LANDFILL SITE [CLOSED 00] PLAN.... 5. TITLE LIST OF DRAWINGS EXISTING PROCESS DIAGRAM PROPOSED PROCESS DIAGRAM EXISTING EQUIPMENT LAYOUT PLAN PROPOSED EQUIPMENT LAYOUT PLAN ELEVATION D AND DETAILS
TREATMENT ISOLATION VALVE FLOAT VALVE MANIFOLD TO PRESSURE REDUCING VALVE 5Ø PVC 8Ø PVC FILTERED WATER. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES BASKET STRAINER. ITEMS TO BE REMOVED SHALL BE TURNED OVER TO THE. PRESSURE GAUGE 5Ø 5Ø UNION 8Ø PVC INCREASER/DECREASER WATER SUPPLY DRAIN LINE FEATURE FILTER 8Ø PVC TO FOUNTAIN FILTER ITEMS TO BE REMOVED PVC 8Ø PVC Ø HOSE Ø HOSE PRIMING CONNECTIONS 8Ø PVC BACKWASH DISCHARGE Ø MAKE-UP WATER BACK FLOW PREVENTER FLOAT VALVE - COMPARTMENT CONCRETE TANK 000 GALLON WATERMAIN SANITARY SEWER 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER - JACUZZI MODEL -MAG-U-S, HP 5 GPM @ 55 FT TDH PAC-FAB TAGELUS SAND FILTER MODEL TA0 CHLORINE DISPENSER PENTAIR RAINBOW LIFEGARD MODEL HC-0 5 CHLORINE ANALYZER FEATURE - JACUZZI MODEL 5VMB-T5.5HP 00 GPM @ 0FT TDH PORTABLE TESTER (TAYLOR POOL WATER TEST KIT), APOLLO MODEL RPA, mmø 8 MANIFOLD TO N/A MARCH 0-0- March, 0 0--.dwg
/ / / / GENERATER TREATMENT 00Ø ST. STL 00Ø ST. STL 5Ø PH ORP 5Ø PVC MANIFOLD TO / / / / FLANGED CONNECTION OR TRANSITION COUPLING (TYP. x) / / STARTER (EXISTING) DRAIN DRAIN 5Ø 5Ø Ø PRIMING LINE / S Ø / / S 5Ø PVC FILTERED WATER BACK FLOW PREVENTER 5Ø 5Ø PVC FM 5Ø CLEAR PVC SIGHT TUBE 500mm LONG. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER REMOVED - COMPARTMENT CONCRETE TANK 000 GALLON WATERMAIN SANITARY SEWER CHLORINE DISPENSER ISOLATION VALVE ARV AIR RELEASE VALVE WATER SUPPLY 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP, APOLLO MODEL RPA, mmø S ELECTRIC SOLENOID VALVE FM CHEMICAL FEED LINE MANIFOLD TO FLOAT VALVE BASKET STRAINER DRAIN LINE PRV PRESSURE RELIEF VALVE PRESSURE GAUGE / COMMUNICATION LINE PRESSURE REDUCING VALVE UNION NORMALLY CLOSED INCREASER/DECREASER SAMPLE VALVE mmø HOSE BIB CONNECTION MARCH 0-0- March, 0 0--.dwg
OUTSIDE B OUTSIDE WASH DIESEL A A TREATMENT FD FD. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES WATER HEATER MOUNTED ABOVE DOOR SEE NOTE & RELOCATE CORK BOARD RELOCATE SHELF. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW B ELECTRICAL EMERGENCY LIGHTING CABINETS ELECTRICAL BOXES. REMOVE FILTER, CABLES, CONDUIT, STARTER & ELECTRICAL BOXES. TERMINATE PER ELECTRICAL CODE.. ITEMS TO BE REMOVED SHALL BE TURNED OVER TO THE. 8. EX. CORK BOARD AND SHELF TO BE RELOCATED PER INSTRUCTIONS. SCALE: :5 GYM SCALE: :0 ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER - JACUZZI MODEL -MAG-U-S, HP 5 GPM @ 55 FT TDH EXISTING -TO REMAIN EX. INSULATED ROOF DRAIN OUTSIDE TO WALL HYDRANT INSIDE 00 50 50 BFP HEATER EX. INSULATED ROOF DRAIN 00 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP PAC-FAB TAGIELLIS SAND FILTER MODEL TA0 CHLORINE DISPENSER PENTAIR RAINBOW LIFEGARD MODEL HC-0 5 CHLORINE ANALYZER PORTABLE TESTER USED FEATURE - JACUZZI MODEL 5VMB-T5.5HP 00 GPM @ 0FT TDH EXISTING - TO BE REPLACED 8 N/A 0 MANIFOLD TO SCALE: :0 SCALE: :0 SCALE: :0 MARCH 0-0- March, 0 0--.dwg
OUTSIDE C WASH TREATMENT DIESEL OUTSIDE D FROM UV. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES ELECTRICAL PROVIDE UNI-STRUT SUPPORTS UNDER FRONT OF UV CONTROL PANEL & UNDER UV REACTOR ANCHORED TO THE FLOOR D FEATURE H-O-A SWITCH E-STOP MEDIA FILTERS (x) BACKWASH WATER FILTERED WATER TO UV. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW. UV SYSTEM HAS 00mm ( INCH) FLANGED CONNECTIONS.. ALL MAIN LINE ISOLATION VALVES 00mmØ OR LARGER TO BE FLANGED PVC BUTTERFLY VALVES WITH LEVER OPERATORS. 8. ALL MAIN LINE ISOLATION VALVES 5mmØ OR SMALLER TO BE TRUE UNION PVC BALL VALVES. C ELECTRICAL BOXES (REMOVE ELECTRICAL BOXES FOR FILTER ). CONTRACTOR SHALL ARRANGE AND PAY FOR ESA INSPECTION AND PROVIDE ESA CLEARANCE CERTIFICATION TO PRIOR TO SUBSTANTIAL PERFORMANCE. GYM SCALE: :0 SCALE: :5 ITEM No. ITEM DESCRIPTION REMARKS - COMPARTMENT CONCRETE TANK, 000 GALLON FILTER CHLORINE DISPENSER MANIFOLD TO REMOVED 00 000 00 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP 00 000 500 CLEARANCE FOR UV MAINTENANCE SCALE: :0 0 SCALE: :0 MARCH 0-0- March, 0 0--.dwg
-00Ø 5S STAINLESS STEEL PIPES FLANGED TRANSITION CONNECTION (TYP. x) - PIPES NEW FILTER METER UV BYPASS VALVE EX. mmø MAKE-UP WATER LINE TO TANK 050 00 OWSJ TO EX. MANIFOLD TREATMENT FM 5xØ FROM NEW FILTERS NEW FILTER (TYP. x) SEE DETAIL FOR PIPE PENETRATION THROUGH WALL (TYP.) EX. 0 mm THICK CONCRETE PAD (TYP.) 50 00 50 50 EX. EXHAUST FAN EX. INTAKE DAMPER EX. DIESEL CLEARANCE BETWEEN WALL AND TO BE 800mm H x 00mm W 00 850 000 NEW UV CONTROL PANEL NEW UV REACTOR PROVIDE UNI-STRUT SUPPORTS UNDER FRONT OF UV CONTROL PANEL & UNDER UV REACTOR ANCHORED TO THE FLOOR CONCRETE FLOOR EX. CONCRETE BLOCK WALL (TYP.) 550 00 000 00 VENT HOLE AT TOP OF PIPE CUT BOTTOM END OF PIPE AT 5 ANGLE AND REMOVE SHARP EDGES TRANSDUCER TO BE ACCESSIBLE FROM ACCESS HATCH 00Ø CONTINUOUS SDR PVC PIPE C/W BLIND FLANGE TO SUIT INSTALLATION OF ULTRASONIC LEVEL TRANSDUCER 50 x 0 SS PIPE SUPPORTS FASTENED TO WALL WITH Ø SS CHEMICALLY BONDED ANCHORS @ MAX SPACING OF 000mm NOTES:. LOCATE PIPE AND TRANSDUCER NEAR HATCH FOR ACCESSIBLITY. PIPE SHALL HAVE NO HORIZONTAL SEAMS. ALL DIMENSIONS ARE SHOWN IN MILLIMETRES. MAIN PROCESS PIPING TO BE SCHEDULE 80 PVC. PLUMBING LINES TO BE TYPE L COPPER UNLESS. PROVIDE PIPE BANDING TAPE WITH FLOW. UV SYSTEM HAS 00mm ( INCH) FLANGED CONNECTIONS.. ALL MAIN LINE ISOLATION VALVES 00mmØ OR LARGER TO BE FLANGED PVC BUTTERFLY VALVES WITH LEVER OPERATORS. 8. ALL MAIN LINE ISOLATION VALVES 5mmØ OR SMALLER TO BE TRUE UNION PVC BALL VALVES.. CONTRACTOR SHALL ARRANGE AND PAY FOR ESA INSPECTION AND PROVIDE ESA CLEARANCE CERTIFICATION TO PRIOR TO SUBSTANTIAL PERFORMANCE. 00 50 00 8 8 SCALE: :0 5Ø AND 00Ø PIPE 0Ø PLASTIC COATED U-BOLT (EQUAL TO INTERNATIONAL FIG C) 50 x 50 x x 00 LONG ANGLE (TYP. x) Ø WASHER (TYP. x) Ø NUT (TYP. x) CONCRETE ANCHOR BOLT (TYP.) 50 x THICK PLATE WELDED TO ANGLES 5mm LONG SLOT FOR U-BOLTS C 00 L 00 0 x 0 x. SS HSS Ø SS ANCHOR BOLTS SS STRAP mm THICK x 50mm WIDE TO MATCH PIPE OD PIPE RUN 0 x 0 x ANGLE Ø SS HILTI HIT HY50 ANCHORS WITH SS RODS (TYP. x) SS BASE PLATE 50 x 50 x WELDED TO SS HSS TREATMENT/ INVERT EX. CONCRETE WALL STEEL PIPE SLEEVE w/ PUDDLE FLANGE NON-SHRINK GROUT FIRE STOP SEAL PIPE TOP CORD OF JOIST PIPE BOTTOM CORD OF JOIST HEAVY DUTY C-CLAMP (EQUAL TO ANVIL FIG. ) 5 8 " (mmø) THREADED ROD INSULATED CLEVIS HANGER (EQUAL TO ANVIL FIG. 0 ISS) 0// ISSUED FOR TENDER GAP 0/0/ ISSUED FOR APPROVAL GAP (FOR HORIZONTAL PIPE RUNS) (FOR VERTICAL PIPE RUNS) MAX SPACING.5m MAX SPACING.5m MAX SPACING.5m 0 SCALE: :0 MARCH 0-0- 5 March, 0 0--5.dwg