A This Section includes stock, manufactured toilet compartments.
|
|
- Cornelius Gibson
- 6 years ago
- Views:
Transcription
1 SECTION TOILET COMPARTMENTS PART 1 -GENERAL 1.1 SUMMARY A This Section includes stock, manufactured toilet compartments. B. Types of toilet compartments include: 1. Solid plastic, homogenous color. C. Styles of toilet compartments include: 1. Floor-anchored, overhead-braced. D. Supports for attaching compartments to overhead structural system are specified in a Division 5 Section. E. Toilet accessories, such as toilet paper holders, grab bars, and purse shelves, are specified in another Division 10 Section. 1.2 SUBMITTALS A General: Submit the following in accordance with Conditions of Contract and Division 1 Specification Sections. B. Product data for materials, fabrication, and installation including catalog cuts of anchors, hardware, fastenings, and accessories. C. Shop drawings for fabrication and erection of toilet compartment assemblies not fully described by product drawings, templates, and instructions for installation of anchorage devices built into other work. D. Samples of full range of colors for each type of unit required. Submit 6-inch-square samples of each color and finish on same substrate to be used in work, for color verification after selections have been made. 1.3 QUALITY ASSURANCE A Field Measurements: Take field measurements prior to preparation of shop drawings and fabrication, where possible, to ensure proper fitting of work. However, allow for adjustments where taking of field measurements before fabrication might delay work. B. Coordination: Furnish inserts and anchorages which must be built into other work for installation of toilet compartments and related items. Coordinate delivery with other work to avoid delay. (CCC Lodge Restoration.0714) TOILET COMPARTMENTS
2 PART 2- PRODUCTS 2.1 MANUFACTURERS A Available Manufacturers: Subject to compliance with requirements, manufacturers offering products which may be incorporated in the Work include, but are not limited to, the following: B. Manufacturer: Subject to compliance with requirements, provide products by one of the following: 1. Solid Plastic - Polymer Resin: 2.2 MATERIALS a. Capitol Partitions, Inc. b. Sanatec Industries, Inc. c. Santana Products Co. d. Sanymetal Products Corp. A General: Provide materials which have been selected for surface flatness and smoothness. Exposed surfaces which exhibit pitting, seam marks, roller marks, stains, discolorations, telegraphing of core material, or other imperfections on finished units are not acceptable. B. Solid Plastic: High density, solid polymer resin with homogenous color throughout. Provide material not less than 1 inch thick with seamless construction with edges eased. C. Pilaster Shoes and Caps: ASTM A 167, Type 302/304 stainless steel, not less than 3 inches high, inch thick (20 gage), finished to match hardware. D. Stirrup Brackets: Manufacturer's standard design for attaching panels to walls and pilasters, either chromium-plated nonferrous cast alloy ("Zamac") or anodized aluminum. E. Hardware and Accessories: Manufacturer's standard design, heavy duty operating hardware and accessories of chromium-plated, nonferrous cast alloy ("Zamac"). F. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel, chromium-plated steel, or brass, finished to match hardware, with theft-resistanttype heads and nuts. For concealed anchors, use hot-dip galvanized, cadmium-plated, or other rust-resistant protective-coated steel. 2.3 FABRICATION: A General: Furnish standard doors, panels, screens, and pilasters fabricated for compartment system. Furnish units with cutouts, drilled holes, and internal reinforcement to receive partition-mounted hardware, accessories, and grab bars, as indicated. (CCC Lodge Restoration.0714) TOILET COMPARTMENTS
3 B. Door Dimensions: Unless otherwise indicated, furnish 24-inch-wide in-swinging doors for ordinary toilet stalls and 32-inch-wide (clear opening) out-swinging doors for stalls equipped for use by handicapped. C. Floor-and-Ceiling Anchored Compartments: Furnish galvanized steel anchorage devices complete with floor and ceiling closures. D. Floor-and-Ceiling Anchored Screens: Furnish pilasters and panels not less than 1 inch thick and of same construction and finish as toilet compartments. Furnish galvanized steel anchorage devices complete with threaded rods, lock washers, and leveling adjustment nuts at pilasters to permit structural connection to floor. Furnish shoe at pilaster to conceal anchorage. E. Hardware: Furnish hardware for each compartment to comply with ANSI A for handicapped accessibility and as follows: 2.4 FINISH 1. Hinges: Cutout inset type, adjustable to hold door open at any angle up to 90 degrees. Provide gravity type, spring-action cam type, or concealed torsion rod type to suit manufacturer's standards. 2. Latch and Keeper: Recessed latch unit, designed for emergency access, with combination rubber-faced door strike and keeper. 3. Coat Hook: Manufacturer's standard unit, combination hook and rubber-tipped bumper, sized to prevent door hitting mounted accessories. 4. Door Pull: Manufacturer's standard unit for out-swinging doors. Provide pulls on both faces of handicapped compartment doors. A. Color: One of manufacturer's standard colors in each room, as indicated or, if not indicated, as selected by Architect. PART 3 - EXECUTION 3.1 INSTALLATION A. General: Comply with manufacturer's recommended procedures and installation sequence. Install compartment units rigid, straight, plumb, and level. Provide clearances of not more than 1/2 inch between pilasters and panels, and not more than 1 inch between panels and walls. Secure panels to walls with not less than two stirrup brackets attached near top and bottom of panel. Locate wall brackets so that holes for wall anchorages occur in masonry or tile joints. Secure panels to pilasters with not less than two stirrup brackets located to align with stirrup brackets at wall. Secure panels in position with manufacturer's recommended anchoring devices. B. Floor-Supported Compartments: Set pilaster units with anchorages having not less than 2 inches penetration into structural floor, unless otherwise recommended by partition manufacturer. Level, plumb, and tighten installation with devices furnished. Hang doors (CCC Lodge Restoration.0714) TOILET COMPARTMENTS
4 and adjust so that tops of doors are level with tops of pilasters when doors are in closed position. C. Screens: Attach with anchoring devices as recommended by manufacturer to suit supporting structure. Set units to provide support and to resist lateral impact. 3.2 ADJUST AND CLEAN A Hardware Adjustment: Adjust and lubricate hardware for proper operation. Set hinges on in-swinging doors to hold open approximately 30 degrees from closed position when unlatched. Set hinges on out-swinging doors (and entrance swing doors) to return to fully closed position. B. Clean exposed surfaces of partition systems using materials and methods recommended by manufacturer, and provide protection as necessary to prevent damage during remainder of construction period. END OF SECTION (CCC Lodge Restoration.0714) TOILET COMPARTMENTS
5 SECTION TOILET ACCESSORIES PART 1 -GENERAL 1.1 DESCRIPTION OF WORK: A. Extent of each type of toilet accessory is shown on drawings and schedules. B. Types of toilet accessories required include the following: 1. Grab Bars 2. Toilet Tissue Dispensers 3. Shower Curtain Rods 4. Shower Curtains and Hooks 5. Towel Bars 6. Baby Changing Station 7. Warm-Air Dryers C. Mirror Units are specified elsewhere in Division QUALITY ASSURANCE: A. Inserts and Anchorages: Furnish inserts and anchoring devices which must be set in concrete or built into masonry; coordinate delivery with other work to avoid delay. B. Accessory Locations: Coordinate accessory locations with other work to avoid interference and to assure proper operation and service of accessory units. C. Products: Provide products of same manufacturer for each type of accessory unit and for units exposed in same areas, unless otherwise acceptable to Architect. D. Manufacturer: Provide each type of toilet accessory required as manufactured by one of the following: 1. A & J Washroom Accessories 2. American Specialties, Inc. 3. Bobrick Washroom Equipment, Inc. 4. Bradley Corporation 5. General Accessory Manufacturing Co. (GAMCO) 1.3 SUBMITTALS: A. Product Data: Submit manufacturer's technical data, cut sheet and installation instructions for each toilet accessory. (CCC Lodge Restoration.0714) TOILET ACCESSORIES
6 PART 2- PRODUCTS 2.1 MATERIALS: A Stainless Steel: ASTM A 666, Type 304 with polished No. 4 finish, 22 gage minimum, unless otherwise indicated. B. Sheet Steel: ASTM A 1008/ A 1008M, Designation CS (cold rolled, commercial steel). Surface preparation and metal pretreatment as required for applied finish. C. Baked Enamel Finish: Factory-applied, gloss white, baked acrylic enamel coating. D. Mirror Glass: ASTM C 1503, Mirror Glazing Quality, clear glass mirrors, nominal 6.0 mm thick. E. Fasteners: Screws, bolts, and other devices of same material as accessory unit or of galvanized steel where concealed. 2.2 FABRICATION: A General: Stamped names or labels on exposed faces of toilet accessory units are not permitted, except where otherwise indicated. Wherever locks are required for a particular type of toilet accessory, provide same keying throughout project. Furnish two keys for each lock. B. Surface-Mounted Toilet Accessories, General: Except where otherwise indicated, fabricate units with tight seams and joints, exposed edges rolled. Hang doors or access panels with continuous piano hinge or minimum of two 1-1/2" pin hinges of same metal as unit cabinet. Provide concealed anchorage wherever possible. C. Recessed Toilet Accessories, General: Except where otherwise indicated, fabricate units of all welded construction, without mitered corners. Hang doors or access panels with fulllength stainless steel piano hinge. Provide anchorage which is fully concealed when unit is closed. D. Grab Bars: 1, Stainless Steel Type: Provide grab bars with wall thickness not less than 18 gage and conforming to the Americans with Disabilities Act (ADA) requirements and as follows: a. Mounting: Concealed, manufacturer's standard flanges and anchorages. b. Gripping Surfaces: Smooth, polished finish. c. Size: Outside diameter of 1 1/4". d. Length: Per plans. e. Equal to #125-C by GAMCO. (CCC Lodge Restoration.0714) TOILET ACCESSORIES
7 E. Toilet Tissue Dispensers: 1. Single-Roll Type: Size to accommodate core tissue to 5" diameter, with metal paper roller equipped with heavy-duty internal spring and finished to match base unit. Unit shall be equal to style #761 by GAMCO. F. Shower Curtain Rods, Heavy Duty: 1 1 // o.d., 18 gage stainless steel, satin finish; furnish 3" o.d. minimum 20 gage stainless steel flanges with satin finish, designed for exposed fasteners. Rod shall be equal to style #125 SR by GAMCO. G. Anti-Bacterial Shower Curtain: Width, per opening x 72" high,.008" thick Nylon-reinforced anti-bacterial vinyl fabric with hemmed edges. Fabric to be flameproof, stain resistant and self-deodorizing, with stainless steel grommets on 6" centers through top hem. Architect to select color from manufactureros standard colors. Curtain equal to #1 00 SC - 42 x 72 bygamco. H. Shower Curtain Hooks: Stainless steel spring wire curtain hooks with snap fasteners, sized to accommodate curtain rod size specified above. Hooks equal to #1 00 CHSS by GAM CO. I. Towel Bars: 1. Stainless Steel type to match other toilet accessories. Length, 24". Bar to be equal to #751 by GAMCO. J. Double Robe Hook: Heavy-duty finished stainless steel double prong robe hook; rectangular wall bracket with backplate for concealed mounting. Equal to #B7672 by Bob rick. K. Baby Changing Station: 1, Horizontal Baby Changing: Stainless steel wall mounted horizontal design of 16 gage, 304 stainless steel with reinforced, full-length steel on steel hinges. Operation is a hidden pneumatic gas spring mechanism for safe open/close motion integral, built-in liner dispenser for use with 3-ply chemical free biodegradable 13" x 18" sanitary liners. Equal to Koala Kare Products. Model No. KB110-SSWM. L. Warm-Air Dryers 1. Source Limitations: Obtain warm-air dryers from single source from single manufacturer. 2. Warm-Air Dryer a. Description: Standard-speed, warm-air hand dryer. b. Mounting: Surface mounted. c. Operation: Electronic-sensor. 1. Operation Time: 30 seconds. (CCC Lodge Restoration.0714) TOILET ACCESSORIES
8 PART 3- EXECUTION 3.1 INSPECTION: d. Cover Material and Finish: Steel, white enamel finish. e. Electrical Requirements: 115 V, 13 A, 1500 W. A. Installer must examine substrates, previously installed inserts and anchorages necessary to mounting of toilet accessories, and other conditions under which installation is to occur, and must notify Contractor in writing of conditions detrimental to proper and timely completion of work. do not proceed with work until unsatisfactory conditions have been corrected in manner acceptable to Installer. 3.2 INSTALLATION: A. Install toilet accessory units in accordance with manufacturer's instructions, using fasteners which are appropriate to substrate and recommended by manufacturer of unit Install units plumb and level, firmly anchored in locations indicated. 3.3 ADJUST AND CLEAN: A. Adjust toilet accessories for proper operation and verify that mechanisms function smoothly. B. Clean and polish all exposed surfaces after removing protective coatings. 3.4 TOILET ACCESSORIES SCHEDULE: At Room #003. provide: Grab bars as shown. Two toilet tissue dispenser. One baby changing station. One warm-air dryer. At Room #004. provide: Grab bars as shown. Three toilet tissue dispensers. One baby changing station. One warm-air dryer. At Room #008, provide: Grab bars as shown. One toilet tissue dispenser. One warm-air dryer. At Rooms #1 08 and #119 Rrovide: Grab bars as shown. One toilet tissue dispenser. One towel bar. (CCC Lodge Restoration.0714) TOILET ACCESSORIES
9 One shower curtain rod. One shower curtain 42" wide x 72" high. One set shower curtain hooks. One double robe hook. At Room #11 0 provide: One toilet tissue dispenser. One towel bar. One shower curtain rod. One shower curtain 42" wide x 72" high. One set shower curtain hooks. One double robe hook. At Room #112 by restroom at vanity provide: One towel bar. At Rooms #206. #207 and #213 provide: One toilet tissue dispenser. One towel bar. One shower curtain rod. One shower curtain 60" wide x 72" high. One set shower curtain hooks. One double robe hook. END OF SECTION (CCC Lodge Restoration.0714) TOILET ACCESSORIES
10 THIS PAGE INTENTIONALLY LEFT BLANK
11 SECTION MIRROR UNITS PART 1 -GENERAL 1.1 DESCRIPTION OF WORK: A Extent of mirror units is indicated herein. B. Types of mirror units required include the following: 1. Stainless steel framed mirrors. C. Mirror glass for custom installations is specified in Division 8. D. Toilet accessories are specified elsewhere in Division QUALITY ASSURANCE: A General: Provide mirror units produced by single manufacturer for entire project. B. Manufacturer: Provide mirror units as manufactured by one of the following: 1. Accessory Specialties, Inc. 2. Bobrick 3. Bradley Corp. 4. Engineered Products Co. 5. General Accessory Manufacturing Co. 1.3 SUBMITTALS: A Product Data: Submit manufacturer's technical data, detail drawings, and installation instructions for mirror units. 1.4 SPECIFIED PRODUCT WARRANTY: A Provide manufacturer's written 5-year warranty against silver spoilage of mirrors, agreeing to replace any mirrors which develop visible defects within warranty period. PART 2- PRODUCTS 2.1 MATERIALS: A Mirror Glass: 1/4" thick, Type I, Class I, Quality q2, conforming to FS DD-G-451, with silvering, copper coating, and protective organic coating complying with FS DD-M B. Stainless Steel Framing: AISI Type 302/304, with polished No.4 finish. C. Galvanized Steel Mounting Devices: ASTM A 386, hot-dip galvanized after fabrication. (CCC Lodge Restoration.0714) MIRROR UNITS
12 2.2 FABRICATION: A General: 1. Edge Protection: Fabricate frames for glass mirrors to accommodate wood, felt, plastic, or other glass edge protection material. 2. Backing: Provide mirror backing and support system which will permit rigid, tamperproof glass installation and prevent accumulation of moisture, as follows: a. Air space backing provided by resilient pads or grommets attached to hanger assembly. 3. Hangers: Provide system of mounting mirror units which will permit rigid, tamperproof and theftproof installation, as follows: a. Heavy-duty wall brackets of galvanized steel, equipped with concealed locking devices requiring special tool to remove. 4. Stainless Steel Framed Mirrors: PART 3 -EXECUTION 3.1 INSTALLATION: a. Standard Type: Fabricate frame with channel shapes of not less than 20 gage, with square corners carefully mitered to hairline joints and mechanically interlocked. A Secure mirrors to walls in tamperproof manner with special hangers, toggle bolts, or screws. Set units plumb, level, and square at locations indicted, in accordance with manufacturer's instructions for type of substrate involved. 3.2 ADJUST AND CLEAN: A Verify that adjustable tilting mirrors are properly installed and are operating smoothly. B. Clean exposed surfaces of mirror units in compliance with manufacturer's recommendations. 3.3 MIRROR UNIT SCHEDULE: END OF SECTION At Rooms #003 and #004 provide: Two (2) 24' wide x 36" high mirrors. At Rooms #008, #108, #116, #119, #206, #207, #213 and #112 by restroom at vanity provide: One (1) 24" wide by 36" high mirror. (CCC Lodge Restoration.0714) MIRROR UNITS
13 SECTION PORTABLE FIRE EXTINGUISHERS PART 1 -GENERAL 1.1 DESCRIPTION OF WORK: A Definition: "Portable fire extinguishers" includes units which can be hand-carried as opposed to those which are equipped with wheels or to fixed fire extinguishing systems, unless otherwise indicated. Type of products in this section include: 1. Fire extinguishers. 2. Accessories, including: 1. Fire extinguisher cabinets 1.2 QUALITY ASSURANCE: A Provide portable fire extinguishers and accessories by one manufacturer, unless otherwise acceptable to Architect. 1. Manufacturers offering products to comply with the requirements include the following: a. Ansullncorporated b. J.L. Industries c. Larsen's Manufacturing Company d. Watrous, Inc. B. UL-Listed Products: Provide new portable fire extinguishers which are UL-Iisted and bear UL "Listing Mark" for type, rating, and classification of extinguisher indicated. 1.3 SUBMITTALS: A Product Data: Submit manufacturer's technical data and installation instructions for all portable fire extinguishers required. For fire extinguisher cabinets include roughing-in dimensions, and details showing mounting methods, relationships to surrounding construction, door hardware, cabinet type and materials, trim style and door construction, style and materials. Where color selection by Architect is required, include color charts showing full range of manufacturer's standard colors and designs available. PART 2- PRODUCTS 2.1 FIRE EXTINGUISHERS: A General: Provide fire extinguishers for each extinguisher cabinet and other locations indicated, in colors and finishes selected by Architect from manufacturer's standard which comply with requirements of governing authorities. (CCC Lodge Restoration.0714) PORTABLE FIRE EXTINGUISHERS
14 1. Abbreviations indicated below to identify extinguisher types relate to UL classification and ratings system and not, necessarily, to type and amount of extinguishing materials contained in extinguisher. B. Multi-Purpose Dry Chemical Type (4A-60BC-FE): UL-rated 4A: 60:B: C, 10 lb. nominal capacity, in enameled steel container, for Class A, Class B and Class C fires. 2.2 FIRE EXTINGUISHER CABINETS: A. General: Provide fire extinguisher cabinets where indicated, of suitable size for housing fire extinguishers of types and capacities indicated. B. Construction: Manufacturer's standard enameled steel box, with trim, frame, door and hardware to suit cabinet type, trim style, and door style indicated. Weld all joints and grind smooth. Miter and weld perimeter door frames. C. Cabinet Type: Suitable for mounting conditions indicated, of the following types: 1. Recessed: Cabinet box (tub) fully recessed in walls of sufficient depth to suit style of trim indicated. D. Trim Style: Fabricate trim in one piece with corners mitered, welded and ground smooth. 1. Exposed Trim: One-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend). a. Flat Trim: Square edges with backbend of 1/4" to 5/16". 2. Trim Metal: Of same metal as door. E. Door Material and Construction: Manufacturer's standard door construction, of material indicated, coordinated with cabinet types and trim styles selected. F. Enameled Steel: Manufacturer's standard flush, hollow steel door construction with tubular stiles and rails. G. Door Style: Manufacturer's standard design as indicated below and on drawing: Full-Glass Panel: DSA glass unless otherwise indicated. H. Door Hardware: Provide manufacturer's standard door operating hardware of proper type for cabinet type, trim style, and door material and style indicated. Provide either lever handle with cam action latch, or door pull, exposed or concealed, and friction latch. Provide concealed or continuous type hinge permitting door to open 180 degrees. I. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as selected by Architect. (CCC Lodge Restoration.0714) PORTABLE FIRE EXTINGUISHERS
15 1. Identify fire extinguisher in fire-protection cabinet with the words "Fire Extinguisher." 2. Application Process: Pressure-sensitive vinyl letters. 3. Lettering Color: Black or as selected by the Architect. 4. Orientation: Vertical or as indicated by the Architect. 2.3 FACTORY FINISHING OF FIRE EXTINGUISHER CABINETS: A. General: Comply with NAAMM "Metal Finishes Manual" for finish designations and application recommendations except as otherwise indicated. Apply finishes in factory after products are assembled. Protect cabinets with plastic or paper covering, prior to shipment. B. Painted Finishes: C. Preparation: Clean surfaces of dirt, grease, and loose rust or mill scale. Apply finish to all surfaces of fabricated and assembled units, whether exposed or concealed when installed, except those surfaces specified to receive another finish. D. Factory-Primed Finish: Where painting after installation is indicated (not work of this section) apply manufacturer's standard primer suitable for paint coating specified in Division 9 section. PART 3 EXECUTION 3.1 INSTALLATION: A. Install items included in this section in locations and at mounting heights indicated, or if not indicated, at heights to comply with applicable regulations of governing authorities. 1. Prepare recesses in walls for fire extinguisher cabinets as required by type and size of cabinet and style trim and to comply with manufacturer's instructions. 2. Securely fasten mounting brackets and fire extinguisher cabinets to structure, square and plumb, to comply with manufacturer's instructions. 3. Where exact location of surface-mounted cabinets and bracket mounted fire extinguishers is not indicated, locate as directed by Architect. END OF SECTION (CCC Lodge Restoration.0714) PORTABLE FIRE EXTINGUISHERS
16 THIS PAGE INTENTIONALLY LEFT BLANK
e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.
TOILET COMPARTMENTS GENERAL INFORMATION 1.1 Unless otherwise directed by CU Facilities toilet compartments shall be floor-supported, and urinal screens shall be wall hung, with anchoring devices and accessories
More informationB. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.
SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationSECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.
SECTION 10155 TOILET COMPARTMENTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Plastic laminate partitions. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Concealed steel support members. B. Section
More information.1 Underwriters' Laboratories of Canada (ULC)..1 CAN/ULC-S102-M88(R2000), Surface Burning Characteristics of Building Materials and Assemblies.
Place D Orléans Transitway Section 10 11 35 1231 Place D Orléans Dr, Ottawa, ON. SLIDING DISPLAY BACKDROPS City of Ottawa Project No. CR008042 Page 1 of 2 1 GENERAL 1.01 REFERENCES.1 Underwriters' Laboratories
More informationB. Surface, partition and recessed mounted toilet and bath accessories indicated on the Drawings and Schedules.
SECTION 10 28 00 - TOILET ROOM ACCESSORIES PART 1: GENERAL 1.1 SUMMARY A. This section includes toilet and bath accessories in accordance with the Contract Documents. The work of this Section shall include
More informationPASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017
SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationA. Access doors and frames are part of an access door and frame allowance.
SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION IMPACT RESISTANT WALL PROTECTION
SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationB. Provide fire-rated access doors where indicated or scheduled.
SECTION 08305 ACCESS DOORS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationMODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS
MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes
More informationBradley Mills Stainless Steel Toilet Partitions
Bradley Mills Stainless Steel Toilet Partitions Bradley Mills Stainless Steel Partitions provide a low maintenance, and durable solution for toilet rooms. Bradley's Permaseal panel edge design locks moisture
More informationSECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS
SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationB. Polyethylene samples shall be submitted for Owner approval of color and quality.
Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and
More informationDivision 11 - Equipment Section 11401
PART 1 - GENERAL 1.1 GENERAL A. Division 1 General Requirements applies and becomes a part of this Section of the Specification as fully as if repeated herein. B. Items of equipment which are included
More informationBradley Bradmar Plastic Toilet Partitions
Bradley Bradmar Plastic Toilet Partitions Bradley Bradmar Plastic Partitions provide an economical, durable, and colorful solution for toilet rooms. Bradley's radiused panel edge design locks moisture
More informationSECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS
SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and
More informationSECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter
More informationSECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM
Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING
More informationSECTION DIRECTORIES
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 13 00 DIRECTORIES SPEC WRITER NOTES: 1. Delete // // if not applicable to project. Also delete any other item or paragraph not applicable in the section and
More informationArchitectural Specifications, Section Phenolic Lockers
Architectural Specifications, Section 10500 Phenolic Lockers Hollman, Inc., 1825 W. Walnut Hill Lane, Irving, TX 75038, (972) 815-4000, www.hollman.com 1.0 GENERAL 1.1 SECTION INCLUDES A. Phenolic Lockers.
More informationPRESTON HEALTH SERVICES ARCHITECT'S NO. 2700
SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:
SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications
More informationSECTION ALUMINUM STORM WINDOWS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationSECTION Summit Phenolic Lockers (Solid Phenolic Lockers)
SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with
More informationDIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS
DIVISION 10 SPECIALTIES SECTION 10 22 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationA. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.
SECTION 08462 - SWINGING AUTOMATIC ENTRANCE DOORS PART 1 - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division
More informationAcousti-Seal Encore Paired Panel (10650) Operable Partitions
Acousti-Seal Encore Paired Panel 10 22 26 (10650) Operable Partitions Optimal choice for straight-line openings that do not require multiple locations or offset storage Panels are hinged together in groups
More informationSECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.
SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-10 22 13 (August 2016) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-10 22 13 (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS References
More informationUniversity Apartments on Brooklyn PROJECT MANUAL
Section 122100 Horizontal Louver Blinds University Apartments on Brooklyn PART 1 - GENERAL 1.1 SECTION INCLUDES A. Horizontal slat louver blinds. B. Operating hardware. 1.2 RELATED SECTIONS A. Section
More informationSECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS
Page 1 of 6 SECTION 08 32 20 HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED BI-FOLD GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationCentral Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS
Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society
More informationSECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationBox Rail. Single Box Rail Bracket
HANGERS & RAILS Box Rail Accordion Door Hangers Max. Door Weight (SWL) 450 lbs Meets ANSI/BHMA A156.14, Grade 1. Rail is carefully formed to give an even tread to hanger wheels. Packaging: Bundled without
More informationSECTION ALUMINUM WINDOWS
SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required
More informationSECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING
7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes
More informationSECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs. 1.2 PERFORMANCE REQUIREMENTS A. Structural
More informationSECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.
SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,
More informationSECTION VISUAL DISPLAY BOARDS
SECTION 10115 - VISUAL DISPLAY BOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationGUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM
1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window
More informationSECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS
Page 1 of 9 SECTION 10 2238.13 LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED FOLDING GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationMASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.
SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated
More informationPIPE AND TUBE RAILINGS
SECTION 05521 - PIPE AND TUBE RAILINGS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationA. This Section includes the following: B. Related Sections: The following Sections contain requirements that relate to this Section:
SECTION 10 26 00 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawing and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationWHY SPECIFY KOALA: Koala s new KB200 Baby Changing Station has redefined the benefits of Family Friendly accommodation:
WHY SPECIFY KOALA: Koala s new KB200 Baby Changing Station has redefined the benefits of Family Friendly accommodation: COMPLIANCE: Exceeds ASTM, EN standards SAFETY: Less than 1% deflection PEACE OF MIND:
More informationHouston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College
SECTION 323113 - CHAIN LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationGUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM
1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY
More informationSECTION LOUVERS AND VENTS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 08 90 00 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS. References are in agreement with UMRL dated January 2018
USACE / NAVFAC / AFCEC / NASA UFGS-10 21 13 (August 2017) ---------------------------- Preparing Activity: USACE Superseding UFGS-10 21 13 (January 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS References
More informationSECTION GLASS BALUSTRADE RAILING SYSTEMS
SECTION 05 73 13 GLASS BALUSTRADE RAILING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions, Division 01 - General Requirements,
More informationSection SECTIONAL INSULATED STEEL DOORS
1 GENERAL 1.1 GENERAL REQUIREMENTS General Conditions and Division 01 apply to this section. 1.2 RELATED WORK Section 05500: Miscellaneous Metal Fabrication Section 07900: Joint Sealers Section 09900:
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
More informationSECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?
SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum
More informationSECTION ACOUSTICAL PANEL CEILINGS
SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationPH6000. Key Features
Phenolic Locker Series PH6000 Key Features ½ inch doors and end panels Durable, backed by a 20 year warranty. Ideal choice for wet-use areas including pools and recreation centers Graffiti resistant, permanent
More informationSPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders
Welcome to the O Keeffe s Guide Specification System prepared as an aid to specify in preparing written construction documents. For specification assistance with specific product applications, please contact
More informationSECTION EXPANSION CONTROL
SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationAluminum Component Pipe Railings
1 SECTION 05 7360 ALUMINUM COMPONENT PIPE RAILINGS PART 1 GENERAL 1.01 SECTION INCLUDES A. Aluminum component pipe handrails and railings. 1.02 RELATED REQUIREMENTS A. Section 02 9000: Landscaping: Installation
More informationALL-ALUMINUM DOOR & WINDOW FRAMING
ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum
More informationSOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES
PART 1 - GENERAL SECTION 122413 - ROLLER WINDOW SHADES 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION CHAIN-LINK FENCES AND GATES 02821/1
SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where
More informationAluminum-Framed Entrances and Storefronts
University of New Hampshire University of New Hampshire Scholars' Repository Division 08 Openings Chapter 5 Technical Construction and Renovation Standards 1-25-2013 084113 - Aluminum-Framed Entrances
More informationSECTION DECORATIVE METAL AND GLASS RAILING
SECTION 05 73 00 DECORATIVE METAL AND GLASS RAILING PART 1 GENERAL 1.1 SUMMARY A) This section includes both standard and custom handrails as shown in the contract drawings. B) These include aluminum,
More informationNorthpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017
SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System
SECTION 13096 RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13096-1 RF WELDED SYSTEM PART 1 GENERAL 1.1 SECTION
More information1.1 RELATED DOCUMENTS
Desert Academy Phase 2B Mathey and Associates Specification - Section 08 35 13 Accordion Folding Doors PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract including
More informationSeries - 1
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum
More informationSPECIFICATION GUIDE SLIDING CLOSET DOOR PART 1 - PRODUCT
SPECIFICATION GUIDE SLIDING CLOSET DOOR INTERIOR SLIDING GLASS DOOR PART 1 - PRODUCT 1.1 MANUFACTURER A. COXUSA 4755 E. Zinfandel Court, Suite D Ontario, California 91761 909.545.8900 eddie.coxusa@icloud.com
More informationSECTION HVAC GRAVITY VENTILATORS
SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationPage 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES
2016-03-24 Page 1 SECTION 08360 SECTIONAL OVERHEAD DOORS DESCRIPTION MODEL 900 PRODUCT FEATURES Sectional steel overhead doors, industrial grade heavy duty construction. BASIC USES / RELATED USES Sectional
More informationSECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.
SECTION 08520 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 07200 - Joint Sealers. 2. 08800 - Glass and Glazing. 1.02 REFERENCES A. AAMA/NWWDA 101-97 Voluntary Specifications for
More informationA. Submit the following in addition to the standard requirements.
SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,
More informationSECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS
SECTION 08211 VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division I Specification
More informationELLISON BRONZE SECTION EXTRUDED ALUMINUM BALANCED DOOR ENTRANCES
ELLISON BRONZE SECTION 08 42 36 Section C EXTRUDED ALUMINUM BALANCED DOOR ENTRANCES Display hidden notes to specifier by using Tools / Options / View / Hidden Text PART 1 GENERAL 1.01 DESCRIPTION A. Work
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'
More informationDBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE
SECTION 112429.18 - HORIZONTAL FALL PROTECTION - OVERHEAD CABLE PART 1 - GENERAL 1.1 SECTION INCLUDES A. Provide overhead horizontal cable fall protection system, including end anchors, energy absorbers,
More informationWall Louvers (10200)
Wall Louvers 08 90 00 (10200) PART 1 GENERAL SECTION INCLUDES A. Fixed, extruded-aluminum horizontal storm resistant louver RELATED SECTIONS A. Section 05120 - Structural Steel: Supports for penthouses.
More informationSECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:
SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.
More informationSECTION COLD-FORMED METAL FRAMING
SECTION 05400 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide all cold formed metal framing. B. This Section includes:
More informationSECTION FLOOR MATS AND FRAMES
Section 12484 Floor Mats and Frames SECTION 12484 - FLOOR MATS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS PRODUCT OVERVIEW: Top Supported Center Stack Paired Panels Manually Operated Maximum Opening Height: 10'2 [3.1] Maximum Opening Width: Unlimited Select for Special Needs: Use
More informationSUGGESTED SPECIFICATION SECTION ENTRANCE FLOOR MATS AND FRAMES
Note: After downloading this spec, the Specifier must choose the correct Finish, Insert and Frame options and delete all other options to produce an accurate specification. GRIDLINE (G6) SUGGESTED SPECIFICATION
More informationA. Types of lightgauge metal framing units include the following: 1. C-shaped structural steel studs Uniform Building Code.
SECTION 05400 COLD-FORMED METAL FRAMING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification
More informationSECTION GYPSUM BOARD ASSEMBLIES
SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.
More informationSECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS
SECTION 055213- PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 12 2113 - LOUVER BLINDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationArchitectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION
Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division
More informationModel 4010 Individual Panels / Curve & Diverter
Model 4010 Individual Panels / Curve & Diverter Introduction: The following three (3) part specification offers the Standard and Optional features for the Model 4010 Curve & Diverter Operable Wall System.
More informationSECTION BASIC ELECTRICAL MATERIALS AND METHODS
SECTION 26 05 05 BASIC ELECTRICAL MATERIALS PART 1 - GENERAL 1.1 SUMMARY A. Section includes the limited scope construction materials and methods for application with electrical installations as follows:
More informationSECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)
SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationDIVISION OF PITTCON CUSTOM CORPORATION. Series Plastic Laminate or Veneer clad Column Covers CC-7
DIVISION OF PITTCON CUSTOM CORPORATION Series 8500 Plastic Laminate or Veneer clad s CC-7 Series 8500-Details Quarter Round (Wall Mount) Half Round (Wall Mount) Three-Quarter & Partial Column Covers Post
More informationAmerican Metal Specialties, Inc.
American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best
More informationSECTION GYPSUM BOARD
SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable
More informationA. Product Data shall be provided for each type of product indicated.
32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical
More informationSECTION EXTERIOR GRILLS AND SCREENS
SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,
More informationSECTION ALUMINUM RAILINGS
SECTION 05522 ALUMINUM RAILINGS PART 1 GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Aluminum pipe and tube railings. B. Related Sections include the following: 1. Division 5 Section "Ornamental