The following document can be provided to an Engineer, Contractor, or Owner to allow them to

SECTION COOLING TOWER

Lenntech. Tel Fax / Marley MS Cooling Tower /

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

The following document can be provided to an Engineer, Contractor, or Owner to allow them to properly specify MESAN s MXR-KM series Cooling Towers.

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

IMT Open Cooling Towers... B78. Benefits... B80. Construction Details... B82. Custom Features and Options... B83. Accessories...

Water headers are made of reinforced plastic and the design of the spray tree ensures uniform water distribution.

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL

ACF SERIES COUNTER FLOW COOLING TOWER ENGINEERING DATA

Central Station Air Handler Specification

VANGUARD Packed Column Air Stripping Tower Specifications

/ Marley Series 10 Series 15 Cooling Tower /

SERIES COOLING TOWER 300, 400, 500 & 600 CLASS DIRTY WATER HIGH TEMPERATURE DURABILITY. Heavy Duty Crossflow Splash Filled Type

special needs surface trajectory costs. High Efficiency 3. 4.

SECTION FUEL-FIRED UNIT HEATERS

QuadraFlow cooling tower

ACX Series Cross Flow Induced Draft Cooling Towers

SECTION ROOF EDGE SAFETY RAILING SYSTEM

Diffused Aeration Piping Equipment

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

OXF-30K INDUCED DRAUGHT CROSSFLOW FRP COOLING TOWER

NRM-7000 Guide Specifications

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

VANGUARD Packed Column Air Stripping Tower Specifications

13340 FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE

Specifications for FL-100 Soffit Panel

SECTION AWNINGS

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

HOTEL SPECIFICATION SECTION 08100

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

SCOPE OF WORKS COOLING TOWER & CWTP PACKAGE (PLOT PLAN & WATER) SCOPE OF WORKS BEARING COOLING TOWER & CWTP PACKAGE

FXT Open Cooling Towers... B46. Benefits... B48. Construction Details... B49. Custom Features and Options... B50. Accessories...

PRASAR BHARATI (India s Public Service Broadcaster) OFFICE OF THE ADDL. DIRECTOR GENERAL (E)(EZ) ALL INDIA RADIO & TELEVISION, KOLKATA

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SECTION PRE-ENGINEERED METAL BUILDING

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

SECTION DETAILS (MECHANICALLY ASSEMBLY)

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

Introducing the Marley MD Cooling Tower. / We re bringing something new to packaged counterflow towers. / Our name.

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY

Architectural Roof and Wall Products Guide Specifications

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

Compass Series Open Cooling Towers BAC AUSTRALIA

E. Fume hood to have set baffling system. No adjustable baffles allowed.

NOTE TO SPECIFYING ARCHITECT REGARDING SECTION CONTOUR CURTAIN AND MOTOR

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION METAL ATHLETIC LOCKERS

SECTION HVAC GRAVITY VENTILATORS

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

SECTION METAL EQUIPMENT LOCKERS

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

ITEM 442 METALS FOR STRUCTURES

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

The Uncloggable Roof Drain Dome LIT-058

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Galvanized System

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

SUBMERSIBLE SEWAGE EJECTOR

Specification Section XXXXX Interior Water walls

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

B. Pumps are to be manufactured by Flygt Pumps. No substitutes will be considered.

SECTION ALUMINUM HANDRAIL SYSTEMS

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

1. ARI 410 Standard for chilled water, hot water and steam coils. 2. ARI 430 Central Station Air Handling Units

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION EXHAUST FANS PART 1 GENERAL

SPECIFICATIONS SECTION UL LISTED HEAT AND SMOKE VENTS

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.

SAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)

Architectural Roof and Wall Products Guide Specifications

APPLICABLE UNDER SECTIONS: SOLAR ENERGY HEATING EQUIPMENT SOLAR HEATING COLLECTORS METAL WALL PANELS

SUBMERSIBLE PUMPS FOR WASTEWATER (S-114)

SECTION [ ] MANUFACTURED METAL BOLLARDS

ROOF DRAINS TABLE OF CONTENTS

SECTION 401 WATER PIPE AND FITTINGS 2.2 POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SAMPLE SPECIFICATIONS FOR PREFABRICATED FRP LIFT STATIONS

Transcription:

Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com TM Series Induced Draft Cooling Tower Specifications The TM Series cooling towers are induced draft counter-flow cooling towers with single module capacities from 250 to 2020 cooling tons. These towers are a modular design that Delta Cooling Towers introduced in 2001 and have been very well received in both commercial and industrial applications. There are three overriding principles that make TM Series cooling towers an excellent selection. The towers are corrosion-proof not corrosion-protected which is an important distinction of Delta towers. Cooling towers are outdoor equipment, either on roofs or sides of buildings, and are subjected to weather extremes continuously. Delta towers are manufactured in a seamless engineered plastic (HDPE) structural shell which is corrosion-proof and will not rust, chip, peel, crack or ever need painting or additional protective coatings. Comparably priced towers are often sheet metal with a galvanized coating. Zinc galvanizing provides only an interim protection against corrosion. This galvanizing wears away, often unevenly, exposing sheet metal to the rapid corrosive environment of cooling tower duty. The second principle of Delta towers is the engineering that led to a simplicity of design, translating into reliability and a trouble-free life of the towers. From the seamless cooling tower shell to the direct drive fan assembly, there are less overall components and systems within the tower to maintain. The towers are shipped factory complete with little more installation steps than hooking up the electrical and water. This design simplicity is recognized in many other industries as a key goal and leads to greater reliability and owner peace of mind. Finally, the TM Series Induced Draft Cooling Towers are a high efficiency design which translates to very low energy costs to operate the towers. The design of the towers and the proprietary high efficiency fill material lead to this energy efficiency. The minimal operating costs, a track record of superior reliability and corrosion proof materials of construction makes the TM Series Induced Draft Cooling Tower the choice for cooling tower applications over 250 cooling tons.

Delta Cooling Towers, Inc, TM Series Induced Draft Cooling Tower Specifications, Page 2 of 5 TM SERIES INDUCED DRAFT COOLING TOWER PART 1 GENERAL 1.1 SCOPE Work included to furnish and install Delta Cooling Tower model TM- consisting of all equipment necessary to provide a complete operating system to remove specified heat load. Cooling towers shall be packaged, factory pre-assembled to the fullest extent possible, induced draft, counter flow design 1.2 RELATED WORK {insert related work document here} 1.3 REFERENCES - STANDARDS AMCA - Air Moving and Conditioning Association ASTM - American Society for Testing and Materials ANSI - American National Standards Institute ASME - American Society of Mechanical Engineers 1.4 QUALIFICATIONS The cooling tower shall be manufactured by a company with at least 30 years experience manufacturer of seamless engineered polyethylene cooling tower systems. 1.5 WARRANTY Shell shall be warranted for 15 years and all other equipment shall be warranted for one year against material and workmanship defects from date of shipment. 1.6 SUBMITTALS Shop drawings shall be provided and shall include but not be limited to: A. System dimension B. Operating and dry weight C. Details of equipment D. Mounting and support requirements E. Descriptions and specifications

Delta Cooling Towers, Inc, TM Series Induced Draft Cooling Tower Specifications, Page 3 of 5 PART 2 PRODUCT The cooling tower specified shall be factory assembled to the fullest extent possible. 2.1 Induced Draft Cooling Tower, Model TM-, tons capacity, GPM, F hot water temperature, F cold water temperature, F wet bulb temperature A. Cooling tower 1. Shell shall be seamless, double wall, non-corrosive, hi-impact high density polyethylene (HDPE) of leak proof design. Conical transition for motor/fan assembly with separate polyethylene velocity recovery stacks. The shell shall exceed 1/4" average thickness. The structural shell shall be capable of withstanding water temperatures up to 160 F on a continual basis. 2. Sump shall be seamless, double wall, non-corrosive, hi-impact high density polyethylene (HDPE) of leak proof design. Sump will have I-Beam support pockets allowing placement on elevated I-Beams. Integral support posts 360 around sump give support to upper tower section and allow mounting of removable louvered air inlet panels for optimum air distribution. 3. Cooling tower structural shell & sump shall be guaranteed against corrosion for 15 years. 4. Cooling towers performance to be certified by CTI (Cooling Technology Institute) under CTI Standard-201. 5. Removable PVC louver panel located between sump support post for accessibility to automatic make-up valve and adjustable float. 6. PVC fittings shall be provided for inlet, outlet, overflow, drain and make up. 7. Outlet fitting for pump suction applications shall be provided with a vortex breaker. 8. Make up assembly shall be incorporated in the sump of the cooling tower. It shall be a mechanical valve assembly, adjustable height for varying operating condition.

Delta Cooling Towers, Inc, TM Series Induced Draft Cooling Tower Specifications, Page 4 of 5 The engineered plastic shell is the optimum material for cooling tower construction. The material is molded into a totally seamless shell, which will never leak, unlike conventional cooling towers which require many panels, joints, seams, seam gaskets, caulking and hundreds of bolts or other fasteners to maintain the integrity of the product. The Delta structural shell will never rust, chip, crack or ever need painting or further protective coatings. The structural shell is warranted for 15 years which is much longer than other available cooling towers Galvanized steel towers provide only interim corrosion protection. The zinc galvanizing is designed only to delay corrosion as the zinc wears steadily away. Moderately high temperatures and various water chemical treatments speed up this leaching of zinc into the water or atmosphere. With only ounces per square foot of corrosion protection, it is only a matter of time till corrosion of the underlying sheet steel sets in. Thin fiberglass panels can also not match the structural integrity of Deltas' seamless engineered plastic. Over time, if that long, leaks can develop at the joints even with gaskets and caulking applied. Thin fiberglass when exposed to the wide range of outdoor weather elements is also subject to delaminating, wicking and overall degradation. B. Water distribution Totally enclosed, non-corrosive, polyvinyl chloride (PVC) pipe with large orifice non-clog spray nozzle distribution system. Threaded nozzle orifices shall be interchangeable allowing substitution of larger diameter orifice for increased flow conditions without increasing inlet pressure. C. Wet decking Rigid PVC film, corrugated and bonded for maximum cooling efficiency. D. Drift eliminator Drift eliminator shall be three pass non-corrosive, polyvinyl chloride (PVC) corrugated and bonded, one-piece, with non-corrosive PVC straps for easy removal for internal inspection and maintenance. E. Fan Assembly 1. Fan propellers shall be adjustable pitch direct drive. Fan blades shall be constructed of fiberglass reinforced polypropylene with aluminum silicon alloy hub and stainless steel hardware. Statically and dynamically balanced prior to shipping. 2. Fans and motors shall be supported by heavy gauge angled steel ring. The fan ring shall be coated with a premium Heresite for corrosion protection.

Delta Cooling Towers, Inc, TM Series Induced Draft Cooling Tower Specifications, Page 5 of 5 3. Motor shall be Totally Enclosed Air Over, Direct Drive, 900 RPM, Class F insulation, with 1.15 minimum service factor and specifically designed for cooling tower duty. 4. Motor shall be warranted against defects in materials and workmanship under motor manufactures warranty. 5. Fan guards shall be mounted to top of velocity recovery stacks. Guards shall be coated steel mesh, with 2 ¾ open area to allow air to pass through with minimum pressure loss while protecting personnel from contacting the rotating fan propeller. Propeller type fan is attached to the shaft of the motor. The direct drive system has a twofold benefit. First and foremost, there are no extra bearings, pulleys, gear reducers or additional shafts to maintain or fail. The second benefit is the higher efficiency gained by connecting the motor to the motor shaft, there are no losses due to friction from,bearings and gears, thus providing the highest efficiency available. F. Hardware All fasteners are 304 stainless steel. Anchoring lugs are Heresite coated steel. PART 3 EXECUTION 1. GENERAL - INSTALLATION Installation of equipment shall be in conformance with the manufacturers recommendations. 2. TESTING A. Contractor shall perform all field testing and final adjustment of cooling tower equipment in accordance with provision of manufacturer. B. Contractor shall certify that all operation criteria are within normal operating range as specified by the manufacturer. C. Should any part of the cooling tower equipment fail to meet any specified requirement, adjust, repair or replace any and all defects or inoperative parts immediately with manufacturers recommended parts or procedures.