Passive Sampling Demonstration/Validation for Vapor Intrusion Assessments

Similar documents
Quantitative Passive Diffusion-Adsorptive Sampling Techniques for Vapor Intrusion Assessment

Passive Sampling for Vapor Intrusion Assessment

Mass Flux Characterization for Vapor Intrusion Assessment

ESTCP Research on Optimization of Vapor Intrusion Mitigation Systems in Large Military Buildings

New Developments in Thermal Desorption (TD) Tube & Canister Technologies for Collection & Analysis of Soil Gas

Empirical Data: Challenges and Future Directions

Increasing Availability of Continuous and Real-Time VOC Monitoring Technologies for VI Assessment

Evaluation of Spatial and Temporal Variability in VOC Concentrations at Vapor Intrusion Investigation Sites.

How the Navy Leverages GIS to Detect and Remediate Vapor Intrusion

Available Laboratory Methods for Soil Gas Analysis

The Role of Vapor Intrusion and the Challenges of Reporting Representative and Relevant Data

Sub-Slab Sampling and Analysis to Support Assessment of Vapor Intrusion at the Raymark Superfund Site

Abstract. Thomas R. Eschner and David Dinsmore, Woodard & Curran.

Charles Sarnoski Delaware Department of Natural Resources & Environmental Control Division of Air Quality

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Use of Building Pressure Cycling in Vapor Intrusion Assessment

MEMORANDUM. To: Billy Meyer. Christie Zawtocki, PE Timothy Klotz. Date: April 8, 2014

Examples of Data Collection Strategies and Methods

PASSIVE GROUNDWATER SAMPLING METHODS. Applications and Experience

Determining the Influence of Background Sources on Indoor Air Concentrations in Vapor Intrusion Assessment

Lessons from Petroleum Hydrocarbon and Chlorinated Solvent Sites Extensively Monitored for Vapor Intrusion

Is this the maturation Phase of Vapor Intrusion Investigations?

Passive Gas Environmental Site Assessment and Monitoring

PILOT PROJECT «ILE DE FRANCE»

ABSTRACT: Principal Contact: Chris Lutes, ARCADIS, 4915 Prospectus Dr. Durham NC, 27713, , (fax),

Use of Crawl Space Sampling Data and Other Lines of Evidence for Evaluating Vapor Intrusion

COST-EFFECTIVE SAMPLING of GROUNDWATER MONITORING WELLS: A Data Review & Well Frequency Evaluation. Maureen Ridley (1) and Don MacQueen (2)

Update - Vapor Intrusion and Mitigation in Florida

FINAL INDOOR AIR QUALITY INVESTIGATION BUILDINGS A, B, C, AND VLS LOCKHEED MARTIN MIDDLE RIVER COMPLEX

Steps in Conducting Structural Vapor Intrusion Potential Evaluations Under the Inactive Hazardous Sites Branch 13 February 2017

Indoor Air Quality Testing at the Middle River Complex. Indoor Air Quality Testing at the Middle River Complex. For More Information

radiello Air Sampler Diffusive Sampling System Klaus Buckendahl Sigma-Aldrich Chemie GmbH

Soil Vapor Reproducibility: An Analytical and Sampling Perspective

UNDERSTANDING THE ROLE OF SEWER PREFERENTIAL PATHWAYS IN VAPOR INTRUSION. Thomas McHugh, Ph.D., D.A.B.T. Lila Beckley, P.G.

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis

TECHNICAL MEMORANDUM

Case Study of Modeled and Observed TCE Attenuation from Groundwater to Indoor Air. Christopher G. Lawless Johnson Wright, Inc.

PVI Risk Pathway: Sampling Considerations

New Data on Attenuation Coefficients for Crawl Spaces and Deep Soil Gas from the Lowry AFB Site, Denver, Colorado

TREATMENT OF PERCHLORATE AND 1,1,1-TRICHLOROETHANE IN GROUNDWATER USING EDIBLE OIL SUBSTRATE (EOS )

Collection of Samples for Analysis of Volatile Organic Compounds (VOCs) in Indoor Air Using Sorbent Tubes. BAA Guide October 1, 2007

Solutions for monitoring VOCs in air

Vapor Intrusion Assessment A Comparative Analysis of Subsurface Vapor Sampling Methods

INDOOR AIR INVESTIGATION

Field Investigation of Vapor-Phase-Based Groundwater Monitoring

Soil Gas Sampling for Vapor Intrusion Assessments: Key Issues

U.S. EPA s Vapor Intrusion Database: Preliminary Evaluation of Attenuation Factors

Soil vapor surveys can be used for a number of purposes, including the following:

Comparison of purge and no-purge sampling strategies for deep groundwater

Volatile Organic Compounds in Solids PBM

Refinery Benzene Fenceline Monitoring: Considerations in Addition to Cost

Emission Testing August 2013 EPA 4 Benzene Combustor Inlet/Outlet Testing

Soil Gas Analytical Methods (Overview, TAGA, Forensics)

Area B Groundwater Investigation Fort Detrick

Research Report. Determination of Formaldehyde Using The SKC UMEx 100 (Cat. No ) Diffusive Sampler. Abstract

Volatile Organic Compounds (VOCs) In Indoor Air: Emission From Consumer Products and the Use of Plants for Air Sampling

PASSIVE SOIL GAS TESTING: STANDARD FOR SITE CHARACTERIZATION

Executive Summary. 2. Property Investigations Groundwater Sampling Soil Sampling Soil Vapor Sampling 5

International Journal of Soil, Sediment and Water

Installation of Liquid Boot a spray applied membrane to reduce vapor intrusion of chlorinated solvents and radon

NEWMOA/ Brown SRP Vapor Intrusion Workshop. September 26 and 26, η T. q = k ρ g. D ig. = d i air η g. dφ = gz + 10 / 3

Catalyzed Persulfate Remediation of Chlorinated and Recalcitrant Compounds in Soil

Vapor Intrusion Attenuation Factors Based On Long Term Monitoring Data

Understanding VI Screening Levels

Atlantic RBCA Guidance for Soil Vapour and Indoor Air Monitoring Assessments: Overview. December 7 th, 2006 Moncton, New Brunswick

Validation of Nitrous Oxide Using SKC Passive Sampler SKC Inc. 863 Valley View Road Eighty Four, PA 15330

Benzene, toluene and xylene measurements in the vicinity of petrol stations (Toulouse France)

Presenter Bios. Finding Practical Solutions for the Chlorinated Vapor Intrusion Pathway: Helping RCRA Facilities Meet Significant Challenges

6.1.2 Contaminant Trends

Best Practices for Collecting Soil Samples for VOC Analysis

Quantitative Decision Framework for Vapor Intrusion Evaluation in DoD Industrial Buildings - Based on an Empirical Database

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

ROUX ASSOCIATES, INC. Environmental Consulting & Management

Rigid Porous Polyethylene Passive Diffusion Samplers

VAPOUR INTRUSION SPECIAL ISSUE. OUT WITH THE OLD A new way of measuring soil vapour. SOIL VAPOUR INTRUSION IN HOMES Case study

Collegeville Area Air Monitoring Project Second Report. March 7, Commonwealth of Pennsylvania Department of Environmental Protection

WBEA Standard Operating Procedure

Soil Vapor Migration Through Subsurface Utilities

Since I wrote Part 3 of this Collecting Reliable Soil-Gas Data series in LUSTLine #48, Nov 2004, the subject of vapor intrusion

MISSOURI RISK-BASED CORRECTIVE ACTION (MRBCA) FOR PETROLEUM STORAGE TANKS SOIL GAS SAMPLING PROTOCOL

Low-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator

Comparison of Three Numerical Models for Chain-Decay Transport Simulation at a Closed AFB in Texas

Sustainability; in Residential, Commercial and Industrial Buildings

Soil Vapor Installation

Why are you making the measurement? Methods for measuring plant uptake of chemicals: lab and field. General considerations. What are you measuring?

DEPARTMENT OF THE AIR FORCE PACIFIC AIR FORCES

H&H Job No. DS0-05. April 29, South Tryon Street Suite 100 Charlotte, NC

Case Studies of Innovative Use of Tracers, Indicators and Field GC/MS for Assessing the Vapor Intrusion Pathway

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Characterizing TCE Exposure Distribution for Occupants of Houses with Basements

VAPOR INTRUSION FROM REGULATORY, TECHNICAL,

Health Consultation. Lakeland Groundwater Contamination Plume. City of Lakeland, Washington County, Minnesota. MPCA Site Response Number SR145

VOC TEST REPORT French VOC Regulation

Mobile Water Treatment Trailer

Slide 1. Welcome to our Webinar: An Intro to the new Low Level MIP. we will begin shortly

Proposed Changes to EPA s Spreadsheet Version of Johnson & Ettinger Model (and some new spreadsheet tools)

Phytoremediation Technology Evaluation and Preliminary Design

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Technology Overview KLOZUR PERSULFATE

SECTION 2 WATER 2.1 ROUTINE WATER COLUMN MONITORING Collection Summary

Transcription:

Passive Sampling Demonstration/Validation for Vapor Intrusion Assessments Todd McAlary and H. Groenevelt, Geosyntec Consultants, Inc., T. Gorecki and S. Seethapathy, University of Waterloo, D. Crump, Cranfield University, P. Sacco, Fondazione Salvatore Maugeri, H. Hayes, Air Toxics Limited, M. Tuday, Columbia Analytical Services, B. Schumacher, USEPA, P. Johnson, Arizona State University NEMC Chicago 16 July 2015

Benefits of Passive Sampling Simple (minimal training, less risk of leaks) Time-weighted average concentration (up to a week or a month if needed) Low reporting limits with no premium cost Smaller easy to ship, discrete to deploy Long history of use in Industrial Hygiene Less expensive Other benefits unique to each sampler 2

Passive Samplers Tested ATD Tubes SKC Ultra II ATD Tubes 3M OVM 3500 The mass (M) and time (t) are measured accurately. Key is to know the uptake rate (UR) C 0 = Equivalent Sample Volume M UR t Waterloo Membrane Sampler Radiello Differences: size, uptake rates, sorbents, medium of uptake, method of analysis 3

TO-17 Sorbent Selection

Laboratory Test Compound List Analyte Koc (ml/g) OSWER indoor conc. at 10-6 risk (ppb) Vapor pressure (atm) Water solubility (g/l) 1,1,1-Trichloroethane 110 400 0.16 1.33 1,2,4-Trimethylbenzene 472 1.2 0.00197 0.0708 1,2-Dichloroethane 174 0.023 0.107 8.52 2-Butanone (MEK) 134 340 0.1026 ~ 256 Benzene 59 0.10 0.125 1.75 Carbon tetrachloride 174 0.026 0.148 0.793 Naphthalene 2,000 0.57 0.000117 0.031 n-hexane 3,000 57 0.197 0.0128 Tetrachloroethene 155 0.12 0.0242 0.2 Trichloroethene 166 0.22 0.0948 1.1 5

Passive Sampler Calibration Testing included: 5 samplers in triplicate 10 Compounds High, Medium and Low: Concentration, Face Velocity, Temperature, Relative Humidity, Duration 24 chambers x 5 sampler types x 3 replicates x 10 chemicals = 3600 data points 6

7

Inter-laboratory Test (blank contamination) +2X Target Range -2X MEK 8

Fractional Factorial Testing 9

Center-Point Results +45% +25% -25% -45% Results only for the center-point tests (all factors at middle of ranges) (note scales are linear)

ATD Tenax TA 95% of results within a factor of 2 of Active Samples Except hexane (slight low bias)? (note scale is logarithmic) 11

ATD Carbopack B 98% of results within a factor of 2 of Active Samples, except MEK and 1,2-DCA (low bias high polarity)? (note scale is logarithmic) 12

SKC Ultra Many samples with low bias up to 100X Low concentration & low velocity runs especially (note scale is logarithmic) 13

Waterloo Membrane Sampler 95% of results within a factor of 2 of Active Samples, except 124TMB and naphthalene (low bias)??? Starvation (note scale is logarithmic) 14

Radiello 94% of results within a factor of 2 of Active Samples, except MEK (low bias) and naphthalene (high bias)? (note scale is logarithmic) 15

Inter-Chamber Precision 16

Intra-Chamber Precision 17

Accuracy 18

High Concentration Lab Tests (To mimic soil gas conditions) 19

High Concentration Lab Tests 20

High Concentrations Test Results Normalized Concentrations (10 ppm Test) 1.8 C/Co 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 +25% -25% WMS ATD Radiello 3M OVM SKC Sampler Type MEK n-hexane 12DCA 111TCA Benzene CT TCE PCE 124TMB +/- 25% 21

Field Testing Indoor and Outdoor Air Sub-slab Soil Gas Acknowledgements to Ignacio Rivera and Bart Chadwick of SPAWAR for Support 22

Indoor Air VOCs at Cherry Point 100# Passive%Sampler%vs.%Summa%Canister%for%Indoor%Air % 10# Passive%Sampler%Concentra/on%(µg/ m 3 ) % 1# 0.1# Blank contamination R²#=#0.93704# R²#=#0.97432# R²#=#0.86277# R²#=#0.78629# R²#=#0.94646# WMS# 3M#OVM# ATD# RAD# SKC# Linear#(WMS)# Linear#(3M#OVM)# Linear#(ATD)# Linear#(RAD)# Linear#(SKC)# Linear#(1:1)# Linear#(+#50%)# Linear#(E#50%)# Linear#(+2x)# Linear#(E2x)# 0.01# 0.01# 0.1# 1# 10# 100# Summa%Canister%Concentra/on%(µg/m 3 )% % Excludes compounds for which equivalent sample volume was greater than Safe Sample Volume 23

Sub-Slab Navy San Diego Sub-slab samples only Fully-passive and with PID purging (flow-through) Starvation proportional to uptake rate Less starvation for semi-passive samples 24

Soil Gas @ 12 ft Hill AFB 6 probes -12 ft deep Latin Square Design 1 to 12 day exposures Co Measured using combination of Summa and Hapsite GC/MS Negative bias for long duration with ATD-Tenax Negative bias for high uptake rate (Radiello) Otherwise, encouraging results for TCE and DCE 25

Mathematical Modeling 26

Transient and Steady-State Modeling 27

Modified Uptake Rates Lower uptake rate = less starvation SKC Ultra II and 12-hole Cap ATD Tube & Pinhole Cap WMS and Low-Uptake WMS 28

Soil Vapor Sampling NAS JAX Probes to 3-4 feet deep, exposure durations of 20, 40 and 60 minutes Strong correlations, regression slopes all near 1.0 29

Passive Sub-Slab NAS JAX Limited to 1-inch diameter or less Low-Uptake Rate Samplers 30

Starvation and Retention Two important considerations 1) Starvation = f (uptake rate) 2) Equivalent Sample Volume (UR x t) vs void volume (V V) 31

Overall Correlation between Passive and Active Samplers Strong correlation to conventional samples over 6+ orders of magnitude Quantitative results for soil vapor (a breakthrough) 32

Performance Assessment Accuracy Met criterion in most cases, except: (UR x t) > Safe Sample Volume (poor retention) UR > Diffusive Delivery Rate and (UR x t) > Void Volume (starvation) Blank contamination (rare) Some compounds posed challenges for some conditions Precision E.g., MEK on charcoal with high humidity Excellent within replicates (often better than TO-15 or TO-17) More sensitive to conditions during sampling Ease of use Cost Comparable or better than TO-15 and TO-17 Savings increase with size of the sampling program 33

Reports and Articles ESTCP Report Navy Report Soil Vapor - #1 Soil Vapor - #2 Soil Vapor - #3 Soil Vapor - #4 U.S. Pat Pending U.S. Pat Pending Lab Chambers Eng. Issue Paper Quantitative Passive Soil Vapor Sampling Method for Deployment of Passive Soil Vapor Samples Plus ~30 conference presentations

Take-Home Messages Passive Sampling is a valid option for many VOCs Integrate over time to manage temporal variability for indoor air Simpler protocols for soil gas sampling less operator error Easier to ship, handle and deploy lower overall cost Precision and accuracy mostly comparable to active samplers Five Potential Biases Retention, starvation, calibration, contamination, recovery All avoidable through careful sampler/sorbent selection, QA/QC Benchmarking is recommended for highest confidence 1 of 10 samples collected with a duplicate active sample Accounts for site-specific conditions, challenging compounds 35

Acknowledgments Funding gratefully acknowledged from: ESTCP ER0830 U.S. Navy Environmental Sustainability Development to Integration (NESDI) Program In-kind contributions from Geosyntec Consultants, Inc. 36