SECTION GROUND WATER STORAGE TANKS

Similar documents
SECTION GROUND STORAGE TANK

UNITED INDUSTRIES GROUP INC.

SECTION WELDED STEEL WATER STORAGE TANKS

Section SPHEROID ELEVATED WATER STORAGE TANK

Fencing, locks on access manholes, and other necessary precautions shall be provided to prevent trespassing, vandalism, and sabotage.

SPECIFICATIONS - DETAILED PROVISIONS Section Welded Steel Tanks for Water Storage C O N T E N T S

Tank Inspection Report Town of Christiansburg, VA Hills Tank Liquid Engineering Corporation 36903

SECTION SLUDGE HOLDING TANK DEWATERING

STEEL WATER STORAGE TANKS/SINGLE PEDESTAL

SECTION MISCELLANEOUS METALS

WATER STORAGE TANKS: INSPECTION METHODS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

STRUCTURAL STEEL FRAMING

SECTION STRUCTURAL METAL FRAMING

SECTION COLD-FORMED METAL TRUSSES

Marina Coast Water District Marina, CA Steel Reservoir #2

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY GROUND STORAGE. Section GROUND STORAGE TANK (GST) MODIFICATIONS, CLEANING AND DISINFECTION

SECTION FIRE HYDRANTS

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION ALUMINUM GEODESIC DOME. This section includes materials, fabrication and erection of the aluminum geodesic dome.

Stainless Steel Aeration Equipment Specification

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

Work Order Number *************************************************************************** SECTION C20 STAIRS 02/18

AMETank. Field Erected and Shop Built Storage Tanks Engineering Application Software

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

Environmental Process Control Field Report 8-Oct-14

SECTION ROOF ACCESSORIES

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

STANDARD SPECIFICATION FOR ALUMINUM FRAMING FOR RAILROAD PASSENGER SHELTERS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

THE WORLD LOOKS UP TO COMPOSITE ELEVATED TANK

Section COMPOSITE ELEVATED WATER STORAGE TANK

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

SECTION MISCELLANEOUS AND ORNAMENTAL IRON. *(Filed Sub-Bid Required) 1.00 TIME, MANNER AND REQUIREMENTS FOR SUBMITTING SUB-BIDS

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

SECTION METAL STAIRS

SECTION FACILITY ELEVATED, POTABLE-WATER STORAGE TANKS

Changes for the. TOHOPEKALIGA WATER AUTHORITY Standards, Specifications and Details

SECTION COMPOSITE METAL DECKING

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

SPECIFICATIONS - DETAILED PROVISIONS Section Bolted Steel Tanks for Water Storage C O N T E N T S

SECTION PRECAST CONCRETE MANHOLES

SPECIFICATIONS FOR HONEYCOMB INTERNAL FLOATING ROOFS

SECTION ROOF SPECIALTIES

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION CONSTRUCTION SERVICES

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

A World of Solutions Visit Composite Elevated Tank. Elevated Water Storage

SECTION METAL FABRICATIONS

Contents EN 14015:2004 (E) page

A. American Society for Testing and Materials (ASTM):

Prestressed Concrete Tanks. Design & Construction

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Reservoirs and Standpipes NOT FOR PRINT DISTRIBUTION. Water Storage. mcdermott.com

A. Access doors and frames are part of an access door and frame allowance.

DIVISION 5 METALS COLD FORMED METAL FRAMING Structural Metal Stud Framing

SECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

A World of Solutions Visit Reservoirs and Standpipes Water Storage

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it.

SECTION TAPPING SLEEVES AND VALVES

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

FIBERGLASS WET WELLS

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

1. Add new Section 02655: Chilled Water (CHW) Distribution System (added 30 September 2009)

Wastewater Capital Projects Management Standard Construction Specification

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

SECTION STRUCTURE MOUNT RAILING SYSTEM

HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

A. This Section includes steel cable trays and accessories.

1. Include plans, elevations, sections, details, and attachments to other work.

Steel Tank Structures. By Eric MacFarlane, SE, PE, LEED AP

SECTION LINEAR MOTION SLUDGE MIXERS

Tel. : , Fax : W.Site :

SECTION PLUMBING SPECIALTIES

Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

SECTION DUCTILE IRON FITTINGS. A. This section includes materials, installation, and testing of ductile iron fittings 48 inches and smaller.

VANGUARD Packed Column Air Stripping Tower Specifications

401 Sanitary Sewer System Design Criteria. The following additional design requirements shall also apply:

P.E. 4-1,000,000 12, 2014 (270) C

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

SECTION FIRE HYDRANTS

Section 32 - Miscellaneous

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION PUBLIC WATER SERVICE CONNECTIONS

***************************************************************************************************************

STORM DRAINAGE CHAPTER 11

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

Transcription:

SECTION 33 16 13 GROUND WATER STORAGE TANKS PART 1: GENERAL 1.01 SCOPE A. Section includes requirements for designing, fabricating, and erecting a welded steel ground storage tank. 1.02 SYSTEM DESCRIPTION A. Design Requirements 1. Design steel tank for capacity and dimensions as set forth in the Request for Proposals (RFP). 2. Layout of floor plates to be such that seams parallel to edges or intersecting with corners of concrete foundation or pipe encasement have 1-foot minimum spacing distance from these edges or corners. 3. Shell and floor plate thickness is ¼ inch minimum or required thickness determined by design plus 1/16 inch corrosion allowance whichever is greater. B. Design Requirements: 1. Tank design shall comply with AWWA Standard D100 and dimensions specified above. (i) Foundations shall be designed in accordance with AWWA D100 Section 12. (ii) Wind pressure shall be determined in accordance with AWWA D100 Section 3.1.4. (iii) Seismic Loads shall be determined in accordance with AWWA D100 Section 13. (iv) Snow load shall be determined in accordance with AWWA D100 3.1.3.1. 2. Perform welding in accordance with latest editions of applicable specifications of the American Welding Society. 3. Tank walls to be of butt welded construction. The roof is to be a stiffened, self supporting dome or umbrella type. Revised Jan 2018 33 16 13-1

1.03 SUBMITTALS Standard Specifications 4. Tank constructed so as to receive a stroke of lightning without damage as outlined by NFPA 780, Chapter 3 and 4. 5. Sewers, drains, standing water, and similar sources of possible contamination shall be kept at least 50 horizontal feet from the tank. 6. The area surrounding the tank shall be graded in a manner that will prevent surface water from standing within 50 horizontal feet of the structure. A. Shop Drawings: Submit shop drawings to the AW Project Manager where indicated. B. Tank and Foundation Drawings: Submit detailed drawings for steel tank and accessories and any foundation modifications to the AW Project Manager for approval before fabrication or erection is begun. Indicate on tank drawing whether design is based on AWWA D100 or on AWWA D100, Section 14- Alternate Design Basis for Standpipes and Reservoirs. Included with this submittal shall be details of all weld joints referenced in the above drawings, showing the plate edge preparation, the type of electrode, the number of weld passes and other information pertinent to each weld joint. C. Design Computations: Submit design computations for steel tank, accessories and foundation to the AW Project Manager for review before tank fabrication is begun. Design computations as submitted are to be certified by a Licensed Professional Engineer in the State in which the Project is located. AW Project Manager s review comments do not in any way relieve responsibility for accuracy and completeness of design. D. Radiograph/Welding Reports: Submit report of radiograph inspections and a welding report if design incorporated AWWA Standard D100 Section 14. E. Provide certification that the steel plates and structural members are manufactured in the United States and are free from inclusions of slag and other foreign matter and also free from heavy deposits of rust and/or pitting. F. Upon completion of erection of the tank, provide AW with a Notarized Certification of Compliance stating that the tank has been designed, fabricated, erected, inspected and tested in accordance with all of the requirements of AWWA Standard D100 and that the results of all inspection, radiographs and tests indicate that the tank is in full compliance with said AWWA Standard D100. Revised Jan 2018 33 16 13-2

PART 2 PRODUCTS 2.01 MATERIAL A. Tank Disinfection and Painting Systems 1. Provide tank disinfection in accordance with AWWA Standard C652 and Specification Section 33 16 13.11 Water Storage Tank Disinfection. 2. Provide tank painting conforming to Specification Section 09 97 00, Water Storage Tank Painting. 2.02 ACCESSORIES A. Roof Hatches (Two Required): 1) Provide two (2) hatches of minimum 24 inches square with a 4-inch neck and located near roof perimeter. Provide cover with hinges and a hasp on the outside. 2) Provide two (2) hatches of minimum 24 inches in diameter with a 4-inch flanged neck with gasketed and bolted cover. 3) The frame of any access opening shall be provided with a close fitting solid shoebox type cover which extends down around the frame at least 2 and is furnished with a gasket(s) between the lid and frame. 4) The lid to any access opening shall have a locking device. 5) Locate near center of roof with AW Project Manager s approval, and if the requirements of this hatch and roof vent can be incorporated into one opening, roof hatch and vent can be combined. B. Shell Manholes (three required): minimum 30-inch diameter, gasketed, bolted, and hinged on the outside. C. Bolting, Hasp and Hinge Material: Stainless steel bolting, ASTM A320 (Type 304), for all manholes, hatches and overflow piping. Hasps and hinges to be type 304 stainless steel. Provide gaskets of red rubber material. D. Overflow: 1. Overflows discharging between 12 and 24 inches above the ground surface shall include an appropriate air gap. All overflow pipes shall be screened with No. 24 mesh non-corrodible screen installed at a location least susceptible to damage by vandalism. 2. Overflow pipes shall not be connected to, or discharge into, any sanitary sewer system. Revised Jan 2018 33 16 13-3

3. 6 inch (min) diameter steel (½ inch wall in wet areas, ¼ inch wall in dry areas) or ductile iron overflow pipe and weir box to have a12,500 gpm minimum capacity with water level not more than 12 inches above the overflow elevation. 4. Minimum depth of weir box is 4.0 feet. Coat steel pipe inside and out as the tank. Coat ductile iron pipe exterior the same as the tank. Overflow dimensions may require adjustment for larger size storage tanks. 5. There shall be at least one opening above the water line which shall be framed at least 4 inches above the surface of the roof at the opening; or if on a buried structure, shall be elevated at least 18 inches above any earthen cover over the structure. 6. Overflows discharges shall not cause erosion. E. Ladders: Ladders having an unbroken length in excess of 20 feet shall be provided with appropriate safety devices. This requirement shall apply both to interior and exterior reservoir ladders. F. Vertical Outside Ladder with Safe-T-Climb Rail: Start 15 feet minimum above proposed grade. Provide aluminum vandal deterrent at base of ladder. Provide ladder no less than 16 inches wide with minimum 2 inch x 5/16 inch side rails, 7 inch minimum toe room and ¾ inch diameter minimum non-slip rungs. Rail members are to be galvanized material. Provide two Saf-T-Lock sleeves and harnesses. Construction shall comply with AWWA, OSHA, federal, state and local requirements. G. Roof Platform: Construct with steps and handrails on both sides to the point where the roof slope is 2 in 12 or less. From this point, provide stainless steel safety cable with support posts to the apex of the roof so personnel can remain tied-off while accessing the manhole and vent. The construction of the platform is to allow the stepped portion to be removed, such that the roof plate and platform underside is accessible for painting. Provide 4 x ¼ inch toe plate on all railing. Construction shall comply with AWWA, OSHA, Federal, State and local requirements. H. Roof Vent: A minimum of two roof vents shall be provided and protected with insect screens. Inverted vents shall be downturned a minimum of 2 inches below any opening or shielded to prevent the entrance of surface water and rainwater. Vents shall be fitted with No. 24 mesh or finer non-corrodible screen with additional heavy gage screen or substantial covering which will protect the No. 24 mesh screen against vandalism and contamination of the water. I. Grounding lugs. Provide four (4) equally spaced grounding lugs welded to base of shell. J. Tank Anchors and Anchor Chair: If required, quantity and location to be designed by the tank manufacturer. K. Steel Inlet/Outlet Piping: Provide steel (1/2-inch wall) or ductile iron inlet and outlet flanged piping as shown on the Drawings. L. Tank Drain: Provide separate tank drain pipe to a drain hydrant as shown on the Drawings. Revised Jan 2018 33 16 13-4

2.03 SOURCE QUALITY CONTROL A. AW reserves the right to perform shop inspection of materials and shop fabrication and painting procedures. Submit an accurate shop fabricating and painting schedule for all materials being furnished under this Section. The fabrication and shop painting schedule is required to be received by AW at least two (2) weeks prior to the start of any fabrication. Failure to notify AW in sufficient advance of these procedures is grounds for rejection of the materials. PART 3: EXECUTION 3.01 ERECTION A. Fabricate and erect tank in accordance with latest edition of AWWA Standard D100. B. Piping Connection: 1. Provide temporary pipe connection for the filling and testing of the tank. Make permanent pipe connections, after monitoring of settlement is complete, and the AW Project Manager has given approval to do so. 3.02 FIELD QUALITY CONTROL A. Inspection 1. At completion of welding, have at least one spot radiograph taken in the field on four sides of every plate below overflow elevation. Consider spot radiographs required by AWWA Standard D100 as a part of above requirements. 2. All bottom plates to be tested by air pressure or vacuum method in accordance with AWWA Standard D100. 3. Submit a report on radiograph inspections to Engineer. Report to include a layout sketch indicating location of radiographs with respect to plate edges, and Inspector s acceptance record for all radiographs. 4. If design incorporated AWWA Standard D100 - Section 14, submit the required welding report by a certified welding inspector. Include certificate to purchaser of compliance with AWWA inspection requirements under Section 14 with report. B. Settlement Check 1. Prior to filling tank, record elevations at quarter points along outside of foundation. Permanently mark points for future reference. Record elevations to within 0.01 ft. using the site benchmark from construction. Revised Jan 2018 33 16 13-5

2. Submit documentation of all elevations taken along with a foundation plan showing point locations, oriented to north and referenced to major tank appurtenances, sealed by a registered land surveyor licensed in the State in which the project is located. C. Leak Test 1. Check for leaks on tank surfaces during the filling process. Fix any leaks to the satisfaction of the AW Project Manager. END OF SECTION 33 16 13 Revised Jan 2018 33 16 13-6