dura. joint PVC waterstops

Similar documents
MasterPren PVC Waterstops

t e c h n i c a l d a t a s h e e t t e c h n i c a l d a t a s h e e t t e c h n i c a l d a t a s h e e t

CHARACTERISTICS / ADVANTAGES

MasterSeal 940. Centrally and externally placed PVC Waterstops

Construction. Flexible PVC waterstops. Product Description. Product Data. Tests. Form. Storage. Technical Data

PVC profile waterstops for joint sealing

According German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing

Sika KAB combination joint waterbars waterstopping systems

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

SUPERSWELL 47B HYDROPHILIC BUTYL WATERSTOP SEAL

TECHNICAL SPECIFICATION

Visqueen Gas Barrier STRUCTURAL WATERPROOFING AND GAS PROTECTION SYSTEMS. CE Mark to EN 13967

Section Pre-Applied Sheet Membrane Waterproofing

Sealing profiles which swell in contact with water.

PVC profile waterstops for joint sealing

SECTION CONCRETE ACCESSORIES

PRODUCT DATA SHEET SikaProof Bentonite

TS 2 SOUTH AUSTRALIAN WATER CORPORATION

Sealing profiles which swell in contact with water.

ITEM 435 ELASTOMERIC MATERIALS

Sika Waterbars - Tricomer Clamped Type

GUARANTEED ASPHALT LIMITED

VYNON PVC Waterstops

A. Texas Department of Transportation 2004 Standard Specifications for Construction and Maintenance of Highways, Streets and Bridges (TxDOT).

Preventing Water Leakage through Construction Joints using SYNKOFLEX Preformed Compressible Waterstop

Construction. Hydrophilic, swellable hose for sealing construction joints in watertight structures. (formerly Sika Injectoflex HPM)

Product Data Sheet SikaFuko Swell-1 Positioning Description Uses Advantages Approval / Standards Construction Product Data Packaging

SECTION RESILIENT SHEET FLOORING

WATERPROOF SYSTEM. The most site friendly ACTIVE SYSTEM below grade waterproofing system to date!

PRODUCT DATA SHEET SikaProof A

PRODUCT DATA SHEET. SikaProof A

Pre-applied waterproofing

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description.

220 E. General Robinson St. Pittsburgh, PA fax

PREPRUFE 300R LT & 160R LT

PRODUCT DATA SHEET. Product Description

DAVID BALL HYDROPHILIC WATERSTOPS HDBR WATERBAR

Sika Tricomer Compression Seals

CVO/169897A OCTOBER 29, CONCRETE JOINTS

Crystoflex Max comprising of a liquid component of selected polymers and a powder component of selected cements, fillers and aggregates.

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

Applications. Properties. Swelling capacity in contact with water. Density. Weight

WATERPROOFING SIKAPLAN MEMBRANE SYSTEMS FOR BASEMENTS TECHNOLOGY & CONCEPTS

Swellable joint sealing profiles

WATERSTOP - BUILDING JOINTS

Injection Systems for Concrete Structures. Causes, Remedies and Repairs

PRODUCT DATA SHEET. Product Description

High Performance DPM. Installation. Technical Support: LAST UPDATED: Page 1 CE Mark to EN 13967

Agrément Certificate 17/5450 website: Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW

Pre-applied waterproofing membranes that bond integrally to poured concrete for use below slabs or behind basement walls on confined sites

INFRASTRUCTURE TECHNOLOGIES

dura. fibre CFP adhesive

S u b s t r u c t u r e W a t e r p r o o f i n g - Membranes.

Sika Hydrotite CJ K

26 Visqueen 100% Recycled Ecomembrane 28 Visqueen DPM To Pifa Standard PROOF. membranes

SIKAPROOF BENTONITE SYSTEM. Product. Scope. Building Regulations BELOW GROUND WATERPROOFING. Appraisal No. 612 [2017]

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

Zemdrain. Technical Information. Technical & Fixing Guidelines TECHNICAL GUIDELINES

PREPRUFE Plus Low Temperature Membranes

FLOORWORX SELF LEVELLING SCREED PRODUCT DATA_

03250/VIN BuyLine 0622

TECHNICAL DESIGN AND INSTALLATION GUIDE THE COMPLETE ENGINEERED SOLUTION FOR TEMPORARY MOVEMENT JOINTS

4.16. APPLICATION INSTRUCTIONS Construction Joints & Details

GRACE CONSTRUCTION PRODUCTS HYDROPHILIC WATERSTOPS ADCOR 500S

Visqueen High Performance Radon

MASTERFLEX 900-FUKO Injection System

KIM Best Practices Guide for Shotcrete Nov 2013

THOROSEAL CPB 1. Capillary/Crystallising waterproofing, surface applied slurry for use on concrete and mortar. Description of product. Benefits.

NDC POLIPAK MEMBRANES

Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller

Waterproofing Products for UNDERGROUND STRUCTURES

SikaProof A. Fully bonded FPO sheet membrane waterproofing system for basements and other below ground structures. Product Description

This section applies to the design and installation of cast-in-place concrete, shotcrete, precast concrete, and post-tensioned concrete.

Stremaform. Formwork elements. Edition International

WATERPROOF X 1 INJECTION HOSE SYSTEM

RETAINING WALL. How to Waterproof Block Walls MATERIALS:

Sheetseal 226 RIW. Sheetseal 226

SECTION CONCRETE FORMWORK AND ACCESSORIES

Sealing strips for concrete construction joints STOPO TYPE 3 catalog

Student Services & Classroom Addition

PREPRUFE 300R Plus & 160R Plus

Jointing for KIM Shotcrete Walls Property of Kryton International Inc.

Floor Insulation Underlayment Section Sound Control Matting

Construction. Injectable hose for sealing construction joints in watertight structures. Product Description. Product Data. Tests.

COVERFLEX TWO-PART ELASTOPLASTIC CEMENT MORTAR FOR WATERPROOFING APPLICABLE WITH ROLL, BRUSH OR TROWEL. DESCRIPTION FIELDS OF APPLICATION

EUROTEAM. EUROTEK TK joint tape Polysulphide joint tape for building construction. construction chemicals

WARMFLOOR. Installation Guide.

ENKASONIC FLOOR UNDERLAYMENT 9110

METHOD STATEMENT Sika Drain-850 Geo

Decorative Epoxy Surfacing System

CRD C Certified PVC Waterstops for Concrete

PVC WATERSTOPS. TYPES OF CONCRETE JOINTS Expansion (Isolation) Joint. Contraction (Control) Joint

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

Sealing products. The new Generation of sealing-products

CONSTRUCTION SPECIFICATION FOR CONCRETE ROAD BASE

VISQUEEN RADON MEMBRANE SYSTEM

SYSTEM 500 NEWTON. System 400 NEWTON 403 HYDROBOND Externally Applied Waterproofing Membrane DATA SHEET MSDS INSTALLATION MANUAL

COUNTY OF BEXAR. Curbed Streets. Residential PUBLIC WORKS DEPARTMENT

Krystol Internal Membrane (KIM ) Guidelines and Procedures - NZ

PRODUCT MANUAL WATERSTOP-RX EXPANDING CONCRETE JOINT WATERSTOP.

Transcription:

a.b.e. Construction Chemicals dura. joint PVC waterstops Polyvinyl Chloride RANGE OF EXTERNALLY AND CENTRALLY PLACED WATERSTOPS DESCRIPTION The dura. joint waterstop range is extruded from specially formulated PVC material, which whilst flexible is easily welded on site to provide the primary seal in the waterproofing of water retaining and/or water excluding structures. USES The prevention of regress or ingress of water or liquids through construction or expansion joints in water retaining or excluding structures such as: Dams, reservoirs, digesters, water towers, canals. Basements, car parks, retaining walls. ADVANTAGES Co-ordinated profiles Ensures bulb continuity throughout the network. Making on site jointing simpler. Allows for jointing of external to centrally placed sections. Allows for jointing of expansion joint section to construction joint section. Flat top to centre bulb ensures snug fit of filler board. RANGE Expansion joint centrally placed dura. joint PVC centre bulb 150 mm dura. joint PVC centre bulb 200 mm dura. joint PVC centre bulb 250 mm Expansion joint externally placed dura. joint PVC external E 150 mm dura. joint PVC external E 200 mm dura. joint PVC external E 250 mm Construction joint centrally placed dura. joint PVC dumbell 150 mm dura. joint PVC dumbell 200 mm dura. joint PVC dumbell 250 mm Construction joint externally placed dura. joint PVC external C 150 mm dura. joint PVC external C 200 mm dura. joint PVC external C 250 mm In addition, factory made intersections are available for the full range: - Mitre on flat - 3-way on flat - 4-way on flat - T-piece - 90º on edge - 270º on edge All these sections can be made for both similar and dissimilar sections. All intersections should be factory produced by a.b.e. Construction Chemicals to minimize site joints. Form Colour Joint movement Hydrostatic head Tensile strength PHYSICAL PROPERTIES Extruded thermoplastic PVC sections Blue Up to 10 mm Up to 10 m head > 14 MPa Elongation at break > 300% DESIGN CRITERIA The choice of the width and thickness of waterstop is largely governed by concrete thickness, the position of the reinforcement, aggregate size and complexity of the pour. In general the 250 mm width of waterstop is suited to wall thicknesses of 250 mm and over. For concrete less than 250 mm thick, the use of a narrower waterstop approximating to the wall thickness will be appropriate. 150mm and 200mm profiles are available for this purpose.

INSTALLATION TECHNIQUES Centrally placed waterstops dura. joint CB and dumbell (DB) - are to be fully tied to the re-bar to eliminate possible displacement during the concreting and vibrating process. It is imperative that care is taken to fully compact the concrete around the waterstop in order to eliminate any voids or honeycombing in that area. Externally placed waterstops When used on ground slabs where the waterstop is supported on blinding, dura. joint external E and external C profiles usually require no fixing. Lay the waterstop centrally over the line of the joint to be formed. Fixing to vertical shuttering is done by nailing through the outer nailing flanges leaving the head of the nail proud so that it is held in the cured concrete. This prevents the waterstop being displaced when the shuttering is struck. SITE JOINTING Only butt joints should be welded on site. Special functionmade intersections are available from a.b.e. Construction Chemicals. The ends of the butt joints must be cut square. These cut ends should then be pushed against the preheated heater blade (supplied by a.b.e. ) until a molten bead appears against the blade. Remove the blade and firmly press the two molten ends of the waterstop together and hold firmly until these ends are fused together. A piece of shutterboard or similar material placed under the joint prior to the operation will facilitate the jointing. This jointing must be undertaken in a well-ventilated area as the fumes given off when the PVC is being melted are an irritant to the lungs and eyes. In enclosed areas forced ventilation is a prerequisite. A wire brush is used to clean the PVC residue on the heater blade after every jointing operation. MODEL SPECIFICATION Waterstop dura. joint external C. Externally placed waterstop for construction and contraction joints in walls and floors to water retaining and water excluding structures. The waterstop will be dura. joint external C, an externally placed extruded plasticized PVC compound applied in accordance with the recommendations of a.b.e. Construction Chemicals. The waterstop will comply with the requirements of CKS 389:1973 and have an elongation at break of 300% Waterstop dura. joint dumbell. A centrally placed waterstop for construction and contraction joints in walls and floors to water retaining and water excluding structures. The waterstop will be dura. joint dumbell, a centrally placed extruded plasticized PVC compound applied in accordance with the recommendations of a.b.e. Construction Chemicals. The waterstop will comply with the requirements of CKS 389:1973 and have an elongation at break of 300%. Waterstop dura. joint external E Externally placed waterstop for expansion joints in walls and floors to water retaining / water excluding structures. The waterstop will be dura. joint external E, an externally placed extruded plasticized PVC compound applied in accordance with the recommendations of a.b.e. Construction Chemicals. The waterstop will comply with the requirements of CKS 389:1973 and have an elongation at break of 300%. Waterstop dura. joint centre bulb Centrally placed waterstop for expansion joints in walls and floors to water retaining and water excluding structures. The waterstop will be dura. joint centre bulb, an externally placed extruded plasticized PVC compound applied in accordance with the recommendations of a.b.e. HEALTH & SAFETY Always carry out the jointing of dura. joint PVC waterstops in a well ventilated area as the fumes given off are an irritant to both eyes and lungs. In confined areas forced ventilation is a prerequisite. IMPORTANT NOTE This data sheet is issued as a guide to the use of the product(s) concerned. Whilst a.b.e. Construction Chemicals endeavours to ensure that any advice, recommendation, specification or information is accurate and correct, the company cannot - because a.b.e. has no direct or continuous control over where and how a.b.e. products are applied -accept any liability either directly or indirectly arising from the use of a.b.e. products, whether or not in accordance with any advice, specification, recommendation or information given by the company. FURTHER INFORMATION Where other products are to be used in conjunction with this material, the relevant technical data sheets should be consulted to determine total requirements. a.b.e. Construction Chemicals has a wealth of technical and practical experience built up over years in the company s pursuit of excellence in building and construction technology.

ESTIMATING Section width Approximate mass per roll Minimum radii on flat Minimum radii on edge Roll length dura. joint mm kg m m m dura. joint CB 250 32,2 15 0,15 15 dura. joint CB 200 25,8 14 0,15 15 dura. joint CB 150 39,6 12 0,075 30 dura. joint dumbell 250 30,8 15 0,15 15 dura. joint dumbell 200 24,8 14 0,15 15 dura. joint dumbell 150 36,8 12 0,075 30 dura. joint external C 250 35,5 10 0,15 15 dura. joint external C 200 27,8 9 0,15 15 dura. joint external C 150 39,5 8 0,075 30 dura. joint external E 250 38,7 10 5,0 15 dura. joint external E 200 30,4 9 5,0 15 dura. joint external E 150 43,4 8 5,0 30 dura. joint CB10 250 65,3 15 0,23 15 STANDARD PROFILES dura. joint PVC external E dura. joint PVC external C

STANDARD PROFILES dura. joint PVC dumbell dura. joint PVC centrebulb STANDARD INTERSECTIONS

TYPICAL DETAILS