TEST REPORT. Report No.: A Rendered to: TUBELITE, INC. Walker, Michigan

Similar documents
TEST REPORT. Report No.: B Rendered to: MI WINDOWS AND DOORS, INC. Gratz, Pennsylvania

TEST REPORT. Report No.: A Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: LEED HIMMEL INDUSTRIES, INC. Hamden, Connecticut

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: ALUMIL US. SERIES/MODEL: M300 Falcon PRODUCT TYPE: Aluminum Horizontal Sliding Window (XO)

PERFORMANCE TEST REPORT. Report No.: H Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: F Rendered to: MI WINDOWS AND DOORS, LLC Gratz, Pennsylvania

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

TEST REPORT. Rendered to: EARTHWISE GROUP, LLC Liberty Township, Ohio

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Structural Performance Certification Authorization Report

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: MGM WINDOW COMPANY Hendersonville, Tennessee

AAMA 506 TEST REPORT. Report No.: G Rendered to: VEKA INC. Fombell, Pennsylvania

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

INTERNATIONAL WINDOW TEST REPORT

TEST REPORT. ASSOCIATED MATERIALS, INCORPORATED Cuyahoga Falls, Ohio. Rendered to: PRODUCT TYPE: Fixed Window SERIES/MODEL: A780 SPECIFICATIONS:

Structural Performance Certification Authorization Report

Structural Performance Certification Authorization Report

Architectural Testing TEST REPORT. Rendered to: COEUR D'ALENE WINDOW Spokane Valley, Washington. PRODUCT TYPE: PVC Fixed Window SERIES/MODEL: 3310

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

Structural Performance Certification Authorization Report

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America Inc. SERIES/MODEL: VCM/VCE B PRODUCT TYPE: Venting Curb Mounted Skylight

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

Dennis Fassnacht Jr :59:35-04'00'

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: BUILDERS ACCESSORIES, INC.

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to:

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

TEST REPORT. Report No.: F Rendered to: FAIRFIELD METAL, LLC Fairfield, New Jersey

TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC Marshall, Arkansas. Cycles 2,000,000. Summary of Results

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: WASHOE EQUIPMENT, INC. DBA SUNOPTICS PRISMATIC SKYLIGHTS

OSHA FALL PROTECTION TEST REPORT. Rendered to: SERIES/MODEL: FS S PRODUCT TYPE: Fixed Deck Mounted Skylight

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT. Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

TEST REPORT. Rendered to: ALL WEATHER INSULATED PANELS Vacaville, California. PRODUCT TYPE: Wall Panels SERIES/MODEL: DM45 Series

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America LLC. SERIES/MODEL: FCM B PRODUCT TYPE: Fixed Glass Glazed Curb Mount Skylight

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS & DOORS. SERIES/MODEL: Norwood 3070HI OOX PRODUCT TYPE: Sliding Glass Door

TEST REPORT. Report No.: F Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT. Report No.: B Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX AMERICA INC. SERIES/MODEL: CAP-1 PRODUCT TYPE: Fixed Acrylic Glazed Skylight

TEST REPORT. Rendered to: All Weather Insulated Panels Vacaville, California. PRODUCT TYPE: Roofing Panels SERIES/MODEL: SR Series

TEST REPORT. Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

MOCK-UP TEST REPORT. Rendered to: TUBELITE INC. PROJECT: 300 ES Interior Glazed Curtain Wall

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: C.R. LAURENCE CO., INC. SERIES/MODEL: S80 Monterey. TYPE: Bi-fold Door

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: BRICK-IT. SERIES/MODEL: Brick Veneer Panel Systems PRODUCT TYPE: Wall Panel Systems

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

TEST REPORT ASTM E331. Report No.: E Rendered to: IMISON USA Houston, Texas

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

TEST REPORT. Rendered to: AD SKYLIGHTS, INC. Algonquin, Illinois. AD Skylight without Guard

PERFORMANCE TEST REPORT. Rendered to: ALL-WEATHER INSULATED PANELS. SERIES/MODEL: SM40 PRODUCT TYPE: Insulated Sandwich Wall Panel

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: COASTAL INNOVATIVE PRODUCTS

TEST REPORT. Report No.: F Rendered to: ALTECH PANEL SYSTEMS, LLC Cartersville, Georgia

G R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Vinyl

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 390. TYPE: Sliding Glass Door

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 6/8 Sliding Patio Door

AAMA 1801 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 420/430/440. TYPE: Sliding Glass Door

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 900 Series. TYPE: Out-swing Double Terrace Door

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: CUSTOM VINYL PRODUCTS, LLC SERIES/MODEL: SHA4. TYPE: Single Hung Window

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: ALL SEASONS DOOR & WINDOW, MFG SERIES/MODEL: A500. TYPE: Double Hung Window

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: GAMCO CORPORATION. SERIES/MODEL: Curtain Wall TYPE: Glazed Wall Systems (Site-built)

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: GAMCO CORPORATION. SERIES/MODEL: W250C Awning TYPE: Projecting (Awning)

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door with Impact Glass

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Classic-Craft, Fiber Classic, and Smooth Star

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: GAMCO CORPORATION. Series/Model: CW250

AAMA/WDMA/CSA 101/I.S.2/A440-08

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Polyvinyl Chloride (PVC)

AAMA 1801 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 185/3185 SP. TYPE: Picture Window

ETC Laboratories Measuring Up To Your Standards And More

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: MGM INDUSTRIES. SERIES/MODEL: 4600 Double Hung

STRUCTURAL PERFORMANCE TEST REPORT. Series Casement (Rep/Impact/AAMA) C-C70 940mm x 1930mm (37 x 76 )

AAMA/WDMA/CSA 101/I.S.2/A440-08

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

KNOTWOOD, A DIVISION OF OMNIMAX INTERNATIONAL MIAMI-DADE TEST REPORT

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: TUBELITE, INC.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: CUSTOM VINYL PRODUCTS, LLC

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Intertek NAFS-11 Testing

TEST REPORT. Rendered to: ROCKSTEADY, LLC Lititz, Pennsylvania. PRODUCT TYPE: Drywall Clip

TEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post

TEST REPORT. Report No.: C Rendered to: ROCKSTEADY, LLC Lititz, Pennsylvania. PRODUCT TYPE: Drywall Clip

CR LAURENCE CO, INC. ACOUSTICAL PERFORMANCE TEST REPORT

TEST REPORT. Rendered to: FAIRWAY BUILDING PRODUCTS, LP. For: Solutions Aluminum Guardrail System with Glass Balustrades

CR LAURENCE CO, INC. ACOUSTICAL PERFORMANCE TEST REPORT

TEST REPORT AAMA 501.5

TEST REPORT. Report No.: H Rendered to: GEORGIA-PACIFIC WOOD PRODUCTS, LLC Atlanta, Georgia

SECTION ALUMINUM STORM WINDOWS

Construction Consulting Laboratory, International

Transcription:

Architectural Testing TEST REPORT Report No.: A2941.01 109 44 Rendered to: TUBELITE, INC. Walker, Michigan PRODUCT TYPE: Aluminum Side Hinge Door SERIES/MODEL: Thermal=Block Summary of Results Title Test Specimen #1 Test Specimen #2 Design Pressure ±2400 Pa (±50.13 psf) N/A Air Infiltration 1.1 L/s/m 2 (0.21 cfm/ft 2 ) 0.4 L/s/m 2 (0.07 cfm/ft 2 ) Water Penetration Resistance Test Pressure 000 Pa (00.00 psf) (LW) 220 Pa (4.59 psf) Uniform Load Structural Test Pressure ±3600 Pa (±75.19 psf) N/A Reference must be made to Report No. A2941.01 109 44, dated 04/28/11 for complete test specimen description and detailed test results.

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 1 of 8 1.0 Report Issued To: Tubelite, Inc. 3056 Walker Ridge Drive NW Suite G Walker, Michigan 49544 2.0 Test Laboratory: Architectural Testing, Inc. 130 Derry Court York, Pennsylvania 17406 8405 717 764 7700 3.0 Project Summary: 3.1 Product Type: Aluminum Side Hinge Door 3.2 Series/Model: Thermal=Block 3.3 Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). Test specimen description and results are reported herein. 3.4 Test Date: 02/22/2011 02/23/2011 3.5 Test Location: Architectural Testing, Inc. test facility in York, Pennsylvania. 3.6 Test Sample Source: The test specimens were provided by the client. Representative samples of the test specimen(s) will be retained by Architectural Testing for a minimum of four years from the test completion date. 3.7 Drawing Reference: The test specimen drawings have been reviewed by Architectural Testing and are representative of the test specimen(s) reported herein. Test specimen construction was verified by Architectural Testing per the drawings located in Appendix B. Any deviations are documented herein or on the drawings. 3.8 List of Official Observers: Name Company Tram Trinh Steven Bucher Michael D. Stremmel, P.E. Scott Gill Tubelite, Inc. United Plate Glass Architectural Testing, Inc. Architectural Testing, Inc. www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 2 of 8 4.0 Test Method(s): ASTM E 283 04, Test Method for Determining Rate of Airflow Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen. ASTM E 330 02, Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. ASTM E 331 00, Test Method for Water Penetration of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. ASTM E 547 00, Test Method for Water Penetration of Exterior Windows, Curtain Walls and Doors by Cyclic Static Air Pressure Difference. ASTM E 2068 00, Standard Test Method to Determine the Operating and Breakaway Forces of Sliding Windows and Doors. ANSI BHMA A156.2, American National Standard for Bored and Preassembled Locks and Latches. 5.0 Test Specimen Description: 5.1 Product Sizes: Test Specimen #1: Overall Area: Width Height 2.3 m² (24.3 ft 2 ) millimeters inches millimeters inches Overall size 1029 40 1/2 2191 86 1/4 Panel size 914 36 2115 83 1/4 Test Specimen #2: Overall Area: Width Height 2.3 m² (24.3 ft 2 ) millimeters inches millimeters inches Overall size 1029 40 1/2 2191 86 1/4 Panel size 914 36 2115 83 1/4 www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 3 of 8 5.0 Test Specimen Description: (Continued) 5.2 Frame Construction: The following descriptions apply to all specimens. Frame Member Material Description Head Aluminum Thermal improved, dual strutted extruded aluminum. The head utilized a snap on extruded aluminum door stop. Sill Aluminum Thermal improved, poured and debridged extruded aluminum. Thermal improved, dual strutted extruded aluminum. The jambs utilized a snap on extruded Jambs Aluminum aluminum door stop. The hinge jamb utilized a hinge mounting plate, secured to the jamb six #12 x 1/2" long screws. Head/jamb corners Threshold/jamb corners Joinery Type Square cut and butted Square cut and butted Detail Sealed with silicone and secured with three #10 x 1" long screws. Sealed with silicone and secured with an aluminum clip. The clip was secured to the jamb with two #12 x 1/2" long screws and secured to the threshold with one #12 x 1/2" long screw. www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 4 of 8 5.0 Test Specimen Description: (Continued) 5.3 Leaf Construction: Leaf Member Material Description Leaf stiles Aluminum Thermal improved, dual strutted extruded aluminum. Leaf rails Aluminum Thermal improved, dual strutted extruded aluminum. The top and bottom rails utilized a full length snap on vinyl cap. The bottom rail utilized a metal sweep on the interior face, secured to the bottom rail with four #6 x 1/2" long screws spaced 10" on center. All corners Joinery Type Square cut and butted Detail Corners were secured using an aluminum clip that was snapped into the glazing grooves of each stile end with a 3/8" diameter threaded rod running through each clip along the full length of the top and bottom rails with a metal clip and hex nut at each end inside the stile hollow. 5.4 Weatherstripping: 5.4.1 Test Specimen #1: Description Quantity Location 0.270" backed by 0.300" high polypile with fin 1 Row Head and jambs Custom shaped Kerf mounted vinyl flap seal 1 Row Interior of the bottom rail 5.4.2 Test Specimen #2: Description Quantity Location 0.270" backed by 0.300" high vinyl hollow bulb seal 1 Row Head and jambs Custom shaped Kerf mounted vinyl flap seal 1 Row Interior of the bottom rail www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 5 of 8 5.0 Test Specimen Description: (Continued) 5.5 Glazing: Glass Type 1" IG Spacer Type Aluminum box Interior Lite 1/4" thick tempered Exterior Lite 1/4" thick tempered Glazing Method The glass was channel glazed at each jamb with interior and exterior glazing gaskets. The glass was secured at the top and bottom with snap in interior and exterior glazing beads with vinyl wedge gaskets against the glass. Daylight Opening Location Quantity Glass Bite millimeters inches Leaf 1 641 x 1702 25 1/4 x 67 1/2" 5.6 Drainage: A sloped threshold was utilized. 5.7 Hardware: Description Quantity Location Lock with handle 1 Lock stile, 40" from the sill Continuous (piano) hinge 1 Hinge stile 5.8 Reinforcement: No reinforcement was utilized. 6.0 Installation: The specimen was installed into a Spruce Pine Fir wood buck. The rough opening allowed for a 1/16" shim space. The exterior perimeter of the window was sealed with sealant. Location Anchor Description Anchor Location Jambs 4" long extruded aluminum clip, snap fit into the jambs and secured to the wood buck with one 12" from each end #12 x 3 1/4" long flat head screw. Sill #12 x 3 1/4"long flat head screw 3" from each end and midspan www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 6 of 8 7.0 Test Results: The temperature during testing was 22 C (71 F). The results are tabulated as follows: Test Specimen #1: Title of Test Results Allowed Note Operating Force, per ASTM E 2068 Air Leakage, per ASTM E 283 at 75 Pa (1.6 psf) Force to latch: 36 N (8.0 lbf) N/A 1.1 L/s/m 2 (0.21 cfm/ft 2 ) N/A Water Penetration, per ASTM E 331 at 000 Pa (00.00 psf) (limited water) Pass No leakage 1 Uniform Load Deflection, per ASTM E 330 taken at bottom rail +1440 Pa (+30.08 psf) 1440 Pa ( 30.08 psf) Uniform Load Structural, per ASTM E 330 taken at bottom rail +2160 Pa (+45.11 psf) 2160 Pa ( 45.11 psf) Uniform Load Deflection, per ASTM E 330 taken at bottom rail +2400 Pa (+50.13 psf) 2400 Pa ( 50.13 psf) Uniform Load Structural, per ASTM E 330 taken at bottom rail +3600 Pa (+75.19 psf) 3600 Pa ( 75.19 psf) 0.3 mm (0.01") 0.3 mm (0.01") N/A 2, 3 <0.3 mm (<0.01") <0.3 mm (<0.01") N/A 2, 3 0.8 mm (0.03") 0.8 mm (0.03") N/A 2, 3 <0.3 mm (<0.01") <0.3 mm (<0.01") N/A 2, 3 www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 7 of 8 7.0 Test Results: (Continued) Test Specimen #2: Title of Test Results Allowed Note Air Leakage, per ASTM E 283 at 75 Pa (1.6 psf) 0.4 L/s/m 2 (0.07 cfm/ft 2 ) N/A Water Penetration, per ASTM E 547 and ASTM E 331 at 220 Pa (4.59 psf) Pass No leakage 1 General Note: All testing was performed in accordance with the referenced standard(s). Note 1: Without insect screen. Note 2: Loads were held for 10 seconds. Note 3: Tape and film were used to seal against air leakage during structural testing. In our opinion, the tape and film did not influence the results of the test. www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Page 8 of 8 The service life of this report will expire on the stated Test Record Retention End Date, at which time such materials as drawings, data sheets, samples of test specimens, copies of this report, and any other pertinent project documentation, shall be discarded without notice. If test specimen contains glazing, no conclusions of any kind regarding the adequacy or inadequacy of the glass in any glazed test specimen(s) can be made. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, Inc. Scott Gill Senior Technician Michael D. Stremmel, P.E. Senior Project Engineer SG:dem Attachments (pages): This report is complete only when all attachments listed are included. Appendix A: Photograph (1) Appendix B: Drawings (11) This report produced from controlled document template ATI 00479, issued 03/01/11. www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Appendix A Photograph Photo No. 1 View of Tested Door www.archtest.com

Test Report No.: A2941.01 109 44 Report Date: 04/28/11 Test Record Retention End Date: 02/23/15 Appendix B Drawings www.archtest.com