Millex -GV Sterilizing Filter Unit

Similar documents
Ultrafree -CL Centrifugal Filter Units. Single-Use Only

Thermo Scientific Syringes and Filters

GE Healthcare. HPLC sample preparation a study using Whatman brand filtration devices

Validation Guide. GBPES-series 0.2, 0.45, & 0.65 Micron Membrane Elements F517A_160901

Liquid Filters. Filter Cartridge and Housing Selection. How To Select The Filter Cartridge. How To Select The Filter Housing

1. Low profile units 2 Normal profile sterilisation filter units 3. Each pack includes 12 glass-fibre prefilters

Balston Liquid Filters

Properties of standard Bal Spring canted coil spring materials

CHM MRC Regenerated Cellulose Membrane Chemical Resistance. CHM MCA Cellulose Acetate Membrane Low adsorption. microfiltration.

Spectra/Por Biotech Dialysis Membranes Cellulose Ester (CE) Regenerated Cellulose (RC)

Sartobind IEX nano 3 ml

Milligard Filters. Superior filters for critical prefiltration applications. Benefits. Data Sheet. Data Sheet

Polysep II Filters. Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications

Filtration Products. Bubble Point rating(bar) ml /<25 μl ml

Chemical Resistance and Material Selection Guide for Drum Pumps

Chemical Resistance and Material Selection Guide for FTI Drum Pumps

Filtration Products. Best Value Guaranteed Product Quality Innovation to Benefit Customers

Amicon Ultra-4 Centrifugal Filter Devices

Sartobind IEX MA A Separation Technology Based on Macroporous Membranes

Sartobind TM Membrane Adsorbers Discs and Cassettes

Preferred. Steel, Epoxy Powder Coated. Satisfactory. Limited

Lifegard. Filters. Lenntech Tel Fax

GE Healthcare Life Sciences. Synchronized solutions for (U)HPLC sample preparation


DuPont Delrin 500P BK602

technical information

mdi Filters for Sample Preparation

3M Purification Inc. 3M High Flow Series Filter Systems

DuPont Delrin 500AL NC010

DuPont Minlon IG38C1 BK434

Bio-Scale Mini Affi-Prep Protein A Cartridges, 1 and 5 ml. Instruction Manual. Catalog # ,

DuPont Delrin 150 NC010

Minisart Syringe Filters. turning science into solutions

Minisart Syringe Filters. turning science into solutions

Minisart Syringe Filters. turning science into solutions

ProteoEnrich CAT-X SEC Kit Merck: Lichrospher Composition. Silica Particle size. 25 µm particles with 6 nm pore size Ligand SO 3

Profile A/S Series Filter Elements

DuPont Zytel 73G30HSL BK261

DuPont Delrin 100AL NC010

Illicit Discharge Compliance Statement

DuPont Zytel 73G45 BK263

DuPont Delrin 500CL NC010

Sterilizing Grade Filters USD 2461

Pall Supor EKV Sterilizing Grade Filters. USD 2461b

4 SPRINGS 6 SPRINGS 8 SPRINGS 10 SPRINGS 12 SPRINGS 14 SPRINGS

RYTON (PPS) Chemical Compatibility & Chemical Resistance Chart

DuPont Zytel 408 NC010A

DuPont Hytrel 4068FG (Preliminary Data)

ChromPure TM Syringe Filter

DuPont Delrin 100 BK602

BD PhaSeal System. Product Catalog

SOLVENT PROPERTIES Typical Physical Properties of More than 120 Commonly Used Organic Solvents

DuPont Delrin 100P NC010

DuPont Minlon 10B40 NC010

3M Plastic Bonding Adhesive 2665B, Black

Applications / Compatibility Guide

Balston OEM Disposable Filter Solutions

DuPont Zytel 8018HS NC010

Nominal Value Unit Test Method. Typical Value Unit Test Method 20 UTM nd

CATALOGUE FILTRATION & SEPARATION. Microfiltration

Balston OEM Disposable Filter Solutions

Series FBE-4 Type Phenolic Epoxy Powders Fusion Bonded Epoxy. General Description: Powder Feature: Particle Size Distribution (% undersize):

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

AcroPak TM. Product Family

DuPont Zytel 70G33HS1L BK031

Agilent Enhancer Cell

LABORATORY FILTER PAPER

Index Filters & Extraction

DuPont Zytel 73G30L NC010

Syringe Filters. Performance and Protection

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Polymer Block Cleaning Kit

compared to other tubing. It is 5 to 10 times more wear resistant and lighter in weight than any rubber hose. ATP Surethane NSF 51

TEST SUMMARY Biological Testing...18 Bacterial Retention...18 Viral Removal Validation...18 Toxicity...19 Chemical Testing...18 Compatibility...

2014 Annual Public Report Under O. Reg. 455/09. Honda of Canada Manufacturing Alliston, Ontario May 29, 2015

KryoSure and KryoVue Cryopreservation Products

0.01 Micron Membrane Filters

mdi Filters for Pharmaceutical and Biological

DuPont Zytel 70G30L NC010

Atlas Minerals & Chemicals, Inc. FURATHANE MORTAR. 5-33PI ( ) Supersedes 5-33PI (7-02) PHYSICAL PROPERTIES

PRODUCT DATA SHEET (rev. 2.12/2017)

DuPont Zytel 73G15HSL BK363

DuPont Zytel 70G33L NC010

DNA Synthesis With IRDye 700 Phosphoramidite. Part #

Streamlined Blow-Fill-Seal Insertion Technology Increases Flexibility and Safety in Aseptic Packaging of Pharmaceutical Liquids

Why filter your samples before analysis? Benefits of Using Chromfilter Syringe Filters Daily: Designed for your application:

168 West Main Street, #922, New Market, Md Revision 5.2 6/6/2017

DuPont Minlon 73M40 NC010

Revision 5.1 4/17/17

Separation and Purification Sciences Division Micro-Klean TM RT Series All-Polypropylene Rigid Thermal Bonded Filters

BRADY B-422 THERMAL TRANSFER PRINTABLE GLOSSY WHITE POLYESTER LABEL STOCK

Millipore Express. SHF Hydrophilic Filters. Sterilizing-Grade PES membrane for fast, efficient, economical buffer filtration

Industry Standards & Definitions

LifeASSURE 045SP Series

Temperature Sensing Standard Thermowells for Industrial Applications. Velocity Ratings of Wells. View Product

REFERENCE CAPACITY TIP SCALE BOX (UNITS) CASE (UNITS)

Balston Disposable Filter Units Ideal for the following gas filtration applications: Final filter for air logic devices Protection of pneumatic compon

mott corporation High Purity Products IGS Porous Metal Filters and Flow Restrictors.

LIGHTBLOCKS BOARD. stress cracking. chemical

ADVANTAGES OF POLYETHYLENE PIPES COMPARED TO PVC PIPES

Transcription:

User Guide Millex -GV Sterilizing Filter Unit (For Low-Binding Sterilization) Single use only Sterile Non-pyrogenic Do not use this product as an in-line filter for intravenous administration HCM0 518 01 (1000/box)

Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation. Millipore Corporation assumes no responsibility for any errors that may appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual. Copyright 2005. Millipore Corporation. Printed in Ireland. All rights reserved. Millipore, Durapore and Millex are registered trademarks of Millipore Corporation. Luer Lok is a trademark of Becton-Dickinson and Company. Freon is a trademark of E.I. du Pont de Nemours & Co., Inc. P36381, Rev. A, 10/05 0459 This product is manufactured by: Millipore Ireland BV Carrigtwohill Co. Cork

Introduction This document provides compatibility information, operating steps, and specifications for the Millex-GV sterilizing filter. This bi-directionally supported, low-binding sterilizing unit is designed to filter aqueous, proteinaceous substances where minimal sample loss is desired. It removes microorganisms, particles, precipitates, and undissolved powders larger than 0.22 micron (µm). This single-use product consists of a 0.22 µm Durapore membrane filter sealed in a PVC housing. It is sterile, non-pyrogenic, and non-toxic. Typical applications include the sterile filtration of tissue culture media, media additives, protein solutions,virus suspensions, monoclonal antibodies, DNA solutions, antibiotics, and lymphokines.

2 www.millipore.com/millex Chemical Compatibility The Millex-GV filter is compatible with most aqueous solutions. You may use it to filter the agents listed in the following chart. This information was developed from technical publications, materials suppliers, laboratory tests, and field evaluations, etc., and is believed to be reliable. However, because of variability in temperature, concentrations, duration of exposure, and other factors outside of our control that may affect the use of the unit, Millipore does not provide or imply a warranty with respect to such information. You should test the agents that are not listed with the Millex-GV filter prior to use. Chemical Acetic acid (glacial) Acetic acid (5%) Aliphatic ethers Ammonium hydroxide (6N) Amyl acetate Amyl alcohol Benzyl alcohol (1%) Boric acid Brine (sea water) Butyl alcohol Carbon tetrachloride Ethyl alcohol Ethylene glycol Formaldehyde Freon solvent, TF or PCA Glycerine (glycerol) Helium Hexane Hydroflouric acid Hydrogen (gas) Hydrogen peroxide (3%) Hypo (photo) Isobutyl alcohol Isopropyl acetate Methyl alcohol Mineral spirits Nitrogen Paraldehyde Pentane Pet base oils Petroleum ether Phenol (0.5%) Pyridine

Millex-GV Sterilizing Filter 3 How to Use the Millex-GV Filter Unit This section lists warnings and cautions and provides steps to use the Millex-GV filter unit. WARNINGS: To ensure sterility, do not use this product if the package is damaged. Do not use this product as an in-line filter for intravenous administration; it was not designed for that purpose. Do not use with syringes smaller than 10 cc because pressures in excess of the maximum pressure rating may be reached, potentially causing damage to the filter unit and/or personal injury. CAUTIONS: Do not resterilize or reuse the Millex-GV filter unit. Do not use the Millex-GV unit at temperatures above 45 C (113 F). Do not use the same Millex-GV unit to filter solutions in both directions. Do not use the Millex-GV unit to filter emulsions or suspensions. Do not use the Millex-GV unit to filter 5 milligrams (mg) or less of active drug materials unless you have performed binding studies.

4 www.millipore.com/millex Directions for the Millex-GV Sterilizing Filter Unit 1 2 3 Fill the syringe with the solution you want to filter. 4 Aseptically remove the cover from the package that contains the Millex-GV filter. 5 Attach the syringe to the Millex-GV filter and remove the assembly from the package. (Attach needle to Luer Slip outlet if necessary.) Hold the syringe with the filter (and needle if attached) pointing up and top it off by pushing a few drops through it. (Make sure you do not contaminate the underside of the Millex-GV filter with your fingers.) Insert the needle (if attached) and push the plunger to deliver the filtered solution.

Millex-GV Sterilizing Filter 5 Specifications Materials Dimensions Temperature limit Pressure limit at 25 C Filtration volume Hold-up volume Connections Sterilization method Flow rate at 25 C Hydrophilic Durapore (PVDF) membrane, type GV; Polyvinyl Chloride (PVC) housing inlet to outlet 25 millimeters (mm) (1.0 in.) diameter 29 mm (1.13 in.) filtration area 4 centimeters 2 (cm 2 ) (0.62 in 2 ) pore size 0.22 µm 45 C (113 F) maximum 75 psig (5 bar) inlet and differential maximum 1.0 milliliter (ml) to 100 ml 0.1 ml after air purge Female, Luer Lok inlet; male, Luer slip outlet Ethylene Oxide Gas Typical initial average flow rate for water at 30 psig: 40 ml/min

Technical Assistance For more information, contact the Millipore office nearest you. In the U.S., call 1-800- MILLIPORE (1-800-645-5476). Outside the U.S., see your Millipore catalogue for the phone number of the office nearest you or go to our web site at www.millipore.com/ offices for up-to-date worldwide contact information. You can also visit the tech service page on our web site at www.millipore.com/techservice. Warranty This product is covered by Millipore s standard limited warranty, as set forth in Millipore s Bioscience Catalogue.