UL TEST REPORT AND PROCEDURE

Similar documents
UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Daniel Livingston

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA

Certificate of Compliance

MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

Certificate of Compliance

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

Certificate of Compliance

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC 61010_031C

Certificate of Compliance

If there are illegible images in this package, legible images may be found online via under My UL Reports/CDA.

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

QQGQ2.E Power Supplies, Information Technology Equipme... Business Equipment - Component

INSULATION GUARD MEG (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

SECTION to 5000 AMPERE PLUG-IN AND FEEDER BUSWAYS - SPECTRA. A. Low-Voltage Plug-in Busway to 5000 ampere, 600 VAC

SECTION LOW-VOLTAGE TRANSFORMERS

TEST REPORT IEC Information technology equipment Safety Part 22: Equipment to be installed outdoors

OPERATOR S INSTRUCTIONS

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA

TallSlateTM Grandee Installation Manual

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

SECTION AUTOMATIC TRANSFER SWITCH

Agilent 16048D Test Leads

Certificate of Compliance

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

Ref No: N Date: August 26, 2009

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SWITCHES FOR DOMESTIC & SIMILAR PURPOSE ACCORDING TO IS 3854:1997

MAY-16 REV B2

Laboratory Power Quality

Certificate of Compliance

International Standard Corresponding Indian Standard Degree of Equivalence

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

SPECIFICATION FOR FUSE DISTRIBUTION BOARD FOR COACHES. Revision

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SWITCH-SOCKET-OUTLETS (NON-INTERLOCK TYPE) ACCORDING TO IS 15787:2008

GUIDELINES FOR SUB-SYSTEM COMPLETION CERTIFICATES AND TEST RECORDS FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Agilent 16047D Test Fixture

Electromagnetic Compatibility Test Report. For. Calorique Ltd.

SERIES 800 / 810 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTER ASSEMBLIES

ELECTRICAL BULLETIN

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

SECTION BUSWAYS

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

INTERNATIONAL STANDARD

A. Section includes busway and fittings including plug-in units.

1 29SEP03 ALL General update with miscellaneous changes in entire document.

2. TEST RECORDS - All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau.

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

SPECIFICATION FOR APPROVAL

PD662 LOOP-POWERED METER Instruction Manual

ISO INTERNATIONAL STANDARD. Medical gas pipeline systems Part 2: Anaesthetic gas scavenging disposal systems

Insulated sheath power cable systems

TRI-COUNTY RURAL ELECTRIC COOPERATIVE, INC. Policy Bulletin No Appendix A SAFETY & INTERCONNECTION REQUIREMENTS FOR ALTERNATE ENERGY PRODUCTION

An Urgent Bulletin from CSA International

File E Project 00ME April 19, 2001 REPORT COMPONENT - INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 16, 2018

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers.

AS/NZS 3000: 2018 Changes to Wiring Rules Standard

Saphyr System Safety Guide for Saphyr P/N 60325


COMPILED BY APPROVED BY FUNCTIONAL RESP AUTHORISED BY V SINGH. Date: 16/03/2009. Date: 16/03/2009. Date: 19/03/2009 Date: 26/03/2009

RECOGNIZED COMPONENT Constructional Data Report (CDR)

Microgeneration Certification Scheme: MCS 006

Test Report No.: T EL Date: AUG 26, 2015 Page 1 of 5

Capital Projects Group Air Terminal Units Specification

Turbine Commissioning & Data Processing

SECTION BASIC ELECTRICAL REQUIREMENTS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Small Wind Turbine Electrical System Considerations

PD662 Loop-Powered Meter Instruction Manual

ATOMSCOPE HF200A. Operating Instruction Manual. Ver. 3.1

SECTION GROUNDING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MUSCO ENGINEERING ASSOCIATES Consulting Engineers

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

An Urgent Bulletin from CSA Group

MV Product Specifications

DOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING) B ADDRESS AND DETAILS OF THE INSTALLATION Address: SPECIMEN

HP Standard Supplier Requirements for Safe and Legal Products

Paragraph/ Figure/Table

Pre-installation Manual CONCEPT 301 D/401 D/501 D

DC/DC Converter PV200-27Bxx Series

ISO INTERNATIONAL STANDARD. Road vehicles Electrical and electronic equipment for a supply voltage of 42 V Electrical loads

Pre-commissioning Requirements for Independent Connection Providers Requiring New Assets to be Connected to the 11/6.6kV Network

Installation Address. Postcode. Purpose of the report This form to be used only for reporting on the condition of an existing installation.

Bulletin Grounding and bonding of solar photovoltaic systems Rules , , , and

1.1 All testing apparatus shall be periodically checked and calibrated. Records of such checks/calibration shall be maintained.

Chapter 2 Power Package Electrical Isolation Design

NPS/002/013 Technical Specification for Telephone and Pilot Cable Joints

Safety Screening of Health and Beauty Products -Massage devices

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENTS AND QUANTITIES

帝聞企業股份有限公司 DEE VAN ENTERPRISE CO., LTD. YS DSA-0421S Revision: A Date: 2005,12,06 S068 APPROVAL SHEET SWITCHING ADAPTER MODEL NO.

Transcription:

Issue Date: 2015-09-29 Page 1 of 14 Report Reference # E182560-V4-S20 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R) 2012 +A1:2012, C1: 2009/(R) 2012 + A2:2010/(R) 2012) Amendment 1 Revision Date 2012/08/21.CAN/CSA C22.2 No. 60601-1:14 Edition 3 Revision Date 2014/03. Certification Type: Component Recognition CCN: QQHM2, QQHM8 (Power Supplies, Medical and Dental) Product: Model: Rating: Switching Power Supply NPT42-M, NPT43-M, NPT44-M Input: 100-240Vac, 1.8A, 50/60Hz Input Power must be less than 74Watts. Model NPT42-M Output DC rating: +5Vdc, 8.0A MAX +12Vdc, 3.0A MAX -12Vdc, 0.7A MAX Model NPT43-M Output DC rating: +5Vdc, 8.0A MAX +15Vdc, 2.4A MAX -15Vdc, 0.7A MAX Model NPT44-M Output DC rating: +5Vdc, 8.0A MAX +24Vdc, 1.5A MAX +12Vdc, 0.7A MAX Maximum Output Power: 45W Convection Cooling 55W Forced Air Cooling Output derates 2.5% per degree from 50 deg C to 80 deg C. Applicant Name and Address: ASTEC INTERNATIONAL LTD - PHILIPPINE BRANCH 16TH FL LU PLAZA 2 WING YIP ST KWUN TONG KOWLOON HONG KONG This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Copyright 2012

Issue Date: 2015-09-29 Page 2 of 14 Report Reference # E182560-V4-S20 UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Ricky Wang / Clare He Reviewed by: Sammi Liang Copyright 2012

Issue Date: 2015-09-29 Page 3 of 14 Report Reference # E182560-V4-S20 Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Issue Date: 2015-09-29 Page 4 of 14 Report Reference # E182560-V4-S20 Product Description Models NPT42-M, NPT43-M and NPT44-M are an AC/DC switch mode power supply designed to deliver 45W rated output power during natural convection cooling and 55 W on forced air cooling. This equipment has been evaluated for use in Class I or Class II application. When the power supply is used as Class II equipment, all PE traces and components connected to PE on the primary side will be treated as primary part for spacing and insulation considerations. MOPP insulation was provided. Model Differences Models NPT43-M and NPT44-M are identical to model NPT42-M except secondary winding of Transformer T1 and secondary components for output rating. See Enclosure ILL 7-03 for details. Model NPT42-M: Loading Condition 1: (45W load with natural convection cooling) at 50 degc V1: +5V, 5A V2: +12V, 1.17A V3: -12V, 0.5A Loading Condition 2: (45W load with natural convection cooling) at 50 degc V1: +5V, 1.8A V2: +12V, 2.5A V3: -12V, 0.5A Loading Condition 2 tested at 75% load with natural convection cooling at 60 degc Loading Condition 2 tested at 50% load with natural convection cooling at 70 degc Loading Condition 2 tested at 25% load with natural convection cooling at 80 degc Loading Condition 3 : (55W load with 30CFM forced air cooling) at 50 degc; Set-up Condition B V1: +5V, 8A V2: +12V, 0.55A V3: -12V, 0.7A Loading Condition 4 : (55W load with 30CFM forced air cooling) at 50 degc; Set-up Condition B V1: +5V, 2.12A V2: +12V, 3A V3: -12V, 0.7A Loading Condition 3 (55W load with 30CFM forced air cooling) at 50 degc; tested using Set-up Condition D Loading Condition 3 (55W load with 30CFM forced air cooling) at 50 degc; tested using Set-up Condition A Loading Condition 3 (55W load with 30CFM forced air cooling) at 50 degc; tested using Set-up Condition C NPT43-M: Loading Condition 1: (45W load with natural convection cooling) at 50degC V1: +5V, 5A V2: +15V, 0.84A V3: -15V, 0.5A Loading Condition 2: (45W load with natural convection cooling) at 50degC V1: +5V, 1.5A V2: +15V, 2.0A

Issue Date: 2015-09-29 Page 5 of 14 Report Reference # E182560-V4-S20 V3: -15V, 0.5A Loading Condition 2 tested at 75% load with natural convection cooling at 60degC Loading Condition 2 tested at 50% load with natural convection cooling at 70degC Loading Condition 2 tested at 25% load with natural convection cooling at 80degC Loading Condition 3 : (55W load with 30CFM forced air cooling) at 50degC; Set-up Condition B V1: +5V, 8A V2: +15V, 0.3A V3: -15V, 0.7A Loading Condition 4 : (55W load with 30CFM forced air cooling) at 50degC; Set-up Condition B V1: +5V, 1.7A V2: +15V, 2.4A V3: -15V, 0.7A Loading Condition 3 (55W load with 30CFM forced air cooling) at 50degC; tested using Set-up Condition D Loading Condition 3 (55W load with 30CFM forced air cooling) at 50degC; tested using Set-up Condition A Loading Condition 3 (55W load with 30CFM forced air cooling) at 50degC; tested using Set-up Condition C NPT44-M: Loading Condition 1: (45W load with natural convection cooling) at 50degC V1: +5V, 5A V2: +24V, 0.59A V3: +12V, 0.5A Loading Condition 2: (45W load with natural convection cooling) at 50degC V1: +5V, 3A V2: +24V, 1A V3: +12V, 0.5A Loading Condition 2 tested at 75% load with natural convection cooling at 60degC Loading Condition 2 tested at 50% load with natural convection cooling at 70degC Loading Condition 2 tested at 25% load with natural convection cooling at 80degC Loading Condition 3 : (55W load with 30CFM forced air cooling) at 50degC; Set-up Condition B V1: +5V, 8A V2: +24V, 0.28A V3: +12V, 0.7A Loading Condition 4 : (55W load with 30CFM forced air cooling) at 50degC; Set-up Condition B V1: +5V, 2.12A V2: +24V, 1.5A V3: +12V, 0.7A Loading Condition 3 (55W load with 30CFM forced air cooling) at 50degC; tested using Set-up Condition D Loading Condition 3 (55W load with 30CFM forced air cooling) at 50degC; tested using Set-up Condition A Loading Condition 3 (55W load with 30CFM forced air cooling) at 50degC; tested using Set-up Condition C Note: Loading conditions are the output settings of the power supply during test. Loading conditions at the end-system may vary. However, it should not exceed the output ratings given (see "ratings" for details). Technical Considerations

Issue Date: 2015-09-29 Page 6 of 14 Report Reference # E182560-V4-S20 Classification of installation and use : Component to be installed in end-product Device type (component/sub-assembly/ equipment/ system) : Component Intended use (Including type of patient, application location) : Component - to be evaluated in end product Mode of operation : Continuous Supply connection : Input Connector Accessories and detachable parts included : None Other options include : None The product was investigated to the following additional standards:: AAMI ES60601-1 AMD 1 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE, AMENDMENTS - Edition 1 - Issue Date 2012/08/20CSA C22.2 NO. 60601-1:14 MEDICAL ELECTRICAL EQUIPMENT. PT. 1, GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - Edition 3 - Issue Date 2014/01/01 The product was not investigated to the following standards or clauses:: Electromagnetic Compatibility (IEC 60601-1-2), Clause 14, Programmable Electronic Systems, Biocompatibility (ISO 10993-1) The degree of protection against harmful ingress of water is:: Ordinary The product is suitable for use in the presence of a flammable anesthetics mixture with air or oxygen or with nitrous oxide:: No The product is Recognized only to the following hazards: Fire, Shock. Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The power supplies have been judged on the basis of the required creepage and clearances in the Standard for Medical Electrical Equipment, ANSI/AAMI ES 60601-1, Sub clause 8.9. This power supply has not been evaluated for patient connected applications. This power supply is a built-in device as part of medical equipment. The date of manufacture need to be evaluated in the end-product. Consideration should be given to measuring the temperature on power electronic components and transformer windings when the power supply is installed in the end-use equipment. Maximum rated operating temperature Tma ( C) is between 50 deg. C to 80 deg. C. Output derates 2.5% per degree from 50 deg C to 80 deg C. The transformers T1 incorporates a Class 155 (F) insulation system. The power supply was evaluated as 2 MOPP Insulation between Primary and Secondary, and as 1 MOPP Insulation between Primary and Earth. See insulation diagram for details. The max working voltage measured between transformer T1 of model NPT42-M Primary to Secondary: 266 V rms, 634 Vpk; between transformer T1 of model NPT43-M Primary to Secondary: 262.4 V rms, 557 Vpk; between transformer T1 of model NPT44-M Primary to Secondary: 274.7 V rms, 557 Vpk. The power supplies have not been evaluated for patient connected applications. Fuses F1 and F2 are not intended to be accessible by user. Final application to be determined in the

Issue Date: 2015-09-29 Page 7 of 14 Report Reference # E182560-V4-S20 end-product investigation (e.g., Fuse rating/marking are to be provided in the end use application.) Earthing test need to be conducted in end-product investigation. Leakage current test, Temperature test, marking test, and earth impedance test need to be repeated / considered in end-product investigation. Suitability for the PE tab to be used with quick-connect connector needs to be evaluated in endproduct. Instructions and equipment marking shall be provided in a language, which is acceptable in the country in which the equipment is to be installed. This power supply was tested on a 20 A branch circuit. If used on a branch circuit greater than this, additional testing may be necessary. The disconnection from the line must be in the end system. The insulation between accessible parts and live part must be re-evaluated in end product. The equipment has rated output of 45W when used with convection cooling, and rated output of 55W when used with 30CFM forced air cooling. Additional temperature test shall be further considered in end application. The necessity to add detailed information of force air cooling on the rating label according to Clause 7.2.15 shall also be considered in end application. End product Risk Management Process to include consideration of requirements specific to the Power Supply. End product Risk Management Process to consider the need for different orientations of installation during testing. End product to determine the acceptability of risk in conjunction to the movement of components as part of the power supply. End product to determine the acceptability of risk in conjunction to the routing of wires away from moving parts and sharp edges as part of the power supply. Temperature Test was conducted without Test Corner. End product to determine the acceptability of risk in conjunction to temperature testing without test corner as part of the power supply. End product Risk Management Process to consider the need for simultaneous fault condition testing. End product to determine the acceptability of risk in conjunction to the selection of components as it pertains to the intended use, essential performance, transport, storage conditions as part of the power supply. A suitable Electrical and Fire enclosure shall be provided in end product. This equipment has been evaluated for use in Class I or Class II application. When the power supply is used as Class II equipment, all PE traces and components connected to PE on the primary side will be treated as primary part for spacing and insulation considerations.