Busbar Joint Covers Low Voltage Switchboard Equipment

Similar documents
Pre-Insulated Busbars

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

Maharashtra State Electricity Distribution Company Limited. SPECIFICATION NO. MMC: MSC-II/Multi Meter box/smc/2018/10 TECHNICAL SPECIFICATION FOR

Standard Pole Range 5. In-Ground Mounted 6. Ground Line Protection 6. Base Plate Mounted 6. Quality & Design Standards 7. Quality Standard 7

SECTION EARTHING AND EARTH FAULT PROTECTION

SECTION GROUNDING

BUILDER S CONSTRUCTION SUPPLIES (Temporary in permanent position) REQUIREMENTS. March 2014

*** Supercedes: BECO E and COM , , & ***

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

PART 7 Technical Specification for Overhead and Underground Service Connection works for the Year

Accreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan.

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

ALCO Cable Gland Tutorial

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

MATERIAL STANDARD FOR CABLES AND WIRES

CONTENTS. B. System Design and Performance Requirements

CHAPTER 5 METERING REQUIREMENTS

TENDER NO. PGVCL/PROC/HT SMC Meter Box/872

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

CONSTRUCTION SPECIFICATION FOR GROUNDING

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

SECTION INSULATED WIRE AND CABLE

AS/NZS 2280:2012 AS/NZS

Electric Service Handbook

overhead and underground power equipment ISSUE 28 AUGUST / SEPTEMBER 2013 / OHUG.COM OHUG WINS BEST TRADE STAND AT EEA FOR THE SECOND YEAR IN A ROW!

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS :2009

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Termco Heatshrink.

EXPLOSION-PROOF CABLE GLAND - Type ICG 623 Manual

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

Technical Specification for Insulated Low Voltage Single Core Copper Cable

PARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION

PRODUCT INFORMATION Dero Hoop Rack

INDEX. Page SECTION 1.0: SCOPE Toronto Hydro Requirements Ontario Electrical Safety Code 1 SECTION 2.0: PURPOSE 1

CS-21 STREET STRUCTURES TABLE OF CONTENTS

TECHNICAL SPECIFICATION

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Pharmacy REGISTRATION BOARD of Western Australia (A.B.N )

Chapter 14 - Air Sealing

Addendum - 2 for 11KV VCB Panel Specifications GETCO / E / TS HTPB 5401 / R1 Dt and GETCO / E / TS HTPB 5402 / R1 Dt

Subject: Guidance on Corrosion Assessment of Ex Equipment

Addendum. Installing the Fiberglass Trench Liner Sensor. Installation Hardware. Installation Requirements. Sensor-to-Console Wiring.

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

TECHNICAL SPECIFICATIONS

ELECTRICAL SAFETY INSPECTION REPORT

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

CONSTRUCTION SPECIFICATION FOR ERECTION OF POLES

Technical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables

FIBRE GLASS CROSS ARMS FOR 33 KV LINES

TECHNICAL SPECIFICATION FOR SMC LT AMR METER BOXES MANUFACTURED FROM THERMOSETTING PLASTIC 1.0 SCOPE:

Technical Specification for Galvanised Fabricated Steelwork

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

Access. Step Iron. Designed and Manufactured in Australia

TECHNICAL SPECIFICATION FOR 3-PH SMC BOXES MADE FROM THERMOSETTING PLASTIC FOR 3-PH ENERGY METER.

SECTION RACEWAYS

PVC Stub Flanges & Backing Rings

DATA SHEET Single Core 2HR Fire Rated Cable

Technical Specification for Helical Fittings for Overhead Power Lines

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 5, 2018

Special Provision No. 999S19 March Pancake Bridge Deck Anodes, Junction Box Entry and Acceptance Testing of Cathodic Protection System

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

PinkWood Ltd. Revised September 29, 2017

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POLES

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails.

SafeX110 Single Core Flexible Tinned Copper Cable

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

3M Cold Shrink Joint, SC145-II/SS145-II

AUTOMOBILES POWER SWITCHGEAR HARDWARE & TOOLS.

Boise Cascade Company Revised June 25, 2018

SIS Solid Insulation System

Submit shop drawings in accordance with Vale Specification SPEC

SPECIFICATION FOR SIMPLEX SWITCHBOARDS

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

P.V.C. INSULATED UNARMOURED COPPER CABLES

SECTION BUSWAYS

INFORMATION PROVIDED TO ASSIST THE TENDERER FOR THE SUPPLY OF:

ELECTRICAL SAFETY INSPECTION REPORT

AS Certified ALCADEX

National Construction Code Series (NCC) Building Code of Australia (BCA)

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT

EIU 105 Types of Non-Electrical Insulation Materials

SECTION GYPSUM BOARD

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

1. Hangers and supports for electrical equipment and systems.

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

CERTIFICATE OF ACCREDITATION

Transcription:

Busbar Joint Covers Low Voltage Switchboard Equipment Publication JC 2010

Contents Descriptive 1 Use Description Technical 2 Compliance to Standards Insulation Flammability/Fire Hazard Material Details Installation 3-4 Dimensions 5 Since product improvement is a continuing policy, we reserve the right to change specifications without notice.

Descriptive KENTAN BUSBAR JOINT COVERS solve the problem of insulating the connections in insulated busbar systems. Busbar connections are most commonly insulated (when specified) by: Insulation Tape. Tape is not allowed for this purpose according to clause 7.4.2.1 of AS/NZS 3439.1: 2002. In addition to this, tape is often not replaced after maintenance of the connection. Appearance is untidy. Heat Shrink Sleeving (Held in place by cable ties etc) Often not replaced after maintenance of the connection. Very untidy appearance. Liquid Formulations (Paints, varnishes etc.) These are not allowed by the standard. Inspection and maintenance of the connection is discouraged, especially if the material is difficult to remove. Epoxy Moulding. Acceptable, but prevents access to the connection. The KENTAN BUSBAR JOINT COVERS: - Are specifically designed for purpose. - The two halves of the cover are held together by screws to give access to the joint and easy replacement for inspection and maintenance - When used with the KENTAN BUSBAR SLEEVING (refer to Publication BI2010) a completely insulated busbar system, without additional forms of separation is achievable. - May be used with other types of busbar insulation such as heat shrink sleeving. - Fully complies Description JOINT COVERS are available in several sizes, each with 2 depths. The covers are made from pliable injection moulded PVC compound, not less than 1.6mm thick. The two halves making up one cover are held together by screws supplied and chosen by the switchboard builder. Holes are moulded into the external flange for this purpose. Busbar entries are made by cutting the covers to suit. 1

Technical Compliance to Standards The covers comply with the following clauses of AS/NZS 3439.1 : 2002 7.4.2.1 Protection by insulation of live parts - Live parts shall be completely covered with insulation which can only be removed by destruction or by use of a tool. - Flame retarded PVC, 1.6mm thick Used with the BUSBAR SLEEVING, the insulation system can be classified as a busbar enclosure (separation of busbars from functional units) as per clause 7.7.2.2 Insulation Clause 8.2.2.2 Testing of enclosures made of insulating material. Test Voltage 3500V x 1.5 = 5250V AC Rated Insulation Voltage 1500V Flammability / Fire Hazard The sleeving has been tested to AS/NZS 606952.11 : 2001 and complies to Glow-wire flammability rating of 960 C Material Details Product name PVC Compound (lead free) Grade F188C02 Standards Complies with AS/NZS 3802 : 2000 for V90HT Insulation and SV90 Sheathing. Flammability Self extinguishing 2

Installation Select the size of cover to suit the connection Mark the areas to be cut. (A white ink marker is recommended) Cut using a knife. (Placing the cover over a piece of wood makes handling easier) Place over the busbar connection. (For single bars only cutting one half of the cover is necessary.) Fix halves together using M6 hardware. (M6 x 16 nylon bolts and nuts recommended.) 3

Installation Typical rear sections of switchboards showing busbars insulated by rigid sleeving and busbar joint covers. Picture by kind permission NILSEN ELECTRIC (WA) Picture by kind permission SRS COMCELL SWITCHBOARDS 4

Installation A B C 90 90 135 135 170 170 25 45 30 50 30 50 A B C 200 100 30 50 5

KENTAN ENGINEERING A.B.N. 21 009 217 654 Unit 3, 8 Carole Road MADDINGTON Western Australia 6109 P.O. Box 284 MADDINGTON Western Australia 6989 International Telephone: 61 8 9493 5255 National Telephone: (08) 9493 5255 Facsimile: (08) 9493 5242 Email: sales@kentan.com.au Internet: www.kentan.com.au Kentan Engineering is a Quality Assured Company