City of Long Beach Department of Development Services Building and Safety Bureau. Design Limitation for Wood Shear Walls

Similar documents
RoyOMartin TuffStrand and Windbrace 7/16 Performance Category OSB PR-N129 Martco, L.L.C. Revised November 6, 2017

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

Warmboard-S Radiant-Floor Heating Panels PR-V180 Warmboard, Inc. Revised February 19, 2018

Joint Evaluation Report

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

Joint Evaluation Report

Joint Evaluation Report

TECH BULLETIN. SIP No. Subject: Engineered Wood Lap Siding from Louisiana-Pacific. Date: August 2010 (Revised January 2015)

LP OSB Sheathing & Structural 1 Sheathing

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

2008 Special Design Provisions for Wind and Seismic

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

LP SmartSide Strand Substrate Treated-Engineered-Wood Lap & Panel Siding Louisiana-Pacific Corporation Revised December 2, 2016

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

PR-L274 Nordic Structures Revised April 16, 2017

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Stone and Masonry Veneer

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

Building Division Informational Handout

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

ALTERNATE DESIGN METHODOLOGY FOR UNREINFORCED MASONRY BUILDINGS

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

THE ENGINEERED WOOD ASSOCIATION

International Beams Revised June 15, 2018

FIGURE R502.2 FLOOR CONSTRUCTION

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

Originally Issued: 01/26/2010 Revised: 02/27/2017 Valid Through: 02/28/ Fasteners

Originally Issued: 01/26/2010 Revised: 01/05/2018 Valid Through: 02/28/ Design:

2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E.

Joint Evaluation Report

DECK PERMIT APPLICATION

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years.

GYPSUM BOARD AND PLASTER

Strong-Drive SDWS TIMBER Screw

CEMCO is Proud to Introduce an Innovative Steel Floor Joist System

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

TER No Attachment of Exterior Wall Coverings Through Kingspan Kooltherm Insulation Boards to Wood or Steel Wall Framing

TER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing

ICC-ES Evaluation Report Reissued November 2014 This report is subject to renewal November 2016

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

Technical Bulletin. CTIOA Technical Committee

TER No Attachment of Exterior Wall Coverings Through Kingspan GreenGuard Extruded Polystyrene (XPS) Sheathing to Wood or Steel Wall Framing

UDC Wall Bracing Provisions Emergency Rule effective date 4/1/2014. A How To guide for use of the new provisions

Benchmarking Seismic Base Shear to Historical Practice

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

Minimum required percentage of length of braced wall band on each storey 4

INTRODUCTION TO LATERAL DESIGN

SECTION Fiber Reinforced Stucco 1

WALL CONSTRUCTION CHAPTER 6

GA APPLICATION OF GYPSUM SHEATHING

WFCM 90 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 120 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

LEGACY REPORT REPORT HOLDER: ITW RAMSET EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Lateral load basics Code acceptance of Standard. Standard Overview 2008 Wind & Seismic Standard. Wind. Wind Load Path. IBC Section 1604.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

REPORT HOLDER: GYPSUM ASSOCIATION 6525 BELCREST ROAD #480 HYATTSVILLE, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: AFM CORPORATION

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

WFCM 110 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 100 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

ESR-1882 Reissued February 1, 2013 This report is subject to renewal February 1, 2014.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

Installation of Stucco Exterior Finish Over Wood Structural Panel Wall Sheathing

Thermo-Ply Red & Thermo-Ply Red AMG Structural Sheathing Canada Limit States Design. TER No

REPORT HOLDER: GYPSUM ASSOCIATION 962 WAYNE AVENUE, SUITE 620 SILVER SPRING, MARYLAND EVALUATION SUBJECT:

Wood Shear Wall Design Examples For Wind

ESR-1812 Reissued October 1, 2012 This report is subject to renewal November 1, 2013.

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015

Rich Denio, Supervising Structural Engineer Ron LaPlante, Supervising Structural Engineer

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

WALL CONSTRUCTION CHAPTER 6

Evaluation of Full-Scale House Testing Under Lateral Loading

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

SI-Strong Structural Insulation STYROFOAM SIS, SIS Plus Canada Limit States Design. TER No

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Trusted ICC ES APA TH STREET. Conformity! subject of the

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

2005 ERRATA to the Edition of. the Allowable Stress Design (ASD) Manual for Engineered Wood Construction (printed version dated M)

CHAPTER 5 FLOORS SECTION R501

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: AFM CORPORATION EVALUATION SUBJECT:

Code Compliance Research Report CCRR-0231

Transcription:

Department of Development Services Building and Safety Bureau Design Limitation for Wood Shear Walls Information Bulletin BU-004 Eff: 01-01-2008 Rev: 09-29-2011 The purpose of this Informational Bulletin is to alert designers of the specific modifications that the City of Long Beach, in cooperation with major jurisdictions within the Los Angeles region, has made to the 2010 California Building Code relating to the design of light-framed walls with shear panels. The lessons learned from the 1994 Northridge Earthquake have been refined with studies and tests that continued since the last code adoption cycle. The results of these studies and tests necessitate the adoption of further amendments to the structural requirement of the building code. Therefore, Sections 18.40.410 through 18.40.420 of the Long Beach Municipal Code place certain design and construction limits on structural wood panel shear walls and shear walls sheathed with other materials. These design limitation are intended to improve the quality of construction and performance of structures to assure that new buildings and additions or alterations to existing buildings are designed and constructed to resist the hazards of future earthquakes. Sections 18.40.410 through 18.40.420 of the Long Beach Municipal Code amended the allowable shear wall values as regulated in Section 2306.3 of the 2010 California Building Code. Pertinent sections of the Long Beach Municipal Code are repeated herein as follows: 18.40.410 CBC section 2306.3 amended Wood structural panel shear walls. Table 2306.3 (2) is added to Chapter 23 of the 2010 California Building Code and Section 2306.3 and Table 2306.3 of the 2010 Edition of the California Building Code are amended to read as follows: 2306.4.1. Wood structural panel shear walls. Wood structural panel shear walls shall be designed and constructed in accordance with AF&PA SDPWS. Wood structural panel shear walls are permitted to resist horizontal forces using the allowable shear capacities set forth in Table 2306.3(1). For structures assigned to Seismic Design Category D, E or F, the allowable shear capacities shall be set forth in Table 2306.3(2). The allowable shear capacities in Table 2306.3(1) are permitted to be increased 40 percent for wind design. Wood structural shear panel shear walls used to resist seismic forces in structures assigned to Seismic Design Category D, E or F shall not be less than 4 feet by 8 feet (1219 mm by 2438 mm), except at boundaries and at changes in framing. Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick and studs shall not be spaced at more than 16 inches on center. The maximum allowable shear value for three-ply plywood resisting seismic forces in structures assigned to Seismic Design Category D, E or F is 200 pounds per foot (2.92 kn/m). Nails shall be placed not less than 1/2 inch (12.7 mm) in from the panel edges and not less than 3/8 inch (9.5mm) from the edge of the connecting members for shear greater than 350 pounds per foot (5.11kN/m). Nails shall be placed not less than 3/8 inch (9.5 mm) from panel This information is available in an alternative format by request to Meg Rau at (562) 570-7744. For an electronic version of this document, visit our website at www.lbds.info 1 of 8

edges and not less than 1/4 inch (6.4 mm) from the edge of the connecting members for shears of 350 pounds per foot (5.11kN/m) or less. Wood structural panel shear walls fastened with staples shall not be used to resist seismic forces in structures assigned to Seismic Design Category D, E, or F. Exception: Staples may be used for wood structural panel shear walls when the allowable shear values are substantiated by cyclic testing and approved by the building official. Wood structural panel shear walls used to resist seismic forces in structures assigned to Seismic Design Category D, E or F shall be applied directly to the framing members. 18.40.420 CBC section 2306.7 amended Shear walls sheathed with other materials. Section 2306.7 of the 2010 California Building Code is amended to read as follows: 2306.6.7 Shear walls sheathed with other materials. Shear walls sheathed with Portland cement plaster, gypsum lath, gypsum sheathing or gypsum board shall be designed and constructed in accordance with AF & PA SDPWS. Shear walls sheathed with these materials are permitted to resist horizontal forces using the allowable shear capacities set forth in Table 2306.7. Shear walls sheathed with Portland cement plaster, gypsum lath, gypsum sheathing or gypsum board shall not be used to resist seismic forces in structures assigned to Seismic Design Category E or F. Shear walls sheathed with lath, plaster or gypsum board shall not be used below the top level in a multi-level building for structures assigned to Seismic Design Category D. 2 of 8

PANEL GRADE Structural I Sheathing NOMINAL PANEL THICKNESS (inch) TABLE 2306.3 (1) ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE a FOR WIND OR SEISMIC LOADING FASTENER PENETRATI ON IN FRAMING (inches) PANELS APPLIED DIRECT TO FRAMING NAIL (common or galvanized box) or staple size k b, h, I, j, l, m, n Fastener spacing at panel edges (inches) NAIL (common or galvanized 6 4 3 2 e box) or staple size k PANELS APPLIED OVER ½ OR 5/8 GYPSUM SHEATHING m Fastener spacing at panel edges (inches) 6 4 3 2 e 5/16 C or 1/4 C 230 d 360 d 460 d d 610 3/8 280 430 550 f 730 1 1 ½ 16 Gage 155 235 315 400 2 16 Gage 155 235 310 400 255 d 395 d 505 d d 280 670 7/16 430 550 f 730 1 1 ½ 16 Gage 170 260 345 440 2 16 Gage 155 235 310 400 280 430 550 730 280 430 550 f 730 15/32 1 1 ½ 16 Gage 185 280 375 475 2 16 Gage 155 235 300 400 1-1/2 3 x0.128 galvanized box) 340 510 665 f 870 - - - - - 1-1/4 6d (2"x0.113" common, 180 270 350 450 2 x0.099 galvanized box) 2 1/2 x 0.113 galvanized box) 180 270 350 450 1 1 1/1 16 Gage 145 220 295 375 2 16 Gage 110 165 220 285 Sheathing, plywood siding g except Group 5 Species 3/8 7/16 15/32 19/32 1-1/4 6d (2 x 0.113 common, 200 300 390 510 2 x 0.099 galvanized box) 2 1/2 x 0.113 galvanized box) 200 300 390 510 1 3/8 220 d 320 d 410 d d 530 260 380 490 f 640 1 1 ½ 16 Gage 140 210 280 360 2 16 Gage 140 210 280 360 240 d 350 d 450 d d 585 260 380 490 f 640 1 1 ½ 16 Gage 155 230 310 395 2 16 Gage 140 210 280 360 260 380 490 640 260 380 490 f 640 1-1/2 3 x0.128 galvanized box) 310 460 600 f 770 - - - - - 1 1 ½ 16 Gage 170 255 335 430 2 16 Gage 140 210 280 360 1-1/2 3 x0.128 galvanized box) 340 510 665 f 870 - - - - - 1 1 ¾ 16 Gage 185 280 375 475 - - - - - 5/16 C 1-1/4 6d (2 x0.099") 140 210 275 360 8d (2 ½ x0.113 ) 140 210 275 360 3/8 C 8d (2½"x0.113") 160 240 310 410 10d (3 x0.128 ) 160 240 310 f 410 For SI: 1 inch = 25.4 mm, 1 foot = 25.4 mm, 1 pound per foot = 14.5939 N/m. 3 of 8

a. For framing of other species: (1) Find specific gravity for species of lumber in AF&PA NDS. (2) For staples find shear value from table above for Structural I panels (regardless of actual grade) and multiply value by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. (3) For nails find shear value from table above for nail size for actual grade and multiply value by the following adjustment factor: Specific Gravity Adjustment Factor = [1-(0.5-SG)], where SG = Specific Gravity of the framing lumber. This adjustment factor shall not be greater than 1. b. Panel edges backed with 2-inch nominal or thicker framing. Install panels either horizontally or vertically. Space fasteners maximum 6 inches on center along intermediate framing members for 3/8- inch and 7/16-inch panels installed on studs spaced 24 inches on center. For other conditions and panel thickness, space fasteners maximum 12 inches on center on intermediate supports. c. 3/8-inch panel thickness or siding with a span rating of 16 inches on center is the minimum recommended where applied direct to framing as exterior siding. For grooved panel siding, the nominal panel thickness is the thickness of the panel measured at the point of nailing. d. Allowable shear values are permitted to be increased to values shown for 15/32-inch sheathing with same nailing provided (a) studs are spaced a maximum of 16 inches on center, or (b) panels are applied with long dimension across studs. e. Framing at adjoining panel edges shall be 3 inches nominal or thicker, and nails shall be staggered where nails are spaced 2 inches on center. f. Framing at adjoining panel edges shall be 3 inches nominal or thicker, and nails shall be staggered where both of the following conditions are met: (1) 10d (3 x0.148 ) nails having penetration into framing of more than 1-1/2 inches and (2) nails are spaced 3 inches on center. g. Values apply to all-veneer plywood. Thickness at point of fastening on panel edges governs shear values. h. Where panels applied on both faces of a wall and nail spacing is less than 6 inches o.c. on either side, panel joints shall be offset to fall on different framing members, or framing shall be 3-inch nominal or thicker at adjoining panel edges and nails on each side shall be staggered. i. In Seismic Design Category D, E or F, where shear design values exceed 350 pounds per linear foot, all framing members receiving edge nailing from abutting panels shall not be less than a single 3-inch nominal member, or two 2-inch nominal members fastened together in accordance with Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See Section 4.3.6.4.3 of AF&PA SDPWS for sill plate size and anchorage requirements. j. Galvanized nails shall be hot dipped or tumbled. k. Staples shall have a minimum crown width of 7/16 inch and shall be installed with their crowns parallel to the long dimension of the framing members. l. For shear loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above shall be multiplied by 0.63 or 0.56, respectively. m. [DSA-SS, DSA/SS-CC and OSHPD 1, 2 & 4] Refer to Section 2305.1.3, which requires any wood structural panel sheathing used for diaphragms and shear walls that are part of the seismic-forceresisting system to be applied directly to framing members. 4 of 8

TABLE 2306.3(2) ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE a b, h, j, k, l FOR SEISMIC LOADING FOR STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY D, E, OR F PANEL GRADE Structural I Sheathing Sheathing, plywood siding g except Group 5 Species NOMINAL PANEL THICKNESS (inch) FASTENER PENETRATION IN FRAMING (inches) ALLOWABLE SHEAR VALUE FOR SEISMIC FORCES PANELS APPLIED DIRECTLY TO FRAMING NAIL (common) size Fastener spacing at panel edges (inches) 6 4 3 2 e 3/8 8d (2½"x0.131" common) 200 d 200 d 200 d 200 d 7/16 8d (2½"x0.131" common) 255 d 395 d 505 d 670 d 15/32 3/8 8d (2½"x0.131" common) 280 430 550 730 1-1/2 10d (3"x0.148" common) 340 510 665 f 870 1-1/4 6d (2 x 0.113 common) 200 200 200 200 8d (2½"x0.131" common) 200 200 200 200 7/16 8d (2½"x0.131" common) 240 d 350 d 450 d 585 d 15/32 8d (2½"x0.131" common) 260 380 490 640 1-1/2 10d (3"x0.148" common) 310 460 600 f 770 19/32 1-1/2 10d (3"x0.148" common) 340 510 665 f 870 For SI: 1 inch = 25.4 mm, 1 foot = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. For framing of other species: (1) Find specific gravity for species of lumber in AF&PA NDS. (3) For nails find shear value from table above for nail size for actual grade and multiply value by the following adjustment factor: Specific Gravity Adjustment Factor = [1-(0.5-SG)], where SG = Specific Gravity of the framing lumber. This adjustment factor shall not be greater than 1. b. Panel edges backed with 2-inch nominal or thicker framing. Install panels either horizontally or vertically. Space fasteners maximum 6 inches on center along intermediate framing members for 3/8-inch and 7/16-inch panels installed on studs spaced 24 inches on center. For other conditions and panel thickness, space fasteners maximum 12 inches on center on intermediate supports. c. 3/8-inch panel thickness or siding with a span rating of 16 inches on center is the minimum recommended where applied direct to framing as exterior siding. d. Allowable shear values are permitted to be increased to values shown for 15/32-inch sheathing with same nailing provided (a) studs are spaced a maximum of 16 inches on center, or (b) panels are applied with long dimension across studs. e. Framing at adjoining panel edges shall be 3 inches nominal or thicker, and nails shall be staggered where nails are spaced 2 inches on center. f. Framing at adjoining panel edges shall be 3 inches nominal or thicker, and nails shall be staggered where both of the following conditions are met: (1) 10d (3 x0.148 ) nails having penetration into framing of more than 1-1/2 inches and (2) nails are spaced 3 inches on center or less. g. Values apply to all-veneer plywood. Thickness at point of fastening on panel edges governs shear values. h. Where panels applied on both faces of a wall and nail spacing is less than 6 inches o.c. on either side, panel joints shall be offset to fall on different framing members, or framing shall be 3-inch nominal or thicker at adjoining panel edges and nails on each side shall be staggered. i. Where shear design values exceed 350 pounds per linear foot, all framing members receiving edge nailing from abutting panels shall not be less than a single 3-inch nominal member, or two 2-inch nominal members fastened together in accordance with Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See Section 4.3.6.1 and 4.3.6.4.3 of AF&PA SDPWS for sill plate size and anchorage requirements. 5 of 8

j. Galvanized nails shall be hot dipped or tumbled. k. For shear loads of normal or permanent load duration as defined by the AF&PA NDS, the values in the table above shall be multiplied by 0.63 or 0.56, respectively. n. The maximum allowable shear value for three-ply plywood resisting seismic forces is 200 pounds per foot (2.92 kn/m). 6 of 8

TYPE OF MATERIAL TABLE 2306.7 ALLOWABLE SHEAR FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES THICKNESS OF MATERIAL WALL CONSTRUCTION FASTENER SPACING b MAXIMUM (inches) SHEAR VALUE a, e (plf) c, d, j, k FASTENER SIZE 1. Expanded metal, or woven wire lath and Portland cement plaster 7/ 8 Unblocked 6 180 No. 11 gage 1 ½ long, 1/ 16 head No. 16 gage galv. Staple, 7/8 legs 2. Gypsum lath, plain or perforated with vertical joints staggered 3/8 lath and ½ plaster Unblocked 5 180 No. 13 gage galv. 1 1/8 long, 19/ 64 head, plasterboard nail 3. Gypsum lath, plain or perforated 3/8 lath and ½ plaster Unblocked 5 100 No. 16 gage galv. staple, 1 1/8 long, 0.120 nail, min. 3/8 head, 1 ¼ long Unblocked f 7 75 Unblocked f 4 110 Unblocked 7 100 Unblocked 4 125 5d cooler ( 1 5/8 x 0.086 ) or Wallboard 0.120 nail, min. 3/8 Head, 1 ½ long No. 16 gage galv. staple, 1 ½ long Blocked g 7 125 ½ Blocked g 4 150 Unblocked 8/ 12 h 60 Blocked g 4/ 16 h 160 Blocked f, g 4/ 12 h 155 No. 6-1 ¼ screws i Blocked g 8/ 12 h 70 4. Gypsum board, gypsum veneer base or water-re Blocked g 6/ 12 h 90 7 115 Unblocked f 4 145 7 145 Blocked g 4 175 6d cooler ( 1 7/8 x 0.092 ) or Wallboard 0.120 nail, min. 3/8 head, 1 ¾ long No. 16 gage galv. staple, 1 ½ legs, 1 5/8 long 5/8 Blocked g Two-ply Base ply: 9 Face ply : 7 250 Base ply 6d cooler ( 1 7/8 x 0.092 ) wallboard 1 ¾ x 0.120 nail, min. 3/8 head 1 5/8 16 gage galv. staple 1 5/8 16 gage galv. staple Face ply-8d cooler (2 3/8 x 0.113 ) Or wallboard 0.120 nail, min. 3/8 head, 2 3/8 long No. 15 gage galv. staple, 2 ¼ long See page 8 of this Information Bulletin for Footnote to Table 2306.7. Unblocked 8/ 12 h 70 Blocked g 8/ 12 h 90 No. 6 1 ¼ screws i 7 of 8

Table 2306.7 Footnote: For SI: 1 inch = 25.4 mm, 1 foot = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. These shear walls shall not be used to resist loads imposed by masonry or concrete construction (see Section 4.1.5 of AF & PA SDPWS). Values shown are for short-term loading due to wind or seismic loading. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 of ASCE 7. Values shown shall be reduced 25 percent for normal loading. b. Applies to fastening at studs, top and bottom plates and blocking. c. Alternate fasteners are permitted to be used if their dimensions are not less than the specified dimensions. Drywall screws are permitted to substitute for the 5d (1-5/8 x 0.086 ), and 6d (1-7/8 x 0.092 )(cooler) nails listed above, and No. 6 1-1/4 inch Type S or W screws for 6d (1-7/8 x 0.092 )(cooler) nails. d. For properties of cooler nails, see ASTM C 514. e. Except as noted, shear values are based on maximum framing spacing of 16 inches on center. f. Maximum framing spacing of 24 inches on center. g. All edges are blocked, and edge fastening is provided at all supports and all panel edges. h. First number denotes fastener spacing at the edges; second number denotes fastener spacing at intermediate framing members. i. Screws are Type W or S. j. Staples shall have a minimum crown width of 7/16 inch, measured outside the legs, and shall be installed with their crowns parallel to the long dimension of the framing members. k. Staples for the attachement of gypsum lath and woven-wire lath shall have a minimum crown width of ¾ inch, measured outside the legs. 8 of 8