VPL-3300B Commercial Vertical Platform Lift Technical Specifications

Similar documents
VPL-3200B Residential Vertical Platform Lift Technical Specifications

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

VERTICAL PLATFORM LIFT PLANNING GUIDE

SECTION VERTICAL WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Telecab RESIDENTIAL ELEVATOR. Planning Guide

An AIA Continuing Education Program

Introduction. Disclaimer. Table of contents

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

Planning Guide (Imperial)

Multilift Vertical Platform Lift OWNER S MANUAL

Telecab RESIDENTIAL ELEVATOR. Planning Guide

SECTION The specification section is organized by placing information in three standard parts:

Introduction. Disclaimer. Table of contents

ELVORON LU/LA ELEVATOR

ELVORON STELLA HOME ELEVATOR

SECTION INCLINE WHEELCHAIR LIFT PART 1 GENERAL 1.1 SECTION INCLUDES. A. Stair wheel chair lift. 1.2 RELATED SECTIONS

Division 16 Sections for electrical service for elevators to and including disconnect and fused switches at machine room.

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR

Limited Use/Limited Application Elevator DESIGN GUIDE. ASME A17.1, Part V, Section 5.2. LU/LA Hydraulic Drive. symmetryelevator.com

VISTA OWNER S MANUAL ATLAS. VISTA RESIDENTIAL & COMMERCIAL Rev: March 20, 2018 p/n:

F-SERIES: F SPECIFICATIONS Four-Fold Door Systems

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Dealer Planning Guide Telecab

SECTION VERTICAL PLATFORM LIFT

RESIDENTIAL. Legacy PLANNING GUIDE

SECTION RESIDENTIAL ELEVATOR. (Freedom Green Residential Elevator)

F-SERIES: FF XT SPECIFICATIONS Exterior Swinging Four-Fold Door Systems

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

FF200, FOUR-FOLD DOORS CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

SECTION RESIDENTIAL ELEVATOR. (Freedom Elite Residential Elevator)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PART 1- General LULA Elevator Section 14200

Residential Elevator Design Guide

V1504 Planning Guide Dec. 2006

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

REQUEST FOR INFORMATION

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

STRATUS TM. Home Elevators Made Affordable

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

STRATUS TM. Home Elevators Made Affordable

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

You dream it. We build it. ELEVATORS

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

Vuelift Residential Elevator. Planning Guide

Vuelift RESIDENTIAL ELEVATOR PLANNING GUIDE

SERENUS LULA PLANNING GUIDE

DEVICES AND LUMINAIRES

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

SECTION HYDRAULIC PASSENGER ELEVATORS. A. Section ( ) - Cast-in-Place Concrete: Elevator pits.

DEVICES AND LUMINAIRES

Written Specification Content Library

N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

Planning Guide for Limited Use/Limited Application Elevator

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECURITY WITH SOPHISTICATED STYLE

3M Intelligent Return Classic and Sorter System SL. Architect/Contractor's Package

Elevators and Lifts

Specification for MRL Passenger Elevators

LUBRICATION PUMP Z2 CENTRAL LUBRICATION

Roped Hydraulic Residential Elevator Planning Guide

You dream it. We build it. ELEVATORS

DEPARTMENT OF ARCHITECTURE ABUBAKAR TAFAWA BALEWA UNIVERSITY, BAUCHI ARC 624: ADVANCED BUILDING SERVICES LESSON 2: CONVEYANCE SYSTEMS IN BUILDINGS

The following chapters or articles of the New Jersey electrical subcode are amended as follows:

Aluminum Perforated Rolling Door

Specification for Borehole Freight Elevators

Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code

OPTIONS ARE LISTED IN RED, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

LIFT APPLICATION GUIDELINES ACCESSTAIR MODEL VMH-08

Specification for Holeless Freight Elevators

2000-SG STAINLESS STEEL SLIDE GATES

Planning Guide. Limited Use / Limited Application Elevator. Applicable Codes: ASME A17.1 Section 5.2 CAN/CSA B44

SECTION ALUMINUM GATES

Residential Elevators

SECTION HYDRAULIC PASSENGER ELEVATOR

Savaria Eclipse Home Elevator

Technical Data Sheet Signature 842

SECTION DUMBWAITERS

Western Elevator Ltd

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

A. Product Data shall be provided for each type of product indicated.

Section 7: Specifications

Planning Guide. Limited Use / Limited Application Elevator. Applicable Codes: ASME A17.1 Section 5.2 CAN/CSA B44. Part No m

Accessibility, Safety & Platform Lifts and Elevators v2

3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package

3M Intelligent Return Plus and Sorter System FX. Architect/Contractor Package

2600SEG135 SAFETY STANDARD FOR INDUSTRIAL LADDERS AND STAIRCASES IN BUILDINGS

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

RESIDENTIAL BUILDING REQUIREMENTS

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

CIBES A 5000 Platform Lift

SECTION OUTLET, PULL, AND JUNCTION BOXES

Division 14 Conveying Systems

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator

Transcription:

Page 1 of 5 VPL-3300B Commercial Vertical Platform Lift Technical Specifications MODEL NUMBERS: Unenclosed VPL-3300B Series: Models VPL-3353B and VPL-3375B (DC-powered) 3-Gate VPL-3300B Series: Models VPL-3353B (DC-powered) Enclosure (by Bruno) VPL-3300B Series: Models VPL-3353B, VPL-3375B, VPL-3310B, VPL-3312B, and VPL-3314B (DC-powered) Hoistway (by others) VPL-3300B Series: Models VPL-3353B, VPL-3375B, VPL-3310B, VPL-3312B, and VPL-3314B (DC-powered) U.S. F.D.A. CLASSIFICATION: Class II, 510(K) exempt CLASSIFICATION NUMBER: 890.3930 PRODUCT CODE: PCE ETL-Intertek C-US Listed: Control Number: 4004689 PERFORMANCE STANDARDS: ASME A18.1-2011 (Sec. 2) Safety Standards for Platform Lifts and Stairway Chairlifts ASME A18.1-2014 (Sec. 2) Safety Standards for Platform Lifts and Stairway Chairlifts CSA B355-09 Lifts for Persons with Physical Disabilities CSA B355-15 Lifts for Persons with Physical Disabilities (Commercial Application) CSA B44.1-11/ASME A17.5-2011 Elevator and Escalator Electrical Equipment CSA B44.1-14/ASME A17.5-2014 Elevator and Escalator Electrical Equipment RATED LOAD: 750 lb (340 kg) maximum NUMBER OF PASSENGERS: 1 passenger with mobility device APPLICATIONS: Commercial, Indoors, Outdoors DRIVE: DC battery-powered units: o primary drive: 1/2 hp motor, 1750 rpm, 24VDC permanent magnet, 20 full-load amps, continuous duty (VPL-3353B and VPL-3375B) o primary drive: 1 hp motor, 1750 rpm, 24VDC permanent magnet, 20 full-load amps, continuous duty (VPL-3310B, VPL-3312B and VPL-3314B) o 5A, 24VDC output internal battery charger, 120VAC, 60 Hz, 3A maximum input power required INTERMEDIATE REDUCTION: dual 4L style poly-v belts and pulleys, 3.94:1 pulley reduction FINAL DRIVE: 1 (25.4 mm) diameter Acme screw with bronze nut and bronze safety back up nut (VPL-3353B & VPL-3375B) 1 1/4" (32 mm) diameter Acme screw with bronze nut and bronze safety back up nut (VPL-3310B, VPL-3312B, & VPL-3314B) MOTOR CONTROLLER: DC battery-powered units: 24VDC relay control with 35A circuit breaker and disconnect (VPL-3353B & VPL-3375B) DC battery-powered units: 24VDC relay control with 60A circuit breaker and disconnect (VPL-3310B, VPL-3312B & VPL-3314B) BRAKING: DC battery-powered units: precision landing control STANDARD CONTROL: up and down rocker switch or paddle controls, continuous pressure, key switch control, lighted controls EMERGENCY STOP SWITCH: red, sealed, 1.55 (39 mm) diameter mushroom head, illuminated with audio alarm, push to stop, pull to reset SPEED: DC battery-powered units: 10 ft/min (0.05 m/s) maximum NUMBER OF LANDINGS: 2-Stop (VPL-3353B, VPL-3375B, VPL-3310B, VPL-3312B, and VPL-3314B) 3-Stop (optional for VPL-3310B, VPL-3312B, and VPL-3314B)

Page 2 of 5 MAIN FRAME CONSTRUCTION: welded steel tubular guide construction with formed sheet steel guarding CARRIAGE CONSTRUCTION: welded carriage with 2.25 (57 mm) diameter front and back sealed dual-ball-bearing wheels and adjustable low-friction plastic side stabilizer guide pads LIFTING HEIGHT: Model VPL-3353B (Unenclosed, Enclosure, Hoistway and 3-Gate): 53 (1346 mm) maximum floor-to-floor height and 11 (279 mm) minimum floor-to-floor height; Model VPL-3375B (Unenclosed): 60 (1524 mm) maximum floor-to-floor height and 32 (813 mm) minimum floor-to-floor height Model VPL-3375B (Enclosure and Hoistway): 75 (1905 mm) maximum floor-to-floor height and 32 (813 mm) minimum floor-to-floor height Model VPL-3310B (Enclosure and Hoistway): 123 (3124 mm) maximum floor-to-floor height; Model VPL-3312B (Enclosure and Hoistway): 147 (3734 mm) maximum floor-to-floor height; Model VPL-3314B (Enclosure and Hoistway): 171 (4343 mm) maximum floor-to-floor height For pit applications, maximum floor-to-floor is measured from the bottom of the pit to the upper landing. [Check local codes for maximum lifting height for unenclosed applications. ASME A18.1 (Sec. 2.7.1) limits maximum floor-to-floor to 60 (1524 mm).] PLATFORM CONSTRUCTION: totally enclosed side walls consisting of 1 (25 mm) tubular framing and sheet metal siding ENCLOSURE CONSTRUCTION: aluminum frame with Plexiglas and steel panels UNDER CARRIAGE SAFETY: totally enclosed bottom formed steel safety pans for unenclosed applications only AUTOMATIC LOWER RAMP: 16 (406 mm) long self-lowering ramp (standard on unenclosed applications) EMERGENCY LOWERING: external lockable keyed switch for lowering platform by means of a separate battery located inside the electrical enclosure (models VPL-3310B, VPL-3312B, and VPL-3314B) FINISH: exterior grade powder coat paint (standard color is champagne with anti-skid graphite gray platform floor and ramp) E-coated legs, platform and landing gate parts E-coated enclosure parts made of steel LIMIT SWITCHES: adjustable upper and lower limit switches; upper and lower final limit switches MANUAL LOWER DEVICE: optional; manual hand crank to lower device available; access to adaptive shaft via safety interlocked top cap REMOTE CONTROL: optional; station includes a separate landing call/send rocker switch or paddle controls and a keyed on/off switch LOWER LANDING GATE (3-Gate): standard; includes Bruno mechanical interlock which releases door, only when platform is at lower landing; electronic sensors stop platform from operating unless door is closed; also includes call/send rocker switch or paddle controls and keyed on/off switch mounted into gate frame or remote mount TOP LANDING GATE: optional; includes Bruno electrical mechanical interlock (EMI) or electric strike interlock (ESI) which releases door, only when platform is at upper landing; electronic sensors stop platform from operating unless door is closed; also includes call/send rocker switch or paddle controls and keyed on/off switch mounted into gate frame or remote mount; steel, clear Plexiglas, or bronze Plexiglas insert panels PLATFORM GATE (Unenclosed & 3-Gate): standard; includes Bruno electrical mechanical interlock which releases door, only when platform is at lower landing. Electronic sensors stop platform from operating unless door is closed

Page 3 of 5 FLUSH MOUNT DOOR: optional; includes electric strike interlock (ESI) which releases door only when platform is at door landing; electronic sensors stop platform from operating unless door is closed; offered as an oak door with steel frame (no fire rating) or a steel door with steel frame (90 min. fire rating including a viewing window); delay action hydraulic closer; keyed ESI for bypass entry; also available in an aluminum frame and door with clear or bronze panels STATIONARY RAMP (Hoistway): optional; 24 L x 36 W x 3 H (610 mm L x 914 mm W x 76 mm H) aluminum stationary ramp with anti-skid graphite gray powder coat. (3-Gate): standard; 24 L x 41 W x 3 H (610 mm L x 1041 mm W x 76 mm H) aluminum stationary ramp with anti-skid graphite gray powder coat. (Enclosure 36 Door): standard; 24 L x 42 W x 3 H (610 mm L x 1067 mm W x 76 mm H) steel stationary ramp with E-coated anti-skid graphite gray powder coat. (Enclosure 45 Door): standard; 24 L x 51 W x 3 H (610 mm L x 1295 mm W x 76 mm H) steel stationary ramp with E-coated anti-skid graphite gray powder coat. WEIGHT OF UNIT: DC battery-powered units: o Model VPL-3353B: 857 lb (388 kg) (without batteries) (with batteries +40 to 80 lb /18 to 36 kg) o Model VPL-3375B: 930 lb (422 kg) (without batteries) (with batteries +40 to 80 lb /18 to 36 kg o Model VPL-3310B: 1210 lb (549 kg) (with batteries) o Model VPL-3312B: 1304 lb (591 kg) (with batteries) o Model VPL-3314B: 1400 lb (635 kg) (with batteries) All Models: Top Landing Gate Option: 99 lb (45 kg) Top Landing Wide Gate Option: 108 lb (49 kg) 3-Gate: Lower Landing Gate and Walls: 130 lb (59 kg) Enclosure (used with a Gate on the top landing): Enclosure Walls, Full Height Door, and Ramp: 520 lb (236 kg) (model VPL-3353B) 600 lb (272 kg) (model VPL-3375B) 680 lb (308 kg) (model VPL-3310B) 760 lb (345 kg) (model VPL-3312B) 840 lb (381 kg) (model VPL-3314B) TESTING PERFORMED: 1) life cycle test performed at manufacturer s location 2) ASME A18.1-2014 (Sec. 2) and CSA B355-15 code tests performed at manufacturer s location OPTIONS: 1) tool for manual lowering device 2) platform canopy (not available for 90º platforms, 42 x 60 straight-through platforms, or Enclosures) 3) telephone kit (ADA compliant with battery backup) 4) battery package upgrade - 34 AH battery package (VPL-3353B and VPL-3375B) 5) cold-weather package [recommended if operating temperature is below 20ºF (-7ºC)] 6) pit switch 7) door/gate operator (used for power-assisted top landing door/gate, lower landing gate on 3-Gate, and lower landing door on enclosure) 8) platform gate operator (used for power-assisted platform gate on unenclosed models) 9) single timer (used with electric strike interlocks on 3-stop middle landing) 10) flood zone tower (electronics and batteries located on top section of tower)

Page 4 of 5 VPL Job Site Preparation The following is a list of general operations designed to prepare the job site for installation of the VPL. This list is provided as a guide to help the installer. For a complete list of requirements check the installation site s applicable local codes. Electrical Requirements: DC battery-powered units: Check applicable local codes for all electrical and wiring requirements. If it is determined that a GFI (Ground Fault Interrupter) outlet is required; use a GFI 120V, 15A, 60 Hz single phase circuit to operate the internal battery charger (charger draws 3A max.). National Electrical Code requires a GFI is used in all outdoor or wet environment applications. Platform Pathway Requirements: Make sure the pathway that the platform runs in is clear of any electrical conduit and wire ways. Make sure no liquids, steam or gas piping discharge into the pathway, and make sure that there is sufficient headroom clearance (minimum of 80 2032 mm) throughout floor-to-floor travel. Make sure the area is sufficiently lit. Floor Recommendations: 4 (102 mm) thick, 3500 PSI minimum compressive strength, reinforced concrete slab. Refer to technical drawings for minimum slab dimensions. If the temperature can fall below freezing, it is recommended that you insert an insulation sheet between the concrete slab and the compacted rock. Floor Attachment: VPL must be fastened to concrete slab using four (4) 1/2 (3/8 bolt) x minimum 2-1/2 long concrete anchors suitable for the environment. Refer to technical drawings for mounting hole locations. Follow selected concrete anchor manufacturer s guidelines and applicable codes. Housing Attachment: Unenclosed: None required. Can use 5/16-18 tapped holes on tower frame work to fasten the tower housing to a vertical wall for additional stability. Note: Housing must remain intact. 3-Gate: Lower landing walls must be secured to the house (fascia) with the brackets provided. Note: Housing must remain intact. Hoistway (by other): Use 5/16-18 tapped holes on tower frame work to fasten the tower housing to a vertical wall near or above the upper landing (200 lb/91 kg wall loading). Mounting brackets are supplied with unit. Lower Landing Gate Attachment (3-Gate): Refer to 3-Gate technical drawing (see below). Top Landing Gate Attachment: Refer to VPL gate technical drawing (see below). Flush Mount Door Attachment: Refer to VPL flush mount door detail drawing (see below). Space Requirements: Refer to technical drawings (see below). Platform-to-Top Landing Sill Clearance: ASME code indicates the platform floor-to-sill clearance at the upper landing shall not be less than 3/8 (9.5 mm) nor exceed 3/4 (19 mm). Follow applicable local codes. Fascia Wall Requirements: ASME code indicates that fascia should be smooth and non-perforated that guards the full length and width of the platform. The fascia shall be securely fastened from the upper landing sill down to the lower landing sill. It should also be able to withstand a 125-pound side load over any 4-inch square area. Follow applicable local codes.

Page 5 of 5 Technical Drawings (available at www.bruno.com): Canopy ILS-00846 Canopy Detail Gates and Doors ILS-00938 Top Landing Gate Detail ILS-01027 Flush Mount Door Detail with a Wood or Steel Door ILS-01194 Flush Mount Aluminum Door with Clear or Bronze Panels Unenclosed - Models VPL-3353B and VPL-3375B ILS-01102 Unenclosed Straight-Through Platform With Platform Gate (No Pit) ILS-01103 Unenclosed Straight-Through Platform With Platform Gate (Pit Application) ILS-01104 Unenclosed 90º/Adjacent-Exit Platform With Platform Gate (No Pit) ILS-01105 Unenclosed 90º/Adjacent-Exit Platform With Platform Gate (Pit Application) Partial Enclosure (3-Gate) - Model VPL-3353B ILS-01154 Enclosed Straight-Through Platform With 3-Gate (Pit Application) ILS-01155 Enclosed Straight-Through Platform With 3-Gate (No Pit) Hoistway - Models VPL-3353B, VPL-3375B, VPL-3310B, VPL-3312B, and VPL-3314B ILS-01176 Hoistway Straight-Through Platform (No Pit) ILS-01177 Hoistway Straight-Through Platform (Pit Application) ILS-01178 Hoistway 90º/Adjacent-Exit Platform (No Pit) ILS-01179 Hoistway 90º/Adjacent-Exit Platform (Pit Application) ILS-01253 Hoistway Same Side Platform (No Pit) ILS-01254 Hoistway Same Side Platform (Pit Application) Enclosure - Models VPL-3353B and VPL-3375B ILS-01215 Enclosure Straight-Through Platform (No Pit) ILS-01216 Enclosure Straight-Through Platform (Pit Application) ILS-01241 Enclosure 90º/Adjacent-Exit Platform (No Pit) ILS-01242 Enclosure 90º/Adjacent-Exit Platform (Pit Application) Enclosure Models VPL-3310B, VPL-3312B, and VPL-3314B ILS-01277 Enclosure Straight-Through Platform (No Pit) ILS-01278 Enclosure Straight-Through Platform (Pit Application) ILS-01289 Enclosure Same Side Platform (No Pit) ILS-01290 Enclosure Same Side Platform (Pit Application) ILS-01318 Enclosure 90º/Adjacent-Exit Platform (No Pit) ILS-01319 Enclosure 90º/Adjacent-Exit Platform (Pit Application)