Home Stretch Liquid Waterproofing Fluid Applied Waterproofing Membrane

Similar documents
Blue Barrier Flash N Wrap 2400

THE BRITE THING TO DO

Blue Barrier Liquid Wrap 2300

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Data Sheet Eco-Smart Membrane WS M1

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

BEP Blue Barrier Installation and Application Guide

TECHNICAL DATA SHEET

SPF Roof System Section Coated Foam Roofing

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION VAPOR IMPERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

AVM System 500. Aussie Membrane 500

FireShield Restoration Specifications - EPDM

TERM Foundation Barrier

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

Specifications. Specifications (Architectual) Metallic System. Metallic System

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

BEP Blue Barrier Installation and Application Guide

POLYURETHANE FOAM SAMPLE DESIGN GUIDELINES URETHANE

Acrylitex Interior Texture and Coating Submittal Documentation

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Date Of Issue : February 2000 Page 1 of 5 Ref tec005 TECHNICAL DATA SHEET

Refer to Substrates & Surface Preparation.

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TL-250 Glass Flake Filled, Vinyl Ester Tank Lining System

Section COATING RESTORATION

SECTION CONCRETE AND MASONRY COATINGS

Acry-Tek 4200 / SPF Recoat System

Instruction Guide APPLICATION OF CIM TO CONCRETE

A. The work of this section includes, but is not limited to, the following:

TECHNICAL DATA SHEET

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

TECHNICAL DATA SHEET

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

Pacific Polymers Elasto-Deck BT Guide Specification

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

TOPCOAT System Specifications Corrugated Transite Panels

D. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for waterproofing.

FEATURES AND BENEFITS

Henry Blueskin VP160 Air Barrier System Installation Manual

PRODUCT DATA SHEET SARNACOL 2121

CIM IG 13 11/06. Instruction Guide

REV:6-30/09/30. Liquid Rubber Timber Specification

Finestop RS Vapor Permeable Air/Water-Resistive Barrier Membrane. Product Bulletin

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

TECHNICAL DATA SHEET

the SureCoat Roof System.

Application Specification:

Air and Vapor Barrier 3015

SECTION EPOXY FLOORING SYSTEMS

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

ITEM 458 WATERPROOFING FOR STRUCTURES

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

CP-24CC Potassium Silicate Concrete

APPLICATION GUIDELINES RAPID REPAIR EXTERIOR DECK SYSTEM

VB (Vapor Barrier) R Guard

For detailed product information, visit our DeckOver, Textured DeckOver or Extra Textured Deckover product pages.

PermaroofUK. Frequently asked questions

SECTION EPDM MEMBRANE WATERPROOFING

TOPCOAT Restoration Specifications Structural Concrete

UNIFIED FACILITIES GUIDE SPECIFICATIONS

BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

International Fireproof Technology Inc.

Product Information. DiamondCoat Polyurethane Concrete Floor Finish Clear, high build, high abrasion resistant, decorative concrete floor coating

DOWSIL ALLGUARD Silicone Elastomeric Coating

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

GE SCM3500 High Solids Silicone Roof Coating

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

WATERPROOFING TAMKOWATERPROOFING.COM

Installation Instructions. Important. Recommended Tools. Palladium Rigid Sheet/Rubrail or Palladium G2 Sheet/Rubrail. Storage

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

A Design Review of Waterproofing Codes

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials

SECTION SELF-ADHERING SHEET WATERPROOFING

Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF

APPLICATION GUIDELINES EXTERIOR DECK SYSTEM

CC-1004 Ultra High Temperature Epoxy Adhesive

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

BTM BT2K 600. Areas of Use

Refer to Substrates & Surface Preparation.

Measured in accordance with ASTM D 2697.

Detail Set: Thermax Wall System Masonry

A. Submit product data sheets and literature verifying physical properties of materials.

Transcription:

STEP 1 Apply the Poly Wall Home Stretch Liquid waterproofing system onto vertical cast-in-place concrete, concrete masonry (CMU), or precast foundation walls. The substrate foundation wall must be clean; dry; clear of dirt, debris, frost, smears, and concrete form release agents; and be allowed to cure a minimum three (3) days prior to the application of the Home Stretch Liquid waterproofing system. Do not use the Home Stretch Liquid waterproofing system on Insulated Concrete Form (ICF) walls, which utilizes rigid plastic foam insulation. The Home Stretch Liquid membrane contains solvents which will attack the rigid foam insulation. For ICF walls, Poly Wall recommends our Home Stretch Membrane ICF sheet waterproofing system. Take safety precautions and wear appropriate safety gear for the application of solvent-based coatings (i.e. gloves, eye protection, ventilation, etc.). Prohibit flames, sparks, welding, or smoking around the Home Stretch Liquid membrane and during its application.

STEP 2 Minor voids in the foundation wall, as well as wall control joints, are to be filled and sealed with Poly Wall Blue Barrier 2200 Joint Filler. Application of the Blue Barrier 2200 can be executed either before or after the application of the Poly Wall Home Stretch Liquid waterproofing membrane. Allow the Blue Barrier 2200 Joint Filler a minimum one (1) hour to skin over before covering with the Home Stretch Liquid, adding additional time for lower ambient and surface temperatures. A primer is not required to install Home Stretch Liquid onto cast-in-place concrete or concrete masonry (CMU) foundation walls. Install the membrane directly over clean and dry foundation walls in ambient and surface temperatures between 0 (F) and 120 (F).

STEP 3 Apply Home Stretch Liquid evenly to the foundation wall in one or more coats using airless spray equipment, brush, or roller, to achieve a continuous film at the desired coverage rate of 27 square feet per gallon (60 mils wet in total). Home Stretch Liquid dries to a total average thickness of 30 mils. Coverage rates will vary inversely related to the concrete substrate texture and porosity.

STEP 4 For applications with an airless sprayer, use 3700 to 4000 PSI stall pressure and a 0.037-inch reversible tip. Allow the Home Stretch Liquid application to dry for a minimum twenty-four (24) hours, and then inspect for complete and continuous coverage. During the inspection, apply additional Home Stretch Liquid material as needed to provide a complete and continuous membrane, then allow an additional minimum twenty-four (24) hours for the additional material to dry before continuing work on the foundation wall surface. Drying in direct sunlight and temperatures above 65 F (18 C) can cause blistering of Home Stretch Liquid. Where said exposure can t be avoided, apply the waterproofing membrane in multiple coats of 20 to 30 mils wet, allowing each application layer to dry a minimum twenty-four (24) hours before applying the next layer. Apply Home Stretch Liquid from the bottom of the foundation wall to align with grade. When continuing the Home Stretch Liquid above grade level is required to reach the top of foundation, apply Poly Wall Aluma Flash PLUS or metal flashing over all of the Home Stretch Liquid above grade, with its lower edge a minimum of four (4) inches below grade, to protect the installed Home Stretch Liquid from UV exposure beyond its 30 day limit.

STEP 5A Apply a 3/4-inch, tooled bead of Poly Wall Blue Barrier 2200 Joint Filler at the intersection of the vertical foundation wall and the horizontal footer face prior to the Home Stretch Liquid application.

STEP 5B If Home Stretch Liquid is continued at the base of the foundation wall onto the footer, apply a 3/4-inch, tooled bead of Poly Wall Blue Barrier 2200 Joint Filler at the intersection of the vertical foundation wall and the horizontal footer face prior to the Home Stretch Liquid application.

STEP 6 Install Poly Wall s Arroyo brand of Protection and Drainage Board accessory products over the complete and continuous Home Stretch Liquid waterproofing system; or provide another protective board by others, and then backfill in a non-destructive manner. After application, the Home Stretch Liquid waterproofing membrane is not affected by immediate or subsequent exposure to rainy weather. Home Stretch Liquid will be adversely affected by prolonged or constant ultraviolet radiation (UV) exposure longer than 30 days. For periods of (UV) exposure greater than 30 days, remove and recoat uncovered/exposed Home Stretch Liquid. REV02/14/17