EDUCATION EXPERIMENT. Fluorescence of an Unknown Fluorophore. Introduction.

Similar documents
The New Wave in Spectroscopy FS-2 FluoroMate Fluorescence Spectrometer

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

SpectraMax Multi-Mode Microplate Readers

Cleaning Validation PRODUCT OVERVIEW

Short Term Tender Notice

DeltaPro. DeltaFlex FORENSICS PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

FRET Sensitized Emission

Experiment B-38 Monitoring Yeast Growth

Thermo Scientific GENESYS 10S Bio spectrophotometer

Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting

Sub-micron scale patterning of fluorescent. silver nanoclusters using low-power laser

Skoog, Holler and Nieman, Principles of Instrumental Analysis, 5th edition, Saunders College Publishing, Fort Worth, TX 1998, Ch 33.

d. Bands hidden by overexposure with chemiluminescence become clear when imaged with Odyssey.

Spectral Separation of Multifluorescence Labels with the LSM 510 META

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

MyiQ Single-Color Real-Time PCR Detection System

Fuel Leak Simulation

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron with 1,10-Phenanthroline

icycler iq Real-Time PCR Detection System Instruction Manual

ICP Expert software. Technical Overview. Introduction

ABSTRACT INTRODUCTION

Flow Cytometry - The Essentials

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Confocal Microscopy Analyzes Cells

Attune TM Acoustic Focusing Cytometer Training. Manik Punj Attune Training

Camera Eyepiece. User s Manual. KS035200G4-Ver1.0

Size quality report for the Zetasizer Nano

Biochemical Analysis The Lambda Series UV/Vis Spectroscopy

UV-Visible Spectrophotometer Calibration. S.ZALI M.Sc. Dept. of Analytical chemistry Razi vaccine serum research institute

Fig1: Melt pool size of LAMP vs. µlamp. The LAMP process s melt pool is x the area of the LAMP s melt pool.

Evaluation Report of

Quick Manual to the Waters UPLC System

Innovations To Meet Your Needs

AccuSEQ Real-Time PCR Detection Software

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Before You Begin. Calibration Protocols

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

Mini Scanner New Purchase Order... 3

Scanning Devices Label Counting Table Operations Manual

Miniaturised SAC Measurement for Continuous Monitoring of Water Quality

Spectroscopy Fiber Optic Probes for In-line Analytical Analysis

User Manual QProg Lite

CHM 317H1S Winter 2018 Section D - Molecular Fluorescence

Bioinstrumentation Light Sources Lasers or LEDs?

VIS / UV-VIS Spectrophotometer XD 7000 / 7500

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

solutions UV-visible spectroscopy for chemical analysis Agilent 8453 UV-visible spectrophotometer Our measure is your success.

Raman. UV NIR Spectrometers. Embedded Spectroscopy. Electronics. Software. Customization. Diode Array Technology. High Speed and Dynamics

Thermo Scientific Evolution Array UV-Visible Spectrophotometer

Agilent Cary 8454 UV-Visible Spectroscopy System. Installation Guide

Chem 2115 Experiment #9. Consumer Chemistry: Determining the Iron Content in Supplements

July 27, A NEW EPA APPROVED METHOD FOR TURBIDITY ANALYSIS 360 x 90, Turbidity Method TURBIDITY MEASUREMENT HISTORY

Optical Coatings. Photonics 4 Luxury Coatings , Genève. Dr. Andreas Bächli Head of Optical Coatings at RhySearch, Buchs (SG)

Spectroscopy Solutions for Pharmaceuticals:

Thermo Scientific Antaris II FT-NIR Analyzers

Service Plan Creator. Quick Reference Guide RapidFire Tools, Inc. All rights reserved. V Ver 1I

Advantages of Photodiode Array

Qswitched lasers are gaining more interest because of their ability for various applications in remote sensing, environmental monitoring, micro

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Nanophotonics: principle and application. Khai Q. Le Lecture 11 Optical biosensors

Flexible. Accurate. Intuitive. AGILENT CARY 100/300 SERIES UV-VIS SPECTRoPHOTOMETERS

Thermo Scientific Evolution Array UV-Visible Spectrophotometer

Smaart v8.2 Release Overview

SpectraMax Paradigm Fluorescence Polarization (FP) Detection Cartridge User Guide

HOMOSIL, HERASIL 1, 2 and 3

PowerPlex Matrix Standards, 3100/3130

Winzer Corporation 1 Revision: 4.0

SoftMax Pro 5 Software

Transmission Mode Photocathodes Covering the Spectral Range

Opti-Check Handheld Fluorometer

TurboMass GC/MS Software

XDS TM Multipurpose NIR-analyser for Laboratories

User s Manual. Chart Projector GCP-7000

UV-visible spectroscopy solutions for chemical analysis

iq 5 Calibration: Contents.

Bacterial Counts - Quantitative Analysis of Microbes

DCMS Link 2.10 for Compass / HyStar

Microscopy from Carl Zeiss. DirectFRAP. News from the Cell. The New Class of Laser Manipulation for the Analysis of Cell Dynamics

D A T A L O G G I N G

NEW. NIST Traceable UV/Vis/NIR Reference Sets USP 857

Real-time tablet API analysis: a comparison of a palm-size NIR spectrometer to HPLC method

Electra Elite IPK II In-Mail Utility Guide

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

Application Note Vibration Criteria for Facilities with Sensitive Equipment. Vibration Measurement

average diameter = 3 nm, from PlasmaChem) was mixed in NLCs to produce QDembedded

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

User s Manual HANDHELD DUROMETER DI RECT DI GI TAL READOUT HL-1300

Fujitsu RFID Integrated Label Solution. First Step Guide. November 2015 Version 1.21 A698HL EN

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

Near Infrared and Raman Spectroscopy for in-line Monitoring of Polymers - Applications in the Polymer Industry

APPLIED. OiW-100 Oil in Water Analyzer

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Fluorescence Microscopy. Terms and concepts to know: 10/11/2011. Visible spectrum (of light) and energy

Confocal Microscopes. Evolution of Imaging

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

TECHNICAL NOTE THE NEXT GENERATION OF MICROPLATES

Layer Thickness Analysis of Thin Metal Coatings with. Bruker Nano Analytics, Berlin, Germany Webinar, June 8 th 2017

GammaVision 7. High Resolution Gamma Spectroscopy Software

If you want to flag a question for later review, select the "Mark for review" button.

Transcription:

EDUCATION EXPERIMENT Fluorescence of an Unknown Fluorophore Introduction www.oceanoptics.com info@oceanoptics.com Fluorescent tags have become a powerful tool in research and diagnostics, capable of revealing cellular mechanics in real time, identifying abnormal cells, and sounding the alarm on the presence of pathogens. Still, they are only as powerful as the system used for detection, a key part of which is intelligent selection of excitation wavelength(s). Many fluorescence experiments are performed with a commercial fluorophore like TRITC, Fura-2, or one of the many variants of green fluorescent protein (GFP), in which case determining the best excitation wavelength (or band of wavelengths) is simply a matter of looking up the excitation Occasionally, however, it may be necessary to determine the best excitation wavelength or band for an unknown fluorophore through experiment. US +1 727-733-2447 EUROPE +31 26-3190500 ASIA +86 21-6295-6600 SPECTROMETERS ACCESSORIES SUBSYSTEMS COMPLETE SOLUTIONS There are several approaches that can be taken when choosing an excitation light source for a fluorophore. If using an LED, it is best to choose one with a center wavelength close to the peak excitation spectrum wavelength. If using a laser, the excitation intensity will be so much higher that it is possible to even use a wavelength on the tail of the excitation curve. If using a broadband light source for excitation, it can be filtered using a single bandpass filter, taking care to ensure that the excitation light minimizes overlap with the emission

Although the excitation spectrum for a given fluorophore is not exactly the same as its absorbance, the absorbance spectrum of a fluorophore can be used as a quick indicator of which wavelengths are likely to be good for excitation. When comparing an absorbance and excitation spectrum, most of the peaks will stay the same, though their relative heights may differ. Every Ocean Optics spectrometer has a unique instrument response function (IRF) that characterizes how the spectrometer responds to light across its wavelength range. The IRF arises from multiple wavelength-dependent effects including the attenuation of light in the fiber optic cable, absorbance of light by the mirrors in the spectrometer, the efficiency of the grating, and the responsiveness of the detector. Processed measurement modes like Absorbance, Transmission, Reflectance and Irradiance compensate for the IRF, thus providing accurate spectral shapes. There are multiple measurement modes available in OceanView for measuring fluorescence. The Fluorescence wizard uses QuickView mode, displaying the raw number of counts for each wavelength without any processing or correction for the IRF. When this mode is used for fluorescence measurements, it is important to remember that the IRF can impact the spectral data, showing a peak that s generally in the correct location, but with a distorted shape and/or center wavelength. In Relative Irradiance mode, the instrument response function is corrected by calibrating against a blackbody light source of known color temperature like a tungsten halogen lamp. Relative Irradiance measurements generate a spectrum of relative intensity as a function of wavelength, corrected for the instrument response function. The spectrum is scaled from 0 to 1 in arbitrary units. While QuickView mode is an acceptable option for measuring fluorescence, it is very important to use Relative Irradiance mode when comparing measurements taken by different spectrometers, when determining the spectral shape, or when looking for peak location and shifts. In this experiment, you will use Ocean Optics modular spectroscopy components to configure an absorbance system to measure the absorbance of an unknown fluorophore. You will then use the absorbance spectrum to select the best excitation LED for your fluorophore and reconfigure your modular components to measure fluorescence from the sample. Fluorescence will be measured using two different measurement modes to show the impact of the instrument response function on the shape of the fluorescence Materials QE Pro-ABS spectrometer with interchangeable slits INTSMA-200 interchangeable slit HL-2000 tungsten halogen light source LLS-365 LED light source LLS-470 LED light source Qty. of 2 QP600-2-VIS-NIR 600 µm optical fibers CUV-ALL-UV cuvette holder Qty. of 2 74-MSP mirrored screw plugs Transfer/Beral pipettes Cuvettes Computer with OceanView software installed Unknown fluorophore and solvent used to suspend the fluorophore [e.g., tonic water, chlorophyll extract (see Instructor Notes), fluorescein, rhodamine] Safety Wear safety goggles and other appropriate safety gear during the experiment. Take all proper safety precautions when handling solutions and wear proper eye protection when working with UV light sources. Procedure Determining the Excitation Wavelength for an Unknown Fluorophore 1. Connect the power cord to the HL-2000 light source. Turn the lamp on and allow the spectrometer to warm up at least 15 minutes. 2. Connect the spectrometer to your computer using the USB cable and allow the spectrometer to warm up for at least 15 minutes. 3. Use the fiber to connect the spectrometer to one of the collimating lenses on the cuvette holder.

4. Use the other fiber to connect the light source to a collimating lens opposite the lens to which the spectrometer is connected this is an Absorbance/ Transmission measurement setup. 5. Start the OceanView software. Click the Start button, then select All Programs Ocean Optics OceanView OceanView or use the Desktop shortcut created when you installed the software. 6. Select the Spectroscopy Application Wizards option on the Welcome Screen. optimum value. b. Set Scans to Average to 10 and Boxcar Width to 5 to reduce measurement noise and improve the measurement. You can set Scans to Average to a higher value but this will slow down your acquisitions (total measurement time equals the number of averages multiplied by the integration time). c. Place a checkmark in the Nonlinearity Correction box if this feature is available for your spectrometer. d. Click Next. 10. Click the Store Reference button to store a reference Click Next. 11. Close the shutter on the light source or block the light from entering the spectrometer for your background measurement. Do not turn your light source off. Click the Store Background button to store a background 7. Select the Absorbance (Concentration) option in the Spectroscopy Wizards window to start the Absorbance Wizard. 12. Open the shutter or unblock the light source and click Finish. You are now ready to measure the absorbance spectrum for your unknown fluorophore. 13. The Absorbance spectrum will be displayed in the Absorbance View window. You can adjust the graph appearance using the graph tools above the graph. For example, click the Scale Graph Height to Fill Window button to zoom in on the 8. Select the Absorbance only option. 9. Use a transfer pipette to fill a cuvette ~⅔ full with solvent for your reference measurement. Wipe the cuvette with a KimWipe to remove any fingerprints, place it in the cuvette holder and set your acquisition parameters in the Set Acquisition Parameters window. a. Click the Automatic button Integration Time Automatic to automatically adjust the Integration Time to the 14. Pour the solvent out of the cuvette and use a transfer pipette to fill the cuvette ~⅔ full with the unknown fluorophore. Wipe the cuvette with a KimWipe to remove any fingerprints. Place it in the cuvette holder in the same orientation you used for the reference measurement. The absorbance spectrum for the fluorophore is displayed. 15. Record the wavelength where the maximum absorbance occurs in the table in the Data and Analysis section. 16. Save your absorbance spectrum by clicking the Configure Graph Saving button to configure the

File Writer. a. Select the directory where you want to save the file. b. Enter a filename for your c. Click Apply and then Exit to close the dialog box. installed the software. 2. Select the Spectroscopy Application Wizards option on the Welcome Screen. 17. Click the Save Graph to Files button to save your absorbance 18. Print a copy of the graph showing the unknown fluorophore absorbance spectrum by clicking the Print button. Close the OceanView software. Measuring Fluorescence for an Unknown Fluorophore 1. Reconfigure the spectrometer system for fluorescence measurements. 3. Select the Fluorescence option in the Spectroscopy Wizards window to start the QuickView Fluorescence wizard. a. Change the slit on the spectrometer to a 200 µm slit. b. Disconnect the fiber connecting the light source to the cuvette holder and reconnect it to a collimating lens that is adjacent to the collimating lens connected to the spectrometer. c. Place the 74-MSP mirrored screw plugs into the other two ports of the cuvette holder. The mirrored screw plugs should be adjacent (next to one another) in the cuvette holder. 4. Select the Active Acquisition (Recommended) option. d. Select the best LED for fluorescence excitation based on your absorbance measurement. Record the LED wavelength you selected for fluorescence excitation in the table in the Data and Analysis section. Measuring Fluorescence with the QuickView Fluorescence Wizard 1. Start OceanView. Click the Start button, then select All Programs Ocean Optics OceanView OceanView or use the Desktop shortcut created when you 5. Wipe the cuvette with a KimWipe to remove any fingerprints, place the cuvette containing your unknown fluorophore in the cuvette holder and set your acquisition parameters in the Set Acquisition Parameters window. a. Click the Automatic button Integration Time Automatic to automatically adjust the Integration Time to the optimum value. b. Set Scans to Average to 10 and Boxcar Width to 5 to reduce measurement noise and improve the measurement. Set Scans to Average to a higher or lower value depending on your integration time. Use fewer averages with longer integration times to shorten the total measurement time, if necessary (total measurement time equals the

number of averages multiplied by the integration time). c. Place a checkmark in the Nonlinearity Correction box if this feature is available for your spectrometer. d. Click Next. 6. Block the light from entering the spectrometer. Do not turn your light source off. Click the Store Background button to store a background 7. Unblock the light source and click Finish. You are now ready to measure the fluorescence spectrum for your unknown fluorophore in QuickView Fluorescence mode. 8. The Fluorescence spectrum will be displayed in the View Minus Bkgnd window. You can adjust the graph appearance using the graph tools above the graph. For example, click the Scale Graph Height to Fill Window button to zoom in on the 9. Save your QuickView Fluorescence spectrum by clicking the Configure Graph Saving button to configure the File Writer. a. Select the directory where you want to save the file. b. Enter a filename for your c. Click Apply and then Exit to close the dialog box. 10. Click the Save Graph to Files button to save your QuickView Fluorescence 11. Print a copy of the graph showing the QuickView Fluorescence spectrum for your fluorophore by clicking the Print button. Measuring Fluorescence with the Relative Irradiance Wizard 1. Click the Create a New Spectroscopy Application button in the top menu to open the Spectroscopy Application Wizards window. 2. Select the Relative Irradiance option in the Spectroscopy Wizards window to start the Relative Irradiance wizard. 3. Select the Active Acquisition (Recommended) option. 4. Direct the light from the HL-2000 (or any other blackbody source with a known color temperature) into your spectrometer using an angled sampling accessory like the CVD-DIFFUSE or by rearranging the fibers so they are opposite one another in the cuvette holder. 5. Set your acquisition parameters in the Set Acquisition Parameters window. a. Click the Automatic button Integration Time Automatic to automatically adjust the Integration Time to the optimum value. b. Set Scans to Average to 10 and Boxcar Width to 5 to reduce measurement noise and improve the measurement. Set Scans to Average to a higher or lower value depending on your integration time. Use fewer averages with longer integration times to shorten the total measurement time, if necessary (total measurement time equals the number of averages multiplied by the integration time). c. Place a checkmark in the Nonlinearity Correction box if this feature is available for your spectrometer. d. Click Next. 6. Click the Store Reference button to store a reference Click Next. 7. Close the shutter on the light source or block the light from entering the spectrometer for your background measurement. Do not turn your light source off. Click the

Store Background button to store a background Data and Analysis 8. Open the shutter or unblock the light source and click Next. 9. Enter the color temperature for your blackbody source or select it from the Color Temperature table. Click Finish. Unknown # Wavelength of Maximum Absorbance (λmax) LED Chosen for Excitation (λex) 10. Wipe the cuvette with a KimWipe to remove any fingerprints and place the cuvette containing your unknown fluorophore in the cuvette holder. You are now ready to measure the fluorescence spectrum for your unknown fluorophore in Relative Irradiance mode. 11. The Fluorescence spectrum will be displayed in the RelativeIrradianceView window. You can adjust the graph appearance using the graph tools above the graph. For example, click the Scale Graph Height to Fill Window button to zoom in on the 12. Save your relative irradiance spectrum by clicking the Configure Graph Saving button to configure the File Writer. Compare the spectral data measured in QuickView Fluorescence and Relative Irradiance mode. Do the fluorescence spectra look the same? Does the maximum emission occur at the same peak wavelength? Are the peak shapes the same? Why not? a. Select the directory where you want to save the file. b. Enter a filename for your c. Click Apply and then Exit to close the dialog box. Additional Tasks 1. Try placing 74-MSP mirrored screw plugs at different locations in the cuvette holder to see how the fluorescence intensity changes. Fluorescence Peak Intensity With no 74-MSPs 13. Click the Save Graph to Files button to save your relative irradiance 14. Print a copy of the graph showing the Relative Irradiance Fluorescence spectrum for your fluorophore by clicking the Print button. 74-MSP across from light source 74-MSP across from spectrometer 74-MSP in both locations

2. Excite fluorescence with each LED wavelength and an HL-2000 to see how the fluorescence intensity changes. Record the peak intensity in each case. Fluorescence Peak Intensity LLS-365 LLS-470 www.oceanoptics.com HL-2000 Instructor Notes Chlorophyll has a strong fluorescence spectrum and is easily extracted from dark, green leaves like spinach using rubbing alcohol. Prepare the extract by tearing spinach or other dark, green leaves into small pieces and placing them in rubbing alcohol. The solution will turn green over time as the chlorophyll is extracted from the leaves. info@oceanoptics.com US +1 727-733-2447 EUROPE +31 26-3190500 ASIA +86 21-6295-6600 SPECTROMETERS ACCESSORIES SUBSYSTEMS COMPLETE SOLUTIONS Contact us today for more information on setting up your spectroscopy system from Ocean Optics. The Innovations in Educational Spectroscopy Grant Program provides resources to public and private teaching institutions. The program uses spectroscopy as a general-purpose measurement tool to promote the use of modern instrumentation and technology in science and engineering curricula. Visit oceanoptics.com to learn more and apply.