HIGH-RISE BUILDINGS September 20, 2010 PRAGUE Topic: Energy intensity of high-rise buildings in Prague and other European cities

Similar documents
Promoting Building Energy Efficiency in Germany

Buildings and Their. Carbon Footprints. 12 September San Jose, Costa Rica

SOLAR PHOTOVOLTAIC ENERGY

Stadtwerke Konstanz Customer Centre, Constance

Energy Efficient Buildings in Germany An Introduction

The Centre for Sustainable Building (ZUB) * A Case Study

Alternative Heating Sources

Efficiency house. Building description

CASE STUDIES - CENTRE FOR SUSTAINABLE BUILDING (ZUB) KASSEL, GERMANY

from June 5 th, 2016 until June 10 th, 2016 Business Travel Program of the German Chambers of Commerce

Energy Efficiency and Sustainability of Buildings in Planning Practice

The New Student Housing Building at The Mount St. Mary s s University Emmitsburg,, Maryland

PROPOSAL FOR A BUILDING ENERGY EFFICIENCY CERTIFICATE. H.-P. Leimer, Prof. Dr.-Ing.1,*

2030 Challenge & Zero Energy Buildings Ashley McGraw Architects, P.C.

FEBRUARY 22, GREEN BUILDING: Past, Present and Future

Energy Audit Summary Report Audit No GER08. DIN Building Berlin, Germany. Offices

Heat Pumps. and energy labelling regulations

GREEN H ALL m 2 CREATIVE HOUSE FOR PROGRESSIVE BUSINESS TOTAL AREA THREE BUILDINGS 480 SPACES

Chapter 18 Renewable Energy

CLIMATE. Eco-Building Cuts CO2 87%, Electricity 82%, Gas 87% and Water 72%: Eco-Building - Council House 2 (CH2) New Municipal Office Building

Natural Stone the balance looks right

New services for the comprehensive and ecological renovation of buildings

Greening the Blue Initiative in the VIC June 2018

Explain how energy is conserved within a closed system. Explain the law of conservation of energy.

Realising projects in the field of energy efficient building technology in Tunisia

EcoCommercial Building Program of Bayer Material Science

European Green Capital Award Frankfurt am Main s application Environmental indicator 12 Energy performance

PBW engineering office Wahlbuhl and Günther Ingenieure

The reasons for this approach are different. So

(PDF) FEASIBILITY STUDY ON ABSORPTION COOLING BASED

UBA builds answers Positive energy building in Dessau

Energy efficient office buildings

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Sustainable Architecture and Real Estate Development

LOW ENERGY CERTIFICATE - PROPOSAL FOR A BUILDING ENERGY EFFICIENCY CERTIFICATE

Building performance analysis for double skin residential buildings ABSTRACT BACKGROUND. Porooshat Akhgari

Principles of Green Architecture

Taking up the challenge of smart city refurbishment and energy efficiency in buildings. Astrid Severin Managing Director

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Chapter 10 - Energy Conservation

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

Heating, Cooling, Lighting: Sustainable Design Methods for Architects

Efficient and smart climate shell. refurbishment of residential buildings PART OF SMART SOLUTION 1: EFFICIENT AND SMART CLIMATE SHELL REFURBISHMENT

GEOTHERMAL SPACE COOLING

Press Release. Zero Energy Building for Seoul. Fraunhofer ISE Leads Interdisciplinary Team and Develops Energy Concept

For sustainable development.

Vivantes Klinikum Neukölln

The Renner Residence 2009 Mike and Elida Renner

TAP-YTL 2010: Sustainable Architecture & Urban Planning

Passive houses for the Northern climate

Methodological recommendations for the coowners of apartment buildings : elaboration of energy-efficient projects

Sustainable building in Germany - Government policies and new market opportunities

Energy efficiency of cooling systems: Optimization through precise energy monitoring

Building Certification 2.0 The German Sustainable Building Certification System in Practice

The German Sustainable Building Certification System DGNB Best Practice Examples from Thailand. Dr.-Ing. Robert Himmler Bangkok, Thailand

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

Ventilation in residential buildings: A comparison of different calculation methodologies in the context of the EPBD

COMPARISON OF TWO PASSIVE HOUSE SCHOOLS IN NORWAY AND GERMANY

Green home. How can energy saving potential best be activated? Perpectives Interview

ANALYSIS OF THE CONSERVATION AND ENERGY EFFICIENCY TAX PROVISIONS IN THE ENERGY POLICY ACT OF 2005

Insulated Concrete Forms as Thermal Envelope Used for the Romanian Passive Office Building in Bragadiru - Ilfov

Thermally Active Building Systems. Heating and cooling for offices and commercial buildings, cost- and energy-efficient

Effects of the use of DIN on the energetic assessment of residential buildings reflection on the calculation

GEIGER Impulse. Energy is a luxury good. Automation: a considerable potential for higher energy savings. New products. Newsletter worldwide 01/2014

Final Deliverable Report on Labelling possibilities investigation

Trane Water-Source Variable Refrigerant Flow

Low energy co-office building BMEEPTCEP01

POLYCITY Innovation Energy and environmental concepts of the POLYCITY project in Cerdanyola del Vallès CONCERTO POLYCITY

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

WINDOW AREA IN OFFICE BUILDINGS FROM THE VIEWPOINT OF ENERGY EFFICIENCY

12,690 M2 OF NEW, DIVISIBLE WAREHOUSE SPACE CLOSE TO THE A5 MOTORWAY AVAILABLE FROM Q4 2019

Remember... Kinetic energy is the energy an object has because of its motion.

"Innovation on High Ground"

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Introduction and utilizing of natural energy in Net ZEB practice

nzeb Germany - Strategy to improve energy efficiency in the German building sector and the leading role of public buildings Dr.-Ing.

SOLHOTAIR TECHNOLOGY. High efficiency solar technology for use in solar heating panels

ISES EuroSun Quality management as a key for efficient building performance

50 Solar Energy Estates in North Rhine-Westphalia

Renewable Energy Today

Solutions for Office Buildings. E f f i c i e n t H e at i n g, C o o l i n g, a n d P l u m b i n g

Plus Energy Architecture - Planning, Operation and Benchmarking , 4th Energy Efficiency Symposium, San Francisco

Zero Energy Home EDSGN 100 SECTION 005. Professor Wallace Catanach

The Role of Thermal Potential in Enhancing Energy Efficiency / Productivity

Energy Inventory Student Pages

Renovation for better energy efficiency

Renewable Energy for Heat

Carbon Neutral 60% 70% 80% 90% Today

Chapter 4 - Energy Conservation

Chapter 13 Achieving Energy Sustainability. Monday, February 26, 18

Klimaneutraler Campus Leuphana Universität Lüneburg - Energiekonzept und Umsetzung

SUSTAINABLE BUILDING MORE THAN ENERGY EFFICIENCY. Dr. Christine Lemaitre Deutsche Gesellschaft für Nachhaltiges Bauen DGNB e.v.

EXECUTIVE SUMMARY: Best practices and lists of technologies to refurbish buildings & Proposed packages of measures

Tohu: Chapiteau des Arts

Energy Efficient Building Envelope Kiev,

Institut für Luft- und Kältetechnik Dresden ggmbh Off-grid solar cooling systems with ice block generation for fisheries in Indonesia

2000 Antwerp, terraced house

Verified net Zero Energy Building with air source heat pumps for SME

Efficient utilization of energy sources

Transcription:

Title of paper: Experience with optimisation of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany Author: Plebs, Hubertus, Dipl.-Ing. Prokurist, Technical Director GGM Gesellschaft für Gebäude-Management mbh Neue Rothofstraße 12 D-60313 Frankfurt am Main Phone +49 69 77 01 97 32 Fax +49 69 77 01 97 99 E-mail: hubertus.plebs@ggm-re.de Internet: www.ggm-re.de

Dipl.-Ing. Hubertus Plebs companies: construction- and project manager (from 1984 to 2001) Bilfinger + Berger Bauaktiengesellschaft, Mannheim Frankfurter Aufbau AG, Frankfurt am Main Hines, Houston / Texas, Frankfurt am Main GGM Gesellschaft für Gebäude-Management mbh, Frankfurt am Main etc. Stadtwerke Frankfurt am Main (80,000m²) Hessischer Rundfunk, Frankfurt am Main (30,000 m²) Fürstenhof Leipzig, Leipzig (5 star hotel) MAIN TOWER; Frankfurt am Main etc. property management (since 2001) ca. 200 properties in Germany and Europe 2

GGM Gesellschaft für Gebäude-Management mbh Asset Management Property Management FM-Consulting etc. for 30 clients 130 properties 1.3 million m² rentable space currently in Europe and in Germany Brussels 3

1. Frankfurt am Main MAINHATTAN THE city of High-Rise buildings in Europe 4

International conference: Experience with optimisation of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany High-Rise Buildings managed by GGM MesseTurm MAIN TOWER Westhafen Kastor Grüneburgweg Eschersheimer Landstraße 5

2. Objectives Effective energy supply for High-Rise Buildings in Frankfurt am Main, Germany, under the aspects of guaranteed function of the building and its technical facilities as well as high tenants satisfaction. 6

3. Initial Situation Development, Promotion Great location Great exterior and interior architecture 7

Development, Promotion Openable windows Low energy costs with modern technology!!! Block-type thermal power stations Geothermical energy/ earth-cooling storage reservoir 8

4. Reality: start of operation / operation / service / maintenance Operational problems for example because of heating cooling low tenant satisfaction! electric supply etc. dirty heat exchanger facilities designed too big MAINWASSER refrigerating machines MAINWASSER refrigerating mussel covering machines facilities designed too small cooling supply and refrigeration groundwater flow in the earth-cooling storage reservoir 9

Problems with service charges low tenant satisfaction Service charges accounting Estimation as basis renting Service charges calculation after 1 st year in operation (3 to 4 years later) Service charges calculation after 2 nd year in operation (4 to 5 years later) Type of costs Eur/m²/month Eur/m²/month Difference Eur/m²/month Difference gross gross gross 1010 Grundsteuer / Property tax 0,51 0,73 1110 Wasser / Water 0,06 0,05-0,01 0,06 1120 Abwasser / Sewage 0,04 0,02-0,02 0,05 1140 Stromverbrauch Allgemein / Electricity consumption in general 0,33 0,31-0,02 0,41 Strom Mieter 1 ( Rechenzentrum) / Electricity tenant 1 (computer centre) 0,39 0,72 0,22 0,00 0,01 0,08 Strom Mieter 2 / Electricity tenant 2 0,00 0,03 Strom Mieter 3 / Electricity tenant 2 0,00 0,00 Strom Kälte restliche Mietbereiche / 0,00 0,04 0,04 0,06 Electricity, cooling energy remaining areas 0,06 Strom Kälte Mieter 1 (Rechenzentrum) / Electricity, cooling energy tenant 1 (computer centre) 0,38 0,30 Strom Kälte Mieter 1(Konferenzbereich) / Electricity, cooling energy tenant 1 (conference room) 0,00 0,28 Strom Kälte (restliche Bauteilaktivierung) / 0,09 0,09 0,00 0,11 Electricity, cooling energy (remaining thermo active building systems) 0,02 Strom Kälte Lupus alpha (Umluftkühlgeräte etc.) / Electricity, cooling energy Lupus alpha (air-cooling facilities etc.) 0,11 0,05 1170 Fernwärme / District Heating 0,32 0,44 0,12 0,49 0,17 Total energy costs 0,84 0,95 0,10 1,18 0,34 Optimisation of energy / Optimisation of energy costs 10

5. Optimisation of energy / Optimisation of energy costs What are the most expensive energy consumers? What can you do to reduce? Tenant o user behaviour o user demand Technical o heating o cooling o electric o air condition o elevaters Reduction / adjustment of demand Adjustment of technical facilities / modification of operational mode Reduction of maintenance costs Economic Use of inexpensive primary energies 11

Sensitising user behaviour / Analysing user demand General examples: 1 C warmer or colder?! Turning off the lights Motion detectors for underground car parks, staircases, etc. Closing the window when too warm / too cold Specific examples: One room with 250 m² as serverroom in computer center, no occupany cost saving around 10T /month 12

Adjustment of technical facilities / Modification of operational modes Exchange / supplement / (partial) shutdown of technical facilities Extension + exchange of refrigerating machines Partial shutdown of MAINWASSER refrigerating machines Shutdown of blocktype power stations Addition heat exchanger 13

Flexible energy use Operating with the currently most inexpensive primary energies 14

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany Control of operations / Control of energy consumption BMS-checking automatic control of operations Automatic control of energy consumption permanent control of energy consumption 15

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany Review, modifications What kind of criteria has to be followed with regard to architecture, material, concept of technical operation and.? Reducing energy losses Avoiding high heat load proper heat insulation high storage capacity of building materials low solar absorption coefficient Producing energy Using modern technical facilities using natural resources, for example sun, water, or soil 16

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany What kind of alternatives do we have to reduce energy costs by alteration of the operational concept? big points: using natural resources natural ventilation free cooling river-water cooling geothermal energy photovoltaics using rainwater etc. Renewable Energies 17

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany What kind of alternatives do we have to reduce energy costs by alternation of the operational concept? a lot of small points BIG POINTS for example: Innovative facade cooling system Innovative ceiling lights Innovative energy-saving electric bulbs Waterless pissoirs 18

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany What did the government do to save energy in Germany? Wärmeschutzverordnung 1977 2001 (heat insulation regulation) Energieausweis (energy performance certificate) Energieeinsparverordnung EnEV 2002 2009 (energy savings regulation) Objektive: Reducing energy consumption for heating and hot water for another 30 % as compared to EnEV 2007! LEED- und DGNB-Zertifizierungen (LEED- and DGNB Certificates) 19

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany How did architects, technical engineers and the industry react to these experiences regarding the operation of HIGH-RISE buildings? HIGH-RISE building 1970ies HIGH-RISE building 1980ies HIGH-RISE buildings 1990ies FBC Westend MesseTurm Trianon JAPAN TOWER 20

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany How did architects, technical engineers and the industry react to these experiences regarding the operation of HIGH-RISE buildings? HIGH-RISE buildings at the beginning of 2000 HIGH-RISE buildings 2010 MAIN TOWER Gallileo OpernTurm Tower 185 Deutsche Bank 21

International conference: Experience with optimisation i i of HIGH-RISE buildings energy supply in Frankfurt am Main, Germany 6. Conclusion What can you do to have a good energy conception? Ask GGM-FM-Consulting We have the experience and the knowledge THANKS for your attention 22