TRANSOM AND SIDELIGHT FRAMES:

Similar documents
INDEX General Information Flush Frames Drywall Frames Technical Data Sheets Anchors

Revision Details TECH MANUAL

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

Table of contents (click below or use bookmarks)

INDEX. General Information Overview Full Flush Doors Stile and Rail Doors. Full Flush Door Constructions L Series

HOTEL SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

SECTION METAL DOORS & FRAMES

Installation Instructions

SECTION STEEL DOORS AND FRAMES

TECHNICAL RESOURCE GUIDE CODE COMPLIANCE + TESTING

Built to Order. Stile. Frames. Section Contents. Profiles. Elevations. Double Egress Frames Pocket Frames

Stiles doors save lives. Stiles is a national leader in fire ratings and maintains a vast portfolio of options to the architect and builder.

ADVANCE METAL INDUSTRIES L.L.C.

SECTION METAL DOORS & FRAMES

HMMA 850 GUIDE SPECIFICATIONS FIRE - RATED HOLLOW METAL DOORS AND FRAMES DOORS AND FRAMES THIRD EDITION HOLLOW METAL MANUAL -00 NAAMM STANDARD

MegaSonic 2A - Series Flush Doors

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

DETAILED METAL DOOR SPECIFICATION. UNIVERSITY CONTACT: Mark Golden, Supervisor of Structural Services (302)

Hollow Metal Doors and Frames

1-3/4 Whisper Core Door Systems

1701 Hollow Metal Door with Polystyrene Core Bullet Resistant UL 752 Level 1

Division 08 Openings Section Ohio Utilities Protection Service New Office Building Bid Package B METAL DOORS AND FRAMES

SUBMITTAL PACKAGE CUSTOM HOLLOW METAL DOORS, FRAMES AND WINDOWS

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

fireglass.com. Technical Glass Products Architectural Specification Manual

Table of contents (click below or use bookmarks)

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

fireglass.com. Technical Glass Products Architectural Specification Manual

HOLLOW METAL DOORS AND FRAMES

AMBICO Limited Section and ACOUSTIC STEEL DOOR AND FRAME ASSEMBLIES Page 1

A. Minimum Thickness: Minimum thickness of base metal without coatings according to NAAMM-HMMA 803 or SDI A250.8.

.1 [Non-rated] [fire rated] pressed steel, lead-lined steel frames. .2 [Non-rated] [fire rated] hollow metal, lead-lined doors [and panels].

Product Description. Standard Sizes and Hardware Locations

FLEETWOOD Windows & Doors

SECTION HOLLOW METAL DOORS AND FRAMES. A. Section includes steel doors and frames (hollow metal) indicated and as specified.

St. Monica Food Pantry Hollow Metal Doors and Frames SBA-13105

HMMA hmm08b Installation and Storage of Hollow Metal Doors and Frames. An American Institute of Architects (AIA) Continuing Education Program

Woolf Distributing. Commercial Door Division. Commercial Steel Doors & Frames. Commercial Wood Doors

Comparison letter for MegaMet s MegaStorm Door against door construction details in FEMA 361 section 7.4.1

FIRE-PROTECTION AND SMOKE CONTROL RATED HOLLOW METAL DOOR AND FRAME PRODUCTS

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

B. Related Sections: The following Sections contain requirements that relate to this Section:

INDEX General Information Physical Endurance Insulation Factors

ELEVATION TYPES ELEVATION TYPES (SLIDING ENTRANCE) ELEVATION TYPES (BI-FOLDING ENTRANCE) SECTION DETAILS STAINLESS STEEL BRONZE ENTRANCES

AMBICO Limited Section WOOD SOUND CONTROL DOOR AND STEEL FRAME ASSEMBLIES Page 1

PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

TABLE OF CONTENTS: HURRICANE RESISTANCE STOREFRONT SERIES IT600 REVISION D E S C R I P T I O N HURRICANE RESISTANT STOREFRONTS CRL / US ALUMINUM

Standard hollow metal doors frames. Minimum Thickness: Minimum thickness of base metal without coatings.

JOB NAME SIMULATED STILE AND RAIL MDF DOORS of 8 REVISED 03/01/11 SECTION STILE AND RAIL MDF DOORS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Hurricane System

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

C S I S E C T I O N STAINLESS STEEL DOORS AND FRAMES SPECIFICATIONS

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

[PROJECT NAME] [PROJECT NUMBER] [CITY AND STATE]

CERTIFICATE OF APPROVAL No CF 5158 WHITE ALUMINIUM ENTERPRISES L.L.C.

CURRIES Tech Manual Windstorm Section. Revised April, 2018

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

ADDENDUM # 1 To: RFP for: Blanco Store Fronts, Lighting & Mechanical Improvements

Structural Performance Ratings of Side-Hinged Exterior Door Systems and Procedures for Component Substitution

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Architectural Series Framing

C. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) B221: Aluminum-Alloy Extruded Bars, Rods, Shapes and Tubes.

RATING: Consult factory for availability Consult factory for availability

SECTION HOLLOW METAL DOORS AND FRAMES

FLEETWOOD Windows & Doors

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

TECHNICAL INFORMATION

Lykes Steamship Building 1770 Tchoupitoulas St. New Orleans, LA

ARCHITECTURAL MANUAL. S01 1 May 00 COMMERCIAL STEEL DOOR AND FRAME SPECIFICATIONS CSI BROADSCOPE SECTION INTRODUCTION

/ TECHNICAL DATA DOORS

Marshfield DoorSystems

CERTIFICATE OF APPROVAL No CF 185 LORIENT POLYPRODUCTS LIMITED

DIVISION 8 OPENINGS SECTION HOLLOW METAL DOORS AND FRAMES

National Custom Hollow Metal Doors & Frames

A NEW SCHOOL ATHENS BIBLE SCHOOL FOR THE PRESIDENT AND BOARD OF DIRECTORS ATHENS, ALABAMA

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass

Architectural Specification Manual

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

C A R T E R W A T K I N S A S S O C I A T E S A R C H I T E C T S, I N C.

Bringing Success To Your Door

Sliding Patio Doors Brickmould Vinyl

SECTION SECURITY DOORS AND FRAMES

Product Specification Guide

B. Hollow Metal work for Interior frames, including Glazing Stops.

A. Access doors and frames are part of an access door and frame allowance.

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

PART 1 GENERAL HOLLOW METAL DOORS AND FRAMES

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

AMBICO Limited Section and STAINLESS STEEL DOORS AND FRAMES Page 1

Intertek NAFS-11 Testing

.1 Blast-resistant non-fire rated pressed steel frames. .4 Factory supplied [and installed] glass and glazing.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

Stiles. Stainless Steel. Stiles Stainless Steel... The Fusion of Art & Technology. Section Contents. Doors. Elevations + Construction Data

Republic Doors and Frames has a long history as one of the nation's leading manufacturers of commercial steel doors and frames.

SECTION BLAST-RESISTANT DOORS AND FRAMES

COMPLETE REVISION November Process Industry Practices Architectural. PIP ARS08111 Standard Steel Doors and Frames Supplier Specification

Installation, Operation and Maintenance Manual

COMPLETE REVISION June Process Industry Practices Architectural. PIP ARS08390 Blast Resistant Doors, Frames, and Related Hardware Specification

Transcription:

TRANSOM & SIDELIGHTS FIRERATEDPRODUCTS TRANSOM AND SIDELIGHT FRAMES: s Sidelight Frame Sidelight Frame Transom/Sidelight Frame Transom Frames with Bar FIRE RATED TRANSOM AND SIDELIGHTS: The transom and sidelight frames covered in this section, have been tested in accdance with UL 10C, NFPA 252-1999 and listed by either Underwriters Labaties (UL), Warnock Hersey (ITS/WHI) and FM Global (FM). The ratings and sizes available are shown on the following pages. Labeled transom and sidelight frames are welded pri to arriving at the jobsite and are available in the following configurations: Transom Light frame A frame assembly which includes a fixed hizontal transom bar, and a light (window) directly above the do. The transom bar separates the do opening from the transom light. The do opening can be f: Single do latching into end jamb window/panel mullion Two single dos with a center mullion Rim FEH latching into hardware manufacturer s mullion Lock/latch sets latching into hollow metal mullion Double (pair) do without a mullion & swinging in same direction Sidelight frame A frame assembly which includes both a fixed vertical mullion bar, and a light (window) adjacent to one both sides of the do. The mullion bar separates the do opening from the side light. The do opening can be f: Single do latching into end jamb window/panel mullion Two single dos with a center mullion Rim FEH latching into hardware manufacturer s mullion Lock/latch sets latching into hollow metal mullion Double (pair) do without a mullion & swinging in same direction Transom and Sidelight frame A frame assembly which includes a fixed hizontal transom bar, and a light directly above the do, and a fixed vertical mullion bar, and a light adjacent to one both sides of the do. The do opening can be f: Single do latching into end jamb window/panel mullion Two single dos with a center mullion Rim FEH latching into hardware manufacturer s mullion Lock/latch sets latching into hollow metal mullion Double (pair) do without a mullion & swinging in same direction APPROVED FRAME SERIES: Frames covered in this section are F and MU. Regardless of the frame series being used, all frames must be installed into a fire rated wall. SIZE LIMITATIONS: Transom and side light frames must be shipped as welded units. Frames may be field spliced. F splicing details, refer to the Elevation Section of this manual. Maximum width, height and ratings shown on the following pages LISTING INFORMATION COVERED: All listings covered in this section are f reference and assistance in developing overall parameters of approvals. Several variables such as hardware, wall construction and application will affect the fire ratings. Individual manufacturer's listings will take precedence. All listings shown on this section confm to UL 10C and NFPA 252. INSTALLATION: Installation of all craft framing systems shall confm to the published craft installation instructions, ANSI/SDI A250.11 Recommended Installation Instructions f Frames and ANSI A250.11 and HMMA 840. All fire rated frames and dos must be installed in accdance with NFPA Pamphlet 80, and/ the local AHJ. Technical Data Manual Rev. 11/08 9.4.1

TRANSOM SIDELIGHT FRAME WITH AND/OR 1/2 STEELCRAFT LAMINATED STEEL PANELS FIRERATEDPRODUCTS TRANSOM & SIDELIGHTS Frame Infmation Listings Maximum Wall Jamb Depth Maximum Overall Frame Width & Height Rating Application Series Min. Max. UL ITS/WHI FM 1-1/2 Hr Masonry F16, F14 3 14 13'6" x 12'2" 13'6" x 12'2" N/A (90 min) Masonry MU16, MU14 3-1/4 14 13'6" x 12'2" 13'6" x 12'2" N/A Max Stud F16, F14 3-3/4 14 13'2" x 12'2" 13'2" x 12'2" N/A Stud MU16, MU14 3-3/4 14 13'2" x 12'2" 13'2" x 12'2" N/A 1. All frames must be shipped as welded units. Frames can be field spliced. 2. Do opening: All frames can be prepared f use with a single double do. Maximum single do size = 4'0" x 10'0". Maximum double do size = Max. 8'0" x 10'0". Double do can be with without vertical mullion. Frame can have up to two single do openings one pair do opening. Pair opening dos must swing in same direction. 3. Glazing requirements: All glass must be listed glazing material. 1/2" thick laminated panels with mineral board ce. sizes are as follows: a. Transom panels = 48 wide X 38 high b. Side panels = 38 wide X 48 high Glazing stop/bead requirements: a. Stop width minimum 7/16" as required by glazing manufacturer. b. Stop height minimum 5/8" as required by glazing manufacturer. c. Glazing bead minimum 18 gage, as required by glazing manufacturer. 4. Special profile may be necessary due to special thickness of glazing. 5. Frame profile variations: Perimeter (Head and Jambs) frame a. Masonry walls = minimum face 1" (FN) b. Stud walls = minimum face 1-1/4" c. Maximum face 4" masonry, steel wood stud walls. Interi dividing members a. Members at do opening minimum face 1". b. Vertical maximum face 4-1/2" c. Hizontal maximum 8". Sill section Minimum Face 2", maximum 16-1/8" 6. The use and installation of frames with 1-1/2 hour (90 minute) ratings are subject to the approval of the local AHJ. These assemblies are tested and listed in accdance with UL10C and NFPA 252. Fire-protection-rated glazing materials must be installed in these assemblies. These assemblies are not tested in accdance with ASTM E119 UL 263 (Fire Tests of Building Construction and Materials) and use of Fire-resistance-rated glazing materials will not make the frame compliant with ASTM E119 UL 263. Transom Frame / Sidelite Frame assemblies are tested and listed f fire protection in accdance with UL10C and NFPA 252. Where fire protection ratings are required, fire protection rated glazing shall be installed. The installation of fire resistance rated glazing does not qualify these assemblies f compliance with ASTM E119 UL 263. The use and installation of transom sidelite frames are subject to approval of the AHJ. 9.4.2 Technical Data Manual Rev. 11/08

TRANSOM & SIDELIGHTS FIRERATEDPRODUCTS TRANSOM SIDELIGHT FRAME WITH AND/OR 1-3/4 RATED WOOD PANELS Frame Infmation Listings Maximum Wall Jamb Depth Maximum Overall Frame Width & Height Rating Application Series Min. Max. UL ITS/WHI FM 1-1/2 Hr Masonry F16, F14 4-3/4" 12-3/4" 13'6" x 12'2" 13'6" x 12'2" N/A (90 min) Masonry MU16, MU14 4-3/4" 12-3/4" 13'6" x 12'2" 13'6" x 12'2" N/A Max Stud F16, F14 4-3/4" 12-3/4" 13'2" x 12'2" 13'2" x 12'2" N/A Stud MU16, MU14 4-3/4" 12-3/4" 13'2" x 12'2" 13'2" x 12'2" N/A 1. All frames must be shipped as welded units. Frames can be field spliced. 2. Do opening: All frames can be prepared f use with a single double do. Maximum single do size = 4'0" x 10'0". Maximum double do size = Max. 8'0" x 10'0". Double do can be with without vertical mullion. Frame can have up to two single do openings one pair do opening. Pair opening dos must swing in same direction. 3. dos and panels: Maximum width, height, and rating based on wood do manufacturer's listing. 4. Glazing requirements: All glass must be listed glazing material. Glazing stop/bead requirements: a. Stop width minimum 7/16" as required by glazing manufacturer. b. Stop height minimum 5/8" as required by glazing manufacturer. c. Glazing bead minimum 18 gage, as required by glazing manufacturer. 5. Special profile may be necessary due to special thickness of glazing. 6. Frame profile variations: Perimeter (Head and Jambs) frame. a. Masonry walls = minimum face 1" (FN). b. Stud walls = minimum face 1-1/4". c. Maximum face 4" masonry, steel wood stud walls. Interi dividing members. a. Members at do opening minimum face 1". b. Vertical maximum face 4-1/2". c. Hizontal maximum 8". Sill section Minimum face 2", maximum 16-1/8". 7. panels can be used in conjunction with metal panels glass. 8. Maximum jamb depth: 14 if any glass is installed. 12-3/4 if all wood panels. 9. The use and installation of frames with 1-1/2 hour (90 minute) ratings are subject to the approval of the local AHJ. These assemblies are tested and listed in accdance with UL10C and NFPA 252. Fire-protection-rated glazing materials must be installed in these assemblies. These assemblies are not tested in accdance with ASTM E119 UL 263 (Fire Tests of Building Construction and Materials) and use of Fire-resistance-rated glazing materials will not make the frame compliant with ASTM E119 UL 263. Transom Frame / Sidelite Frame assemblies are tested and listed f fire protection in accdance with UL10C and NFPA 252. Where fire protection ratings are required, fire protection rated glazing shall be installed. The installation of fire resistance rated glazing does not qualify these assemblies f compliance with ASTM E119 UL 263. The use and installation of transom sidelite frames are subject to approval of the AHJ. Technical Data Manual Rev. 11/08 9.4.3

FIRERATEDPRODUCTS TRANSOM & SIDELIGHTS TRANSOM FRAME WITHOUT TRANSOM BAR (1-3/4 wood panel installations) NOTE - Listed f Neutral Pressure - do manufacturers may have positive pressure listings Frame Infmation Listings Maximum Wall Jamb Depth Maximum Do and Opening Width & Height Rating Application Series Min. Max. UL ITS/WHI FM 1-1/2 Hr Masonry F16, F14 4-3/4" 12-3/4" 4'0" x 11'0" 4'0" x 11'0" N/A (90 min) Masonry FN16, FN14 4-3/4" 12-3/4" 4'0" x 11'0" 4'0" x 11'0" N/A Max Masonry MU16, MU14 4-3/4" 12-3/4" 4'0" x 11'0" 4'0" x 11'0" N/A Stud F16, F14 4-3/4" 12-3/4" 4'0" x 11'0" 4'0" x 11'0" N/A Stud MU16, MU14 4-3/4" 12-3/4" 4'0" x 11'0" 4'0" x 11'0" N/A 1. Sizes may vary based on wood do manufacturer's listings. 2. 'F' series frames can be knocked down(kd) 3. 'MU' series must be shipped as welded units. 4. Maximum do size: Single dos = see wood do manufacturer's listing. Double dos = not approved 5. requirements: 1-3/4 thick wood panel. Maximum panel size = 4' 0" wide x 4' 0" high. panel installed with spring bolts requires reinfcing frame preparations. 6. Frame profile variations Perimeter (Head and Jambs) frame Masonry walls = minimum face 1" (FN) Stud walls = minimum face 1-1/4" Maximum face 4" masonry, steel wood stud walls. 7. Hardware applications: Single do - follow standard label requirements. 8. Refer to wood panel manufacturer s listing f spring bolt attachment into the frame. Transom Without Transom Bar Do Opening Dimension Transom Without Transom Bar Do Opening Dimension See Note # 8 F Attachment 9.4.4 Technical Data Manual Rev. 11/08

TRANSOM & SIDELIGHTS FIRERATEDPRODUCTS TRANSOM FRAME WITHOUT TRANSOM BAR (1-3/4 craft panel installed) NOTE - Listed f Neutral Pressure Frame Infmation Listings Maximum Do and Opening Width and Height Maximum Wall Jamb Depth UL & ITS/WHI Rating Application Series FM Min. Max. Single Dos Double Dos Masonry F16, F14 4-3/4" 12-3/4" 4'0" x 11'2" 8'0" x 11'2" N/A 3 Hr Max Masonry FN16, FN14 4-3/4" 12-3/4" 4'0" x 11'2" 8'0" x 11'2" N/A Masonry MU16, MU14 4-3/4" 12-3/4" 4'0" x 11'2" 8'0" x 11'2" N/A 1-1/2 Hr Stud F16, F14 4-3/4" 12-3/4" 4'0" x 10'0" 8'0" x 10'0" N/A (90 min) Max Stud MU16, MU14 4-3/4" 12-3/4" 4'0" x 10'0" 8'0" x 10'0" N/A 1. 'F' series frames can be knocked down(kd) 2. 'MU' series must be shipped as welded units. 3. Maximum do size: Single dos = 4080 Double dos = 8080 must swing in same direction 4. requirements: 1-3/4 thick steel panel Maximum panel size: Single dos = 48 wide X 48 high Double dos = 96 wide X 48 high 5. Frame profile variations Perimeter (Head and Jambs) frame Masonry walls = minimum face 1" (FN) Stud walls = minimum face 1-1/4" Maximum face 4" masonry, steel wood stud walls. 6. Hardware applications: Single do - follow standard label requirements. Double dos limited to flush bolts x single point latch Mtise FEH. 1-3/4 craft Without Transom Bard Flat Astragal Required Do Opening Dimension 1-3/4 craft Without Transom Bard Flat Astragal Required Do Opening Dimension Technical Data Manual Rev. 5/09 9.4.5

FIRERATEDPRODUCTS FIRE WINDOWS 9.4.6 Technical Data Manual Rev. 11/08