanced Energy Technologies

COMMERCIAL LOAD ESTIMATING. Load Estimating Level 3: Block and Zone Loads. Technical Development Program

179D Tax Deductions for Architects & Engineers

Energy Efficiency Planning. June 30, 2009

The Energy Professional s Guide to. Data Loggers & Building Performance Mark Stetz, P.E., CMVP Stetz Consulting LLC

Transcription:

Advancing energy-efficient building practices through research, outreach, and training. FIELD EQUIPMENT LENDING LIBRARY www.cunybpl.org

Advancing energy-efficient building practices through research, outreach, and training. BP Lab is excited to announce the establishment of our new Field Equipment Lending Library, funded in large part with the generous support of NYSERDA, the NYC DCAS Energy Management Division and the NYC Department of Education s Division of School Facilities. In line with our mission, this new resource is available to industry professionals, current students and alumni of our energy management courses, and workforce development organizations to help advance high-performance building operations and practices in the existing commercial and public real estate markets. The new library is stocked with a full range of field equipment that can be used to test, measure and diagnose building system operations and facilitate ongoing commissioning, building retuning and retrofit projects. Available Lending Library equipment includes HOBO data loggers, CO2 meters, contact and infrared thermometers, ultrasonic non-intrusive flow meters, bolometers and Chroma meters. In addition, we have a variety of simulation and diagnostic software that can be used onsite at BP Lab. www.cunybpl.org

Advancing energy-efficient building practices through research, outreach, and training. Table of Contents Thermal Image Cameras Data Loggers Current Sensors Light Meters Hot Wire Anemometer www.cunybpl.org

Thermal Image Camera Model: Fluke - Tis Model: Flir i7

Thermal Image Camera Great tool for: Building inspector, electrician, energy auditor, window installer. It can be used to find: Moisture intrusion, detect energy loss/missing insulation, and many basic electrical connection and load problems. www.cunybpl.org

THERMAL IMAGE CAMERAS: USES AND PROBLEMS THAT CAN BE IDENTIFIED

Overheated Motor Electrical Panel

Wet Insulation Clear Referencing of Air Leaks

Single Phase Transformer Three Wire Problem

Data Loggers Motor on/off Data Logger Model: UX90-004 Light on/off Data Logger Model: UX90-002

Motor on/off Data Logger - UX90-004

Motor on/off Data Logger - UX90-004 The UX90-004 standalone data logger monitors: A motor s on and off conditions, Giving a record of when a motor is on, when it is off, and its run time. It can be used to verify motor conditions, such as: Ensuring that they re off at night, Reveal problems with control logic, like having hot and chilled water pumps running simultaneously. www.cunybpl.org

Motor on/off Data Logger - UX90-004 Motor on/off Data logger Placement The magnets in the back of the logger allows for a easy attachment and placement on motors Other options are Velcro and sticky stickers

Motor on/off Data Logger - UX90-004 Quick Live Demonstration

Light on/off Data Logger - UX90-002

Light on/off Data Logger - UX90-002 The UX90-002 standalone data logger monitors Indoor light changes with an internal sensor, Records light on and off conditions. It s ideal for: building energy audits light usage analysis. www.cunybpl.org

Light on/off Data Logger - UX90-002

Light on/off Data Logger - UX90-002 Quick Live Demonstration

Data Loggers Temperature and Relative Humidity Data Logger Model: U10-003 4 External Channel Data Logger Model: U12-006 Temp/RH/Light/External Data Logger Model: U12-012 Temp/RH/2External Data Logger Model: ZW-005 15 Channel Smart Sensor Cellular Data Logger Model: U30-GSM

Data Loggers Temperature and Relative Humidity Data Logger Model: U10-003 4 External Channel Data Logger Model: U12-006 Temp/RH/Light/External Data Logger Model: U12-012

U10-003 U12-006 U12-012 The U10-003 standalone data logger Records Temperature and Relative humidity with an internal sensor The U12-006 standalone data logger Uses its input jacks for External sensors to record and store data within the logger Can log 4 different External sensors at the same time The U12-012 standalone data logger Records Temperature/RH/Light with an internal sensor Uses the input jack for an External sensor connection www.cunybpl.org

Data Loggers Temp/RH/2External Data Logger Model: ZW-005 15 Channel Smart Sensor Cellular Data Logger Model: U30-GSM

ZW-005 Temp/RH/2External The ZW-005 is a Wireless data logger Records Temperature and Relative Humidity with an internal sensor It s 2 External jacks allows it to connect to external sensors compatible with the logger for recording and storing data Note: This logger requires a ZW-Receiver and ZW-Router logger to communicate the data back to the PC www.cunybpl.org

ZW-005 Temp/RH/2External www.cunybpl.org

ZW-005 Temp/RH/2External www.cunybpl.org

U30-GSM 15Ch. Cellular Data The U30-GSM is a web-based monitoring system It s 15 Channel smart sensor plug-in allows it to be a data logging system for a broad range of energy and weather monitoring applications. www.cunybpl.org

U30-GSM 15Ch. Cellular Data Energy Data Collection Weather Station www.cunybpl.org

Current Sensors CTV-A 0-20 AMP Split Core CTV-B 0-50 AMP Split Core CTV-E 0-600 Amp Split Core

Current Sensors These devices are mounted around a current-carrying wire to measure AMPERAGE. Used to access the power usage of various types of equipment including variable frequency drives and switched power sources For use with U12 series and ZW series data logger with external input channels to store the data www.cunybpl.org

Current Sensors U12-006 External Logger box CTV-B 0-50 Amps Fan wire Fan www.cunybpl.org

Light on/off Data Logger - UX90-002 Quick Live Demonstration

Light Meters Digital Light Meter Model: LM-100

Light Meters Is a handheld device that measures: illumination in footcandles (lm/ft2) or lux from fluorescent, metal halide, high-pressure sodium or incandescent sources. Is the standard unit used in the lighting industry. Used in different building types: (retail stores, office spaces, schools, hospitals, and homes) specific areas within buildings (rooms, hallways, and stairs) vary in their recommended lighting levels. www.cunybpl.org

Light Meters

Light Meters

Hot Wire Anemometer Model: AVM430

Hot Wire Anemometer A handheld device that measures: air velocity flow temperature. It s ideal applications include: HVAC system performance Commissioning plant maintenance critical environment certification duct traverses. www.cunybpl.org

Hot Wire Anemometer

Hot Wire Anemometer Quick Live Demonstration

Advancing energy-efficient building practices through research, outreach, and training. How to Borrow from the Field Equipment Lending Library Head to the BPL website: http://www.cunybpl.org On the Resources tab at the top of the website, locate the Field Equipment Lending Library link Confirm that the equipment you would like to borrow is within our inventory list Email to set-up a reservation for the equipment www.cunybpl.org

Advancing energy-efficient building practices through research, outreach, and training. Contact information Website: http://www.cunybpl.org Honey Berk, Technology Specialist Felix Rodriguez, Equipment Specialist Building Performance Lab CUNY Institute for Urban Systems CUNYlends@cunybpl.org www.cunybpl.org