Primers and Top Seals

Similar documents
SYSTEM. decorative fire protection FOR ON-SITE & OFF-SITE APPLICATION. FOR STRUCTURAL STEEL external and internal use

30 & 60 MINUTES FIRE PROTECTION

Two hour fire protection can be acheived with just one coat in 24 hours instead of 7 days for conventional products.

FAST drying products for steel structures

Waterbased Range Protective coating solutions that cover your needs

PU Anti Graffiti Polyurethane Finish

Intumescent Fire Protection Solutions for Structural Steel

Binding protection at different levels

PRODUCT DATA SHEET Sika Unitherm Platinum

PRODUCT DATA SHEET Sika Unitherm Platinum-120

Property Test/Standard Description

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

HAMMERITE NO. 1 RUST BEATER PRIMER

This product contributes to the Green Buildings Standard credits. Please see section Green Building Standards. Property Test/Standard Description

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

PRODUCT DATA SHEET. Sika Unitherm Steel S exterior. (formerly Sika Unitherm exterior) PRODUCT DESCRIPTION

SIGMACOVER 350. Revision of February 2010 DESCRIPTION. two component high build polyamine cured epoxy primer/coating PRINCIPAL CHARACTERISTICS

General: Primarily designed for maintenance and repair. Only aluminium containing versions to be used in immersed environments.

Property Test/Standard Description

two component polyamide cured epoxy primer yellow/green (redbrown on request) - eggshell

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 25 C calculated IED (2010/75/EU) (theoretical)

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 30 C calculated VOC-USA / VOC Hong Kong EPA Method 24

two component polyamide cured epoxy primer yellow/green (redbrown on request) - eggshell

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

two component polyamide cured epoxy primer yellow/green - eggshell

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

METAL & MACHINERY PAINT POLYURETHANE FLOOR PAINT SKIP & CONTAINER PAINT

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 32 C VOC-USA / VOC Hong Kong EPA Method 24

Property Test/Standard Description

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C

Property Test/Standard Description. 53± 2 % matt (0-35) Flash point ISO 3679 Method 1 25 C calculated IED (2010/75/EU) (theoretical)

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description

SATIN NON-DRIP ACRYLIC

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

White, a range of ready-mixed colours, and colours from the Dulux Colour System

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 29 C IED (2010/75/EU) (calculated)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (30 C) calculated VOC-US/Hong Kong

high-performance coatings for commercial spaces.

SPECIALIST PRODUCTS. Leading edge solutions for specialist commercial applications. Innovative technology. Ultimate performance

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (32 C) calculated VOC-US/Hong Kong

Firesteel 47-4 and 47-4 EXT Product Data Sheet No. 375

SIGMAZINC 160. Revision of March 2007 DESCRIPTION. two component moisture curing inorganic zinc (ethyl) silicate primer PRINCIPAL CHARACTERISTICS

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

General: Primarily designed for maintenance and repair. In immersed environments Jotamastic 80 Aluminium is suitable.

Protective & Marine Coatings Europe, Middle East, Africa & India

Corrosion Protection. MIPA SE Am Oberen Moos 1 D Essenbach Tel.: /922-0 Fax: /

Sea~Barrier is the registered trademark of Altex Coatings Limited

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

ROCKGRIP UNIVERSAL ACRYLIC PVA

Protective: Recommended for offshore environments, refineries, power plants, bridges, buildings, mining equipment and general structural steel.

ACROLON 7300 High Solids Polyurethane

Property Test/Standard Description STANDARD GRADE

GULF COAST PAINT MFG., INC

Property Test/Standard Description

Property Test/Standard Description STANDARD GRADE

Protective: Recommended for refineries, power plants, bridges and buildings. Suitable for a wide range of industrial structures.

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (33 C) calculated VOC-US/Hong Kong

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Property Test/Standard Description

PRODUCT SELECTION GUIDE

Approved. Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong

NC Sanding Sealer Clear Clear Nitrocellulose Sanding Sealer

SIGMAZINC 158. Revision of September 2008 DESCRIPTION. two component moisture curing zinc (ethyl) silicate primer PRINCIPAL CHARACTERISTICS

Rust-Oleum Industrial Brands Specification

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

A range of automotive refinish ancillaries designed to deliver results.

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 35 C

Property Test/Standard Description

ZINGA. Physical data and technical information

A range of automotive refinish ancillaries designed to deliver results.

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

DP4101 / DP4104 / DP4107 HS PRIMER

ITW ROCOL METAL ENRICHED PAINTS

Rust-Oleum Industrial Brands Specification

E xpanding F ireproof Coat ings

Moisture curing paint systems. (Moisture Curing Urethanes) MCU

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

Refer to Substrates & Surface Preparation.

Property Test/Standard Description

Epoxy resin MIO + polyurethane

Marine: Exterior and interior areas, including outside hulls, superstructures, decks, cargo holds and water ballast tanks.

Property Test/Standard Description Solids by volume. ISO 3233 Gloss level (60 ) ISO 2813

Colourthane C-Series. Metal Coatings Guide

FIRETEX FX5090 For Onsite Fire Protection

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (28 C) VOC-USA / VOC Hong Kong EPA Method 24

Aliphatic Acrylic-Polyester Polyurethane

Property Test/Standard Description

Application Guide for Internal Flow Efficiency Coating Jotapipe FC 400

Date of issue: 5 October 2017 Page: 1/6

Transcription:

Smart Protection Primers and Top Seals High Performance Anti-Corrosion Primers and Decorative Top Seals for Structural Steelwork

At the Forefront of Smart Passive Fire Protection We are specialists, with one focus that has not and will not change to protect people and buildings from fire. For over 40 years, Nullifire has been a market leader in intumescent and fire stopping solutions. Passive fire protection is highly complex but crucially important, especially as buildings become more sophisticated. At Nullifire, we understand the need to have confidence in fire protection; so we provide systems that perform when they are called upon. Nullifire has always innovated, pioneering water-based coating technology and most recently the SC900 series, a fast-track intumescent coating that can save up to 60% on application and drying time. With a unique team of technical experts, everything is focused on providing what our customers need at every stage of their project - smart protection. Nullifire is a brand of tremco illbruck, a European manufacturer and service provider of high performance building materials. 2

Introduction Detail section of typical anti-corrosion coating system Steel Section Protective Primer Intumescent Basecoat Top Seal Combine Nullifire primers and top seals with Nullifire intumescent basecoats to provide a complete system for fire protection and then decoration of structural steel. All Nullifire products are tested for compatibility to minimise the risk of problems occurring on site. Primer Inhibits corrosion of the underlying structural steel. Primers also provide a key for the intumescent basecoat. If using SC901 or SC902, primers may not be required (contact our Technical Services Department helpline for more information prior to use). Intumescent Basecoat The intumescent coating is applied to the correct thickness to provide the specified level of fire protection. Nullifire leads the way in intumescent basecoat technology. Top Seal Smooth hardwearing finish to seal the basecoat, which protects from bumps, cuts and accidental damage. The decorative aspect of the top seal provides an aesthetically attractive appearance. It is recommend that Nullifire primers, basecoats, and top seals are applied by approved trained specialists such as Nullifire Premier Contractors. Full details of our approved contractors can be obtained by contacting us, or visit www.nullifire.com Which Primers are Suitable for My Installation? All of the Nullifire products listed are suitable for areas C1, C2 and C3. For areas of C4 and above, please contact us for technical advice. Remember that C1 and C2 areas may contain large kitchens or other areas of high humidity which may have to be regarded separately. C1: Very low corrosion risk C2: Low corrosion risk C3: Medium corrosion risk Interiors Heated buildings with clean atmospheres (e.g. offices, shops, schools, hotels). Exteriors n/a Interiors Unheated buildings where condensation may occur (e.g. depots, sports halls). Exteriors Atmospheres with low level of pollution. Mostly rural areas. Interiors Production rooms with high humidity and some air pollution (e.g. food-processing plants, laundries, breweries, dairies). Exteriors Urban and industrial atmospheres, moderate sulphur dioxide pollution, Coastal area with low salinity. For full product details, please see our website: www.nullifire.com 3

Choosing Primers and Top Seals Anti-Corrosion Primers Nullifire primers are designed to protect the surface of structural steel from corrosive attack. Nullifire primers also provide a suitable key onto which a Nullifire intumescent basecoat can be applied. Each Nullifire primer has been formulated to meet specific application conditions AND to be compatible with the Nullifire range of intumescent basecoats. It is important to use products that have been tested together for compatibility. This ensures that costly adhesion problems are avoided, allowing the fire protection process to run smoothly. Compatibility also guards against delamination of the coatings once installed which can be extremely expensive to rectify once construction has finished and the building is in use. Nullifire has tested all of its products within the range to avoid these issues, providing a high performance integrated system for all requirements from a single source. Application Easy to apply via conventional airless spray (normally recommended) Can be applied by roller or brush Decorative Top Seals Nullifire top seals provide an outstanding quality decorative finish. This is particularly useful where the steel work remains exposed as opposed to being hidden by false ceiling installations or boarded behind columns. Some top seals are available in a range of shades and colours. Top seals also provide a durable finish that can be cleaned by wiping with a damp cloth. All Nullifire top seals have been tested with Nullifire Basecoats to ensure compatibility and performance. Application Easy to apply via conventional airless spray (normally recommended) Can be applied by roller or brush 4

Anti-Corrosion Primers PM015 Two-Pack Aluminium Epoxy Primer PM015 provides an unequalled level of barrier protection and corrosion resistance on various steel types. Available in 20 L or 5 L kits Two-pack product Protects black steel, galvanised steel, and rusted steel Contains aluminium flakes to provide exceptional protection Long history of use in a number of industrial markets Self priming Corrosion protection with a single coat Low VOC Aluminium finish Substrate Black steel, galvanised steel, rusted steel Colours available Aluminium Finish Semi-gloss Preparation Grit blast steel to SA2 1/2 or equivalent. For galvanised steel, see TDS WFT 87-115 μm* DFT 75-100 μm* Drying times: @20 C touch dry 6 hours Drying times: @20 C full cure 3 days Over coating: @ 20 C 6 hours* Theoretical coverage 11.5 m²/l at 50 μm Thinners Cleaners * Maximum overcoating time depends on the basecoat. Please contact Nullifire for further information. PM018 Two-Pack Epoxy Primer Multi-purpose epoxy primer. The product is heavy duty and high build. Available in 20 L or 5 L kits Two-pack product Protects steel in corrosive environments Excellent at low temperatures Ideal for areas where there may be condensation Semi-gloss finish Very good abrasion resistance Available in RAL 9002 White/Grey Substrate Colours available Finish Preparation WFT DFT Drying times: @ 20 C touch dry Drying times: @ 20 C full cure Over coating: @ 20 C Theoretical coverage Thinners Cleaners Black steel RAL 9002 White/Grey Semi-gloss Hand clean/power tool or UHP water jet rig, see TDS Normally 205 μm, see TDS Normally 175 μm, see TDS 4 hours 7 days 4 hours 8.6 m²/l at 100 μm Note: all primer drying times depend on film thickness, temperature, ventilation and local site conditions. For full product details, please see our website: www.nullifire.com 5

Anti-Corrosion Primers PM019 Anti-Corrosion Transport Primer Protects steel for up to three months prior to transportation onto site and over coating with a Nullifire basecoat. Available in 20 L kits Two-pack product Provides steel with up to three months protection prior to coating Steel can be moved whilst protected Steel can be stored outdoors Excellent tie coat for SC901 and SC902 Can be used as general primer Fast drying Red or Grey Substrate Colours available Finish Preparation WFT DFT Drying times: @ 20 C touch dry Drying times: @ 20 C full cure Over coating: @ 20 C Theoretical coverage Thinners Cleaners Black steel, galvanised steel Red/Grey Matt Grit blast steel to SA2 1/2 or equivalent. For galvanised steel, see TDS 110 μm, see TDS 30 μm, see TDS 16 hours 3 days 8 hours 9.3 m²/l at 30 μm PM020 Single-pack Alkyd High Build Primer A single-pack solution that is well suited to production shops or sites that need fast cure to dry and handling times. Available in 20 L kits Single-pack product Single pack Fast drying primer Compatible with all Nullifire Basecoats except the SC900 series Good filling properties on rough or pitted steel Easily sprayed with both airless and conventional equipment Traditional red colour Substrate Colours available Finish Preparation WFT DFT Drying times: @ 20 C touch dry Drying times: @ 20 C full cure Over coating: @ 20 C Theoretical coverage Thinners Cleaners Black steel Red Matt Grit blast steel to SA2 1/2 or equivalent, see TDS 68-98 μm, see TDS 35-50 μm, see TDS 20 minutes 3 days 8 hours (min.) 11.0 m²/l at 50 μm FC0010 or FC010 6 For full product details, please see our website: www.nullifire.com

PM021 Two-Pack Epoxy Polyamide Primer A two-pack general purpose inhibitive primer that chemically reacts with the steelwork to create a corrosion resistant surface. Available in 20 L kits Two-pack product General purpose primer Compatible with all Nullifire Basecoats Excellent corrosion resistance Can be used as a tie coat when diluted, see TDS Flat finish Grey Substrate Colours available Finish Preparation WFT DFT Drying times: @ 20 C touch dry Drying times: @ 20 C full cure Over coating: @ 20 C Theoretical coverage Thinners Cleaners Black steel Grey Matt Hand clean/power tool or UHP water jet rig, see TDS 100-300 μm, see TDS 50-150 μm, see TDS 90 minutes 12 days 12 hours 10.4 m²/l at 50 μm Note: all primer drying times depend on film thickness, temperature, ventilation and local site conditions. 7

Decorative Top Seals TS134 Two-Pack Acrylic Polyurethane Top Seal Available in 20 L or 5 L kits Two-pack product High gloss solid finish Available in a range of RAL colours Suitable for on-site or off-site application Excellent abrasion resistance Excellent resistance to weathering Easily sprayed with both airless and conventional equipment VOC compliant to current AIM regulations Basecoat Colours available Finish Preparation WFT DFT Drying times: @ 20 C touch dry Drying times: @ 20 C full cure Over coating: @ 20 C Theoretical coverage Thinners Cleaners SC901, SC902, SC801, SC802, S707, S708, S605, S606 White and limited RAL colours High gloss Apply to clean dry basecoat 115 μm 75 μm 4 hours 3 days 12 hours 8.6 m²/l at 75 μm FC025 - spray, FC215 - roller 8 For full product details, please see our website: www.nullifire.com

TS815 Single-pack Modified Acrylic Top Seal Available in 10 L packs Single-pack product Single-pack product Gloss finish Available in White and limited RAL colours Suitable for on-site or off-site application Fast drying Easily sprayed with both airless and conventional equipment VOC compliant to current AIM regulations Basecoat SC801, SC802, S707, S708, S605, S606 TS816 Single-pack Water-Based Acrylic Top Seal Single-pack, water-based acrylic top seal Attractive soft sheen washable finish Good abrasion resistance Easy application and excellent coverage Environmentally friendly with low odour Available in a limited range of RAL colours Available in 20 L packs Single-pack product Basecoat SC801, SC802, S707, S708, S605, S606 Note: all top seal drying times depend on film thickness, temperature, ventilation and local site conditions. For full product details, please see our website: www.nullifire.com 9

Compatibility Tables Key Can use Not approved Contact us for details Intumescent basecoat Nullifire Primers SC900 series basecoat Water-based basecoat Solvent-based basecoat Product reference Pack Pack size System type SC901 SC902 S707 SC801 SC802 S708 S605 S606 Tech ETA Tech ETA Tech ETA Tech Tech Tech Tech Tech PM015 Two 5 L, 20 L Aluminium epoxy primer PM018 Two 20 L Epoxyprimer PM019 Two 20 L PM020 Single 5 L, 20 L PM021 Two 20 L Epoxy anti-corrosive shop primer Alkyd high build primer Epoxy polyamide primer No primer required under certain conditions (refer to Technical) Tech = Technical Approval ETA = European Technical Assessment Intumescent basecoat Nullifire Top Seals SC900 series basecoat Water-based basecoat Solvent-based basecoat Product reference Pack Pack size System type SC901 SC902 S707 SC801 SC802 S708 S605 S606 Tech ETA Tech ETA Tech ETA Tech ETA Tech ETA Tech Tech Tech TS134 Two 5 L, 20 L Acrylic polyurethane TS815 Single 10 L Modified acrylic TS816 Single 5 L, 20 L Water based acrylic No top seal required under certain conditions (refer to Technical) Tech = Technical Approval ETA = European Technical Assessment. An ETA approved top seal is available from Nullifire but please contact us for details. 10 For full product details, please see our website: www.nullifire.com

Thinners and Cleaners With high performance, integrated primer, basecoat and top seal systems, it is important that no one element is degenerated, causing the possible failure of the system. With this in mind, Nullifire have developed a range of thinners and cleaners suitable for their systems. These products are specially formulated, taking into account the active ingredients of the products with which they are combined, so as not to lessen the functionality of the coating, and give maximum performance. A list of compatible thinners and cleaners is included in the product data tables in this brochure. Failure to use the correct thinner or cleaner as specified in the appropriate Nullifire technical data sheet could result in the non-performance of the products and the voiding of any product warranties, specific or implied. For more information on thinners and cleaners, please contact our Technical Services Department. Cleaner 25 L packs Thinner 5 L tins For full product details, please see our website: www.nullifire.com 11

tremco illbruck Limited Coupland Road, Hindley Green Wigan WN2 4HT UK T. +44 (0) 1942 251400 F. +44 (0) 1942 251410 protect@nullifire.com www.nullifire.com 2017-02 v3