SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

Similar documents
SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

H D P SOLID PHENOLIC FLOOR BRACED COMPARTMENTS SECTION FB TOILET PARTITIONS

H D P SOLID PHENOLIC CEILING HUNG COMPARTMENTS SECTION CH TOILET PARTITIONS

AD 0 O~ Partitions, Inc East La Palma Avenue - Anaheim, California Ph: and Fax:

PLASTIC LAMINATED COMPARTMENTS SECTION TOILET PARTITIONS

HDPE SOLID POLYMER-PLASTIC FLOOR BRACED COMPARTMENTS SECTION FB WEIS/POLY TOILET PARTITIONS

SECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

PLASTIC LAMINATED FLOOR TO CEILING COMPARTMENTS SECTION FC TOILET PARTITIONS

HDPE SOLID POLYMER-PLASTIC FLOOR TO CEILING COMPARTMENTS SECTION FC WEIS/POLY TOILET PARTITIONS

SECTION SOLID PLASTIC TOILET PARTITIONS. A. Section Includes: Toilet partitions and urinal screens, complete with hardware.

10155 Toilet Compartments

PRODUCT SPECIFICATIONS - SERIES 1090

B. LEED Submittals (Projects authorized for LEED certification only)

SOLID PLASTIC TOILET PARTITIONS. A. Section Includes: Toilet partitions and urinal screens, complete with hardware.

SECTION TOILET COMPARTMENTS SPEC WRITER NOTES:

Bradley Bradmar Plastic Toilet Partitions

Bradley Mills Plastic Laminate Toilet Partitions

Privacy Plus Partitions

Missouri S&T Bullman Showers Date: February 13, 2017 Project No SECTION PLASTIC SHOWER AND DRESSING COMPARTMENTS

SECTION SOLID COLOR REINFORCED COMPOSITE TOILET PARTITIONS

SECTION PLASTIC TOILET COMPARTMENTS

Specification Floor-To-Ceiling Solid Plastic Toilet Compartments

SECTION TOILET COMPARTMENTS

Bradley Mills Stainless Steel Toilet Partitions

A2.0 TRIPLE M DEVELOPMENT EXTERIOR ELEVATIONS. Rochester, MN Hwy 52 North. Apr 07, phone fax

.1 Underwriters' Laboratories of Canada (ULC)..1 CAN/ULC-S102-M88(R2000), Surface Burning Characteristics of Building Materials and Assemblies.

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

Hamilton International Air Cargo Logistics Facility Section November 2014 Page 1 of 4

SECTION WALL AND DOOR PROTECTION

SECTION ACCORDION FOLDING PARTITIONS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

UNIFIED FACILITIES GUIDE SPECIFICATIONS. References are in agreement with UMRL dated January 2018

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION SHOWER AND DRESSING COMPARTMENTS

SECTION IMPACT RESISTANT WALL PROTECTION

Architectural Specifications, Section Phenolic Lockers

SECTION METAL ATHLETIC LOCKERS

All proposals will be evaluated by a district committee. The following criteria/weighting will be used to evaluate each proposal:

Sanymetal Partitions

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION NON-STRUCTURAL METAL FRAMING

SECTION METAL EQUIPMENT LOCKERS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION PREFABRICATED SHOWER COMPARTMENTS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

COMMERCIAL ITEM DESCRIPTION PARTITIONS, TOILET, COMPLETE

A This Section includes stock, manufactured toilet compartments.

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION METAL ATHLETIC LOCKERS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

10331 Date Street Murrieta, CA SECTION HYBRID LAMINATE LOCKERS W/ PHENOLIC DOORS

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

SECTION METAL STUDENT LOCKERS

SECTION METAL LOCKERS

Construction Standards PAGE

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

PH6000. Key Features

.6 ASTM D696 Coefficient of Linear Thermal Expansion

1. Standard two tier metal lockers and metal base.

SECTION ORNAMENTAL WELDED STEEL FENCING

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Model STORM GRILLE Brick or Straight Pattern High Stress Rolling Grilles

A. Access doors and frames are part of an access door and frame allowance.

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION MISCELLANEOUS METALS

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND


NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

ACCU TEC MANUFACTURING, INC 1027 SOUTH LINWOOD AVE SANTA ANA, CA FAX Solid Phenolic Lockers

Doc

SECTION TOILET AND BATH ACCESSORIES ADDENDUM NO.4

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

1.3 SHOP DRAWINGS.1 Make all submittals in accordance with Division 1, General Requirements

Aluminum Perforated Rolling Door

SPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION ACCESS DOORS AND FRAMES

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Preassembled steel stairs with concrete-filled treads.

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302)

SECTION ORNAMENTAL ALUMINUM RAILING

Aluminum-Framed Entrances and Storefronts

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

Transcription:

SECTION 102113 TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Solid composite phenolic toilet compartments and urinal screens. 1.02 RELATED SECTIONS A. Documents affecting work in this section includes but is not limited to the General Conditions, Supplementary Conditions and Sections in Division 1 General Requirements of these Specifications. B. 051000 - Structural Metal Framing; for backing in metal framed walls. C. 061000 - Finish Carpentry; for backing in wood framed walls. D. 101850 - Shower Enclosures. E. 105100 - Lockers. F. 108000 - Toilet Accessories. 1.03 DESCRIPTION A. Toilet and Shower Compartments (Commercial, Institutional, or No-Sightline): 1. Ceiling hung type units consisting of Trespa pilasters, panels, and doors, plated steel leveling devices with stainless steel covers; and stainless steel fittings, hardware, and fastenings necessary for complete installation. 2. Floor supported type units consisting of Trespa pilasters, panels and doors; plated steel leveling devices with stainless steel covers; and stainless steel fittings, hardware and fastenings necessary for complete installation. 3. Overhead braced type units consisting of Trespa pilasters, panels and doors; plated steel leveling devices with stainless steel covers; aluminum overhead bracing, and stainless steel fittings, hardware and fastenings necessary for complete installation. B. Urinal Screens: 1. Wall hung type consisting of Trespa screen panels and stainless steel fittings and fastening necessary for complete installation. 2. Floor supported type units consisting of Trespa pilasters and screen panels; plated steel leveling devices with stainless steel covers, and stainless steel

1.04 REFERENCES fittings and fastenings necessary for complete installation. A. ASTM A167-92b - Stainless and Heat Resisting Chromium Nickel Steel Plated Sheet and Strip. B. ASTM E-84-91a - Surface Burning Characteristics of Building Materials. 1.05 SUBMITTALS A. Submittals, procedures and quantities are specified in Section 01300. B. Shop drawings: Submit shop drawings indicating elevations of partitions, thickness of Trespa, fastenings, proposed method of anchoring, size and spacing of anchors, details of construction, hardware, fittings, mountings and other related items and installation details. C. Product Data: Submit manufacturer's technical data for materials, fabrication, finishing, fastenings, hardware, and installation details. D. Samples: Submit samples of color and pattern selected for verification. 1.06 REGULATORY REQUIREMENTS A. Accessibility Requirements: Comply with the requirements for the accessibility of the physically disabled of the appropriate jurisdiction and ADA Accessibility guidelines for Buildings and Facilities of June 26, 1991. B. Surface Burning Requirements: The panels to have the following surface burning characteristics and smoke generation values per U.L. Classification and labeling in accordance with ASTM E-84 tests and shall be self-extinguishing. 1. Flame spread: 25 for 3/4" thick panels; 30 for 1/2" thick panels. 2. Smoke developed: 70 for 3/4" thick panels; 85 for 1/2" thick panels. 1.07 DELIVERY, STORAGE AND HANDLING A. Deliver and store materials in the manufacturer's original protective packaging. Store materials in an enclosed shelter providing protection from damage and exposure to the elements. 1.08 COORDINATION A. Field Measurements: Secure field measurements before preparation of shop drawings and fabrication where possible, for proper and adequate fabrication and installation of the work.

B. Furnish inserts and anchorage built into other construction for installation of toilet compartments and urinal screens. 1.09 WARRANTY A. Trespa panels to be warranted for 10 years against delamination. The factory authorized fabricator, product installer and phenolic manufacturer must sign the warranty and submit a copy to the General Contractor. The project name must be written on the warranty. PART 2 - PRODUCTS 2.01 ACCEPTABLE MANUFACTURER A. Drawings and specifications are based on lockers fabricated using Trespa solid phenolic panels: Trespa North America, 800-487-3772. 1. Represented locally by W.H. Steele Co., 909-930-0831, E-Mail: info@whsteele.com. B. Approved Fabricators: 1. Accutec Manufacturing, Santa Ana, CA 714-549-2015. 2. Alan Lewis Inc., Santa Ana, CA 714-434-9407. 3. Laminating Technologies, Anaheim, CA 714-632-8696. 2.02 MATERIALS A. Partition panels, pilasters, doors and privacy screens: 1. Core: Phenolic impregnated Kraft papers. To ensure panel quality and consistency, panel must be at least 93 lbs./cubic foot to ensure full saturation of Kraft core. 2. Face sheet: Decorative papers impregnated with melamine resin and integrally compression molded with the core. A. Colors: As indicated on drawings. B. Finish: Quartz. B. Stainless Steel: ASTM A167, Type 304. C. Concealed Fasteners and Leveling Devices: Zinc or cadmium coated steel. 2.03 FABRICATION A. Panels and Urinal Screens: Flush, formed of 1/2" thick Trespa solid phenolic panels. Height and width as indicated in drawings.

B. Pilasters and Doors: Flush, formed of 3/4" thick Trespa solid phenolic panels. 1. Door Dimensions: Unless otherwise indicated, furnish 24" wide in-swinging doors for standard toilet compartments, 36" wide clear opening outswinging doors when located at the end, and 36" wide clear opening outswinging doors when located at the side for stalls equipped for use by the physically disabled. [No-Sightline doors and pilasters provided with 1/2" by 3/8" rabbit as indicated on drawings to create a No-Sightline design.] 2. Anchorage Devices: Provide galvanized steel anchorage devices, complete and threaded rods, washers, and leveling adjustment nuts at pilasters, to permit connection to [structural support above finished ceiling] [Floor slab]. Furnish devices, which are designed to support pilasters from structure without transmitting load to [floor fill] [ceiling finish]. 3. Overhead Bracing: Provide anti-grip, decorative, heavy duty, extruded aluminum head rail with clear anodized finish. 2.04 COMMERCIAL DUTY HARDWARE & FITTINGS A. Materials: Type 304 stainless steel, unless otherwise specified. Aluminum or die cast zinc alloy castings will not be acceptable. B. Stirrup Brackets: Provide 3 U-brackets for attaching each panel to pilaster and 3 double-eared brackets for attaching panels and urinal screen to the wall. Fasten brackets with stainless steel, one-way shouldered through-bolts and barrel nuts. C. Hinges: Heavy duty, surface mounted, self-closing type, adjustable to hold door open at any angle up to 90 degrees. D. Latch and Keeper: Surface mounted latch unit designed for physically disabled accessibility, with combination rubber-faced door strike and keeper. E. Coat Hook: Combination hook and rubber-tipped bumper, sized to prevent door from hitting mounted accessories. F. Door Pull: Manufacturer's standard for out-swinging doors. 2.05 INSTITUTIONAL DUTY HARDWARE AND FITTINGS A. Materials: Type 304 stainless steel with a No. 4 brushed satin finish, unless otherwise specified. Die cast zinc alloy castings will not be acceptable. B. Brackets: Provide a continuous U-shaped bracket for attaching each panel to pilaster and two continuous angles for attaching panels and urinal screens to the wall. Angles and brackets shall not be lighter than 18 gauge stainless steel. C. Hinges: Model No. 780-057 "Roton" geared, continuous, surface mounted type of extruded aluminum with a clear anodized finish equipped for easy removal to

provide emergency access for the physically disabled. D. Latch and Keeper: Surface mounted latch unit designed for physically disabled accessibility, with combination rubber-faced door strike and keeper. E. Coat Hook: Combination hook and rubber-tipped bumper, sized to prevent door from hitting mounted accessories. F. Door Pull: Manufacturer's standard for out-swinging doors. 2.06 SOURCE QUALITY CONTROL A. Fire resistance: Fabricate compartments from panels, which have a fire classification and label from Underwriters Laboratories, Inc. as follows: 1. 3/4" (19mm) flame spread: 25, smoke developed: 70; 2. 1/2" (13mm) flame spread: 30, smoke developed: 85. B. Consistency: 1. Panels to have uniform thickness (+0.03 ). 2. Panels to have uniform flatness (maximum difference of 0.03 ) for 10 span. 3. Panels to be U.L. registered and labeled for quality consistency. C. Modulus of Elasticity: 1.5 Million PSI minimum. D. Shear strength: 2,000 PSI minimum. E. Compressive strength: 24,000 PSI minimum. F. Water absorption: 3% maximum. G. Screw pull-out strength minimums chart (lbs.): Screw depth: #6 #8 #10 #12 1/4 5/16 3/8 7/16 1/2 1/2 panels: 250 300 340 390 450 560 680 790 900 3/4 panels: 510 590 680 850 1,000 1,200 1,400 H. Chemical resistance: Panels to meet or exceed Scientific Equipment Furniture Association s (S.E.F.A.) list of 49 standard chemicals. PART 3 - EXECUTION 3.01 EXAMINATION A. Before covering wall and ceiling framing with finish materials, examine framing to ensure that backing plates and structural framing have been installed in such position as to receive all attachment screws.

B. Verify spacing of plumbing fixtures to ensure compatibility with installation of compartments. C. Do not start the work of this section until all deficiencies have been corrected. 3.02 INSTALLATION A. General: Install toilet compartments and urinal screens as shown on the shop drawings and in accordance with Manufacturer s specifications and printed installation instructions. Install toilet compartments and doors in a rigid and substantial manner, straight and plumb, with horizontal lines level. B. Pilasters: Secure pilasters to supporting members and level, plumb and tighten the installation with leveling nuts and washers. C. Panels and Urinal Screens: Secure panels and doors to pilasters so the exterior faces are flush. Provide clearances of not more than 1/2 inch between pilasters and panels, and 1 inch between panels and walls. Secure panels and urinal screens to walls with 2 stirrup brackets located near the top and bottom of each panel, or one continuous bracket from top to bottom. At light gauged steel framed walls, fasten brackets with toggle or molly bolts into metal studs or backing plates fastened directly to the studs. At wood framed walls, fasten brackets with wood screws into wood studs or blocking fastened directly to the studs. At concrete or masonry walls, fasten brackets with screws and expansion anchors. 3.03 ADJUSTING AND CLEANING A. Hardware Adjustment: After installation, carefully adjust hardware for proper operation. Set hinges on in-swinging doors to hold open approximately 30 degrees from the closed position when unlatched. Set hinges on out-swinging doors to return to the fully closed position. Adjust doors so that doors are level with the pilasters when the doors are in the closed position. B. Cleaning: Clean compartments at completion and leave free of imperfections. END OF SECTION