Masonry Structures James Robert Harris, PE, PhD, and Fredrick R. Rutz, PE, PhD

Similar documents
Contents. 1.1 Introduction 1

Overview of Masonry Codes. Description

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2019 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Ce 479 Reinforced Masonry Fall 2005

Chapter 2 Notation and Terminology

Composite Steel/Concrete

VERIFICATION OF MASONRY DESIGN SOFTWARE NATIONAL CONCRETE MASONRY INSTITUTE PHASE III

MASONRY WALL DATA: Wall Height = ft. Nominal Wall Thickness = 8.00 in. Depth to c.g. Steel, Wall = 3.81 in.

Introduction to Masonry Materials and Assemblages

NCMA TEK DESIGN AND CONSTRUCTION OF DRY-STACK MASONRY WALLS TEK Provided by: Cinder & Concrete Block Corporation

REINFORCED ENGINEERING HANDBOOK CLAY AND CONCRETE MASONRY SEVENTH EDITION. John M. Hochwalt, PE, SE KPFF Consulting Engineers

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

NCMA TEK. TEK 14-5A Structural (2006) LOADBEARING CONCRETE MASONRY WALL DESIGN

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

2012 IBC/2011 MSJC MASONRY CODE COMPILATION

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

SEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

REINFORCED CONCRETE MASONRY SECTION

Masonry (Systematic Rehabilitation)

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

HISTORICAL REVIEW OF MASONRY STANDARDS IN NEW ZEALAND

Chapter 2 QUALITY ASSURANCE

CVEN 483. Structural System Overview

HYBRID CONCRETE MASONRY CONSTRUCTION DETAILS. TEK 3-3B Construction (2009) Related TEK: 14-9A

M A S O N R Y M A S O N R Y. Spring. Engineering Notes For Design With Concrete Block Masonry

Masonry and Cold-Formed Steel Requirements

Appendix M 2010 AASHTO Bridge Committee Agenda Item

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

3.5 Tier 1 Analysis Overview Seismic Shear Forces

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

Statement of Special Inspection Requirements

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: MMFX TECHNOLOGIES A COMMERCIAL METALS COMPANY

Characterization of Physical Properties of Roadware Clear Repair Product

S T R U C T U R. Technology. magazine. Software for the Structural Design of Masonry. The Design Basis. Copyright

4.6 Procedures for Connections

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Technical Notes 39A - Testing for Engineered Brick Masonry - Determination of Allowable Design Stresses [July/Aug. 1981] (Reissued December 1987)

Masonry Structural Design

UNREINFORCED MASONRY STRUCTURES -PART I - DEFINITIONS AND PROBLEMS UNDER LATERAL LOADS

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

Seismic Design of Precast Concrete Structures

THE EVOLUTION OF THE DESIGN AND CONSTRUCTION OF MASONRY BUILDINGS IN THE UNITED STATES

Kinds of Mortars. Mortar. Specifying Mortar. Proportion Specifications. M a S o N w O r K. Specification for Mortar Cement

Structural Performance of 8-inch NRG Concrete Masonry Units. Report Compiled for: Niagara Regional Group. Date: January 28, 2013

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Atkinson Engineering, Inc.

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Technical Notes 24C - The Contemporary Bearing Wall - Introduction to Shear Wall Design [Sept./Oct. 1970] (Reissued May 1988)

ANALYSIS OF BRICK VENEER ON CONCRETE MASONRY WALL SUBJECTED TO IN-PLANE LOADS. Thesis. Submitted to. The School of Engineering of the

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

Proposed Modification to the Florida Building Code

three design codes, building codes Structural Requirements Structure Requirements Structure Requirements serviceability efficiency

Chapter 21: Masonry 2003 INTERNATIONAL BUILDING CODE COMMENTARY 21-1

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

CONNECTOR B L O C K S H E A R. Design for Composite Structural Action BLOCK SHEAR CONNECTOR APPLICATION. Airspace

three design codes, building codes Structural Requirements Structure Requirements Structure Requirements serviceability efficiency

SHAKE-TABLE TESTING OF A 3-STORY, FULL-SCALE, REINFORCED MASONRY WALL SYSTEM

Building Code Requirements for Masonry Structures

10.5 ECCENTRICALLY LOADED COLUMNS: AXIAL LOAD AND BENDING.

CHAPTER 21 MASONRY SECTION

SECTION UNIT MASONRY

Chapter 7. Finite Elements Model and Results

Footings GENERAL CONSIDERATIONS 15.2 LOADS AND REACTIONS 15.4 MOMENT IN FOOTINGS

Modelling of RC moment resisting frames with precast-prestressed flooring system

UNION STATION EXPANSION AND RESTORATION

Special Civil Engineer Examination Seismic Principles Test Plan

SECTION UNIT MASONRY

three design codes, building codes APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2019 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Flexural Analysis and Design of Beams. Chapter 3

W. Mark McGinley March 3, 2016 ISEA MEETINGS 1

4.2 Tier 2 Analysis General Analysis Procedures for LSP & LDP

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

Seismic Design of Ductile Shear Walls

BS EN :2004 EN :2004 (E)

Special Reinforced Concrete Structural Walls

Technical Notes on Brick Construction Brick Industry Association Commerce Park Drive, Reston, Virginia 20191

Steel Design Guide Series. Steel and Composite Beams with. Web Openings

Modeling of Shear Walls for Nonlinear and Pushover Analysis of Tall Buildings

AIA Disclaimer Notice

10-COLUMNS: 10.1 Introduction.

ARCH 331. Study Guide for Final Examination

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

CONCRETE MASONRY VENEERS TEK 3-6C

Significant Changes to AWC s Special Design Provisions for Wind and Seismic

EVALUATION OF COLLECTOR DESIGN FOR CONCRETE DIAPHRAGMS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK )

ENGINEERED BRICK MASONRY STANDARDS

Chapter. Masonry Design

CHAPTER 21 MASONRY SECTION

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

DEFINITIONS AND NOTATIONS

SECTION 10. DESIGN FOR SHEAR

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Nelson Testing Laboratories

Transcription:

Masonry Structures James Robert Harris, PE, PhD, and Fredrick R. Rutz, PE, PhD Edited by David Sommer, PE, SE Includes materials originally developed by Richard Klingner, PE, PhD Disclaimer Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 1

SEISMIC DESIGN OF MASONRY STRUCTURES Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 2

NEHRP Recommended Provisions Masonry Structures: Reference standards Masonry basics Masonry behavior Organization of TMS 402 Code Types of shear walls Ductility provisions Masonry walls out-of-plane Shear wall in-plane design Simplified design for walltype structures Shear wall design example Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 3

NEHRP Recommended Provisions Masonry Design Basic Documents NEHRP Recommended Provisions ASCE 7-16, Minimum Design Loads for Buildings and Other Structures TMS 402-13, Building Code Requirements for Masonry Structures TMS 602-13, Specification for Masonry Structures IBC 2015, International Building code Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 4

NEHRP Recommended Provisions Masonry Design Masonry Basics Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 5

Review Masonry Basics Basic terms Units Mortar Grout Accessory materials Reinforcement, connectors, flashing, sealants Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 6

Basic Terms Bond patterns (looking at wall): head joints bed joints Running bond Stack bond 1/3 Running bond Flemish bond Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 7

Masonry Units Concrete masonry units (CMU): Specified by ASTM C 90 Minimum strength (net area) of 2000 psi (average) Net area 55% of gross area Nominal vs specified vs actual dimensions Type I and Type II designations no longer exist Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 8

Masonry Units Clay masonry units: Specified by ASTM C 62 or C 216 Usually solid, with small core holes If cores 25% net area, considered 100% solid Hollow units are similar to CMU - can be reinforced Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 9

Masonry Mortar Mortar specified by ASTM C 270 Three cementitious systems Portland cement + lime + sand ( traditional ) Masonry cement mortar (lime is included in cement) Mortar cement mortar (lime is included in cement, higher air contents) Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 10

Masonry Mortar Within each cementitious system, mortar is specified by type (M a S o N w O r K): Type K to Type M, increasing volume of portland cement. As the volume proportion of portland cement increases, sets up faster higher compressive and tensile bond strengths. mortar is less able to deform when hardened. Types M and S are specified for modern structural masonry construction. Type N for non-loadbearing and for brick veneer Type O or K for historic masonry repairs Specify by Proportion (preferred) or Property Onsite testing is not required Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 11

Masonry Mortar Plastic mortar properties Workability Important for good bond Water retentivity Rate of hardening Hardened mortar properties Bond Important, seldom specified Compressive strength Volume stability Durability Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 12

Grout Grout specified by ASTM C 476 Two kinds of grout: Fine grout (cement, sand, water) Coarse grout (cement, sand, pea gravel, water) ASTM C 476 permits small amount of hydrated lime. Lime usually not used in plant batched grout. Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 13

Grout Proportion of water not specified The slump should be 8 to 11 in. Masonry units absorb water from the grout High-slump grout will still be strong enough Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 14

Role of f m Concrete: Designer specifies value of f c Compression tests on cylinders cast in field Masonry Designer specifies value of f m Unit Strength Method or Prism Test Method Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 15

Application of Unit Strength Method (Specification Tables 1, 2) Designer determines required material specification: Designer states assumed value of f m Specifier specifies units, mortar and grout that will satisfy unit strength method Compliance with f m can be verified with no tests on mortar, grout, or prisms Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 16

NEHRP Recommended Provisions Masonry Design Masonry Behavior Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 17

Masonry Behavior Locally, masonry is nonisotropic, nonhomogeneous, and nonlinear. Globally, can be idealized as isotropic and homogeneous. Equivalent rectangular stress block. Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 18

Summary of Masonry Behavior 4-Way Composite Action Units, mortar, reinforcement, grout Compression High strength Brittle - low ductility Confinement difficult to achieve Tension Good strength when reinf. takes tension Very little strength without reinf. (continuous joints are a plane of weakness) Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 19

Design Implications from Masonry Behavior Unreinforced Design as elastic / brittle material R factors very low Design force = EQ force Reinforced Design similar to reinforced concrete Confinement, ductility difficult to achieve R factors lower than concrete Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 20

Masonry Behavior Head joint weakness Stacked bond - only mortar Running bond - half units Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 21

Masonry Behavior Crowded cells make grout flow difficult Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 22

Masonry Behavior: out-of-plane flexural strength anchorage Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 23

NEHRP Recommended Provisions Masonry Design Organization of TMS 402 Code Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 24

Organization of 2013 TMS 402 Code Part 1, General Chapters 1-3 Part 2, Design Requirements Chapters 4-7 (Analysis and Design, Elements, Reinforcement, Seismic) TMS 602 Specification Appendices A, B, and C Part 3, Engineered Design Methods Chapters 8-11 Part 4, Prescriptive Design Methods Chapters 12-14 Ch. 8, Allowable Stress Design Ch. 9, Strength Design Ch. 10, Prestressed Masonry Ch. 12, Veneer Ch. 13, Glass Block Ch. 14, Partitions 8.1, General ASD 8.2, URM 8.3, RM 9.1, General SD 9.2, URM 9.3, RM Ch. 11, AAC 6.1, General 6.2, Anchored 6.3, Adhered Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 25

Organization of 2013 TMS 602 Specification TMS 402 Code TMS 602 Specification Part 1 General Part 2 Products Part 3 Execution 1.6 Quality assurance 2.1- Mortar 2.2 - Grout 2.3 - Masonry Units 2.4 - Reinforcement 2.5 - Accessories 2.6 - Mixing 2.7 - Fabrication 3.1 - Inspection 3.2 - Preparation 3.3 - Masonry erection 3.4 - Reinforcement 3.5 - Grout placement 3.6 - Prestressing 3.7 - Field quality control 3.8 - Cleaning Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 26

Organization of TMS 402 Code Part 1 General Chapter 1 1.1 Scope 1.2 Contract documents and calculations 1.3 Special systems 1.4 Reference standards Chapter 2 2.1 Notation 2.2 Definitions Chapter 3 3.1 Quality assurance program 3.2 Construction Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 27

Organization of TMS 402 Code Part 2 Design Requirements Chapter 4 4.1 Loading 4.2 Material properties 4.3 Section properties 4.4 Connections to structural frames 4.5 Stack bond masonry Chapter 6 6.1 Details of reinforcement 6.2 Anchor bolts Chapter 7 Seismic design requirements Chapter 5 5.1 Masonry assemblies 5.2 Beams 5.3 Columns 5.4 Pilasters 5.5 Corbels Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 28

Code 4.2, Material Properties Prescriptive modulus of elasticity: Em = 700 f m for clay masonry Em = 900 f m for concrete masonry or Chord modulus of elasticity from tests Shear modulus, thermal expansion coefficients, and creep coefficients for clay, concrete, and AAC masonry Moisture expansion coefficient for clay masonry Shrinkage coefficients for concrete and AAC masonry Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 29

Code 4.3, Section Properties Use minimum (critical) area for computing member stresses or capacities Capacity is governed by the weakest section; for example, the bed joints of face-shell bedded hollow masonry Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 30

Chapter 7, Seismic Design ASCE 7-16 General Structural Integrity: Load path connections Notional lateral forces Connection to supports Anchorage of walls Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 31

Chapter 7, Seismic Design General analysis Drift limits: Use legally adopted building code or ASCE7 Drift limits assumed satisfied for many wall types Special Reinforced Masonry walls are the exception to this rule Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 32

Chapter 7, Seismic Design Seismic Design Category C: Empirical and plain not permitted All other types of shear walls permitted: Ordinary reinforced Intermediate reinforced Special reinforced Participating walls shall be reinforced Non-participating walls - minimum prescriptive reinforcement At least 80% lateral resistance in a line from shear walls Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 33

Chapter 7, Seismic Design Seismic Design Category D: Only special reinforced shear wall permitted Minimum prescriptive requirements for reinforcement and connections Type N mortar and masonry cement mortars are prohibited in the lateral force-resisting system Non-participating walls - minimum prescriptive reinforcement Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 34

Chapter 7, Seismic Design Seismic Design Category D: Extra caution against brittle shear failure for Special Reinforced Masonry Shear Walls (7.3.2.6.1.1): fv n > 1.25M n or fv n > 2.5V u Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 35

Chapter 7, Seismic Design Seismic Design Categories E and F: Additional reinforcement requirements for nonparticipating stack-bond masonry Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 36

Minimum Reinforcement for Special Reinforced Shear Walls roof connectors @ 48 in. max oc roof diaphragm #4 bar (min) within 16 in. of top of parapet Top of Parapet #4 bar (min) within 16 in. of corners & ends of walls #4 bars around openings 24 in. or 40 db past opening #4 bar (min) @ diaphragms continuous through control joint #4 bar (min) within 8 in. of all control joints control joint r total both ways = 0.002 Min. #4 bars @ 4 ft oc max. Min. #4 bars @ 4 ft oc max. or W1.7 @ 16 in oc Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 37

Minimum Reinforcement, SW Types SW Type Empirically Designed Minimum Reinforcement none Permitted in SDC A Ordinary Plain none A, B Detailed Plain Ordinary Reinforced Intermediate Reinforced Special Reinforced Vertical reinforcement = #4 at corners, within 16 in. of openings, within 8 in. of movement joints, maximum spacing 10 ft; horizontal reinforcement W1.7 @ 16 in. or #4 in bond beams @ 10 ft same as above same as above, but vertical reinforcement @ 4 ft same as above, but horizontal reinforcement @ 4 ft, and r 0.002 (sum of horiz + vert) A, B A, B, C A, B, C A,B,C,D, E, F Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 38

Organization of TMS 402 Code Chapter 9, Strength Design Fundamental basis Design strength f factors Deformation requirements Anchor bolts Bearing strength Compressive strength Modulus of rupture Strength of reinforcement Unreinforced masonry Reinforced masonry Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 39

Fundamental Basis for Strength Design fq n > gq u Load factors come from ASCE 7 Resistance factors (f) come from TMS 402 g / f F.S. from ASD Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 40

Code 9.1.4, Strength-reduction Factors (f) for Strength Design Action Reinforced Masonry Unreinforced Masonry combinations of flexure and axial load 0.90 0.60 shear 0.80 0.80 bearing 0.60 0.60 Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 41

Code 9.3, Reinforced Masonry Masonry in flexural tension is cracked Reinforcing steel is needed to resist tension Similar to strength design of reinforced concrete Compressive reinforcement ignored unless tied in compliance with 5.3.1.4 Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 42

Code 9.3.2, Design Assumptions Continuity between reinforcement and grout Equilibrium mu = 0.0035 for clay masonry, 0.0025 for concrete masonry Plane sections remain plane Elasto-plastic stress-strain curve for reinforcement Tensile strength of masonry is neglected Stress block height of 0.80f m and depth of a = 0.80c Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 43

Code 9.3.3.5, Maximum Reinforcement (Flexural Ductility Check) Does not apply if M u /V u d <1.0 and R 1.5 Locate neutral axis based on extremefiber strains s =a y Calculate compressive force, C (may include compressive reinforcement) Reinforcement f y T C Tensile reinforcement + axial load = C mu = 0.0035 clay 0.0025 concrete 0.80 f m a = 1.5 Ordinary 3 Intermediate 4 Special Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures 12-44

Code 9.3.4, Nominal Shear Strength V n = (V nm + V ns )g g V n shall not exceed: M u / V u d v 0.25 V n 6 A n f m M u / V u d v 1.0 V n 4 A n f m Linear interpolation between these extremes Objective is to avoid crushing of diagonal strut Objective is to preclude critical (brittle) shearrelated failures g g = 1.0 for fully grouted walls = 0.75 for partially grouted walls Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 45

Code 9.3.4, Nominal Shear Strength V m and V s are given by: M u V = 4-1.75 A f 0.25 P Vd u v nm n m u V v 0.5 A s f d ns y v (9-24) (9-25) Empirical from research Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 46

Code 9.3.5, Design of Walls for Out-of-Plane Loads Maximum reinforcement by Code 9.3.3.5 Procedures for calculating P d effects using iteration or a moment magnifier Note 9.3.5.4.2 M and D equations are based on simple supports top & bottom Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 47

Code 9.3.6, Design of Walls for In-plane Loads Design assumptions of Code 9.3.2 apply Interaction diagram: P n max. per ductility requirement P n pure compression Excluded portion non-ductile balance point M n pure flexure Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 48

NEHRP Recommended Provisions Masonry Design Simplified Design for Wall-type Structures Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 49

Essential Function of Walls in Resisting Lateral Forces Walls parallel to lateral forces act as shear walls Bond beams transfer reactions from walls to horizontal diaphragms and act as diaphragm chords Vertical strips of walls perpendicular to lateral forces resist combinations of axial load and out-ofplane moments, and transfer their reactions to horizontal diaphragms Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 50

Design of Vertical Strips in Perpendicular Walls Moments and axial forces due to combinations of gravity and lateral load M = P e ~ M = P e / 2 M wind, eq Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 51

Component Design: Design of walls Out-of-plane forces, F p Out-of-plane bending and shear Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 52

Component Design basics beff = 6t < - s < - 72 s s T - beam section assumed to resist out-of-plane flexure (Masonry laid in running bond) Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 53

Design Flexural Reinforcement as Governed by Out-of-plane Loading Practical wall thickness is governed by available unit dimensions: 8- by 8- by 16-in. nominal dimensions is most common Specified thickness = 7-5/8 in. One curtain of bars, placed in center of grouted cells Can have nominal 6 through 12 Proportion flexural reinforcement to resist out-ofplane wind or earthquake forces Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 54

Distribution of Shears to Shear Walls Classical approach Determine whether the diaphragm is rigid or flexible Carry out an appropriate analysis for shears Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 55

In-plane force Component Design basics Force distributed according to relative stiffness Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 56

Design Flexural Reinforcement as Governed by In-plane Loading Construct moment axial force interaction diagram Initial estimate Computer programs Spreadsheets Tables Axial Capacity Flexural Capacity Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 57

Check Shear Capacity V n = (V nm + V ns )g g V nm depends on (M u / V u d v ) ratio V ns = (0.5) A v f y (note efficiency factor when combining V nm and V ns ) g g = 1.0 for fully grouted walls V A v f y 45 o Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 58

Procedure for Strength Design of Reinforced Masonry Shear Walls Select trial design Compute M u and V u for in- and out-of-plane loading Include p-d for out-of-plane moment Design reinforcement for out-of-plane loading Design reinforcement as controlled by in-plane loading Revise design as necessary Check to ensure ductility Check shear capacity and revise if required Check detailing Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures 12-59

Design Example Refer to NEHRP Design Examples (FEMA P-751) Ch. 13, Masonry Shear Wall: Next slide Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 60

Design Example Shear Wall Refer to NEHRP Ch. 13, Masonry Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 61

11.63" Design Example P M Refer to NEHRP Ch. 13, Masonry 96" 48" 44" 4".8 f 'm Trial design: (6) cells w/ (2) #6 42.35' 36" 12" 12" Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 62

Design Example Ductility Check Refer to NEHRP Ch. 13, Masonry Note: a = 4 for Special Reinforced Masonry Shear Wall Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 63

Design Example Ductility Check (cont.) Refer to NEHRP Ch. 13, Masonry Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 64

Design Example Ductility Check (continued) C > T + P Cm + Cs1 + Cs2 > Ts1 + Ts2 + Ts3 + Ts4 + P 315.5 + 53.6 + 28.1 > 52.8 + 52.8 + 52.8 + 43.4 + 45.1 397 kips > 247 kips OK OK because comp capacity > tension capacity Refer to NEHRP Ch. 13, Masonry Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 65

Design Example Refer to NEHRP Ch. 13, Masonry P = 0 Case Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 66

Design Example Refer to NEHRP Ch. 13, Masonry Balanced Case Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 67

Design Example Refer to NEHRP Ch. 13, Masonry Pn = C - T = 534 kips fpn = (0.9)(534) = 481 kips Mcl = 0: Mn = 23,540 in.-kips fmn = (0.9)(23,540) = 1,765 ft-kips Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 68

Design Example Refer to NEHRP Ch. 13, Masonry fmn 600 kips 500 kips Mu = 523 ft-kips ɸM Mu n = 1096 ft-kips Balance: (1765 ft-kips, 481 kips) 400 kips fpn 300 kips Simplified fpn - fmn curve 200 kips 100 kips P u,min = 41 kips P u,max = 67 kips P = 0 (988 ft-kips, 0 kips) fpn max for ductility = 223 kips 500 ft-kips 1,000 ft-kips fmn 1,500 ft-kips 2,000 ft-kips Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 69

Web sites for more information BSSC = https://www.nibs.org/?page=bssc TMS = www.masonrysociety.org ACI = www.concrete.org ASCE / SEI = www.seinstitute.org NCMA = www.ncma.org BIA = www.bia.org Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 70

Acknowledgements This presentation was adapted from material prepared by Prof. Richard E. Klingner, University of Texas at Austin and by Dr. James Harris, J.R. Harris & Co. Some of the material originally prepared by Prof. Klingner was for a US Army short course. Some of the material originally prepared by Prof. Klingner was for The Masonry Society and is used with their permission. The material originally prepared by Dr. Harris was for FEMA, The Building Seismic Safety Council, and the American Society of Civil Engineers. Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 71

Questions? dsommer@degenkolb.com Instructional Material Complementing FEMA P-1051, Design Examples Design of Masonry Structures - 72

DISCLAIMER NOTICE: Any opinions, findings, conclusions, or recommendations expressed in this publication do not necessarily reflect the views of the Federal Emergency Management Agency. Additionally, neither FEMA nor any of its employees make any warranty, expressed or implied, nor assume any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, product or process included in this publication. The opinions expressed herein regarding the requirements of the NEHRP Recommended Seismic Provisions, the referenced standards, and the building codes are not to be used for design purposes. Rather the user should consult the jurisdiction s building official who has the authority to render interpretation of the code. Any modifications made to the file represent the presenters' opinion only.