Expand your forensics workflow with the Precision ID NGS System for human identification

Similar documents
Expand your forensics workflow with the Precision ID NGS System for human identification with mtdna, SNP, and STR analysis

Introducing the Applied Biosystems TM Precision ID NGS System for Human Identification

Converge Software. A comprehensive forensic analysis platform that integrates answers for you

Ion S5 and Ion S5 XL Systems

Ion S5 and Ion S5 XL Systems

Ion S5 and Ion S5 XL Systems

GenPlex HID Training Class I

Jennifer D. Churchill, Maiko Takahashi, Christina Strobl, Dixie Peters, Christina Capt, Walther Parson, Bruce Budowle

Converge Software. A comprehensive forensic analysis platform that integrates answers for you

Sequencing and PCR. Training: Ion S5 and S5 XL Systems workflow training

EVALUATION OF THEPRECISIONID SYSTEM FOR TARGETED SEQUENCING OF DNA AND RNA MARKERS FOR HUMAN IDENTITY AND BODY FLUID IDENTIFICATION

Forensic Applications of CE and MPS

Data Quality Worth Sharing

Get more information from challenging samples with next-generation sequencing of short tandem repeats

Evaluation of NGS technology for identification, ancestry prediction and phenotypic characters prediction with the Ion PGM System

Development and characterization of a high throughput targeted genotypingby-sequencing solution for agricultural genetic applications

Product selection guide Ion S5 and Ion S5 XL Systems

Innovative. Intelligent. Intuitive.

Precise quantification of Ion Torrent libraries on the QuantStudio 3D Digital PCR System

Accessible answers. Targeted sequencing: accelerating and amplifying answers for oncology research

Genetic Identity. Steve Harris SPASH - Biotechnology

High Cross-Platform Genotyping Concordance of Axiom High-Density Microarrays and Eureka Low-Density Targeted NGS Assays

Product selection guide Ion GeneStudio S5 Series

Validation of Identity and Ancestry SNP Panels for the Ion PGM

FORENSIC GENETICS. DNA in the cell FORENSIC GENETICS PERSONAL IDENTIFICATION KINSHIP ANALYSIS FORENSIC GENETICS. Sources of biological evidence

Reliable. answers, significant savings. Applied Biosystems QuantStudio 5 Real-Time PCR System for Human Identification

HID Real-Time PCR Analysis Software v1.3

First Look: Applied Biosystems NGM Detect PCR Amplification Kit

PowerSeq 46GY System Eases the transition to MPS for forensic laboratories

SeqStudio Genetic Analyzer

From Forensic Genetics to Genomics Perspectives for an Integrated Approach to the Use of Genetic Evidence in Criminal Investigations

Variant calling workflow for the Oncomine Comprehensive Assay using Ion Reporter Software v4.4

Empowering genotyping by sequencing in animal applications - the power of partnering.

Targeted Sequencing in the NBS Laboratory

NEW TECHNOLOGIES - AN INTRODUCTION

SEQUENCING FROM SAMPLE TO SEQUENCE READY

Get to Know Your DNA. Every Single Fragment.

AmpFlSTR Identifiler PCR Amplification Kit

Applications and Early Access Results on SeqStudio Genetic Analyzer

AmpF STR NGM PCR Amplification Kit - Overview

DNA Expert Witness. Nuclear DNA 10/23/14. Adams County Bar Association. DNA found in the nucleus of the cell is called nuclear DNA.

Artifacts Identified Post-Developmental Validation: AmpFLSTR Identifiler Plus PCR Amplification Kit

Development and Validation of the 3500 Series Genetic Analyzer for Human Identification

Implementation of MPS into a Specialist Casework Laboratory. David Ballard

MHC Region. MHC expression: Class I: All nucleated cells and platelets Class II: Antigen presenting cells

The Real CSI: Using DNA to Identify Criminals and Missing Persons

solid S Y S T E M s e q u e n c i n g See the Difference Discover the Quality Genome

Product Catalog 2012 AmplGen Ltd.

Analytical verification methods for the Oncomine Lung cfdna Assay using the Ion S5 XL System

The injection of the 28 and 29 PCR cycle data was performed at 3kV for 10 and 5 seconds.

QIAseq SPE technology for Illumina : Redefining amplicon sequencing

Detect low-level somatic mutations in FFPE samples using an extended RAS research assay

Forensic News. FAS Corner April The Maximizing Data Quality Series Part 2: DNA Quantitation

Matthew Tinning Australian Genome Research Facility. July 2012

Illumina s Suite of Targeted Resequencing Solutions

GlobalFiler Kit Casework Test Site Results and Other Development Updates

HID Validation: The 3500 Series Genetic Analyzers

Investigator Quantiplex HYres Kit

Analysis in Forensic Science

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

MicroSEQ TM ID Rapid Microbial Identification System:

Functional DNA Quality Analysis Improves the Accuracy of Next Generation Sequencing from Clinical Specimens

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

Relative Fluorescent Quantitation on Capillary Electrophoresis Systems:

What is DNA? Deoxyribonucleic Acid The inherited genetic material that makes us what we are

DNA Analysis Students will learn:

The STAR Q Swab AS Instrument for highthroughput PCR setup of QIAGEN s Investigator STR GO! Kits

Welcome to the NGS webinar series

Simplify your pathogen testing. Amplify your confidence.

Exploring of microrna markers for body fluid identification using NGS

Laboratory Validation. Chapter 16

GeneMarker HID Expert System Human Identification Software with Linked Post-Identification Database Search, Kinship, and DNA Mixture Applications

Create a Planned Run. Using the Ion AmpliSeq Pharmacogenomics Research Panel Plugin USER BULLETIN. Publication Number MAN Revision A.

Procedure for Casework DNA Interpretation

KAPA hgdna QUANTIFICATION AND QC KIT:

Mutations during meiosis and germ line division lead to genetic variation between individuals

TAKE YOUR NEXT STEP WITH CONFIDENCE

Fluent for Genomic Workflows INCREASED PRODUCTIVITY POWERED BY TECAN S AUTOMATION WORKSTATION

Authenticating human cell lines using the Identifiler kits and capillary electrophoresis platforms

STR DNA Data Analysis. Genetic Analysis

GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS. Genomics Solutions Portfolio

TaqPath ProAmp Master Mixes

TRANSCRIPTOME SEQUENCING. RNA sequencing solutions. Simple, fast, and affordable. PG1595-PJT1209-COL11768-Ion-RNA-Expressions-Updates-Global.

NGS Sample QC with the Agilent 2200 TapeStation. Rainer Nitsche Application Engineer Agilent Technologies, Inc.

Axiom mydesign Custom Array design guide for human genotyping applications

DEVELOP YOUR LAB, YOUR WAY. The FLOW Solution: Expand your potential today

Microbial sequencing solutions

From Genetics to Genomics European Perspectives for an Integrated Approach to the Use of Genetic Evidence in Criminal Investigations

Getting high-quality cytogenetic data is a SNP.

HaloPlex HS. Get to Know Your DNA. Every Single Fragment. Kevin Poon, Ph.D.

fastest next-gen workflow 10X more throughput fastest-selling sequencer all in six months Ion Personal Genome Machine Sequencer

GENOMICS WORKFLOW SOLUTIONS THAT GO WHERE THE SCIENCE LEADS. Genomics Solutions Portfolio

A new paradigm in testing for NSCLC-targeted therapies

Introduction to Mitochondrial DNA Analysis

Upgrading the Workflow: Enhancing Information Recovery from Forensic Evidence. The world leader in serving science

Platinum II Taq Hot-Start DNA Polymerase for high-throughput PCR

Sample to Insight. Dr. Bhagyashree S. Birla NGS Field Application Scientist

Lab methods: Exome / Genome. Ewart de Bruijn

King s Research Portal

SNP GENOTYPING WITH iplex REAGENTS AND THE MASSARRAY SYSTEM

Transcription:

Expand your forensics workflow with the Precision ID NGS System for human identification

Integrate NGS into your forensic DNA lab workflow The Applied Biosystems Precision ID NGS System for human identification can help you solve tough cases by getting more information from your challenging samples. Now you have help moving those unknown samples from storage to investigative leads. Adopting next-generation sequencing (NGS) for forensic DNA analysis in your laboratory is simpler than ever, when you combine the Ion Chef System and Ion S5 or Ion S5 XL Systems with optimized Precision ID library preparation, template preparation and sequencing kits, and forensically relevant panels. Precision ID panels are powered by Ion AmpliSeq technology, which applies the simplicity of PCR to targeted sequencing and enables amplification from tens to thousands of genomic regions simultaneously in a single PCR tube. Let the evidence speak for itself. You can choose from a suite of targeted Precision ID panels for the NGS solution for your cases. Short tandem repeat (STR) panels provide high-resolution genotyping of STRs for analysis of complex mixtures. Ancestry-informative or phenotypic singlenucleotide polymorphism (SNP) analysis may help generate investigative leads when suspects are unknown. Identitytesting SNPs can associate a degraded crime scene sample to a known reference when partial results are obtained with autosomal STR analysis. Mitochondrial DNA (mtdna) from samples recovered at mass disasters and from other unidentified remains can routinely be analyzed to assist in human identification, and help establish links to related family members. Process unsolved and missing persons cases with NGS in your lab today. With as little as 1 ng of DNA input, you can go from extracted DNA to profile in as few as 5 pipetting steps and 45 minutes of hands-on time (Figure 1). Total hands-on time: less than 45 minutes Total overall time: as little as 25.5 hours Construct library Prepare template Run sequence Analyze data Hands-on time: 15 minutes Total time: 7 hours Hands-on time: 15 minutes Total time: 11 hours Hands-on time: <15 minutes Total time: as little as 2 hours Total time: as little as 5 hours Precision ID panels Ion Chef System Ion S5 System Converge and Torrent Suite Software Figure 1. Precision ID workflow. Ion Torrent Precision ID Library preparation for STR, SNP, and mtdna panels can be automated using the Ion Chef System, with the exception of STRs for the Ion PGM System, which must be prepared manually. Libraries are processed further on the Ion Chef System for emulsion PCR, enrichment, and loading onto Ion chips. 2

Panels for human identification Analyze DNA mixtures The Applied Biosystems Precision ID GlobalFiler NGS STR Panels (Ion PGM System) and v2 (Ion S5 System) include the same 21 autosomal STRs along with Y markers and amelogenin sex markers found in the Applied Biosystems GlobalFiler PCR Amplification Kit. Instead of using SE-33, these panels include additional multi-allelic STR markers to aid in mixture resolution for complex casework samples. Using a small sample input of as little as 125 pg of DNA (Figure 2) with this targeted forensic marker panel enables you to go from sample extraction to genotyping in less than 2 days using the Precision ID NGS System and the Applied Biosystems Converge Software 2.0 with an NGS Analysis module. The Precision ID GlobalFiler NGS STR solution provides information about STR allele calls, STR sequence motifs, known SNPs in flanking regions, and isometric heterozygotes (alleles of the same fragment length but containing different sequences) (Figure 3). Sample concordance (1 ng vs. 125 pg) 105% 1,800 1,750 Concordance 100% 95% 90% 85% 1,700 1,650 1,600 1,550 1,500 1,450 Total marker count 1 ng 125 pg Marker count 80% Sample 1 Sample 2 Sample 3 Sample 4 Sample 5 Sample 6 Sample 7 Sample 8 Sample 9 Sample 10 Sample 11 Sample 12 Sample 13 Sample 14 Sample 15 Sample 16 Sample 17 Sample 18 Sample 19 Sample 20 Sample 21 Sample 22 Sample 23 Sample 24 Sample 25 Sample 26 Sample 27 Sample 28 Sample 29 Sample 30 Sample 31 1,400 Figure 2. Sample concordance for input amounts of 1 ng vs. 125 pg. The two input amounts of population DNA samples were used in library preparation on the Ion Chef System with the Precision ID GlobalFiler NGS STR Panel v2 and Precision ID DL8 Kit. The samples were sequenced on the Ion S5 System with the Ion S5 Precision ID Chef & Sequencing Kit. Allele calls were concordant between the 1 ng and 125 pg input amounts. Figure 3. Detailed information on isometric heterozygote analysis with sequencing coverage and repeat motif details. Quality values for data analysis (AN, OL, below PHR, and BST) are user-defined values to streamline interpretation. 3

Generate more investigative leads The Applied Biosystems Precision ID Ancestry Panel includes 165 autosomal markers (SNPs) that can provide you with biogeographic ancestry information and guide your investigative process. Fifty-five of these markers were selected based on a publication by Kenneth Kidd [1], and 123 markers were selected based on a publication by Michael Seldin [2]. With small amplicon sizes (<130 bp), this panel is also optimized for degraded DNA samples. Using a small sample input of as little as 1 ng of DNA, you can go from sample extraction to genotyping in a little over a day using the Precision ID NGS System and HID SNP Genotyper plug-in for analysis. 13 overlapping SNPs 123 SNPs from M. Seldin 123 55 55 SNPs from K. Kidd 165 165 SNPs Analyze degraded or trace DNA The Applied Biosystems Precision ID Identity Panel, comprising 124 markers, provides discrimination of individuals similar to STR genotype match probabilities used by forensic analysts. This high discrimination power is achieved by using 34 upper Y-clade SNPs and 90 autosomal SNPs that have high heterozygosity and low fixation index (F ST ), described in publications by Kenneth Kidd [3] and the SNPforID Consortium [4,5]. Due to the shorter amplicons required for sequencing, SNPs enable high recovery of information from challenging samples such as samples from mass disasters, low copy number samples, or low-quality samples. 34 34 upper Y-clade SNPs 48 43 43 K. Kidd 48 SNPforID SNPs SNPlex system (1 shared SNP) 90 autosomal SNPs 124 124 SNPs 4

Analyze evidence from missing persons or remains from disaster victims The Applied Biosystems Precision ID mtdna Whole Genome Panel is an innovative approach to mtdna sequencing specifically developed for forensic applications. This mtdna tiling approach includes two primer pools of 81 small amplicons in each pool, with an average size of 163 bp, to assist with obtaining optimal mitochondrial genome coverage data from highly compromised, degraded samples such as hair shafts, teeth, and bones. The Applied Biosystems Precision ID mtdna Control Region Panel is based on the same mtdna tiling approach used in the Precision ID mtdna Whole Genome Panel. This targeted control region panel contains two smaller sets of primer pools with 7 amplicons in each pool that span the 1.2 kb control region, which encompasses hypervariable (HV) regions I, II, and III, with the same optimal coverage for degraded forensic samples. pool 1 pool 2 Human mtdna 16,569 bp Choose from our extensive menu or customize your own Whether you select from our extensive menu of predesigned assays or create your own custom panel, your panel will enable high coverage and performance. Our online Ion AmpliSeq Designer tool puts you in the driver s seat, enabling customized designs for DNA and RNA targets. Optimized for coverage across selected genomic regions and amplicon size, our Ion AmpliSeq Designer tool uses the same powerful design engine as our predesigned panels. Community panels, such as the Ion AmpliSeq DNA Phenotyping Panel, are designed with input from leading forensic scientists and can be ordered on ampliseq.com Get more from your sample The Ion Chef System automates library preparation from Precision ID panels. Most panels have a 1-pool design and can be combined to take advantage of the Ion Chef System s multiplexing capability. Precision ID reagents and sequencing kits are fully optimized for all available HID NGS panels (STR, SNPs, and mitchondrial DNA). 5

Simple, reproducible automated workflows for Ion Torrent sequencing The Ion Chef System simplifies the workflow for the Ion S5 and Ion PGM Systems, providing a reproducible walk-away solution for automated Precision ID library preparation, automated template preparation, and chip loading, with optimized Precision ID library and templating kits, giving you more time to focus on other critical lab tasks and solve cases. Ion Chef System Automates library generation, equalization, and pooling for Precision ID 1- and 2-pool designs for up to 8 samples in a single instrument run Simplifies template preparation and chip loading using a single automated process for loading of up to two Ion Torrent semiconductor sequencing chips per instrument run Maintains very low inter-run cross-contamination rate of <0.01% Helps save time and labor with just 15 minutes of hands-on time for setup prior to start of each automated workflow (Figure 4) Supports all Ion Torrent semiconductor chips and sequencing chemistries Helps reduce sources of variability for forensic scientists of any experience level Ensures reproducible results minimal pipetting helps reduce experimental variability Manual centrifugation steps Hands-on time 0 steps 0.75 hours 3 hours 19 steps Ion S5 with Ion Chef Systems Illumina MiSeq System Confidence in sequencing results Now you can reduce day-to-day variation in manual workflows to help provide consistent results have peace of mind and confidence in your data. Onboard reagent tracking 2D barcodes associated with all reagents and consumables minimize the potential for user error and help ensure every run is correctly set up (Figure 5) Coefficient of variation 50% 40% 30% 20% 10% Ion OneTouch 2 System Ion Chef System Total workflow time 21 hours 32 hours 0% No. of reads Base coverage Loading efficiency Figure 4. Comparison of the Ion Chef/Ion S5 Systems combination to the Illumina MiSeq System. The combination of the Ion Chef and Ion S5 Systems delivers data 30% faster with 75% less hands-on time. Workflow metrics were compiled from the respective product user guides. Figure 5. Comparison of reproducibility across NGS metrics for Ion AmpliSeq libraries processed (templating and chip loading) using the Ion Chef and Ion OneTouch 2 Systems. While both systems exhibit excellent reproducibility, the Ion Chef System demonstrates lower coefficients of variation (CV) across all metrics. 6

Ion S5 and Ion S5 XL Systems Want to sequence SNP panels on Monday, mtdna panels on Wednesday, and STR panels on Thursday? The Ion S5 Systems let you leverage a single benchtop instrument that scales to your applications and throughput needs. The Ion S5 and Ion S5 XL Systems provide the simplest DNA-to-data workflow for targeted sequencing with industry-leading speed and affordability, so you can spend less time doing repetitive lab work and more time answering the critical questions in your investigations. Simplicity ready, set, sequence Less than 15 minutes of sequencer hands-on time Less than 45 minutes of hands-on time for a DNA-to-data targeted sequencing workflow Speed because every hour counts As little as 2 hours hours for a sequencing run using the Ion S5 Precision ID Ion Chef & Sequencing Kit Go from DNA to data in just over a day Small sample input because every sample matters As little as 125 pg of DNA needed to generate human identification STR profiles Scalability single sequencer, multiple applications Multiple chip formats and read lengths to match your throughput needs (Tables 1 and 2) Analyze STR, mtdna, and SNP targets Simple data analysis and storage Plan, monitor, and track your runs in Torrent Suite Software, and analyze STR profiles in Converge Software Interpret SNP and mtdna variants with easy-to-use Torrent Browser plug-ins Service and support More than 3,700 global sales, service, and technical support specialists are available to assist you in person, by phone, or online including our Human Identification Professional Services (HPS) team that can help you successfully navigate the validation process required to bring new technologies into your lab 7

Table 1. Run and analysis times for the Ion S5 System, Ion S5 XL System, and Ion PGM System. Ion S5 System Ion S5 XL System Ion 520 Chip Ion 530 Chip Ion 520 Chip Ion 530 Chip Reads 3 5 million 15 20 million 3 5 million 15 20 million SNP panels 2.5 hr 2.5 hr 2.5 hr 2.5 hr Run time mtdna whole genome panel 2.5 hr 2.5 hr 2.5 hr 2.5 hr mtdna control region panel 2.5 hr 2.5 hr 2.5 hr 2.5 hr STR panel 2.0 hr 2.0 hr 2.0 hr 2.0 hr SNP panels 5 hr 8 hr 1 hr 2.5 hr Analysis time mtdna whole genome panel 5 hr 8 hr 1 hr 2.5 hr (aligned BAM) mtdna control region panel 5 hr 8 hr 1 hr 2.5 hr STR panel 10 hr 20 hr 2.0 hr 3.5 hr Ion PGM System Ion 314 Chip Ion 316 Chip Ion 318 Chip Reads 400,000 550,000 2 3 million 4 5.5 million Run time Analysis time (aligned BAM) SNP panels 2.3 hr 3 hr 4.5 hr mtdna whole genome panel 2.3 hr 3 hr 4.5 hr mtdna control region panel 2.3 hr 3 hr 4.5 hr STR panel 3.7 hr 4.9 hr 7.3 hr SNP panels 1.5 hr 2.5 hr 4 hr mtdna whole genome panel 1.5 hr 2.5 hr 3.5 hr mtdna control region panel 1.5 hr 2.5 hr 3.5 hr STR panel 2.5 hr 3.5 hr 4.5 hr Table 2. Number of samples per run per chip format. Category Panel Ion S5 Chips Ion PGM Chips Ion 520 Chip Ion 530 Chip Ion 314 Chip Ion 316 Chip Ion 318 Chip SNP mtdna STR Precision ID Ancestry Panel* 48 192 4 24 48 Precision ID Identity Panel** 64 264 6 32 64 Precision ID mtdna Whole Genome Panel 16 64 2 8 16 Precision ID mtdna Control Region Panel 96 384 8 64 96 Precision ID GlobalFiler NGS STR Panel 8 32 2 8 16 * Average 594x coverage. ** Average 738x coverage for autosomal SNPs and 236x coverage for Y SNPs. 1,750x coverage of the mitochondrial genome. 1,750x coverage of the control region. Minimum 500x coverage. Precision ID GlobalFiler NGS STR Panel v2 is used with the Ion S5 System and Precision ID GlobalFiler NGS STR Panel is used with the Ion PGM System. 8

Integrated NGS analysis Converge Software with an NGS Analysis module is required to generate profiles from the Precision ID GlobalFiler NGS STR Panel v2. The integrated HID STR genotyper functionality provides information on STR allele calls, STR sequence motifs, known SNPs in flanking regions, and isometric heterozygotes. With an interface similar to that of Applied Biosystems GeneMapper ID-X Software, you will be able to quickly evaluate sequencing data using familiar process quality values (PQV) and flags such as allele number (AN), off-ladder allele (OL), peak height ratio (PHR), below stochastic threshold (BST), and control concordance (CC) (Figure 6). Preconfigured analysis settings are provided within the NGS module and may be modified by the laboratory as needed. Additionally, full auditing functionality is included for chain-of-custody requirements. Figure 6. View of secondary NGS analysis results with Converge Software 2.0 and NGS Analysis module. 9

Easily compare NGS and CE profile data As forensic laboratories begin to adopt sequence analysis of STR markers into casework applications, validation and concordance studies will be required. Using both the NGS Analysis module and the Case Management module of Converge Software allows for easy comparison of NGS and capillary electrophoresis profiles (Figure 7). This feature will also be useful when comparing a crime scene sample analyzed with NGS to a reference sample that has been processed using traditional methods. Case management Underlying the centralization of data creation, analysis, and storage to one easy-to-access location, the Converge Case Management module supports case, subject, genotype profile, and laboratory data management. It also allows for automated data transfer between various forensic DNA laboratory systems and efficient management of daily operations. The module serves the needs of various users such as laboratory managers and analysts, providing intuitive data views and reports that are configurable to the needs of each user and preserved for that user s login. Figure 7. Comparison of NGS and two CE profiles (imported from GeneMapper ID-X Software) via the Converge Case Management module. 10

Ion Torrent HID software plug-ins Raw data, base calling, variant calling, and genotyping are processed on the Ion S5 System or, in the case of the Ion S5 XL System, transferred to a dedicated Ion S5 Torrent Server for faster analysis. Torrent Suite Software is used to plan runs, and for plug-in analysis for mtdna analysis. Torrent Variant Caller is a genetic variant caller for Ion Torrent sequencing platforms, and is specially optimized to exploit the underlying flow signal information in the statistical model to evaluate variants. Torrent Variant Caller is designed to call SNPs, multi-nucleotide polymorphisms (MNPs), insertions, deletions, and block substitutions. The HID SNP Genotyper plug-in is designed to be an integrated tool, providing streamlined analysis and reporting for the Precision ID Identity Panel and Ancestry Panel. It uses the Torrent Variant Caller to identify genotypes at specific hotspot locations and performs biogeographical ancestry prediction (Figure 8), Y lineage prediction, and random match probability (RMP) computation. Users have the flexibility to quickly read the called genotypes, evaluate the quality of the data using built-in quality metrics, and perform more data exploration with displayed tables, bar charts, and third-party applications such as NCBI resources and Integrated Genome Viewer (IGV). Additionally, the HID SNP Genotyper plug-in offers the ability to download a comprehensive analysis report and the bulk genotype data for further analysis. Figure 8. Variant call report from the Torrent Variant Caller plug-in. 11

Ordering information Product Quantity Cat. No. Precision ID NGS System instrumentation and software Ion S5 System, Ion Chef System, Converge 2.0 Software, NGS Analysis and Case Management software license 1 set A35984 Ion S5 XL System, Ion Chef System, Converge 2.0 Software, NGS Analysis and Case Management software license 1 set A35985 Converge 2.0 Software, NGS Analysis and Case Management software license, Precision ID GlobalFiler NGS STR starter kit 1 set A35986 Panels for human identification Precision ID GlobalFiler NGS STR Panel v2 (for Ion S5 Systems) 96 rxns A33114 Precision ID GlobalFiler NGS STR Panel (for Ion PGM System) 96 rxns A30939 Precision ID Identity Panel 96 rxns A25643 Precision ID Ancestry Panel 96 rxns A25642 Precision ID Identity and Library Kit Bundle 96 rxns A26808 Precision ID Ancestry and Library Kit Bundle 96 rxns A26807 Precision ID mtdna Whole Genome Panel 96 rxns A30938 Precision ID mtdna Control Region Panel 96 rxns A31443 Precision ID Library Kit 96 rxns A26435 Precision ID Library Kit 384 rxns A30941 Automated library preparation Precision ID DL8 Kit 32 rxns A33212 Sequencing kits and barcodes for multiplexing Ion S5 Precision ID Chef & Sequencing Kit (2 runs per initialization) 8 rxns A33208 Ion S5 Precision ID Chef & Sequencing Kit (1 run per initialization) 8 rxns A35850 Ion PGM Hi-Q STR Chef Kit 8 rxns A32743 Ion PGM Hi-Q STR Sequencing Kit 8 rxns A32745 Precision ID IonCode Barcode Adapters 1 96 Kit 1 kit A33586 Ion Xpress Barcode Adapters 1 96 Kit 40 rxns/bc 4474517 IonCode Barcode Adapters 1 384 Kit 3,840 rxns A29751 References 1. Kidd K et al. Better SNPs for better forensics: ancestry, phenotype, and family identification. Poster presented at the National Institute of Justice (NIJ) annual meeting, Arlington VA, June 2012. 2. Kosoy R, Nassir R, Tian C et al. (2009) Ancestry informative marker sets for determining continental origin and admixture proportions in common populations in America. Hum Mutat 30:69 78. 3. Karafet TM, Mendez FL, Meilerman MB et al. (2008) New binary polymorphisms reshape and increase resolution of the human Y chromosomal haplogroup tree. Genome Res 18:830 838. 4. Pakstis AJ, Speed WC, Fang R et al. (2010) SNPs for a universal individual identification panel. Hum Genet 127:315 324. 5. Phillips C, Fang R, Ballard D et al. (2007) Evaluation of the Genplex SNP typing system and a 49plex forensic marker panel. Forensic Sci Int Genet 1:180 185. Find out more at thermofisher.com/hid-ngs For Research, Forensic, or Paternity Use Only. Not for use in diagnostic procedures. 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Illumina and MiSeq are trademarks of Illumina, Inc. COL04583 0717