STONE INSTALLATION GUIDE

Similar documents
Installation Guide Wall Panels

MOUNTAIN STONE Products

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. RobinsonBrick.com

TABLE OF CONTENTS IMPORTANT INFORMATION. INSTALLATION GUIDELINES Revised 5/5/2017 REFERENCES...2

PART 1-SAWN THIN VENEER GENERAL

GENERAL SHALE NATURAL THIN ROCK VENEER Installation Guide. GeneralShale.com

CAPTURED STONE IMPRESSIONS' INSTALLATION GUIDE FOR MANUFACTURED STONE VENEER

Manufactured Stone Veneer Installation Guide

Thin Architectural Splitface Block Veneer Specification Guide

HammerStone Manufactured stone veneers for commercial & residential applications

Installation Guidelines for Adhered Natural Thin Stone Veneer

Hardscaping Installation Manual

Rectangular Area: 15 x 10 = 150 sq ft Triangular Area: 15 x 5 x ½ = 38 sq ft

Stone and Masonry Veneer

SECTION Fiber Reinforced Stucco 1

INSTALLATION MATERIALS

TABLE OF CONTENTS OUR COMPANY. OUR PRODUCTS Popular Simulated Stone Styles Limestone - Rustic Ledgestone - Stacked Stone

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

Application Instructions

SPECIFICATION GUIDELINE

Installation Guidelines for Adhered Concrete Masonry Veneer

INSTALLATION GUIDE THE BEST PANEL COMPANY. 126 Old Highway 60 E Hardinsburg, KY Office: Rev.

SPECIFICATION GUIDELINE

Installation Guide and Detailing Options for Compliance with ASTM C1780. For Adhered Manufactured Stone Veneer 5 Edition, 1 Printing

ICC-ES Evaluation Report Reissued November 2014 This report is subject to renewal November 2016

STONEWRAP MANUFACTURED STONE VENEER - LUXURY MANUFACTURED STONE

Installation Guide and Detailing Options for Compliance with ASTM C1780. For Adhered Manufactured Stone Veneer 5 Edition, 1 Printing

BALLISTIC RESISTANT PLASTER ON CMU

Brick Masonry. Best Practices Guide

Inspection Fundamentals: Stucco & EIFS

WEIGHT PER PIECE (LBS.)

2019 IAQA Annual Meeting

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

Makers of Premium Manufactured Stone STONE FOR THE AGES THE MARK OF EXCEPTIONAL VALUE

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

MANUFACTURER S INSTALLATION INSTRUCTIONS

CONCRETE STAIRS Note:

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

installation guidelines

Ultrakote Cementitious Finish System

GA APPLICATION OF GYPSUM SHEATHING

GYPSUM BOARD AND PLASTER

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

manufacturer s installation instructions - methods to comply with ASTM C1780

Installation Guide. for Adhered Concrete Masonry Veneer

Product Guide Specification

Installation Guide and Detailing Options for Compliance with ASTM C1780. for Adhered Manufactured Stone Veneer 4 th Edition 5 th Printing

Gold Bond BRAND Gypsum Sheathing

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

Finestone Stucco Ultra Wall System

Never use wire brushes, acid cleaners, power washers, bleach, paint remover or any other type of concrete cleaner.

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

application instructions

Installation Guide and Detailing Options for Compliance with ASTM C1780

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

Phone Fax

Installation Standard For TILE-LINED ROMAN BATH TUBS IAPMO IS (10) Wall Finish. (3) Test Required. (2) Waterproof. Tile. (8) Concrete Shell

1. WHAT IS THE DIFFERENCE BETWEEN 16/20, 20/30, MONTALVO, AND SANTA BARBARA FINISH?

LP SmartSide Perfection Shingle

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Commercial Flashing Details

Guide Specification for the OSI QUAD Window and Door Flashing System

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH

CTIOA Field Report 82-2

DIVISION 9 SECTION 09220

SRP-AirOutshield UV Issued:

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

Product and System Specifications DuPont Flashing Systems

Frequently Asked Questions

The better way to build TM. Installation Manual NAILBASE PANELS

PATENTED. StoneFit Wall System WITH DRYFIT TECHNOLOGY

XTREME-BOND INSTALLATION SYSTEM

DUPONT TYVEK MECHANICALLY FASTENED AIR AND WATER BARRIER INSTALLATION GUIDELINES FOR BUILDINGS GREATER THAN 4 STORIES AND HIGH PERFORMANCE

g e m s t o n e MediaWall

CTIOA REPORT

DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines

Installation Instructions Tuscan Field Applied Limestone Finish

PART 1 GENERAL MANUFACTURED STONE MASONRY

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

Installation Guide & Helpful Tips

R-Matte Plus-3: Insulation for the Building Envelope

SECTION UNIT PAVERS

Ultra Wall System. CAD Detail Sets

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

Jewel Stone. Decorative Concrete Overlay System. Part 1 GENERAL MANUFACTURER S SPECIFICATION

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

Siding and Soffit Installation Guidelines

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

Multi-Institutional Academic Health Science & Research Center Evansville, IN

DuPont Tyvek Wall Underlay Install Guide

SECTION PORTLAND CEMENT PLASTERING

Transcription:

STONE INSTALLATION GUIDE

TOOLS NEEDED 1. Staple/Nail gun 2. Metal Shears 3. Measuring Tape 4. Masonry Hammer 5. Wheelbarrow 6. Pointed shovel 7. Mortar hoe 8. 12" rectangular trowel 9. Pointed trowel 10. Nippers 11. 4' level 12. Grout bag 13. Tuck pointer 14. Plastic bristled brush or whisk broom 15. Gloves 16. Dust Mask 17. Safety Glasses 18. Wet or Circular Saw with Carbide or Diamond Tip Blade STEP 1: Determining the Surface ProVia s stone products may be applied to any structurally sound load bearing wall surface. Non-load bearing walls may require alterations and we recommend you consult with a construction engineer. ProVia s stone may be applied directly to clean untreated porous concrete and masonry surfaces. Backup Wall System Sheathing/ Substrate Water Resistive Barrier * Walls/surfaces must be clean and free from release agents, paints, stains, sealers or other bond-break materials that may reduce strength of mortar adhesion. NOTE: The most current information available at www.masonryveneer.org. Lath Type Lath Fasteners Setting Bed/Scratch Coat Concrete or CMU* Not Applicable Optional Optional Not Applicable See Mortar Table in Material Specs Exterior Wood or Steel Stud Framing; maximum spacing 16 in. (406 mm) Coursed Brick or Stucco Gypsum Wall Board Plywood OSB Fiber Board Cement Board Minimum two layers WRB *Optional for interior use Any approved lath Not Applicable Optional Any approved lath Corrosion resistant; minimum penetration 3 4 in. (19 mm) into wood framing member or 3 8 in. (10 mm) into steel framing member Corrosion resistant concrete screws, masonry nails, or powder actuated fasteners See Mortar Table in Material Specs See Mortar Table in Material Specs 2

Wood and Concrete Applications Concrete Wall Lath (where necessary) Lath Fasteners - Type & Spacing Per ASTM C1063 Scratch Coat "Back-butter" the back of the stone with mortar before attaching to the scratch coat. Manufactured Stone Mortar Joint Weep Screed (where necessary) Wood Substrate Two Layers of WRB Lath Scratch Coat Lath Fasteners - Type & Spacing Per ASTM C1063 "Back-butter" the back of the stone with mortar before attaching to the scratch coat. Manufactured Stone Mortar Joint WRB Lapped Over Weep Screed Weep Screed 3

STEP 2: Preparing the Surface Proper surface preparation is important for adhesion and keeping water infiltration to a minimum. Walls/surfaces must be clean and free from release agents, paints, stains, sealers or other bond-break materials that may reduce strength of mortar adhesion. Flashing, Casing Bead & Flashing Tape - a thin piece of material to prevent the passage of water into a structure from a joint. All flashing and flashing accessories must be corrosion resistant and integrated with the Water Resistant Barrier materials (if present). For exterior applications, flashing must be installed at all through-wall penetrations and at terminations of adhered manufactured stone veneer (ASMV) installations. One layer of house wrap covered by one layer of Water Resistant Barrier is acceptable. Flashing is not required for interior applications not exposed to water. Flashing - Preparing opening Make angle cuts at corners and fold up flap Sealant along head and sides only Extend up 6" Turn up 6" Patch corners Use moldable flashing, or cut and fold to form sill pan Peel-and-stick flashing tape 1. Cut modified "H" in housewrap 2. Install pan flashing and sealant 3. Install window and side flashings Seal tape to sheathing 4. Apply head flashing 5. Tape cuts over head flashing 6. Tape bottom of opening over 2 nd layer of WRB 4

Flashing - Inside corner Water Resistant Barrier 1 Water Resistant Barrier 2 Flashing, Flashing Tape or Casing Bead Flashing - Outside corner Water Resistant Barrier 1 Water Resistant Barrier 2 Flashing, Flashing Tape or Casing Bead Flashing - Adjacent material Water Resistant Barrier 1 Water Resistant Barrier 2 Flashing, Flashing Tape or Casing Bead 5

Flashing - Vertical Transition at a cased opening Water Resistant Barrier 1 Water Resistant Barrier 2 Casing Bead Flashing - On porch and stairs Water Resistant Barrier 1 Water Resistant Barrier 2 Flashing or Flashing Tape 6

Flashing - Header installation Water Resistant Barrier 1 Water Resistant Barrier 2 Flashing - adds strength and rigidity to the structure in addition to providing a matrix to which the mortar can adhere. Lath should be applied horizontally across the wall. Metal lath should be applied horizontally (perpendicular to framing, if present) per manufacturer s instructions, and should overlap a minimum of 1" (25mm) at the vertical seams and a minimum of 1 2" (13mm) at the horizontal seams. Inside and outside corners should be wrapped a minimum of 16" to the next stud (do not end lath at the corner of framing). 7

STEP 3: Applying the Scratch Coat Scratch Coat - The purpose of the scratch coat is to create a surface to which the stone can stick. Stone will not stick to bare wood. Mix thoroughly the appropriate mortar (refer to "Mortar" table in Material Specs) in a wheelbarrow using pointed shovel. Add approximately 2½ gallons clean, potable water to achieve a trowelable mixture. Spread mixture evenly over metal lath approximately 3 8" to 1 2" thick. After mortar is thumb print dry, scratch or score the surface horizontally to create a rough scratch coat that ensures a good bond when the stone is applied. STEP 4: Applying the Stone Corners and Flats If corner pieces are required, set them first by alternating the short and long leg of the corners on the wall. If the stone will not be grouted, they should be applied from the bottom up. If the stone is to be grouted, installation from the top down is best to keep the face of the stones clean. Install flat pieces starting from the corner pieces and work towards the center of the wall. Start at the top and work sideways and down to keep stones clean. Horizontal lines should be broken approximately every 6'. The presence of moisture is important to achieve good adhesion. Because of this, you may need to moisten the back of the stone along with the scratch coat so that the surface is damp, but free of standing water to ensure good adhesion. Using the same mixture as the bed/scratch coat, apply approximately ½" of mortar, covering the entire back of the stone. By using gentle pressure and a slight wiggling action while applying the stone to the bed/scratch coat, you will assure a good bond. The stone installation must achieve a minimum of 50 lbs. per sq. inch shear bond*. All cuts should be installed with the cut facing away from the entrance. Blend stones of different shapes and colors to achieve a desirable look. Where freeze/thaw conditions are rare, stone can be installed to grade. However, unwarrantable discoloration of stone touching the ground may occur. Where freeze/thaw conditions are common, stone should be installed a minimum of 2" above surfaces. This minimum can be reduced to 1 2" if the surface is a walking surface supported by the same foundations supporting the wall. * Check with the mortar manufacturer to ensure their mortar meets or exceeds ASTM C 91 requirements and meets minimum bond code requirements Walking surface supported by the same foundation Non-walking surface Joint Spacing The recommended grout joint of 5 8 inch will ensure 10 square foot wall coverage for most profiles, for more details visit ProVia.com. Actual grout joint may differ according to the installer s discretion. It is essential that the entire back of each stone be encapsulated with mortar to ensure a good bond. Dry Stacked Applications The stones should fit tightly against each other, however due to the unique shape of each stone, some gaps between stones may occur. If gaps between stones is a possibility, it is recommended to use a complimentary color mortar. It is essential that the entire back of each stone be encapsulated with mortar to ensure a good bond. Dry stacked applications are not recommended where freeze/thaw is common. 8

STEP 5: Grouting Finish Joint Procedure: Brushing Joints: Tip: The mortar should be firm enough not to stain stone. If the mortar is struck prematurely, the joint will look like toothpaste or appear creamy, wait for the mortar to dry more. Tip: Start at the top and work down to ensure a clean finish. Grouting the joints should be completed only after there is sufficient cure time of the manufactured stone. Grouting may be done with a grout bag, filling joints to the desired depth, ensuring that mortar is forced into all voids. Grout should be "thumb-print" hard before tooling the joints. When the desired firmness is reached, the use of a wooden striking tool carved just a little smaller than the joint width or metal margin trowel may be used. Press gently and smoothly as to fill grout voids and remove excess mortar to desired depth. When using a metal margin trowel, the joint must be scratched after striking to roughen joint surface. This can be achieved by turning the metal striking tool over and using the tip to scratch the joint. Brushing should be done within 2 hours after tooling the joints. The best way is with a clean whisk broom or any plastic bristled brush. Do not use a metal bristled brush. Do not let mortar set overnight before tooling or brushing and do not brush wet mortar, as it will smear. For more grouting techniques, visit provia.com/manufactured-stone/installation. Cleaning: Do not pressure wash, sandblast, use wire brushes or acids for cleaning. Instead, wet the wall thoroughly with water. Next, scrub the wall with tri-sodium phosphate solution using a stiff plastic bristled brush. Then, rinse the wall thoroughly. If you need further assistance, contact your dealer or Customer Service at 800.669.4711. Sealing: Sealing is unnecessary and an additional expense on most projects. However, a sealed surface is much easier to clean than an unsealed surface. If you have conditions that could discolor or stain the stone, sealing is an option that you may want to consider. Contact your dealer or Customer Service at 800.669.4711 for assistance. 9

Material Specs Water Resistive Barrier No. 15 felt complying with ASTM D226 for type 1 felt (15 pound felt is not the same product as No. 15 felt) Complying with ASTM E2556/E2556M Combination of two materials meeting these requirements Lath 2.5-3.4lb/yd self-furred metal lath meeting the requirements of ASTM C 847 18-gauge woven wire mesh meeting the requirements of ASTM C1032 Welded wire lath meeting the requirements of ASTM C933 Fasteners Corrosion resistant staples, nails, and screws complying with ASTM C1063 Masonry or concrete walls Corrosion resistant - Concrete Screws - Powder Actuated Fasteners Wood framing 3 4 inch minimum penetration depth - Staples, Roofing Nails, Screws and Washers Metal framing 1 inch minimum penetration depth - Screws Weep Screeds and Casing Beads Minimum vertical attachment flange of 3.5 inches terminating behind WRB Metal - Thickness must be no less than 0.0179 inches (26 gage) Plastic - Thickness must be no less than 0.050 inches (1.3mm) Mortar Application 1 If the surface area of an AMSV unit exceeds 1 ft 2 (0.1 m 2 ) or 24 in (610 mm) in any dimension, then install using setting bed mortar complying with ANSI A118.4 or ANSI A118.15. 2 Requires a minimum nominal mortar joint thickness of 1 4 in (6.4 mm) around AMSV units. 3 Requires a fastening system designed by a professional engineer. AMSV units should not be subjected to pedestrian or vehicular traffic. NOTE: The most current information available at www.masonryveneer.org. Application Based Setting Bed Mortar Recommendations 1 Type N Mortar Type S Mortar (ASTM C270 or ASTM C1714) (ASTM C270 or ASTM C1714) or ANSI A118.1 Mortar ANSI A118.4 or ANSI A118.15 Mortar Interior Applications Less than 10 ft (3 m) in height above finished floor Recommended Recommended Recommended All other interior applications Not Recommended Recommended Recommended Exterior Single Family Residential Applications Grouted 2 Not Recommended Recommended Recommended All other exterior single family residential applications Not Recommended Recommended Recommended Exterior Commercial Applications Less than 10 ft (3 m) in height above finished grade Not Recommended Recommended Recommended All other exterior commercial applications Not Recommended Not Recommended Recommended Special Applications Installed directly on cement board Not Recommended Not Recommended Recommended Non-vertical applications 3 Not Recommended Not Recommended Recommended 10

TIPS & SUGGESTIONS Caution Do not subject AMSV to direct or frequent water contact. For example, avoid allowing sprinklers to directly spray onto the surface. Also, downspouts or drainage pipes should be placed so that water is not frequently moistening the AMSV units. Do not subject AMSV to contact with de-icing materials, salt, or other harsh chemicals. Prolonged exposure to these conditions may discolor the AMSV or result in surface damage. NOTE: For more detailed installation instructions, visit our website www.provia.com Darker looking Stone ProVia s stone is packaged before the drying process is complete. As with natural stone, ProVia s stone will look darker if moisture is present. Therefore, examine the stone for moisture and if in doubt, place a few stones on an oven rack, in the middle of an oven at 160 degrees, for several hours. Allow them to cool before removing from the oven. The stone will lighten to its true color as moisture dissipates. If not, contact ProVia Customer Service. Draining Plane Systems ProVia s stone does not require the use of rain screen drainage plane systems although some building codes require this. Reference the MVMA Installation guidelines at https://ncma.org/manufactured-stone-veneer/ Efflorescence A white residue that sometimes appears on masonry surfaces. As moisture makes its way through concrete, from the inside out, it may bring with it any soluble salts residing in the concrete or mortar. When the moisture evaporates, it leaves the soluble salts on the masonry surface. To clean efflorescence off a masonry surface, mix 1 part white vinegar to 5 parts clean water. With a soft bristled brush lightly scrub the masonry surface with the water/vinegar mixture. Do not use acids, power washing equipment or other cleaning agents to remove efflorescence. Expansion/Control Joints Do not span expansion or control joints with stone. Terminate stone at the expansion or control joint. These exist to relieve pressure and allow for movement in the structure. Flashing No weep screed is needed where there is flashing. To prevent leaks place Z-flashing above all openings in the stone area. Use flashing above brick instead of weep screed. Stains Paint use artists echo knife (looks like a scalpel). Gently lift paint splatter off. Coffee scrub with tri-sodium phosphate solution, rinse with water and cover with cat litter. Oil put paint thinner on the stain, scrub with small soft brush, cover with cat litter, flour or corn meal. Repeat process until stain is gone. For situations or applications not outlined in this manual, please refer to the most current edition of the MVMA Installation Guide and detailing options for compliance with ASTM C1780. 11

To serve, by caring for details in ways others won t. It s not just our mission, but a way of letting our light shine every day at ProVia. We continually strive to put these words into action by providing unmatched quality and service. The P-icon symbolizes each employee s commitment to devoting the utmost care, pride and quality into each building product we manufacture it s The Professional Way. Doors Windows Siding Stone provia.com 2018 ProVia Z-MK-10018-18 6/18