Analysis of Distributed Energy Supplying Technologies From the Viewpoint of Waste Heat

Similar documents
ENERGY EVALUATION BY SIMULATION FOR EFFECTIVE USE OF SEWAGE HEAT

1. Heat Pumps contribute to Environmental Protection and Energy Security Heat Pumps Ambient Heat 23.5 Recycling Grid electricity + Heat pump

Explanation of JCM Feasibility Study in Thailand & Applicable Low CO2 Emission Technology

EVALUATION OF THE IMPACT OF NEW RESIDENTIAL WATER HEATER DISSEMINATION BY A RESIDENTIAL ENERGY END-USE MODEL

Japanese Energy Efficient Technologies

Development of 1MW high efficiency gas engine cogeneration system

ROLE OF ENERGY SUPPLIER FOR HEAT PUMP DEPLOYMENT

Hirose Yukinobu, HPTCJ 20 June 2016

IMPROVEMENT IN THE EFFICIENCY OF DISTRICT HEATING AND COOLING (DHC) WITH A REGIONAL STEAM NETWORK OF CHPs AND MUNICIPAL INCINERATION PLANTS IN TOKYO

Aiming for the Realization of a Low- Carbon Society through Natural Gas

Distributed Energy System - pooling heat and power -

District cooling/heating systems in China: Challenges and Opportunities

Country Report - City Gas Industry in Japan -

Evaluation of reduced energy use resulting from a DHC network in the Shinjuku DHC area

Tomohiko Ihara *, Yutaka Genchi National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan

December 13, 2012 Energy Efficient Cooling Information Service Webinar Series Christine Brinker and Gearoid Foley CHP with Absorption Chilling

24th World Gas Conference ARGENTINA WOC 5.1: Industrial Utilisation CHP - Sharing on Gas District Cooling (GDC) in Malaysia

POTENTIAL FOR THE ENERGY EFFICIENCY ADVANCEMENT IN DISTRICT HEATING AND COOLING PLANT BY RENOVATION

ImprovIng energy efficiency with chp: how to evaluate potential cost savings

Japan s s Initiatives in Combating Global Warming Japan s goals under the Kyoto Protocol: Reduce greenhouse gas emissions by 6% compared to 1990 Gover

Energy Efficiency in Buildings & End-use Electric Technologies

Tokyo Gas and Panasonic to Launch New Improved Ene-Farm Home Fuel Cell with World-Highest *1 Generation Efficiency at More Affordable Price

A Fundamental Study for Designing a Safe and Eco-friendly Community

Discussions about the Role of Nuclear Power for Achieving the Paris Agreement in Japan

Turbine Inlet Cooling. A Valuable Tool to INCREASE Electric Energy Production

MARKAL Analysis on Long-term Change of Residential Energy Equipment Structure in Japan

Development of Residential PEFC Cogeneration System in Osaka Gas

Research on Green Energy Technology for the Innovation Park of Wuhan National Bioindustry Base

Effect of Evaporative Cooling Techniques (Sprayed Water Mist) on Reducing Urban Heat Flux and Saving Energy in an Apartment House

THE POLICY FRAMEWORK TO REDUCE URBAN HEAT ISLAND EFFECTS. By Inter-Ministry Coordination Committee to Mitigate Urban Heat Island

DEVELOPMENT OF TRIPLE-EFFECT ABSORPTION CHILLER-HEATER

RETRO-COMMISSIONING OF A HEAT SOURCE SYSTEM IN A DISTRICT HEATING AND COOLING SYSTEM Eikichi Ono 1*, Harunori Yoshida 2, Fulin Wang 3 KEYWORDS

Immediate Supply-Demand Stabilization Measures Accelerate the implementation of structural reforms related to energy. Contents

Climate Change is the biggest challenge of today Mankind. Until now, there is not an easy solution

The Operation Result of the Demonstration of Energy Networks of Electricity, Heat, and Hydrogen at an Apartment Building in 2007

DEVELOPMENT OF A HIGH EFFICIENCY ABSORPTION CHILLER-HEATER AND A COMPACT ABSORPTION CHILLER-HEATER

A CHCP System Constituted by Microturbine and Exhaust Absorption Chiller

Evaluation of the Greenhouse Gas Reduction Effect in the Japanese Residential Sector Considering the Characteristics of Regions and Households

Cogeneration. Thermal Chillers. and. .. ASHRAE National Capital Chapter. Arlington, VA 10/10/2012

Natural Gas and Japanese Energy Market. Hiroshi Ozaki

Development of Residential PEFC Cogeneration. Systems at Osaka Gas

DATABASE AND SIMULATION MODEL DEVELOPMENT FOR MODELLING THE ENERGY USE OF NON-RESIDENTIAL BUILDINGS. Yohei Yamaguchi and Yoshiyuki Shimoda

Current Status of Gas Industry in Japan

BY AQUIFER THERMAL ENERGY STORAGE (ATES)

Project Proposal Proposal for Investigation of Alternative Systems

2015 EDMC Handbook of Japan s & World Energy & Economic Statistics CONTENTS

Heat Pump Hot Water Supply Systems

Special edition paper Research on Utilizing Air Thermal Energy for Railway Facilities

Current New and Renewable Energy Utilization in Japan

Australian Solar Cooling 2013 Conference April 12th, 2013 North Ryde, Australia. All-in-oneSolar Thermal CoolingandHeatingSystem

Study on Performance Verification and Evaluation of District Heating and Cooling System Using Thermal Energy of River Water

BUILDING FOR THE FUTURE

Energy Efficient Heat Pump System Applied Short Term and Seasonal Thermal Energy Storage Part 1 Design concept of the system

Current Status of Gas Industry in Japan

THERMAL CHARACTERISTICS AND ENERGY CONSERVATION MEASURES IN AN INDOOR SPEED-SKATING ARENA

Efficient and Flexible AHAT Gas Turbine System

Chapter 8. Vapor Power Systems

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

STUDY ON OPTIMAL ENERGY SYSTEM DESIGN FOR APARTMENT HOUSE USING GENETIC ALGORITHMS. 375 Seosuk-dong, Dong-gu, Gwangju Korea METHODS

Chapter Six. Load Forecast and Need for Power

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

Innovative Systems for Solar Air Conditioning of Buildings

3 Mechanical System Redesign

DISTRICT HEAT DRIVEN ABSORPTION COOLING OF DISTRICT COOLING PLANTS IN TRONDHEIM, NORWAY

ST-4 Polygeneration plant. Parc de l Alba Cerdanyola del Vallès

performance. In order to make clear the effects of thermal performance and lifestyle on thermal environment and energy consumption for well-insulated

Technical Assignment 2 Building and Plant Energy Analysis

TransPacific Energy Advantage: Case Studies

LOW CARBON HEATING FOR COMMERCIAL BUILDINGS USING GRID SUPPLIED ELECTRCITY DURING-OFF PEAK PERIODS

Parametric study, Space cooling with outdoor air, Simulation, Centralized HVAC system, Weather conditions

Assessing the impacts of shutdown of TEPCO s nuclear reactors on CO 2 emission in the Japan s electricity sector

INITIATIVES OF THE CITY GAS INDUSTRY TO COMBAT GLOBAL WARMING IN JAPAN. Yasutoshi Hattori Manager of Environment Department The Japan Gas Association

Fuel Switch & Energy Efficiency CDM Project Case Study

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

EVALUATION OF DISTRIBUTION SYSTEM PERFORMANCE IN DISTRICT HEATING AND COOLING SYSTEM

Heat Pump Technology Applies on Air-conditioners Impact on Electric Power

Energetic and Economic Analysis of a Micro Gas Turbine Cogeneration System in Residential Buildings in a Tropical Region

AIRAH - BUILDING ENERGY PRECINCTS

Present status of promotion of underground thermal utilization in Japan

Facilities Management System That Reduces Environmental Burden of Buildings

Countermeasure Area Promotion Plan

VERIFICATION OF OPTIMUM OPERATION METHOD BY SIMULATION FOR THE HVAC SYSTEM WITH A THERMAL STORAGE TANK IN AN ACTUAL BUILDING

RISE OF GCC ALTERNATIVE ENERGIES TABLE OF CONTENTS GCC RESPONSE TO LOWER OIL PRICES CONCLUSIONS

A Study on Urban Energy System Planning Based on Long-term Dynamic Model

REPORT ON THE BENEFITS OF ICE- BASED THERMAL STORAGE FOR DISTRICT COOLING IN THE UAE MARKETS

Fiscal year ending March 2007 Third Quarter Financial Results (cumulative)

Prediction of Energy Efficiency and Thermal Environment of Residential Buildings Utilizing PEFC-CGS Combined Floor Heating System

Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine Inlet Cooling

Identified technologies for the InfraSUN pilot plant

Technology and Prospect of Process Heat Application of HTR(High temperature gas cooled reactor) Applications in Oil Refining Industry

Comfortable Energy-Saving & Environment-Friendly

Japan s Energy White Paper 2017

Economic Estimation of Heat Storage Type Geothermal Source Heat Pump System Applied in K-Ward Office Building

Risto Lahdelma Professor, Energy technology for communities Tel:

ADVANCED ABSORPTION CHILLER CONVERTS TURBINE EXHAUST TO AIR CONDITIONING

Thermal Energy Storage

TOP-DOWN VS. BOTTOM-UP MODELS: HOW TO COMBINE THEM TO EVALUATE THE COST OF MID-TERM CO 2 EMISSION REDUCTION?

Eligibility of a Heat Pump Based on the Primary Energy Factor

Eco ice systems mean you use innovative technology for cost-effective and environmentally friendly production of heat and cold.

enables to easily calculate the energy consumption of air conditioning in various conditions (MLIT). In this study, the university building is the obj

Transcription:

Analysis of Distributed Energy Supplying Technologies From the Viewpoint of Waste Heat Yutaka Nagata, Central Research Institute of Electric Power Industry ABSTRACT In Japan and other countries cogeneration systems have attracted attention because of their dramatically increased efficiency. However, these systems consume fossil fuels and there is the fear of worsening the heat island phenomenon, if they are installed in city areas. On the other hand, heat pump technology has been applied to various energy services. Because heat pump technology is quite efficient and if its energy is delivered from the outside of city area, the waste heat in city area is expected to be much less than cogeneration systems even though the loss of generation and transmission is taken into account. This study examined the characteristics of waste heat from various urban energy supplying systems by the reference survey; also, energy consumption and the amount of waste heat from a model house in summer season were estimated. The result shows: 1. The forms of waste heat differ greatly according to the cooling methods of energy supplying systems in commercial use, 2. There are various theories about the influence of latent heat on the heat island phenomenon, 3. Energy consumption is the lowest with the fuel cell cogeneration system (high waste heat recovery), but, the smallest amount of waste heat is exhausted in the city area with a combination of grid electricity and a heat pump water heater. The amount of waste heat from a gas engine cogeneration system and a fuel cell cogeneration system are even larger than that from the combination of grid electricity and an efficient gas water heater. Introduction The penetration of small-sized cogeneration systems (CGSs) has increased in Japan in recent years. According to the statistics of the Japan Cogeneration Center, the number of cogeneration sites in Japan has grown steadily (Figure 1). This is particularly true, in the commercial sector where average size of CGSs is relatively small (less than 500 kw/site, except for district heating and cooling). The prime mover of CGSs for the commercial sector is a gas engine. In addition, sales of a gas engine CGS for the residential sector began in 2003. It is the smallest gas engine CGS, called ECOWILL, with only 1 kw of electrical output (Osaka Gas 2003a). It is expected the penetration of these small-sized CGSs will continue in the residential and commercial sectors in future and they will become a new source of waste heat in city areas. Concentrated consumption of energy in metropolitan areas is considered to be one of the root causes of the heat island phenomenon. According to the Ministry of Environment, the total number of the hours when the atmospheric temperature exceeded 30 C in Tokyo area doubled from 168 to 357 over the past twenty years (Ministry of Environment 2001). At present the increase in artificial sensible heat from the natural condition in central 3 wards of Tokyo is 61.9W/m 2, which is considerably larger than other areas in Japan (Center for Environmental Information Science 2002).

Figure 1. The Cumulative Number and Capacity of Cogeneration Sites Each Year Capacity (MW) 7,000 6,000 5,000 Accumulated Capacity (Industrial) Accumulated Capacity (Commercial) Accumulated Number Number 5,000 4,500 4,000 3,500 4,000 3,000 2,000 1,000 0 ~'80'81'82'83'84'85'86'87'88'89'90'91'92'93'94'95'96'97 '98'99'00'01'02 Fiscal Year Source: Japan Cogeneration Center. 2004 3,000 2,500 2,000 1,500 1,000 500 0 CGSs are energy-efficient if their waste heat is utilized effectively, but the rate of waste heat recovery declines in summer months because of limited demand for hot water and heat. On the other hand, generating efficiency of large-scale LNG combined cycle power plants exceeds 50% 1 at full-load operation and some percentage of capacity located outside of the city area. Moreover, a hot water heater called Eco Cute, which uses heat pump technology, was developed in 2001 and its annual average COP is 3.0 or more (Tokyo Electric Power Company 2003) 2. This combination of grid electricity from the outside of the city area and an efficient water heater offers the possibility of reducing waste heat discharge in the city area much more than CGSs, even though the loss of generation and transmission of electricity is taken into account. Through literature review of waste heat discharge from distributed energy supplying systems and its relationship to the heat island phenomenon, we ve estimated the amount of waste heat from various energy supplying systems. The targeted technologies were cogeneration systems (both gas engine and fuel cell), heat pump water heaters, and efficient gas water heaters. Relationship between Energy Utilization and Heat Island Phenomenon: A Survey As shown in Figure 2, several stages exist between energy utilization and the heat island phenomenon. In the first stage, the demands for energy services are determined by climatic conditions, load pattern of users, and percentage by user type (residential, commercial, industrial). In the second stage, the demands for commercialized energy are determined mainly by type of device, device efficiency, and operating mode. In the next stage, the amount of waste heat can be estimated. The forms of waste heat (sensible or latent) have a different impact on the heat island phenomenon as described later. The cooling methods of the various devices (cooling tower, outside unit, or heat recovery as hot water) determine the form of this waste heat. The resulting changes to local climate will, in turn, impact demand for energy services. Many uncertainties exist in each stage and they are investigated in this section by the reference survey. 1 Thermal efficiency is expressed by the high heat value (HHV) base in this paper. 2 The unit for household use was commercialized first. Then the sales of commercial unit started in 2002.

Figure 2. Relationship between Energy Utilization and Heat Island Phenomenon: Many Stages of Uncertainties Climatic Condition Load Pattern of User Percentage by User Type of Device Device Efficiency Operating Mode Cooling Method of Device (Cooling Tower, etc.) Effect of Waste Heat on Atmospheric Environment Air Conditioning / Ventilation Demand Demand Socket / Motive Power Demand Grid Demand Town Gas Demand Petroleum Products Demand Amount of Sensible Heat Amount of Latent Heat Heat Island Phenomenon The first uncertainty is the consumption of commercialized energy in the city area. Fortunately, energy consumption statistics by prefecture for grid electricity and city gas exist in Japan. However, for petroleum products, only sales statistics are available and, because large portions of them are consumed in the transportation sector, it is difficult to precisely estimate the consumption of petroleum products by prefecture. The situation gets worse to estimate the energy consumption by the type of device. For example, the statistics of consumed energy by CGS are not available separately; they are included in total consumption along with other devices. A typical manner to estimate it is bottom-up calculation. Ashie et al. estimated waste heat of air conditioning systems from five kinds of buildings in August in Tokyo area (Ashie et al. 2002). The floor space is 10,000 m 2 for each building type. The declines in efficiency by partial-load are taken into account for the calculation of energy consumption. The standard values of demands for energy services estimated by the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan (excepting schools) and by Waseda University s Ojima laboratory (for schools) are used in this estimation. This means variation in demand for energy services is neglected, thus there is no guarantee the result of the estimation expresses the actual conditions. The estimated results show that the forms of waste heat are closely correlated to the cooling method (Table 1), in that the form of waste heat from air-cooled systems will be mostly sensible heat while that from water-cooled systems will be mostly latent heat. Shimoda et al. estimated waste heat from other air conditioning systems of office buildings in Osaka area (Shimoda et al. 2003) with a floor space of 30,000 m 2. The result is almost the same as the Ashie s study: the waste heat from the electric systems is mostly sensible heat and that from gas systems is mostly latent heat (Table 2). However, the form of waste heat from a gas engine CGS changes according to its actual operating mode. Kikegawa et al. estimated the changes in average atmospheric temperature in summer that would be derived by replacing air conditioning systems in the central area of Osaka City using their original MM-CM-BEM model (Kikegawa et al. 2003). They assumed the waste heat from a gas engine CGS is discharged as both 100% sensible heat and 100% latent heat respectively, considering the variations in the control method of heat radiation (Figure 3). That assumption means the waste heat of CGSs is not always recovered and CGSs are sometimes operated in the mono-generation (no heat recovery) mode. Their findings are very interesting: if all of the waste heat from gas engine CGSs is discharged as sensible heat, atmospheric temperature will rise by 0.3 C; conversely, atmospheric temperature will fall by 0.1 C if the waste heat is discharged as latent heat.

Table 1. Amount of Waste Heat from Air Conditioning Systems and Related Devices (August, Tokyo Area) Building Type Type of Air Conditioning System Sensible Heat Latent Heat Office Air-Cooled Electric Chiller 1,100.5-60.5 Air-Cooled Electric Heat Pump 833.3-60.5 Direct-Fired Absorption Chiller/Heater (Water-Cooled) 426.7 979.4 Wholesale / Retail Air Cooled Electric Heat Pump 1,383.1-120.1 Direct-Fired Absorption Chiller/Heater (Water-Cooled) 607.4 1,473.1 Steam-Fired Absorption Chiller (Water-Cooled) 625.1 1,542.8 Hotel Air-Cooled Electric Heat Pump 1,402.7-52.1 Direct-Fired Absorption Chiller/Heater (Water-Cooled) 884.1 1,802.7 Steam-Fired Absorption Chiller (Water-Cooled) 825.3 1,941.8 House Room Air Conditioner (Air-Cooled) 188.6-28.4 School No Systems 78.3 0.0 Unit: (W h) / (m 2 day) Source: Ashie et al. 2002 (translated). Table 2. Amount of Waste Heat from Air Conditioning Systems (Office Building, August, Osaka Area) Type of Air Conditioning System Daytime (7am - 6pm) Nighttime (7pm - 6am) Sensible Heat Latent Heat Sensible Heat Latent Heat Gas Engine CGS - 48.2 161.7 0.0 1.1 Gas Absorption Chiller/Heater - 53.9 163.5-0.3 1.2 Air-Cooled Electric Heat Pump 69.2-32.7 0.6-0.3 Air-Cooled Electric Heat Pump + Ice Thermal Storage 20.2-32.7 61.0-0.3 Unit: GJ / day Source: Shimoda et al. 2003 (translated). Figure 3. Standard Composition of a Gas Engine Cogeneration System Exhausted Gas Cooling Water Waste Heat (Mostly Sensible Heat) By-pass Pipe (Waste Gas) Heat Exchanger for Hear Recovery Gas Engine Jacket Cooling Water Heat Exchanger By-pass Pipe () Heat Demand (Air Conditioning, ) Waste Heat (Mostly Latent Heat) Cooling Tower Heat Exchanger Source: Kikegawa et al. 2003 (translated).

It s clear that sensible heat raises the ambient atmospheric temperature and is directly related to the heat island phenomenon. On the other hand, there are different opinions about the impact of latent heat on the heat island trend; making this another point of uncertainty. If the impact of latent heat is much smaller than that of sensible heat, a water-cooled absorption chiller/heater and a gas engine CGS are very effective means of mitigating heat accumulation. But various secondary effects of latent heat s relationship to the heat island phenomenon can be imagined. One is condensation of vapor that is discharged from a water-cooling tower. During this process, the latent heat of the vapor is transformed to sensible heat. Another effect is the increase in humidity and a resulting increase in energy demand for dehumidification. Shimoda et al. assessed the effects of artificial waste heat on the atmospheric environment by the Effective Temperature (ET). ET is a function of temperature, airflow, clothing, and/or metabolism. They calculated the relative magnitude of latent heat to be 0.8 times the daytime sensible heat of Osaka area in August. That means latent heat has an impact comparable to sensible heat. Another possibility exists in sensible heat of waste hot water. If it is drained to the sea, whose heat capacity is enormous, its impact on atmospheric temperature can be negligible. The Japan District Heating & Cooling Association studied the effects of collecting and disposing of the waste heat from air conditioners in about 2 km 2 area around Tokyo Station by building a duct to Tokyo Bay. This study indicated the maximum temperature would be lowered by 0.4 C on average (Japan District Heating & Cooling Association 2003). They also examined the impact of waste hot water to the sea on atmospheric temperature and concluded it is negligible compared with the cooling effect. However, it is expected some portion of sensible heat of waste hot water is lost as sensible heat before reaching sewage plants and/or during the processing of the sewage. Looking within the context of these possibilities, only sensible heat discharged from aircooled air conditioning systems shows a clear relationship to the heat island phenomenon. The impact of other forms of heat on the heat island phenomenon varies according to the method of assessment. Estimating the Amounts of Waste Heat Discharge from a Model House in Summer As described earlier, the relationship between energy utilization and the heat island phenomenon is very complicated. In particular, in the commercial sector the ratio of sensible and latent heat changes greatly according to the cooling method employed by heat source devices. In this section, the amount of waste heat discharge from a model house in August is estimated because all of the residential devices are air-cooled and waste heat is discharged as sensible heat. Like in other study, the standard values of demands for energy services as estimated by the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan are used. Unit demand per floor space is shown in Figure 4. Floor space is assumed to be 120 m 2 based on recent averages. Figure 5 shows the selected energy supplying systems. All of these devices are expected to penetrate in the near future 3. The efficiencies of the gas water heater, the gas engine CGS, and the heat pump water heater are catalogue values at full-load operation (heat loss from water tank is included in the efficiency of heat pump water heater). The efficiency of the Proton Exchange Membrane (PEM) fuel cell CGS is the target value of technical development by manufacturers and city gas suppliers. Both of the CGSs have 1 kw electric output. Because demand for hot water is smaller in the summer, it is assumed a back-up boiler for hot water supply is not needed. 3 Gas water heater supposed in this study is an efficient, latent heat recovery-type for a house developed in 2002 Osaka Gas 2003a). COP of a peat pump water heater is annual average and it is more efficient in summer.

Figure 4. Demand for Energy Services of a Model House (in August, Tokyo Area) (W/m 2 ) 20 18 16 14 12 10 8 6 4 2 0 Air Conditioning 0 1 2 3 4 5 6 7 8 9 1011 12 131415 16171819 2021 2223 Hour Figure 5. Selected Energy Supplying Systems System Energy Flow and Efficiency of Devices Hour Hot Air Con- Water ditioning 0 0.84 0.63 0.43 1 0.84 0.72 0.43 2 0.84 0.47 0.43 3 0.84 0.00 0.43 4 0.51 0.00 0.43 5 0.51 0.08 0.43 6 1.67 0.55 0.43 7 2.31 0.97 2.01 8 2.57 1.06 2.72 9 2.25 0.85 3.30 10 2.25 0.72 3.44 11 2.31 0.89 4.44 12 2.44 0.76 5.88 13 2.64 0.76 8.74 14 2.64 0.76 9.60 15 2.51 0.76 7.45 16 2.38 1.69 6.31 17 2.44 2.96 6.74 18 3.60 4.02 6.74 19 6.36 5.29 17.91 20 6.30 5.20 19.78 21 5.98 5.16 17.20 22 5.08 5.12 9.60 23 4.18 2.88 8.46 Total 64.29 42.31 143.32 Unit: W/m 2 System 1 (Grid + Efficient Gas Water Heater) Grid City Gas η=36.8% (total average), 42.75% (bay area LNG) HP Heater COP=4 η=95% Air Conditioning System 2 (Grid + Heat Pump Water Heater) Grid HP HP COP=4 COP=3 Air Conditioning System 3 (Grid + Gas Engine CGS + Heat Recovery Device) Grid City Gas η=18.1% Gas Engine HP η=58.7% HRD COP=4 Air Conditioning System 4 (Grid + Fuel Cell CGS + Heat Recovery Device) Grid City Gas η=31% Fuel Cell HP η=40% HRD COP=4 Air Conditioning Two ways of considering the efficiency of grid electricity are used: one is the average of all power plants and the other is the efficiency of LNG power plants located in Tokyo bay area (Figure 6) 4. This difference is important in that it allows us to account for the location of waste heat discharge from power plants and the loss of transmission. Overall efficiency of grid electricity is assumed to be 36.8% (=40% for generating and 8% loss for transmitting) for the former case and 42.75% (=45% for generating and 5% loss for transmitting) for the latter case. 4 This consideration relates to the discussion of marginal power plants. It means the type of power plants whose new construction is postponed will change if CGSs will be installed and demand for grid electricity will decrease.

Figure 6. Locations and Capacities of Large-Scale Power Plants Surrounding Tokyo Metropolitan Area kwh Share (2000) Coal Others Hydro Oil 42% 35% Nuclear LNG, LPG Tokyo Metropolitan Area > 5,000MW 3,000~5,000 1,000~3,000 < 1,000MW Nuclear LNG, LPG Coal Oil Hydro Operating patterns of CGSs are assumed as follows: for a gas engine CGS, the operating hours are determined so as to minimize total running cost of grid electricity and city gas based on the current rates of Kansai Electric Power Company and Osaka Gas. Total running cost is minimized just before the ratio of waste heat recovery begins to fall (Figure 7). According to the trial calculations by Osaka Gas, the annual average of operating hours is 4.34 hours/day (Osaka Gas 2003b). These estimated operating hours seem appropriate because the demand for hot water in summer is less than the half of annual average and there also is no heating demand. Figure 7. Total Running Cost and Ratio of Heat Recovery as a Function of Operating Hours of a Gas Engine CGS (August) (Yen/month) 11,600 Ratio of heat recovery (right axis) 70% 60% 11,400 50% 11,200 40% 30% 11,000 Monthly running cost (left axis) 20% 10% 10,800 0% 0.0 0.5 1.0 1.5 2.0 2.5 (Hours/day)

Two types of operating patterns are assumed for fuel cell CGS. Because a fuel cell CGS is much more efficient at power generation than a gas engine CGS, the mono-generation operation is still economic if the discounted rate of city gas for a gas engine CGS is applied 5. Therefore, electricity demand following and high heat recovery operating patterns are assumed. A fuel cell CGS is operated during the hours when the demand for electricity exceeds the technically minimum load (25% of full-load electric output) in the former pattern. In the latter pattern, the operation of a fuel cell CGS is limited from 6 p.m. to 11 p.m. in order to achieve the high rate of waste heat recovery. Table 3 shows the estimated energy consumption and efficiency of the energy supplying systems. As for energy consumption, a fuel cell CGS in the high heat recovery operating pattern (System 4-2) is the smallest on the primary base. This is because both high generating efficiency and waste heat recovery are achieved at the same time. A gas engine CGS (System 3) has comparable CGS efficiency to that of System 4-2; however, it consumes primary energy the most because of low generating efficiency. Overall efficiency has the same tendency: System 2 and System 4-2 have very high efficiency and System 1 follows. This result shows that generating efficiency for a gas engine CGS and the ratio of heat recovery for a fuel cell CGS need to be improved to achieve overall efficiency comparable to those of other energy supplying systems. Table 4 shows the waste heat discharge from these systems. To calculate the waste heat in the city area, half of all large-scale power plants and total from bay area LNG power plants are counted respectively, considering the kwh share by power plants (see pie graph in Figure 6) and seasonal differences 6. Table 3. Energy Consumption and Efficiency of a Model House (August) System 1 System 2 System 3 System 4-1 System 4-2 (Elec. Follow) (Heat Recovery) Secondary Base Total 17.36 13.71 21.09 34.97 22.10 Grid 12.01 13.71 10.01 1.70 7.48 City Gas 5.34-11.08 33.27 14.62 Primary Base Total *1 37.99 37.25 38.29 37.89 34.95 Grid 32.65 37.25 27.21 4.62 20.33 City Gas 5.34-11.08 33.27 14.62 Efficiency of CGS - - 63.9% 46.3% 65.7% Generation - - 18.1% 31.0% 31.0% Heat Recovery - - 45.8% 15.3% 34.7% Overall Efficiency All power plant *1 78.9% 80.5% 67.1% 79.1% 85.8% Bay area LNG *2 89.7% 93.5% 74.5% 80.5% 93.4% Unit: kwh / day *1 Based on the average of all power plants (generating efficiency: 40%, loss for transmitting: 8%). *2 Based on the LNG power plants located on Tokyo bay area (generating efficiency: 45%, loss for transmitting: 5%). 5 Marginal gas price in summer is 63.46 yen/m 3 for a gas engine-cgs at present, and so the mono-generation production cost of electricity is calculated to be 16 yen/kwh. It is cheaper than the normal rates of grid electricity. 6 The ratio of thermal power plants becomes large in summer and winter when the demand for electricity is large in Japan because nuclear and hydro power plants supply base-load electricity and thermal power plants supply middle and peak-load electricity.

Table 4. Waste Heat Discharge from a Model House (August) System 1 System 2 System 3 System 4-1 System 4-2 (Elec. Follow) (Heat Recovery) Total (all power plant) *1 37.99 37.25 38.29 37.89 34.95 In city area 21.67 18.62 24.69 35.58 24.78 Outside of city 16.32 18.62 13.61 2.31 10.17 Total (bay area LNG) *2 33.45 32.06 34.50 37.25 32.12 In city area 33.45 32.06 34.50 37.25 32.12 Total (without waste water) *3 14.82 11.17 17.84 28.32 19.18 Unit: kwh / day *1, *2 Same as *1 and *2 notes of Table 3. *3 Without total waste heat from large-scale power plants and a half of on-site waste hot water. The result shows the system using a heat pump water heater (System 2) discharges the least waste heat in the city area, even if bay area LNG power plants are chosen and all of the waste heat from power plants is assumed to be discharged into the city area. If it is supposed that the effect of waste hot water on the heat island phenomenon is extremely small, the superiority of System 2 to other systems increases. On the other hand, the amount of waste heat from a gas engine cogeneration system and a fuel cell cogeneration system are larger than that from the combination of grid electricity and an efficient gas water heater. It seems CGS systems have high potential for increasing waste heat in city areas as compared with other systems. If a subsidy is applied to fuel cell CGSs and gas companies set discounted gas rates for them, then System 4-1 could exist in the near future; however, from the viewpoint of waste heat discharge this outcome is not desirable. Conclusions This study examined the characteristics of waste heat from various urban energy supplying systems by the reference survey and energy consumption, also the amount of waste heat from a model house in the summer season was estimated. The results are summarized as follows: 1. The forms of waste heat differ greatly according to the cooling methods of the energy supplying systems in commercial use. 2. There are various theories about the influence of latent heat on the heat island phenomenon. 3. Among the various energy supplying systems for a model house, energy consumption by the fuel cell cogeneration system (high waste heat recovery) is the lowest. On the other hand, the amount of waste heat in discharged into the urban environment by a combination of grid electricity and a heat pump water heater is the lowest. The results show that heat pump technology can reduce the waste heat considerably and that CGSs can increase the waste heat in the city area in the summer. The main reason is that heat pump water heaters collect atmospheric heat effectively to produces hot water. Therefore, it is desirable to promote the introduction of heat pump water heaters in the buildings sector. Another important point addressed in this paper was the assessment of the distributed energy supplying systems from the viewpoint not only of energy consumption and CO 2 emissions, but

also by the form of waste heat and the location where that heat is discharged. I believe the content of this paper will provide valuable information for both policy makers who must tackle the heat island problem, and for city planners who are seeking energy-efficient and environmental-friendly energy supplying systems for their urban areas. References Ashie, Y., Tanaka, M., Yamamoto, T., and Taguchi, A. 2002. A Study of the Regional Heat Discharge from Air Conditioning Systems and Related Devices Based on the Composition Ratio of Cooling Heat Source Devices. Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, (86): 77-86. Tokyo.: The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan (in Japanese). Center for Environmental Information Science 2002. Report of the Investigation about the Measures for Heat Island. Available online: www.env.go.jp/air/report/h14-02/ (in Japanese). Japan Cogeneration Center, Situation of Cogeneration. Available online: www.cgc-japan.com/ english/eng04.html. Japan District Heating & Cooling Association. 2003. Report of the Study of Introducing the Disposal System of Urban Waste Heat (Fiscal Year 2002). Tokyo (in Japanese). Kikegawa, Y., Genchi, Y., Ohashi, Y., and Kondo, H. 2003. Impacts of Composition of the Power Generation and Cooling System upon Urban Thermal Environment in Summer. Proceedings of the 19th Energy System / Economics / Environment Conference, 69-74. Tokyo.: The Society of Energy and Resources (in Japanese). Ministry of Environment. 2001. Analysis of the Actual Situation and Measures for Heat Island. Available online: http://www.env.go.jp/air/report/h13-01.pdf (in Japanese). Osaka Gas. 2003a. Environmental and Social Action Reports 2003. Available online: www.osakagas.co.jp/kankyo_e/environmental/report_2003.htm. Osaka Gas. 2003b. The Economics of ECOWILL. Available online: www.g-life.jp/html/scene/ cogeneration/ecowill/point/point03.html (in Japanese). Shimoda, Y., Nakatsu, K., Mizuno, M., and Tanaka, T. 2003. Life-Cycle Impact Assessment of Heat Source Equipment in Building. Transactions of the Society of Energy and Resources, 24 (6): 55-61. Osaka.: The Society of Energy and Resources (in Japanese). Tokyo Electric Power Company. 2003. TEPCO Sustainability Report 2003. Available online: www.tepco.co.jp/plant-sit-env/environment/report/pages/tog_7071-e.html.